What was found
E/E BAY, STA 246 FLOORBEAM, LBL 2, FWD SIDE, VERTICAL ATTACH ANGLE (STIFFENER) CRACKED. MAJOR REPAIR: REMOVED DAMAGE. FABRICATED AND INSTALLED NEW ANGLE PER BAC DWG 255T1245 AND SRM 51-40-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
E/E BAY, STA 246 FLOORBEAM, LBL 2, FWD SIDE, VERTICAL ATTACH ANGLE (STIFFENER) CRACKED. MAJOR REPAIR: REMOVED DAMAGE. FABRICATED AND INSTALLED NEW ANGLE PER BAC DWG 255T1245 AND SRM 51-40-2.