N673UA
Service difficulty reports · 346
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N673UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N673UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2021081601341Battery Pack · inoperativeB767-33-3-7000 CABIN R/H ROW NO.12-33 AISLE EMER LT FOUND INOP. AFTER EMERGENCY LIGHT BATTERY PACK REPLACED AND OPERATIONAL TEST OF EMERGENCY LIGHTS CARRIED OUT RESULT NORMAL AS PER AMM33-51-00 ADD EMP:V898561SDR CALA2021040500420Tat Probe · faultedTAT PROBE MESSAGE ON LIFTOFF FOUND CB P63 GRID L 18 "L TAT" PROBE HEAT OPEN. CLOSED CB AND PERFORMED OPS CK REF AMM 34-12-02-404-008. CB REMAINED CLOSED THROUGH OUT TEST. AS PRECAUTION REPLACED K411 LEFT TAT PROBE CURRENT SENSING RELAY IN P33 PANEL. ALSO PERFOSDR CALA2020032700731Check Valve · out of positionREF TASKCARD 63-4720-1-7800 FOUND EXISTING FUEL CROSS VENT CHECK VALVE P/N: 2020138-101 LOCATED AT LHW STRINGER U-9,O/B OF RIB 31 REFER TO AMM 47-21-03 FIG 401 SHEET 1 & SB767-47-0001, IT SHOULD BE LOCATED AT STRINGER U-13. NRC 9130578 ACCOMPLISHED EC/RA 4721-SDR CALA2020032100664Structure · crackedB767-06-3-7009 BULK CARGO DOOR LOWER EDGE FOUND CRACKED, REF NRC 9130403 BULK CARGO DOOR LOWER EDGE REPAIRED AS PER EC/RA 5236-01020 REV ORG ADD EMP:INSPECTED AND APPROVED.SDR CALA2019092701637Light · looseEXIT ROW FLOOR LIGHTING STRIPS AT SEATS 21 DEF IS LOOSE AND OUT OF TRACKS. REPLACED CROSS ISLE LIGHT STRIP AND OPS CHECKED OK REF AMM 33-51-501.. ALSO BATTERY PACK REPLACED..SDR CALA2019080501315Lavatory · inoperativeTWO FWD LAVS AND 1 ECONOMY LAV WILL NOT FLUSH/ LAV SYS 2 CB POPPED .SDR CALA2018070301557Stringer · corrodedAFT CARGO COMPT CORROSION AT STR 39L BETWEEN STA 1395 AND 1417. REPAIRED STRINGER 39L AT STA 1395 THROUGH STA 1417 WITH A PERMANENT STRINGER REPAIR AS PER SRM 53-00-03 FIG 201 DETAIL III REF.SDR CALA2018060531365Frame · crackedRIGHT FRAME BS 903.5, INNER STRUCTURE WAS CRACKED. REPAIRED IAW AD 2012-22-17.SDR CALA2018060531364Frame · crackedLEFT FRAME BS 903.5, INNER STRUCTURE WAS CRACKED. REPAIRED THE FRAMESDR CALA2018011900232Latch · failedLEFT OVERWING ESCAPE SLIDE DOOR LATCH AND DISCONNECT, TORQUE CHECK FAILED IAW EA2560-02662, OPS 1. ACCOMPLISHED TORQUE CHECK IAW EA 2560-02662-OPS1.SDR CALA2017111003983Altimeter · reads lowFL 380 ALTIMETER DISAGREE EICAS. CAPTAIN`S ALTIMETER 200 FEET LOW. CAPTAIN`S 37800 FT, STBY 38500 FT, FO 38000 FT. ACCOMPLISHED VISUAL CHECK OF PITOT STATIC DRAIN PORTS, LINES, AND CONNECTORS. NO OBVIOUS DAMAGE FOUND. LOW AND HIGH RANGE LEAK CHECKS PERFORMESDR CALA2017110303911Light · inoperativeCROSS-AISLE EMERGENCY LIGHT ELL STRIP INOP AT SEAT ROW 21DEF. REMOVED AND REPLACED CROSS AISLE EMERGENCY LIGHT STRIP. OPERATIONAL TEST IS GOOD REF AMM 33-51-00-715-019-001.SDR CALA2017092203258Warning Message · false activationLEADING EDGE FLAP ASYM ON APPROACH. EMERGENCY DECLARED. PERFORMED FSEU BITE, NO FAULTS NOTED. OPS CHECKED FLAPS AND SLATS IAW AMM 27-81-00. OPS CHECKED NORMAL, NO EICAS MESSAGES NOTED. OK TO CONTINUE.SDR CALA2017082502880Light · detachedFLOOR EMERGENCY LIGHT HAS COME OFF THE FLOOR AT ROW 21 DEF. SECURED EMERGENCY LIGHT. OK TO CONTINUE.SDR CALA2017073002448Light · looseEMERGENCY EXIT FLOOR LIGHT STRIP OVER CENTER LOOSE NEEDS SECURING FLOOR PROXIMITY LIGHT INSTALLED PER AMM 33-51-10, OK FOR SERVICE .SDR CALA2017060501698Latch · wornLT WING SLIDE EICAS ADVISORY DISPLAYED AND OVERHEAD EMERG DOORS LIGHT ILLUMINATED. WHILE T/S FOUND SLIDE COMPARTMENT LATCHES WITH EXCESSIVE PLAY. REPLACED LATCHES AND ATTACHING HARWARE PRECAUTIONARILY. AMM 25-65-09 & AMM 52-21-01. EICAS ADVISORY MESSAGE EXTINSDR CALA2014031990644Unknown · malfunctionedON LANDING LT THRUST REVERSER WOULD NOT DEPLOY, LEVER WOULD NOT GO INTO REVERSE. CYCLED SYS. REVERSER LEVER OPERATED NORMALLY. NO FAULTS OR MESSAGES FOUND, CHANGED MODULE PRECAUTIONARY.SDR CALA2014031090570Unknown · malfunctionedDIVERSION DUE TO PACK INOPERATIVE.SDR CALA2013112693270Trim Panel · looseDOOR 1R WILL NOT ARM. FOUND TRIM STRIP FOR THE GALLEY FLOOR LONCOIN AT THE R1 DOOR COMING LOOSE BLOCKING THE GIRT BAR FROM ARMING. REMOVED TRIM STRIP, R1 ARMS NORMALLY. PLACED TRIM STRIP ON CF IAW GMM 05-30-06, IAW IPC 25-27-51-83 ITEM 55, PART BAC1522-129-SDR CALA2013112593221Switch · not seatedLT AFT FUEL PUMP LOW PRESS SWITCH INOPERATIVE. FOUND LT AFT FUEL PUMP OVERHEAD PANEL BUTTON SWITCH NOT SEATED PROPERLY. RESEATED PUSH BUTTON SWITCH OPERATIONS CHECKED GOOD.SDR CALA2013112293196Transceiver · faultyWXR SYS STATUS MSG DISPLAYED. REPLACED RT IAW AMM, OPERATIONS CHECKED NORMAL.SDR CALA2013112193159Anti-Ice Valve · malfunctionedCREW REPORTS AFTER ENG START LT WING VLV LIGHT ILLUMINATED. IAW FIM 30-11-00 TROUBLE SHOT. REPLACED RELAY 414 & 520, NO HELP. REPLACED WING ANTI ICE VLV IAW AMM. TESTED LT WING ANTI ICE VLV IAW AMM, OPERATIONS CHECKED OKAY, OK FOR SERVICE.SDR CALA2013111993055Pressure Switch · inoperativeLEFT AFT FUEL PUMP PRESSURE LIGHT WON'T ILLUMINATE. FUEL PUMP INOPERATIVE. REPLACED PRESSURE SWITCH, OPS CHECKED GOOD.SDR CALA2013101592071Controller · faultyAUTO INOPERATIVE DISPLAYED ON OVERHEAD PANEL FOR CABIN ALTITUDE CONTROL IN AUTO 1 & AUTO 2. R & R NR 2 AUTO PRESSURE CONTROLLER IAW AMM 21-31-02. INSTALLATION TEST PASSED.SDR CALA2013100991882Oxygen System · low pressureCREW OXYGEN LOW INDICATING 980 PSI. SERVICED CREW O2 TO 1800 PSI IAW AMM 12-15-08 OK TO CONTINUE, NO LEAKS NOTED.SDR CALA2013100791812Indication Sys · malfunctionedRT CRT TANK FUEL BOOST PUMP WITH SWITCH IN OFF POSITION, NO LOW PRESS LIGHT & ADVISORY EICAS MESSAGE. CONFIRMED & VERIFIED RT CRT TANK FUEL BOOST PUMP INOPERATIVE & NOT RUNNING WITH PB SWITCH IN OFF POSITION. ITEM DEFERRED IAW MEL 2822H & PLACARD APPLIED. MESDR CALA2013100791798Shield · damagedDAMAGE TO LT MLG BOOGIE BEAM SHIELD. PERFORMED DETAIL INSPECTION NO FURTHER DEFECT FOUND. REMOVED BOOGIE BEAM SHIELD IAW CDL 32A. REPLACED SHIELD.SDR CALA2013100791773Display · dirtyUPPER EICAS DISPLAY ALL BLUE INSTEAD OF WHITE. SUSPECT DISPLAY FAILING. UPPER EICAS DU INLET SCREENS CLEANED. DU, EICAS COMPUTERS & SYMBOL GENERATORS RERACK T. SUBSEQUENT EICAS LT & RT BITE CARRIED OUT SATISFACTORY. UPPER EICAS DU INDICATION CHECKED NORMASDR CALA2013090991107Actuator · faultyAPU STATUS MESSAGE AFTER APU SHUTDOWN AFTER BOTH ENGINES STARTED. INLET DOOR ACT POPPING C- B INLET DOOR INOPERATIVE IN FULL OPEN POSITION. APU USEABLE, PARTS 585-4045 8102-0402 SWITCH & 563-9016 MR49506 ACTUATOR.SDR CALA2013081990552Control Unit · faultySPOILER EICAS ON LANDING, SPOILER WARNING LIGHT ON OVERHEAD PANEL. TROUBLESHOT IAW AMM. FOUND SCM 2R AT FAULT. R & R SCM 2R IAW AMM. OPS NORMAL AT THIS TIME.SDR CALA2013081390385Control Unit · faultySPOILERS EICAS AND LIGHT WITH SPOILER DEPLOYMENT ON LANDING. R & R SPOILER CONTROL MODULE NR 2R IN REF 27-09-00. OPS CHECK GOOD. MESSAGE CLEARED. OK TO CONTINUE.SDR UALA2013072205112Blocker Door · misalignedFOUND AT 11 OCLOCK LEFT ENGINE NR 1 BLOCKER DOOR MISALIGNED. INSTALLED BLOCKER DOOR. ALL CHECKED GOOD.SDR UALA2013062504393Sign · dislodgedEMERGENCY EXIT SIGN AT ROW 21 FELL OFF. SECURED EXIT SIGN.SDR UALA2013061204041Seal · leakingF/O SLIDING WINDOW SEAL WHISTLES LOUDLY. ACCOMPLISHED SEAL LEAK REPAIR IAW MM.SDR UALA2013060303837Hose · damagedRIGHT OVERWING SLIDE INFLATION HOSE DAMAGED ABOUT 18 INCHES AWAY FROM BOTTLE. R & R RT OVERWING INFLATION SLIDE HOSE IAW AMM.SDR UALA2013052903728Sdu · malfunctionedSAT VOICE EICAS MESSAGE DISPLAYED. NO SATCOM PROMPT ON FMC MENU PAGE. REPLACED SDU IAW MM. RADIO CHECKED NORMAL.SDR UALA2013052203531Isolation Valve · failedLEFT ISOLATION VALVE LIGHT ILLUMINATED. ASSOCIATED BLEED ISOLATION VALVE EICAS MESSAGE IS DISPLAYED. R & R ISOLATION VALVE IAW MM, OPS CHECKED OK.SDR UALA2013051403343Connector · unsecureUPPER FUEL CROSSFEED SWITCH DOES NOT CYCLE VALVE. SECURED CONNECTOR ON UPPER TRANSFEED VALVE. VALVE CHECKED GOOD.SDR UALA2013051303315Wire · missingRIGHT COVER COPPER WIRE BROKEN ON GENERATOR DRIVE DISC PUSH SWITCH, VERIFIED NR 2 ENGINE IDG NOT DISCONNECTED. SAFETIED COVER WITH COPPER BREAK AWAY WIRE.SDR UALA2013042202782Unknown · leakingHYDRAULIC FLUID STREAMING DOWN APU COMPARTMENT, LEAK IS COMING FROM RUDDER AREA, SUSPECT PCU OR BROKE LINE. INSPECTED AREA FOUND NO LEAKS.SDR UALA2013040902368Fastener · damagedDAMAGE FOUND ON RT WINGLET IN MID-SPAR AREA LOWER SURFACE. 8TH FASTENER OUTBOARD. SAMC TEXT: DAMAGE ALSO FOUND ON 7TH FASTENER OF MIDSPAR. DAMAGE ALSO FOUND ON FRONT SPAR 14TH FASTENER FROM INBD, DAMAGED FASTENER ON REAR SPAR 18TH FASTENER, DAMAGED FASTENERSDR UALA2013040502286B-Nut · leakingCREW O2 READS LOW, 820 PSI. FOUND SMALL LEAK ON SECOND OBSERVER O2 BOX HOSE B-NUT, SECURED, LEAK CK PER MM. NO LEAK. REPLACED CREW O2 BOTTLE PER MM. PRESSURE 1850 PSI.SDR UALA2013032801988Cover · unsecureEXIT SIGN COVER OFF OF LIGHT ASSEMBLY. INSTALLED COVER.SDR UALA2013032001717Connector · dirtyAFT FUEL CROSSFEED VALVE WILL NOT TEST. VERIFIED VALVE OPERATION OK. CLEANED CONNECTOR, PERFORMED OPERATIONAL TEST IAW AMM, TEST PASSED.SDR UALA2013031801645Terminal · looseLEFT SIDE WINDOW EICAS AND SWITCH LIGHT. WINDOW RESISTANCE CHECKED GOOD AT 18.1 OHMS. FOUND TERMINAL D LOOSE AT J8 CONTACTOR. SECURED IAW AMM 56-11-02. OPS CHECKED NORMAL IAW AMM.SDR UALA2013031801646Control Panel · failedRIGHT LAMP OF C CMD A-P ENGAGE IS OUT. REMOVED AND REPLACED MODE CONTROL PANEL IAW AMM 22-11-02, ACCOMPLISHED MCDP TEST 30 NO FAULTS, ACFT IS FULL CAT CAPABILITY.SDR UALA2013031501588Seal · leakingFIRST OFFICER`S SLIDING WINDOW SQUEAL OCCURED 6.5 HOURS AFTER TAKE OFF. NOISE TOO LOUD TO TALK OVER. REMOVED AND REPLACED FIRST OFFICER`S SLIDING WINDOW SEAL PER AMM.SDR UALA2013031101431Skin · dentedFUSELAGE SKIN DENT AT STA 654 AT STR 23R. HFEC CHECK FOUND NO CRACK, DENT IS WITHIN LIMIT PER SRM 53-00-01, OK FOR SERVICE. REPAIRED DENT, FABRICATED AND INSTALLED FILLER 2024-T3 .063 AND DOUBLER 2024-T3 .071 CLAD PER SRM 53-00-01 RPR 1 AND 53-30-01. ACP HFSDR UALA2013031101430Skin · crackedEMPENNAGE SKIN CRACKED AT BS 1657, STR 13R. REPAIRED CRACK IAW REO-G16019 REV A & ECRA 5381-01002. CF ITEM IS REQUIRED PER ECRA AS FOLLOWS. THE FUSELAGE SKIN & STR REPAIR INSTALLED PER ECRA 5381-01002 APPRX BS 1660 & S-13R RECEIVED 1ST STAGE APPV.SDR UALA2013022101047Pressure Switch · faultyRIGHT AFT FUEL PUMP LOW PRESS LIGHT NOT ON W PUMP OFF, TESTS OKAY. REPLACED RIGHT AFT BOOST PUMP LOW PRESSURE SWITCH PER AMM, OPS GOOD.