N673UA
Service difficulty reports · 346
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N673UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N673UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2012022201074Circuit Card · failedLEFT ENGINE BLEED OFF LIGHT ON AND LT ENGINE BLEED OFF EICAS MESSAGE, WITH ENGINE RUNNING, ENGINE BLEED SWITCH ON, LT AND RT ISOLATION VALVES CLOSED, A/C PACK SELECTED ON, AND DUCT PSI IS ZERO. OFF LIGHT STAYS ON WHEN N1 IS ABOVE 41 PERCENT. LT DUCT PRESSURESDR UALA2012012300473Actuator · faultyAFT ENG CROSSFEED VLV WOULD NOT OPEN WITH SWITCH IN ON POSITION, REPORTED BY CREW. REMOVED CROSSFEED ACTUATOR FOUND CROSSFEED VLV IS NOT BINDING. REPLACED AFT CROSSFEED ACTUATOR. OPERATIONAL TEST ALL SYS NORMAL. CONFERRED WITH TOMC. ACP UNWANTED FUEL TRANSSDR UALA2011121906960Hydraulic Line · looseHYDRAULIC FLUID LEAKING FROM AFT LOWER TRAILING EDGE OF RUDDER. SECURED LINE AND FITTING 'B' NUT CENTER PCA AND LEAK CHECKED OKAY.SDR UALA2011121206805Light · missingAFT EMERGENCY LIGHT ON SEAT 5H IS MISSING.SDR UALA2011120906771Antenna · failedCREW REPORTS BOTH TRANSPONDERS ARE FAULTY. REPLACED BOTH UPPER AND LOWER ATC ANTENNAS PER MM. ACCOMPLISHED SYSTEM TEST PER MM. CHECKED OKAY.SDR UALA2011120506661Cover · defectiveEMERGENCY EXIT PLACARD NEEDS TO BE REPLACED LT SIDE ACFT ROW 17. INSTALLED EMERGENCY EXIT SIGN LENS COVER AND SECURED.SDR UALA2011112706518Actuator · failedAFT FUEL CROSSFEED VALVE APPEARS INOPERATIVE. REPLACED AFT CROSSFEED VALVE ACTUATOR PER MM.SDR UALA2011112106372Light · inoperativeTWO EA AISLE LIGHTS INOP. RELAMPED, LAMP CHECKS OKAY.SDR UALA2011112106371Light · inoperativeEEL LIGHT AT SEATS 35AB. REPLACED EEL LIGHT STRIP, OP CHECKS OKAY.SDR UALA2011112106370Light · inoperativeAISLE EMERGENCY LIGHT AT APPROX SEATS 2AB INOPERATIVE. RELAMPED, OP CHECKS OKAY.SDR UALA2011112106369Light · inoperativeAISLE EMERGENCY LIGHT AT APPROX SEATS 15HJ INOPERATIVE. RELAMPED, OP CHECKS NORMAL.SDR UALA2011112106368Light · missingONE EA EEL LIGHT MISSING AT SEATS 5HJ. REPLACED LIGHT ASSY CHECKED, OKAY.SDR UALA2011112106364Light · inoperativeTWO EA AISLE LIGHTS INOP IN FWD GALLEY AREA. SHOULD READ 2 EA AISLE EMERGENCY LIGHTS INOPERATIVE. RELAMPED, OPS CHECK OKAY.SDR UALA2011112106406Actuator · faultyAPU FAULT LIGHT ON W-APU RUNNING. REPLACED APU FUEL VLV ACTUATOR PER AMM. OPERATIONAL CHECK AND FAULT LIGHT INDICATIONS NOW NORMAL.SDR UALA2011111806335Wire · unsecureSEAT 5H HAS WIRES DANGLING FROM EMER EXIT LIGHTS. SECURED WIRE, LIGHT INOP. SECURED WIRING, OP CHECKS OKAY.SDR UALA2011111706319Light · inoperativeEMERGENCY EXIT LIGHTING INOP AT SEATS 1JH THRU 5JH. FOUND FLOOR STRIP L901 JUST AFT OF DOOR 1R DEFECTIVE. NEEDS NEW STRIP. NO PCN AVAIL. ONLY ONE FLOOR STRIP IS INOP. ALL REMAINING EMERGENCY LIGHTS OP NORMAL. ORDERED LIGHT ASSEMBLY 7976-3 LIGHT ASSY 38"SDR UALA2011102705814Cover · damagedEMERGENCY LIGHTING PROTECTIVE COVER DAMAGED. REPLACED LIGHT ASSY, CHECKED GOOD.SDR UALA2011101205553Motor · failedAFT CENTER LAVATORY TOILET FLUSHING SYSTEM INOPERATIVE. REPLACED TOILET VACUUM BLOWER MOTOR, OPS CHECKED OKAY.SDR UALA2011101205542Light · looseEMERGENCY LIGHT AT SEAT 6B CAME LOOSE. REPLACED LIGHT ASSY, OPS CHECKED GOOD.SDR UALA2011101205541Light · brokenEEL LIGHTS BROKEN AT SEAT 5A AND 6A. REPLACED EEL LIGHT STRIP AT 5A, 6AB.SDR UALA2011100505402Coupling · leakingFUEL LEAKING FROM NR 1 ENGINE STRUT DRAIN AFTER ENGINE SHUTDOWN. PRESSURE CHECKED LINE AND FOUND COUPLING JUST ABOVE ENGINE FIREWALL LEAKING. REMOVED OLD O-RINGS AND PUT NEW O-RINGS IN PLACE. NEED TO REINSTALL FUEL LINE CLAMP COUPLING AND BONDING WIRE. INSDR UALA2011100305359Computer · malfunctionedICE DETECTION OFF EICAS MESSAGE. SYSTEM NOT INSTALLED IN AIRCRAFT. REPLACED LEFT EICAS COMPUTER PER MM AND LOADED DATA, CHECKED OKAY.SDR UALA2011100305358Oxygen Mask · brokenFIRST OBSERVERS O2 MASK BROKEN. REPLACED MASK ASSY.SDR UALA2011100305357Shutoff Valve · faultyLEFT ENGINE HPSOV EICAS MESSAGE. COMPLIED WITH MEL CARD, HIGH PRESSURE VALVE DEACTIVATED. REPLACED VALVE, OP CHECKED GOOD. RAN ENG PER JRH 2-6-4. BLEED SYS CHECKED NORMAL. NO MESSAGE. OP CHECKED NORMAL.SDR UALA2011092805254Light · missingSEAT MOUNTED EMERGENCY PATH LIGHTS ONE EA MISSING FROM THE FOLLOWING SEATS 1B, 6H AND 4H. REPLACED EMERGENCY LIGHT ASSEMBLIES.SDR UALA2011092105109Engine · surgesNR 2 ENGINE HAS PERFORMANCE PARAMETER SHIFT. RIGHT ENGINE CONDITION MONITORING (ECM) DETECTED A SURGE ON ROLL OUT, THIS IS A RING CASE ENGINE, VISUALLY CHECK INLET & EXHAUST, 2.5 BLEED AND 2.9 BLEED OPENINGS FOR DAMAGE OR UNUSUAL MATERIAL, CHECK IP CHECK VALVSDR UALA2011091905024Light · inoperativeSEAT 15AB AISLE EMERGENCY LIGHT ATTACHED TO SEAT IS INOP. REPORTED BY FLT ATTENDANT. COMPLIED WITH MEL CARD. REPLACED DAMAGED LIGHT, OP NORMAL.SDR UALA2011091905055Shutoff Valve · faultyCREW REPORT: R ENG HPSOV STATUS MSG ON EICAS. LOCKED CLOSED AND DEFERED PER MEL. INSTALLED NEW HPSOV. RAN ENGINE TO 80% N2 VLV WOULD NOT CLOSE. REAPPLIED MEL NEED MORE TIME TO T-S. BROKE BOLT OFF IN VLV, RPL VLV AGAIN. NO TIME TO OPS CHK VLV AGAIN, RE-APPLIESDR UALA2011091905023Fuel Cap · missingLEFT AND RIGHT FUEL RECEPTACLE CAP(S) INOPERATIVE OR MISSING. DEFERRED PER MEL. -INF- :FUELING CAPS (PCN 192-2130). REPLACED MISSING FUEL CAPS.SDR UALA2011091905022Light · missingSEAT 5B EEL LIGHT MISSING. REPLACED EEL LIGHT.SDR UALA2011082304523Smoke Detector · faultyLAV 103 SMOKE DETECTOR GREEN LIGHT IS NOT ILLUMINATED. LAV DEACTIVATED PER MEL. MEL REF: 2626M. REPLACED SMOKE DETECTOR IN LAV 103 PER MM, OPS OKAY.SDR UALA2011082204490Computer · failed3 EICAS CDU IS BLANK, OUT OF FOCUS, DISTORTED OR WRONG COLOR. OP NORM ON ALT CMPTR. (03=UPPER, 04=LOWER). CREW COMMENTS: UPPER EICAS FAILED IN AUTO N WORKS FINE WITH RIGHT COMPUTER. MAINT TEXT: AT LEAST 7X HITS ON THIS ITEM. REPLACED EICAS COMPUTER (PCN 48SDR UALA2011081904417Altimeter · faultySTANDBY ALTIMETER VIBRATOR TOO LOUD. REPLACED ALTIMETER PER AMM, OPS CHECKED OKAY.SDR UALA2011081904416Panel · damagedLEFT INBOARD UNDERWING REAR TRAILING EDGE PANEL DAMAGED. DRILLED OUT AND COUNTER SUNK NEW PANEL, INSTALLED AND SECURED.SDR UALA2011081804405Fmu · leakingNR 2 ENG FUEL LEAKING DURING DRY MOTOR CHECK, LEAKING FROM FUEL TUBE. REPLACED SEALS FROM FUEL TUBE BETWEEN FUEL PUMP AND FUEL CONTROL, FUEL CONTROL STILL LEAKING. FOUND NR 2 FMU PLUG LEAKING. REPLACED FMU PER MM. OPS OKAY.SDR UALA2011081804404Controller · faultyLT ENG HPSOV ON DURING DESCENT. PERFORMED PNEUMATIC HEALTH CHECK PER MM. FOUND PRESS REGULATING VALVE LEAKING AT ELBOW AND CONTROL PRESS LINE, REPLACED LINE & ELBOW PER MM. REMOVED AND REPLACED HIGH PRESS CONTROLLER PER MM. OP'S CHECK GOOD.SDR UALA2011081804403Display · faultyEICAS MSG, EICAS DISPLAY IN VIEW. ACCOMPLISH CHRONIC REVIEW. REPLACED UPPER EICAS DISPLAY UNIT PER MM, OPS CHECK OKAY.SDR UALA2011081704367Circuit Card · faultyUPPER EICAS DISPLAY SHOW BLANK NO STATUS MSG. BORROW PART NR 285T0496-1 SN: D01419. INSTALLED IN M10417 POSITION IN EE COMPARTMENT FWD LEFT SIDE TUNNEL NEXT TO EICAS COMPUTERS. TEST EICAS DISPLAY NORMAL.SDR UALA2011081704366Relay · faultySQUIB R SLIDE DOES NOT TEST EVERY OTHER TIME. MAINT TEXT: TRIED RIGHT OFF-WING SLIDE BATTERY CHARGER AND BATTERY, NO HELP. SUSPECT SPOILER TEST 2 SWITCH. REPLACED K839 RELAY IN P19 CEILING PANEL. TEST 2 CHECK NORMAL.SDR UALA2011081504282Light · inoperativeEMERGENCY LIGHT INOPERATIVE AT 17AB. REPLACED LIGHT, OPS CHECKED OKAY.SDR UALA2011081504281Feeder Cable · damagedEMERGENCY LIGHT INOPERATIVE AT ROWS 20AB-23AB. REPAIRED DAMAGED FEEDER CABLE, OPS CHECKED OKAY.SDR UALA2011081504280Light · inoperativeEMERGENCY LIGHT INOPERATIVE AT 30AB. REPLACED LIGHT, OPS CHECKED OKAY.SDR UALA2011081504279Light · inoperativeEMERGENCY LIGHT AT 25HJ INOPERATIVE. REPLACED LIGHT, OPS CHECKED OKAY.SDR UALA2011081504278Light · inoperativeEMERGENCY LIGHT INOPERATIVE AT 6HJ. REPLACED LIGHT, OPS CHECKED OKAY.SDR UALA2011081504277Light · inoperativeEMERGENCY LIGHT INOPERATIVE AT 3HJ. REPLACED LIGHT, OPS CHECKED OKAY.SDR UALA2011081504276Light · inoperativeEMERGENCY LIGHT INOPERATIVE AT 1HJ. REPLACED LIGHT, OPS CHECKED OKAY.SDR UALA2011081204237Connector · intermittentSQUIB TEST FAIL ON NR 1 SYSTEM. NR 2 SYS INTERMITTENT. RESET CONNECTORS, ALL CHECKED OKAY.SDR UALA2011081104228Light · unsecureEMERGENCY PATHWAY LIGHTING AT SEAT ROWS 1AB AND 6AB, FALLING OFF. SECURED LOOSE EMERGENCY PATH WAY LIGHTING STRIP AT SEAT ROWS 1AB AND 6A.SDR UALA2011081204260Pin · bentAPU SHUTS DOWN WHEN APU PNEUMATICS IS ATTEMPTED. HAS HISTORY, DEFERRED APU BLEED. FOUND BENT PIN ON OIL PRESSURE SWITCH, PIN STRAIGHTENED, STARTED ENGINE TWICE WITH NO PROBLEMS NOTED.SDR UALA2011081104230Heat Exchanger · defectiveR IDG STATUS EICAS REPEAT. IDG AIR OIL COOLER VLV BAD VLV DEACTIVATED IN OPEN POS. ENG AIR OIL COOLER OPERATES NORMAL. REPLACED RT ENG IDG AIR-OIL HEAT EXCHANGER AND VALVE, OPS CHECK OK, NO MESSAGES OR LEAKS PER MM.
Back to N673UA