N673UA
Service difficulty reports · 346
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N673UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N673UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2011081104229Light · brokenEMERGENCY PATH LIGHTING BROKEN OFF AT SEAT ROW 4EF. REPLACED EMERGENCY PATH LIGHTING ASSY AT SEAT ROW 4EF, OPS CHECK NORMAL.SDR UALA2011081004199Pressure Switch · faultyFOUND APU FAULT ON ARRIVAL, APU AUTOSHUTDOWN. APU WILL NOT START. FAULT LIGHT ON. FOUND FILTER SWITCH FAULT REPLACED GEN DIFFERENTIAL PRESSURE SWITCH PER MM, OPS CHECKED NORMAL.SDR UALA2011072803895Bulb · missingR EMERG ESCAPE SLIDE SQUIB TEST LIGHT IS MISSING. INSTALLED SQUIB LIGHT COVER AND LIGHT BULB.SDR UALA2011072703835Light · unsecureLIGHT ON SIDE OF 30B CAME OFF. SECURED LIGHT TO SEAT ASSEMBLY.SDR UALA2011071703613Switch · intermittentEMERGENCY ESCAPE SQUIB TEST FAILS INTERMITTENT SIDE. FOUND TEST SWITCH 2 AT FAULT. INTERMITTENT DEPENDING ON AMOUNT OF FORCE USED. REPLACED TEST 2 SWITCH. TESTED OKAY,SDR UALA2011071703611Control Valve · faultyAPU AUTO SHUTDOWN ON PUSHBACK. REPLACED APU SURGE CONTROL VALVE PER MM. DRY MOTORED NR 1 ENGINE PER JRH, FOUND NO DEFECTS, APU MAINTAINED PNEUMATIC LOAD WITH NO AUTO SHUTDOWN.SDR UALA2011071703612Indicator · inoperativeLEFT MAIN TANK GAUGE AT REFUELING PANEL LOAD SELECT HUNDREDS DIGIT INOP. INDICATOR GAUGE WORKS OKAY. REPLACED INDICATOR PER MM, OPS CHECKED OKAY.SDR UALA2011071503607Blade · damagedVIBRATION IN YOKE ON GROUND. WORST ON F-O SIDE. FOUND NO VIBRATION WITH APU OFF. VISUAL INSPECTION OF APU MOUNTS, STRUTS AND BRACKETS - NO OBVIOUS DEFECTS NOTED. DUCTS AND APU EXHAUST SECURE. RAN APU, NOTED NO LOOSE OR VIBRATING ITEMS. FOUND FOREIGN IMPSDR UALA2011071503606Computer · faultyWITH CENTER AP ENGAGED RIGHT FCC ONLY PROVIDES VERTICAL GUIDANCE CMND BAR NO LATERAL GUIDANCE. REPLACED RIGHT FCC COMPUTER TESTED OKAY.SDR UALA2011070803399Light · missingSEAT 5B HAS EMERGENCY LIGHT MISSING. REPLACED SEAT LIGHT, OPS GOOD.SDR UALA2011070803398Light · inoperativeSEAT 6AB EMERGENCY LIGHTS DAMAGED INOP. REPLACED 2 EA SEAT LIGHT ASSYS, OPS GOOD.SDR UALA2011070703375Nut · missingINBOARD FLAP TRACK FAIRING FOUND BOLT LOOSE NUT MISSING FAIRING CRACKED AT 2 LOCATIONS, 2 INCHES LONG AT THE HINGE POINTS. REMOVED MID AN AFT FAIRING PER CDL 57H. REMOVED FAIRINGS ARE IN THE BULK PIT. OPERATION CHECK OF FLAPS ARE NORMAL. ACP VISUAL CHECK OSDR UALA2011070503313Light · missingSEAT MOUNTED 14AB HAS EEL LIGHTING MISSING. ALL OTHER EEL LIGHTING OKAY. REPLACED EEL LIGHT ASS'Y, OPS CHECKED OK.SDR UALA2011062303098Actuator · faultyLOWER RUDDER PCA FAILED FREEPLAY INSPECTION CHECK. ON NR 2682N00184. REMOVED AND REPLACED THE LOWER RUDDER PCA IAW MM, OPS & LEAK CHECKED GOOD. FREEPLAY CHECK GOOD IAW MM.SDR UALA2011062103051Shutoff Valve · failedNR 1 ENG FAILED PNEUMATIC HEALTH CHECK. ON NR 2682N00540 PERFORMED NR 1 ENG PNEUMATIC HEALTH CHECK, NO FAULTS FOUND, NO LEAKS NOTED. PER MM OPS CHECK NORMAL, AFTER REMOVAL AND REPLACING THE PRSOV.SDR UALA2011062103036Bulkhead · puncturedPUNCTURE IN PRESSURE BULKHEAD JUST FWD OF BS 1605.5 AT APPROX S36L (6 O'CLOCK POSITION). MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED DOUBLER, TEAR STRAP DOUBLER, AND FILLER PER EA PD67-53-030 AND EVA 80918 ON NR 2682N00227.SDR UALA2011061602959Floorbeam · corrodedCORROSION FOUND AT STATION 287, RBL 88.5 FWD OF DOOR R-1 ON FLOORBEAM. MAJOR REPAIR ACCOMPLISHED: ON PEMCO NR 2682N00490 EMP 600025 AND INSP 842. REMOVED DAMAGE AT UPPER FLOORBEAM CAP. NDT IAW B767 NDTM. NO CRACKS INDICATED. FABRICATED REPAIR STRAP PER ESDR UALA2011061302870Tee Fitting · corrodedCORROSION ON TEE FITTING AT STATION 851 TO STA 868, RBL 53. MAJOR REPAIR. FOUND AREA OUT OF LIMITS PER SRM. CUT OUT CORRODED SECTION OF TEE FITTING AT BS 851 TO 900 AND FABRICATED PARTS AT FWD AND TEE FITTING. ALL REPAIR PARTS FABRICATED PER SRM 53-00-51. SDR UALA2011050902305Battery Pack · dischargedLEFT ESCAPE SLIDE SQUIB TEST NOT WORKING. REPLACED BATTERY PACK FOR THE LEFT OVERWING ESCAPE SYSTEM POWER SUPPLY.SDR UALA2011050902304Display · faultyUPPER EICAS RT COMPUTER GOES BLANK. REPLACED UPPER EICAS DISPLAY UNIT PER AMM. OPS OKAY.SDR UALA2011050902303Transceiver · faultyNR 2 VHF SEEMS WEAK TRANSMITTING AND RECEIVING. REPLACED NR 2 VHF TRANSCEIVER PER MM, SYSTEM OPS CHECKS OKAY.SDR UALA2011041801893Microphone · intermittentMIKE ON F/O OXYGEN MASK INTERMITTENT. INTERMITTENT COM. LAST MINUTE CALL, SWAPPED F/O'S WITH 2ND OBSERVERS O2 MASK. ADJ COM CONNECTOR ON 2ND OBSERVERS O2 MASK, OPS CHECK GOOD.SDR UALA2011041501821Latch · corrodedRT OW SLIDE DOOR LATCH TEST FAILED. FOUND CORROSION IN LATCHES. REQ'D TO RPL LATCHES PER MM. RPL'D ALL RT OFF WING SLIDE DOOR LATCHES PER MM.SDR UALA2011041301782Light · missingSEAT 25H AISLE ARMREST EMERGENCY LIGHT STRIP MISSING. REPLACED LIGHT STRIP ASSY. OPERATION CHECK OKAY.SDR UALA2011041101760Overheat Loop · inoperativeR ENG OVERHEAT LOOP 2 STATUS MSG. FOUND UPPER FWD OVHT DET LOOP OPEN. REPLACED LOOP, CHECKS OKAY.SDR UALA2011032801452Pressure Switch · faultyNR 2 C ELEC HYDRO PUMP PRESS LIGHT TAKES A LONG TIME TO COME ON WITH SWITCH OFF. REPLACED NR 2 CTR ELEC PUMP PRESS SW PER MM. CHECKS GOOD.SDR UALA2011032301392Fitting · damagedVIBRATION FELT IN CLIMB THRU FL210-280, SPEED 300-330. LEFT WING INBOARD MID FLAP FITTING FOR AFT FLAP ATTACHMENT IS BROKEN. LEFT WING INBOARD FLAP AFT FLAP CANOE FAIRING REMOVED. SECURED FAIRING PER MM. RPLC'D FITTING PER SHOP MANUAL. WORK ACCOMPLISHED BY SSDR UALA2011022100871Idg · false activationLEFT GENERATOR EICAS, FLIGHT DIVERTED. REPLACED NR 1 IDG IAW MM. PERFORMED IDG OPS CHECK IAW JRH. OPS AND LEAKS CHECKED OK.SDR UALA2011022100892Starter · failedLEFT ENGINE, NO START, 2 ATTEMPTS. NO ROTATION ON 2ND ATTEMPT. FOUND NR 1 ENGINE STARTER FAILED. REPLACED STARTER AND VALVE. MOTORED NR 1 ENGINE, OPS CHECKED OK.SDR UALA2011021400760Seal · out of positionEMERGENCY EXIT AIR LEAK NOISE. EXIT WINDOW AT 20A HAS VERY LOUD PRESSURE LEAK. NOISE LEVEL INCREASED AT CRUISE. FOUND REPAIR AT FWD LOWER CORNER VERY ROUGH, SANDED SMOOTH. ALSO, OUTSIDE DOOR HANDLE SEAL NOT IN RETAINER. REINSTALLED SEAL IN RETAINER. PRESDR UALA2011012000347Switch · brokenF/O OYXGEN MASK TEST SWITCH BROKEN. R & R F/O'S O2 MASK BOX.SDR UALA2011011900330Battery Pack · inoperativeRT FWD MAIN ENTRY DOOR EMERGENCY EXIT IDENTIFIER EMERGENCY LIGHT INOP. REPLACED BATTERY PACK PER MM, OP CHECKS GOOD.SDR UALA2011011900329Wire · damagedRT FIRST CLASS EMERGENCY LIGHTS INOPERATIVE. REPAIRED WIRING AT SIDEWALL PER WDM. OP CHECKS NORMAL.SDR UALA2011010700116Light · inoperativeEMERGENCY LIGHT INOPERATIVE 1B FWD, AND 4H AFT. REPLACED EMERGENCY LIGHT ASSY, 1B FWD, AND 4H AFT CHECKED NORMAL ON GROUND.SDR UALA2010122004631Light · brokenFOUND SEAT EMERGENCY LIGHT BROKEN OR MISSING AT SEAT 25B, 35H. REPLACED EMERGENCY LIGHTS AND OPS CHECK SATISFACTORY.SDR UALA2010121704608Light · missing33H EXIT PATH LIGHT COVER CAME UP. SEAT 33H MISSING EMERGENCY LIGHT. ADJACENT UNITS OK. REPLACED EMERGENCY LIGHT AND OP-CHECK SATISFACTORY.SDR UALA2010121704607Feeder Cable · inoperativeSEAT 37AB EMERGENCY LIGHT INOP. SLAVED IN NEW LIGHT, NO HELP. SECURE POWER CABLE, OPS CHECKED OK.SDR UALA2010121304542Battery Pack · faultySQUIB TEST EMERGENCY ESCAPE TEST LIGHT FAILED. REPLACED BOTH BATTERY SUPPLIES. TEST OKAY.SDR UALA2010112904386Light · brokenEMERGENCY LIGHT BROKEN AT SEAT 21HJ. REPLACED EMERGENCY LIGHT ASSY. TEST OKAY.SDR UALA2010112904376Light · malfunctionedEMERGENCY LIGHT INOP AT SEAT 1B FWD. REPLACED EMERGENCY LIGHT ASSY, CHECKED NORMAL ON GROUND.SDR UALA2010110504110Shutoff Valve · inoperativeLEFT PACK WILL NOT STAY ON. SUPPLEMENTAL DATA UPDATE LEFT PACK INOP. SEVERAL PREV HITS, ACP CHK PER MM. CONFIRM WITH ONLINE IPC. RPL'D FLOW CONTROL CARD M863, NO HELP. RPL'D FCSOV. OPS CK NORMAL.SDR UALA2010110104024Adc · faultyLEFT NAV SYS FAILURE, RTFL REPLACED NR 1 ADC IAW MM PROCEDURE, CHECKED OK.SDR UALA2010102503939Battery Pack · inoperativeLEFT EMERGENCY SLIDE SQUIB TEST INOPERATIVE. REPLACED LT BATTERY PACK, LT AND RT SLIDE SQUIB TEST OK.SDR UALA2010101803857Light · inoperativeEMERGENCY LIGHT INOP ON SEAT 1B FWD. R & R EMERGENCY LIGHT ASSY, CHECKED NORMAL ON GROUND.SDR UALA2010101803856Line · leakingHYD HOSE LINE LEAKING ABOVE RH MAIN LANDING GEAR. REPLACED HYDRAULIC LINE. PRESSURIZED HYDRAULICS AND NO LEAKS FOUND.SDR UALA2010092003499Valve · faultyNR1 ENG FAMV FAILED PNEU HEALTH CK SECTION FOR SWITCH OPEN-CLOSE OPERATING PRESSURE RANGE. FAULTS "FAV" "BITE SW" & "WIRE FAULT" FOR L SYS. ACFT WIRING RINGS OK BETWEEN BITE MODULE & FAMV ELECTRICAL CONNECTOR (AT PYLON). REPLACED VALVE. OPS NORMAL.SDR UALA2010092103515Terminal Block · looseNR 1 LEFT WINDSHIELD J5 CONNECTOR BLOCK LOOSE. DURING ACCOMPLISHMENT OF COA 618422 FOUND WRONG LENGTH BOLT INSTALLED AND TERMINAL BLOCK LOOSE AT NR 1 LT J5 CONNECTION. REPLACED WINDOW.SDR UALA2010090803326Web · damagedDAMAGE TO MOUNT AREA FOX AUX GUIDE. REQUIRES PULL UP OF BALL MAT, PDU TO ACCESS THE REPAIR. REMOVED DAMAGE WEB AND STARTED TO REMOVE SUPPORT BRACKETS. MFG AND INSTALLED NEW WEB. ACCOMPLISHED REPAIR AND RESTORED BALL MATTS AND PDU AND OP CHECKS.SDR UALA2010090703274Shutoff Valve · faultySTARTED PNEU HEALTH CHECK ON NR 1 & 2 ENGINES. PRV FAILED. INSTALLED NEW VALVE. ALSO ACCOMPLISHED PNEUMATIC HEALTH CHECK ON NEW PRV IAW MM. TEST IS GOOD. NR 2 ENG PRSOV FAILED PNEUMATIC HEALTH CHECK. REPLACED NR 2 PRSOV IAW MM, TESTS OK, NO LEAKS.SDR UALA2010090303252Controller · faultyLT HP BLEED VALVE CYCLES ON AND OFF AT LOW POWER SETTINGS DUCT PRESS FLUCTUATES. INOPERATIVE LT HPSOV, COMPLIED WITH MEL REQUIREMENTS. REPLACED LT & RT ISOLATION BYPASS VALVES IAW MM. BITE AIR SUPPLY MODULE IAW MM. FOUND HPC FAULT. REPLACED HPC. RAN ENGIN