Service difficulty reports · 383
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N671UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N671UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 2008UALA00366Stiffener · crackedCRACKED VERTICAL STIFFENER ANGLE ON FLOORBEAM AT STA 246 LBL 26. REMOVED AND REPLACED STIFFENER. ACFT OK FOR SERVICE.SDR 2008UALA00128Transducer · faultyRUDDER RATIO LIGHT ILLUM IN FLIGHT. EICAS MSG RUDDER RATIO DISPLAYED. REPLACED LEFT ELEC HYD PUMP CONTROL PRESS SWITCH AND INSPECTED CONNECTOR, NO DEFECTS FOUND. REPLACED RUDDER RATIO LVDT. OP CHECK NORMAL, OSCILATION CHECK NORMAL.SDR 2007UALA05113Pump · leakingRT HYD PUMP LEAKING.SDR 2007UALA05078Warning Light · illuminatedRTFL DUE TO EICAS "R GEN OFF" DISPLAYED AT LIFT - OFF, WILL NOT RESET.
SDR 2007UALA04993Warning Message · illuminatedNR 2 ENG OIL FLTR EICAS MSG AFT ENG START. TEMP UP TO 74C AND MSG STILL WOULD NOT ERASE.SDR 2007UALA03763Light · inoperativeSEAT 5J AND 24J EEL LIGHT INOPERATIVE. 10-19-07 REPLACED EEL LIGHTS . OP CHECKED OK.SDR 2007UALA03145Cover · missingTHE 1HJ EMERGENCY EXIT LIGHTING PLASTIC COVER MISSING. REPLACED LIGHT. TESTS OK.SDR 2007UALA03025Light · unsecureSEAT 4HJ EMERGENCY LIGHT STRIP ON SIDE OF SEAT FALLS OFF. 08-31-07 REPLACED EEL STRIP AT 4HJ. OP CHECKD EEL SYSTEM. OK FOR SERVICE.SDR 2007UALA02523Pump · inoperativeLOST LEFT ENGINE DRIVEN HYD PUMP. [08-08-07] REPLACED LEFT HYD ENG PUMP PER MM 29-11-05. OPS CKS OK. NO LEAKS AFTER SHUTDOWN. AFTER LT HYDRAULIC EDP CHANGE FOUND PUMP LOW PRESSURE LIGHT AND EICAS MSG REPLACED EDP PRESSURE SWITCH. ALSO, REPLACED CONNESDR 2007UALA02400Connector · unsecureEEL LIGHTING INOP SEATS 26HJ THROUGH 36HJ. [07-27-07] SECURED EEL CABLE'S CONNECTOR AT 35H, OP CK GOOD.SDR 2007UALA02399Light · inoperativeEEL LIGHT AT SEAT 30AB IS INOPERATIVE. RELAMPED EMERGENCY LIGHT CHECKS GOOD.SDR 2007UALA02310Warning System · activatedON DESCENT RECEIVED, LT ENG HPSOV EICAS MESSAGE. [07-24-07] AFTER TROUBLESHOOTING WITH INCONCLUSIVE RESULTS, CONDUCTED BORESCOPE ON NR 2 ENG SN 724700. ENGINE FAILED BORESCOPE INSPECTION ON EC6271 DUE TO COMBUSTION CHAMBER CONTINOUS AXIAL CRACKS THRU MORE SDR 2007UALA01800Door · damagedLARGE STRUT DOOR AT RIGHT MAIN GEAR FOUND DAMAGED DURING WALKAROUND. [07-31-07] REPLACED RT MAIN GEAR STRUT DOOR PER MM 32-12-01. ACCOMPLISHED RII INSPECTION OF RH STRUT DOOR INSTALLATION, RIGGING, GEAR SWING AND ALTERNATE EXTENSION PER MM 32-12-01. AIRCRSDR 2007UALA01718Skin · scratchedRIGHT LOWER FUSELAGE SKIN BETWEEN STA 1480 & 1510 HAS SCRATCH, 1 AREA AT STA 1480 IS APPROX 6 INCHES LONG AND DENTED ALONG THE LAP SEAM. [07-10-07] SKIN WAS REPAIRED PER SRM-53-00-01, REPAIR NR 12. HFEC WAS DONE WITH GOOD RESULTS. A/C OK FOR SERVICE.SDR 2007UALA01295Light · missingSEAT MOUNTED EMERGENCY LIGHT MISSING AT SEAT 41AB. REPLACED MISSING LIGHT.SDR 2007UALA01251Cover · looseDOOR 1R SLIDE PACK COVER APPEARS LOOSE. [SUP 05-18-07] SLIDE REMOVED FROM ACFT. REINSTALLED REPLACEMENT SLIDE. SLIDE BUSTLE REINSTALLED. A/C RETURNED TO SERVICE. SLIDE PROBLEM ROOT CAUSE: SUSPECT IMPACT BY CLEANING & FOOD SERVICE EQUIPMENT LOOSENED PACK COSDR 2007UALA01050Battery · faultyMAIN BATTERY CHG STATUS MSG. [SUP 5-1-07] REPLACED BATTERY CHARGER. CHECKS OK FOR SERVICE. SUSPECT CHARGER SHORTED OUT.SDR 2006UALA01657Button · out of positionFOUND DOOR 1R GREEN DISARM BUTTON WILL NOT POP OUT WITH DOOR IN DISARM. TRIMED FORWARD SHROUD SO GREEN DISARM BUTTON ON 1R CAN OPERATE NORMALLY. CHECKS OK FOR SERVICE.SDR 2006UALA01611Lamp · burned outAFT RIGHT ENTRY DOOR EXIT LIGHT HAS 3 EACH BURNT LAMPS. RELAMPED LIGHT ASSEMBLIES IAW B767 MM 33-51-01. OK CHECKS OK.SDR 2006UALA01600Floorbeam · crackedE+E BAY, STA 246 FLOORBEAM, LBL 6, FWD SIDE, VERTICAL STIFFENER CRACKED.SDR 2006UALA01591Attach Angle · crackedE/E BAY, STA 246 FLOORBEAM, LBL 2, FWD SIDE, VERTICAL ATTACH ANGLE (STIFFENER) CRACKED. MAJOR REPAIR: REMOVED DAMAGE. FABRICATED AND INSTALLED NEW ANGLE PER BAC DWG 255T1245 AND SRM 51-40-2.SDR 2006UALA00913Wire · damagedRETURNED TO HNL DUE TO NR 2 ENGINE PNEUMATIC BLEED PROBLEM. THE PRV (MR36213 - 483) & PRV CONTROLLER (MR36140 - 111) WERE REMOVED 1ST. HOWEVER, THERE WAS STILL NO PRESSURE IN THE SYSTEM AFTER REPLACING THE PRV AND CONTROLLER. NEXT, THE RH PRSOV (MR36159 - 23)SDR 2006UALA01158Latch · failedLT O/W LATCH SYS INTEGRATOR FAILS TORQUE CHECK. REPLACED LATCHES (LT) IAW 767 MM25-65-98.SDR 2006UALA00321Warning Horn · activatedFLIGHT DIVERTED DUE TO CONTINUOUS TAKEOFF CONFIGURATION WARNING HORN. RESET CB'S AND WEU PSU'S. ACCOMPLISHED CHECKS PER MM 31-51-00 FIG 103: NO FAULTS NOTED. FOUND CAUSE TO BE FLAT NOSE GEAR STRUT CAUSING NOSE AIR GROUND SENSORS/SWITCHES S266 & S244 TO REMAISDR 2005UALA00716Piston Rod · crackedCRACKED PISTON IN NOSE LANDING GEAR RETRACT ACTUATOR. ON WALKAROUND FOUND NOSE LANDING GEAR ACTUATOR ROD NEAR ROD END CRACKED. CONFIRMED WITH EDDY CURRENT. REPLACED NOSE GEAR ACTUATOR PER MM 32-34-01. HYDRAULIC QUANTITY WAS OK.SDR 2004UALA00997Battery · dischargedRIGHT OVERWING SLIDE SQUIB DOES NOT TEST IN POSITION 1. DEFECT CAUSED BY LOW BATTERY. REPLACED RIGHT HAND BATTERY.SDR 2004UALA00983Compressor · stalledCOMPRESSOR STALL REPORTED ON NR 1 ENGINE, ON CLIMB, ENGINE SELF RECOVERED AND CONTINUED NORMAL OPERATION.SDR 2004UALA00845Battery Pack · failedNR 1 RT WING SLIDE SQUIB FAILS TO TEST. REPLACED BOTH LEFT AND RIGHT BATTERY PACKS AND RIGHT ESCAPE SYSTEM RELAY ASSY M1136. SYSTEM TEST 1 AND 2 CHECK NORMAL.SDR 2004UALA00741Light · inoperativeFORWARD GALLEY EEL LIGHT INOPERATIVE. REPLACED LIGHT ASSY.SDR 2004UALA00710Squib · will not testNO LIGHT TEST ONE OR TEST TWO RIGHT SQUIB. REPLACED RIGHT OVERWING SLIDE BATTERY AND POWER SUPPLY .SDR 2002UALA01406Adc · faultyFIRST OFFICERS AIR DATA COMPUTER FAILED. FIRST OFFICER AIR DATA INSTRUMENT FLUCTUATING, RUDDER RATIO AND AILERON LOCKOUT EICAS MESSAGE DISPLAYED. REPLACED THE FIRST OFFICER AIR DATA COMPUTER. CONFIRMED THE FAULT, UNIT SENT TO THE MANUFACTURER FOR EVALUATIONSDR 2001UALA00548Stop · damagedREAR CARGO CONTAINER DOOR STOP FITTING BROKEN LOOSE FROM DOOR FRAME STRUCTURE. MAJOR REPAIR ACCOMPLISHED. REMOVED AND REPLACED STOP FITTING 140T2112 WITH SERVICEABLE PART, RIGGED S160 PROX SWITCH PER MM52-35-43, CHECKED DOOR STOP RIG PER MM52-35-00. REPLACED SDR 2000UALA00032Access Panel · crackedFOUND ON WALKAROUND NR 1 AND NR 2 AFT STRUT MOUNT BOLT ACCESS PANELS INBOARD SIDE SEVERLY CRACKED WITH 2 PULLED SCREWS EACH PANEL. PANEL P/N 313T3200-351 AND 352- M615100 F. CRACKS ON NR 1: 3 IN AND 4 IN; NR 2 ONE CRACK 2 IN. SIMILAR CONDITION NOTED ON OTHE