Service difficulty report · Valve · Boeing 767322

Difficulty date
March 2, 2010
Submitted
March 8, 2010
Operation
Air carrier
Aircraft
N671UA
Make and model
Boeing 767322
Aircraft serial
30026
Aircraft time
38,165 hours, 10,092 cycles
Engine
Pwa PW4056
Part
Valve
Part number
7732887810
Part serial
83
Condition
Malfunctioned
Location
Bleed Sys
Stage of operation
DE
How discovered
O
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

RT DUCT FLUCTUATES + OR - 20 PSI. ACCOMPLISHED HPSOV HEALTH CHECK, REPLACED PRV PER AMM AND HPC PER AMM AGAIN, NO HELP. RT PNEUMATIC PRESSURE STILL FLUCTUATES 40-20, N2 77-80%, BLEED OFF LIGHT ILLUMINATED, ONLY HAPPENS ON DECELERATION. LOCKED OUT HPSOV PER MEL. SUSPECT M860 BLEED CONTROL CARD. PER CREW, IN CRUISE WITH HPSOV LOCKED CLOSED, DUCT PRESSURE IS STABLE AT 24PSI EACH SIDE. VERIFIED HIGH STAGE SYS REACTIVATED. PERFORMED BLEED SYS TEST WITH AIR LEED MON TEST & LAPTOP HOOKUP, AFTER PRSOV REPLACED BLEED PARAMETERS ALL CHECKED GOOD, NO VASCILLATIONS PRESENT.