N671UA
Service difficulty reports · 383
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N671UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N671UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2010090303247Light · looseEMERGENCY PATH LIGHTS NEAR 4H HAVE COME LOOSE. SECURED LIGHT. OPS NORMAL.SDR UALA2010081602969Light · missingSEAT 4AB 1EA EMERGENCY LIGHT PATH MISSING. FWD MISSING, AFT TEST NORMAL, NO TIME TO FIX. INSTALLED MISSING EMERGENCY LIGHT STRIP. CHECKS OKAY.SDR UALA2010080902880Hydraulic Line · leakingHYDRAULIC LEAK AT LT MAIN LANDING GEAR AREA. MAINT TEXT: AT LEFT MAIN GEAR OUTBOARD OF UPPER TRUNNION, FOUND FLEX LINE LEAKING. REPLACED FLEX LINE, PINED GEARS AND CYCLED GEAR UP AND DOWN 6 TIMES, NO LEAKS NOTED, SERVICED HYD LEVELS AND REPLACED UNDERWING SDR UALA2010072802731Filter · failedAPU INOP. AUTO SHUTSDOWN 10 SECONDS AFTER REACHING 95 PERCENT RPM. APU FAULT LIGHT ON. REFER TO MM-49-61-00, CODE C6. BITE APU BOX FOUND GEN FILTER MESSAGE. REPLACED GEN SCAVENGE FILTER IAW AMM. SERVICED OIL TO FULL. OPS CHECKED NORMAL.SDR UALA2010072602686Actuator · malfunctionedLEFT ENG NO START WITH LT ENG FUEL VALVE EICAS AND LT ENG SPAR VALVE. ALSO FOUND LT SPAR CIRCUIT BREAKER OUT. REPLACED LT ENGINE SPAR VALVE ACTUATOR ASSEMBLY (V25). OPS CHECKED GOOD.SDR UALA2010072602675Light · inoperativeEXIT PATH FLOOR LIGHTING BY 35H INOPERATIVE. LIGHTS ON EITHER SIDE, OPS NORMAL. REPLACED EMERGENCY LIGHT STRIP, TEST OK.SDR UALA2010071202476Indicator · leakingHYD QTY ZERO. EICAS MSG DISPLAYED (L & R) HYD QTY SYSTEM PRESS LIGHT NOT ILLUM, POS 1 (01=L,02=R). CREW COMMENTS: HYD QTY NOT ZERO, DECREASING SLOWLY FROM .37. FOUND DIFFERENTIAL PRESSURE INDICATOR FOR THE PRESSURE FILTER, IN NR 1 ENGINE PYLON, DRIPPING STSDR UALA2010061702146Actuator · leakingWITH MLG IN THE UP POS FOUND LT MLG RETRACT ACTUATOR LEAKING AT THE 12 O'CLOCK POSITION. HOUSING APPEARS TO HAVE A CRACK CAUSING LEAK. LT LANDING GEAR JUST OUTBOARD OF GEAR HAS HYD FLUID ON LOWER SURFACE. OPERATED ALL HYD SYSTEMS. OPERATED FLIGHT CONTROLS ANSDR UALA2010060101886Battery · faultyMAIN BAT CHARGER STATUS MSG WOULD NOT ERASE. REPLACED MAIN BATTERY & CHARGER, OPS CKD OK, MSG CLEARED.SDR UALA2010052101712Case · crackedAPU OIL QTY STATUS MSG. REPLACED APU GENERATOR, DUE TO CRACK IN UPPER CASE AREA LEAKING OIL. RAN APU, OPS CHECK GOOD. NO LEAKS NOTED.SDR UALA2010051001567Motor · faultyCIRCUIT BREAKER H24 POPPED ON OVERHEAD PANEL. FTL CREW REPORTS H24 CB POPPED DURING CRUISE PHASE OF FLIGHT. REPLACED SLAT DRIVE OTBD ALTERNATE MOTOR. ACP TEST FOR BYPASS VALVE ROTARY ACTUATOR AND CHECKED FSEU BITE BOX WITH NO FAULT LIGHTS ON. C.B H24 STAYED CSDR UALA2010051001593Lamp · missingEMERGENCY ESCAPE PATH LIGHT MISSING AT SEAT 1H. REPLACED LAMP ASSY.SDR UALA2010033101078Pump · inoperativeADP INOP, REMOVE AND REPLACE ADP AND ASSOCIATED AIR MODULATING VALVE.SDR UALA2010033101079Warning System · activatedON GEAR RETRACTION C HYD DEM PUMP EICAS AND ASSOC OVERHEAD PSI LIGHT ILLUM, RAN FLT MAN SOP NO HELP.SDR UALA2010033001069Modulating Valve · faultyADP FAILURE, RTFL. ON GEAR RETRACTION C HYD DEM PUMP EICAS AND ASSOC OVHD PSI LIGHT ILLUM. RAN FLT MAN SOP, NO HELP. REMOVED AND REPLACED ADP AND ASSOCIATED AIR MODULATING VALVE.SDR UALA2010032901032Relay · inoperativeC ADP LOW PRESS LIGHT ILLUMINATED IN AUTO. EICAS MSG DISPLAYED C HYD DEM PUMP. ADP PRESS IS NORMAL. COMMENTS: C HYD DEM PUMP. FOUND ADP INOP IN AUTO AND ON MODE. TROUBLESHOT AND REPLACED K443 RELAY. OPS CHK OKAY.SDR UALA2010032200936Light · brokenEEL LIGHTS FLASHING ON AND OFF IN FIRST CLASS. FOUND 1 SEAT MOUNTED LIGHT STRIP AT SEAT 1H HAS HALF OF STRIP BROKEN OFF. REMAINING PORTION OF STRIP OPERATES AND ALL OTHER LIGHTS OPERATE NORMALLY. REPLACED SEAT 1H FWD EMERGENCY PATH LIGHT ASSY, OPS NORMAL. SDR UALA2010030800778Light · brokenF-C PAX SEAT 2B FWD EMERGENCY LIGHT ASSY BROKEN. REPLACED PAX SEAT EMERGENCY LIGHT ASSY AND OPS CK'D GOOD.SDR UALA2010030800785Valve · malfunctionedRT DUCT FLUCTUATES + OR - 20 PSI. ACCOMPLISHED HPSOV HEALTH CHECK, REPLACED PRV PER AMM AND HPC PER AMM AGAIN, NO HELP. RT PNEUMATIC PRESSURE STILL FLUCTUATES 40-20, N2 77-80%, BLEED OFF LIGHT ILLUMINATED, ONLY HAPPENS ON DECELERATION. LOCKED OUT HPSOV PER SDR UALA2010030500763Shutoff Valve · malfunctionedRT DUCT FLUCTUATES +/- 20 PSI DURING DESCENT. LOCKED OUT HIGH STAGE VALVE CLOSED PER MEL. ACCOMPLISHED HPSOV HEALTH CHECK, REPLACED PRIORITY VAVLE PER AMM36-11-18, HPC PER AMM AGAIN, NO HELP. RT PNEUMATIC PRESS STILL FLUCTUATES 40-20, N2 77-80%, BLEED OFF LIGSDR UALA2010030100739Bleed Valve · fluctuatesRIGHT PNEUMATIC PRESS FLUCTUATES FROM 10 TO 30 PSI WHEN POWER REDUCED FOR DESCENT. REPLACED FAULTY NR 2 ENG FAN AIR MODULATING VALVE. OP CHECK AND LEAK CHECK GOOD. BITE CHECK OF AIR SUPPLY MODULE CHECK GOOD.SDR UALA2010030100736Light · brokenSEAT 27AB EMERGENCY EMERGENCY LIGHT ASSY IS BROKEN. REPLACED EMERGENCY LT ASSY. OPS CHKD, OK.SDR UALA2010022600711Wire · shortedTAKEOFF CONFIGURATION WARNING. ACP PROX SENSOR WIRING RESISTANCE CHECK FOR S266,S267,S268. FOUND S267 R & B WIRES SHORTED TO GROUND WITH 27MEG OHM. ALL OTHER PROX SWITCHES TEST OK. REPLACED S267, STILL NEEDS CHK GAPS WITH TRUCK TILTED. MEASURED GAPS USINGSDR UALA2010022300668Pump · leakingADP HAS A 24 DROPS PER MINUTE HYD LEAK WITH THE PUMP NOT OPERATING OUT OF THE WEEP HOLE PLUG ON THE INBOARD SIDE OF THE GEARBOX. REPLACED ADP. OPS NORMAL.SDR UALA2010022300667Fairing · puncturedLT WING INBD FLAP TRACK WING TO BODY FAIRING PUNCTURED. APPROX ONE HALF INCH SQUARE. SUPPLEMENTAL DATA UPDATE HOLE WITHIN LIMITS REF SRM. 2 SHIFT SLOT REQUESTED. REQUIRED FOR ACCESS. REPAIRED HOLE REF MM.SDR UALA2010021900632Computer · defectiveSPOILER AND FLAP EICAS WARNING ON LANDING ROLLOUT WITH SPEED BRAKES AND REVERSERS DEPLOYED. REPLACED EICAS COMP, NO HELP, MSG CLRD, SOFTWARE WOULD NOT INPUT, INOPERATIVE PER MEL. REMOVED AND REPLACED LT EICAS COMPUTER AND LOADED SOFTWARE IAW MM. NO DEFECTS SDR UALA2010021500574Isolation Valve · faultyCLIMB & DESCENT N2 ABV 70P PERCENT LT DUCT PRESSURE VASCILATING FROM 30 TO 38 PSI. BOTH SYS OP CK OK ON ENGINE RUN THROUGH BLEED SHIFTS. LT ISOLATION CHECK VALVE WAS CHANGED. SYS OP CHECK OK.SDR UALA2010021100519Lamp · inoperativeEXTERIOR EMERGENCY LIGHT INOP AT DOOR 1 RT. CONFIRMED DOOR 1 EXTERIOR EMERGENCY LIGHT INOP. RELAMPED EXTERIOR LIGHT. LIGHT TEST NORMALSDR UALA2010020100383Circuit Card · malfunctionedIDLE DISAGREE EICAS LTN1 30 PERCENT RT 38 PERCENT N1 EQUAL W/ENG AI ON. INTEGRATED BOTH LT-RT PIMUS, IDENTIFIED LEFT ENGINE NUMEROUS FAULTS. REPLACED LT ENGINE SPEED CARD IAW MM. GRD TEST CARD OK.SDR UALA2010012500307Battery · faultyAPU WILL NOT START. HANGS AT 40 PERCENT THEN SHUTS DOWN WITH FAULT LT 777 EGT. REPLACED APU BATTERY AND APU DOOR ACTUATOR IAW MM, OPS CHECKED GOOD.SDR UALA2010012000244Shutoff Valve · malfunctionedRT ENG BLEED OFF EICAS AFTER ENG START. VALVE FOUND INADEQUATE. REPLACED PRSOV AND RAN ENG, OPS CHECKED NORMAL.SDR UALA2010010400032Warning Light · illuminatedNR 2 ENG OIL FILTER MSG DISPLAYED. MESSAGE REMAINED WHEN THRUST REDUCED. ENG NOT SHUTDOWN. RT OIL FILTER EICAS INTERMITTENT. HAS COME ON ABOUT 4 TIMES FOR ABOUT 5 SECONDS. RT PRESS=212. CHECKED MAIN GEARBOX AND ANGLE GEARBOX CHIP DET OK. REPLACED DPI SWISDR UALA2010010400050Light · brokenEMERGENCY LIGHTS IN FIRST CLASS ILLUMINATING INTERMITTENTLY (COCKPIT SWITCH IN ARMED) FOUND SEAT 1H AFT EMERGENCY LIGHT BROKEN. SECURED WIRE. CYCLED EMERGENCY LIGHT SWITCH ALL EMERGENCY LIGHTS CHECK EXCEPT SEAT 1H AFT.SDR UALA2010010400014Light · brokenEMERGENCY LIGHTS IN FIRST CLASS ILLUMINATING INTERMITTENTLY (COCKPIT SWITCH ARMED) FOUND SEAT 1H AFT EMERGENCY LIGHT BROKEN. SECURED WIRE. NO PARTS PCN 566-1373. CYCLED EMERGENCY LIGHT SWITCH ALL EMERGENCY LIGHTS CHECK EXCEPT SEAT 1H AFT. LIGHT ASSY ON ORSDR UALA2009123004060Skin · damagedLIGHTNING STRIKES FOUND FROM STA 212 TO STA 434 FROM WATERLINE AND BELOW. ALSO LIGHTNING STRIKES FOUND ON LT SIDE OF ACFT FROM STA 132 TO 172. (FROM RADOME BACK TO RVSM AREA.) REPAIRED LIGHTING STRIKE DAMAGE FROM RADOME TO DOOR 1L & FROM STA 212 TO STA 434 FRSDR UALA2009122403992Line · rupturedLEFT MLG NO RETRACT, RTFL. FOUND RUPTURED HYD LINE ON LT GEAR. REMOVED DAMAGED LINE AND CAPPED LINES. REPLACED HYD LINE NR 80. GEAR NEEDS TO BE RETRACTED FOR HYD LINE LEAK CHECK. JACKED AND PERFORMED GEAR RETRACTION. ACFT OK FOR SVC.SDR UALA2009121403847Lamp · out of positionUNIDENTIFIED LIGHT PLATE FOUND ON FLOOR NEAR DOOR 1L. APPROX 4" LONG BY 1" WIDE. THIS IS 1 OF THE 2 SEAT MOUNTED EMERGENCY LIGHTS FOR SEAT 1H. WILL NEED NEW LT STRIP. REPLACED EMERGENCY LIGHT LAMP. OPS CKS OK.SDR UALA2009120103712Panel · damagedSEVERE TURBULENCE ENCOUNTERED. LT WING T/E FIXED PNL 2 FT SEC LOOSE AT FWD END. WORKING WITH EG FOR EVA TO INTERIM REPAIR. FOUND ADDITIONAL DAMAGE TO SPOILER FIT BEYOND LIMIT. WILL REQ REPLACEMENT. HAVE LT WING TE FIXED PNL 2 FT SEC LOOSE AT FWD END. WORSDR UALA2009101603243Battery · faultyEICAS MSG MAIN BATTERY CHARGER. REPLACED MAIN SHIP BATTERY AND CHARGER. CHECKS OKAY.SDR UALA2009100603141Control Panel · frozenMCP IS FROZEN. REPLACED MCP. MCP FOUND FAULTY. REPLACED AUTOPILOT MODE CONTROL PANEL. OP CKS GOOD.SDR UALA2009092303016Pump · malfunctionedTHE C-HYD PRIM 1 EICAS AND C OVERHEAT 1 ILLUMINATED. THE C-HYD 1 PUMP TURNED OFF PER FLT MANUAL. REPLACED C1 HYD PUMP. OPS AND LEAK CHECK NORMAL.SDR UALA2009082402594Unknown · odorSTRONG ACRID BURNING SMELL IN COCKPIT FROM TOP OF DESCENT THROUGH LANDING. OVENS OFF DURING ENTIRE EVENT. NO SMELL IN GALLEY OPENED MAIN ELECTRICAL PANELS, CARD FILES AND CHECKS FOR WIRING FAULTS IN E&E COMPARTMENT. ALSO CHECKED NOSE TUNNEL AND OPENED ALL CSDR UALA2009081702515Lamp · out of positionFIRST CLASS LEFT EMERGENCY PATH LIGHT FLICKERED ON CLIMB, STABLE NOW. SEATS ROW 2+3 EMERGENCY LIGHT FOUND FWD LAMPS ON SEATS 2B AND 3B PULLED OUT. REINSTALLED AND SECURED. OPERATION CHECK LIGHTS OK.SDR UALA2009080702403Light · unsecureEMERGENCY LIGHT AT SEAT 24H UNSECURED. SECURED EMERGENCY LIGHT AT SEAT 24H. OPS CHECKED LIGHT OK AT SEAT 24H.SDR UALA2009080602384Light · brokenSEAT 23 RT SIDE EMERGENCY LIGHT BROKEN. REPLACED LIGHT ASSY. FUNCTION CHECKS GOOD.SDR UALA2009072702233Gcu · faultyRIGHT ENGINE GENERATOR FIELD LIGHT ON IN COCKPIT. REPLACED RIGHT GENERATOR CONTROL UNIT. FIELD OFF LIGHT IS OUT NORMAL.SDR UALA2009070701956Oxygen Mask · inoperativeCAPTS O2 MASK MICROPHONE INOP. REPLACED CAPTS MASK, NO HELP. CHANGED 1ST OBS O2 MASK (BOX), OPS OKAY.SDR UALA2009062501799Aspirator · leakingASPIRATOR LEAKS FROM BARREL. THERE IS NO PHYSICAL OR EXTERNAL DAMAGE TO THE ASPIRATOR. THE ASPIRATOR IS LEAKING FROM INTERNAL COMPONENTS, THEREFORE THE CAUSE CANNOT BE DETERMINED. REPLACED ASPIRATOR.SDR UALA2009062401793Connector · unsecureEMERGENCY LIGHTS FROM ROW 10-17AB INOP. SECURED CONNECTOR.SDR UALA2009062401792Connector · unsecureEMERGENCY LIGHT AT LT MID LAV INOP. SECURED CONNECTORS.