N677UA
Service difficulty reports · 332
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N677UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N677UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2018020900536Altimeter · reads highSTANDBY ALTIMETER READS PLUS 600 FEET AT ALTITUDE. REMOVED AND REPLACED THE STANDBY ALTIMETER IAW AMM 34-13-06-344-031. OPS CHECKED SATISFACTORY. NO DEFECTS NOTED. OK TO CONTINUE.SDR CALA2018020900549Switch · missingFA JUMPSEAT, MISSING THE EVACUATION SWITCH. R & R THE EVACUATION CONTROL PANEL IAW AMM 25-63-00, TESTED GOOD.SDR CALA2018020900548Clevis · damagedRIGHT OVERWING ESCAPE SLIDE COMPARTMENT DOOR, FWD LATCH CONTROL ROD, FWD CLEVIS IS BENT AND RUSTED. REPLACED THE CLEVIS.SDR CALA2017120804353Pin · damagedEMERGENCY EXIT LIGHTS ON SEAT 24 DEF BOTH SIDES ARE INOP. REMOVED AND REPLACED DAMAGED PIN ON CONNECTOR TESTED EMERGENCY LIGHTS ON SEAT 24 DEF OPS CK GOOD REF SWPM 20-00-12 AND AMM 33-51 -00.SDR CALA2017120804352Light · unknownFLOOR MOUNTED EMERGENCY ESCAPE LIGHTING AND 4 SMALL EXIT LIGHTS AT OVERWING EMERGENCY EXITS ARE INOP. LIGHTS OPS CHK NORMAL.SDR CALA2017120804351Sign · unknownFLIGHT DECK EXIT SIGN DOES NOT WORK WHEN OVERHEAD PANEL 5 EMERGENCY EXIT SWITCHED TO ON. REF CARD76-2333-1-6190. LIGHTS OPS CHK NORMAL.SDR CALA2017082502882Lamp · inoperativeEMERGENCY LIGHT FWD OF AFT CARGO DOOR DOES NOT OPERATE DURING EMERGENCY LIGHT TEST. REPLACED THE LAMPS. OPS CHECKED GOOD.SDR CALA2017082502881Lamp · inoperativeEMERGENCY LIGHT JUST AFT OF THE L1 DOOR IS NOT OPERATING DURING EMERGENCY LIGHT TEST. REPLACED THE LAMPS, OPS CHECKED GOOD.SDR CALA2017071702267Sign · looseEMERGENCY EXIT SIGN INOP AT FIRST ROW OF COACH. SECURED EXIT SIGN, OK FOR SERVICE.SDR CALA2017060201653Wire Harness · chafedLEFT ENGINE WIRE BUNDLE CHAFED AT PNEUMATIC LINE AFT & INBD OF FWD MOUNT. REMOVED & REPLACED WIRES W002-725/726-YR, & W002-727/725-YR IAW WDN 71-51-14 PG 1.B, BSWPM 20-10- 11, BSWPM 20-63-19 & RAN THE NR 1 ENGINE IAW JRH & AMM 71-00-00, TESTED GOOD.SDR CALA2017052701611Battery Pack · defectiveNUMEROUS EMERGENCY LIGHTS NOT STAYING ILLUMINATED MORE THAN 20 SECOND WHEN SWITCHED ON. TROUBLESHOT THE EMERGENCY LIGHTS AND REPAIR THE TIMING DELAY IAW AMM 33-51-02. OPS CHECKED GOOD IAW 33-51-02, 20 SECOND TIME DELAY OPS CHECKED GOOD IAW AMM 25-22-01, AND SDR CALA2017052701622Strap · gougedDISCOVERED TWO GOUGES ON THE LOWER END ATTACH STRAP, REPAIRED IAW SRM 53-30-01, RPR 6, PAGES 201-5.SDR CALA2017052701620Frame · damaged(AD 5310-05292-9) DURING ACCOMPLISHMENT OF AD RELATED CARD FOR LH FRAME INNER CHORD REPAIR AT STA 883.5 FRAME WAS DAMAGED AT AREA OF REPAIR. REPAIRED LT INNER FRAME CHORD AT MAIN CABIN BS 883.5 IAW UNITED ECRA 5310-07141SDR CALA2017052701619Skin · corrodedAFT WASTE SERVICE PAN ATTACH DOUBLER BS 1570, BL 0 IS CORRODED. REMOVED, FABRICATED, AND INSTALLED AFT WASTE SERVICE PAN ATTACH DOUBLER IAW DWG 146T3250 AND SRM 51-40-02, PAR 7D, FIG 12.SDR CALA2017052601567Shear Tie · corrodedAFT CARGO BAY, BS 1540 HAS CORROSION ON THE SHEAR TIE BETWEEN STRINGERS 38L & 39L, FOUND TO BE OUT OF LIMITS. REMOVED, FABRICATED, LOCATED, DRILLED AND INSTALLED A NEW SHEAR TIE IAW SRM 51-40-02, PAR 4, & ENGINEERING DOCUMENT 140T2102, TYPE PL, REV FR.SDR CALA2017052601566Shear Tie · corrodedAFT CARGO BAY, BS 1562 HAS CORROSION ON THE SHEAR TIE BETWEEN STRINGERS 39 L AND 39R. REMOVED AND REPLACED THE SHEAR TIE IAW SRM 51-40-02, PARA 4 AND 7.SDR CALA2017052601565Shear Tie · corrodedAFT CARGO BAY BS 1540 HAS CORROSION ON THE SHEAR TIE BETWEEN STRINGERS 38R AND 39R, OUT OF SRM LIMITS. REMOVED AND REPLACED THE SHEAR TIE IAW SRM 51-40-02, PAR 4.SDR CALA2017052601559Stringer · corrodedCORROSION ON STRINGER 39R AT BS 1400. REMOVED DAMAGED SECTION OF STRINGER AND REPLACED WITH REPAIR IAW SRM 53-00-03, FIG 201, REPAIR 2.SDR CALA2016112100950Light · intermittentEMERGENCY LIGHTS TURNED ON AND OFF FOR 3 SECONDS BY THEMSELVES. PERFORMED OPERATIONAL TEST EMERGENCY LIGHT IAW AMM 33-51-00-715- 001-001. OK FOR SERVICE.SDR CALA2016100700730Compressor · damagedLOW SPEED ABORT DURING TAKEOFF (80 KTS) DUE TO LOUD NOISE ON NR 1 ENGINE. NO VISIBLE EXTERNAL DAMAGE TO FUSELAGE. ALL TIRES, WHEELS AND BRAKES OK. SURGE MESSAGE ON EICAS. COMPRESSOR DAMAGE FOUND, ENGINE REPLACEMENTSDR CALA2016062700389Sensor · defectiveEICAS MSG L/E SLAT ASYM DISPLAYED, L/E LIGHT ILLUMINATED WITH THE FLAP LEVER IN 1. BOTH FLAP POINTERS ARE CORRECT. T/S IAW FIM TASK 27-81/809. FOUND S302, SLAT 10 INBD TO BE FAULTING. CONFIRMED S302 TO BE BAD IAW L/E SLAT SYSTEM HEALTH CHECK IAW AMM 27-88-SDR CALA2015092494395Transceiver · failedINITIALLY, WXR RADAR TILT & INDICATIONS ERRONEOUS WITHOUT FAIL MSG. RESET CB IAW QRH, SYS RECOVERED, WORKED NORMALLY 3 HRS & THEN FAILED WITH WX FAIL MSG DISPLAYED. DIVERTED DUE TO WEATHER & EMER DECLARED. REPLACED WEATHER RADAR TRANSCEIVER IAW AMM 34-43-01SDR CALA2015090894273Bulkhead · corrodedC53-144-01 CORROSION IN RT WW FWD BULKHEAD, STATION 955, INBD SIDE OF REAR SPAR FITTING, 4" BELOW BOTTOM EDGE OF CANTED PRESS DECK BS 955. REPAIRED CORRODED AREA IAW ECRA 5340-01 668.SDR CALA2015081194188Door Frame · cracked2.5" CRACK AT STATION 610, RBL42 FWD CARGO FLOOR STRUCTURE FRAME, LOWER DOOR STRUCTURE. R & R PN 143T8236-7 CORD IAW DWG 143T1208 SH1 & SRM 51-40-02. NO FURTHER ACTION REQUIRED.SDR CALA2015072194139O-Ring · damagedAIRCRAFT LOSING LT HYD QTY, QRH FOLLOWED, PUMPS OFF & HYD QTY STOPPED DECREASING. ACCOMPLISHED AMM FAULT TREE 29-11-815 & FOUND DPI INDICATOR LEAKING FROM O RING ON EDP PRESS MODULE. REPLACED O RINGS IAW MM 29-11-17. PRESSURIZED & CHECKED FOR LEAKS, NONE. QSDR CALA2015070694050Module · malfunctionedSEAT 1A IFE CONTROL BOX REPORTED OVERHEATED. FOUND HOT AREA AROUND SEAT 1A IFE BOX. CONNECTORS REMOVED, CAPPED & STOWED, OTHER ADJACENT COMPONENTS CONNECTORS REMOVED, CHECKED & REFITTED. NO FURTHER SMELLS EVIDENT DURING OR POST DEACTIVATION. R & R SEAT POWSDR CALA2015070294038Module · defectiveCREW REPORTED VERY HOT AIR FROM VENT AT SEAT 1A IN 1ST CLASS. 2ND CALL CREW REPORTED BURNING SMELL. DIVERSION, CHECKED THE AREA WITH A THERMAL IMAGING CAMERA, SEAT BOTTOM WAS REMOVED & THE EXPOSED IFE CONTROL BOX WAS IDENTIFIED AS HOT AT 47C WHICH WAS NOTICESDR CALA2014091892230Chiller · inoperativeAFT GALLEY SMOKE ODOR, CHILLER INOPERATIVE. R & R AFT RT GALLEY CHILLER IAW AMM 25-33-02. 28VDC PIN 6 NO 115VAC PINS 1, 2 & 3 AT CHILLER WDM 25-33-11, NO 115VAC AT RT AFT GALLEY POWER PANEL. SUSPECT RT AFT GALLEY ELCU TRIPPED. CYCLED RT UTILITY BUS SWITCH.SDR CALA2014060991251Shutoff Valve · faultyDURING CLIMB RT ENG HPSOV EICAS WITH LIGHT. REPLACED NR 2 ENG HPSOV & CONTROLLER IAW AMM 36-11-08 & 36-11-07. OPERATIONS CHECKED GOOD.SDR CALA2014022790496Unknown · smokeSMOKE IN THE CABIN, SMOKE OCCURRED AT DEPARTURE. CUSTOMERS WERE DEPLANED.SDR CALA2014020690316Fireseal · damagedE2 OTBD THRUST REVERSER UPPER FWD FIRE SEAL DAMAGED. REPLACED E2 OTBD UPPER FWD FIRE SEAL IAW CMM 71-11-56, ALL CHECKED NORMAL.SDR CALA2014010290042Fairing · damagedNR 2 ENG COMPRESSOR INTERMEDIATE CASE FAIRING AT 3 O'CLOCK POS HAS HOLE IN FAIRING. R & R 2 ENG COMPRESSOR CASE FAIRING IAW AMM. NO FURTHER DEFECTS NOTED AT THIS TIME.SDR CALA2013122793974Eec · faultyRT ENGINE EGT DROPPED TO ZERO APPROXIMATELY 12 MIN INTO FLT. EGT RETURNED TO NORMAL WITHIN 5 SEC. CONT NXT MR SAMC TEXT STBY EGT ALSO ZERO. ENG OPERATIONS NORMAL, EGT NORMAL FOR DURATION OF FLT. NEED TO CHECK ALL CONNECTIONS FOR SECURITY ESPECIALLY W6 CONNSDR CALA2013122093845Controller · inoperativeFLT DECK TEMP VERY HARD TO CONTROL, HAD TO USE MANUAL, PER CREW. FLT DECK TEMP CTRL INOPERATIVE, USE MANUAL, DEFERRED IAW MEL.SDR CALA2013121393677Hydraulic Line · leakingHYD LEAK FOUND AFT OF NR 2 ENG DRIPPING FROM PYLON. FOUND FROM THRUST REVERSER ISOLATION VLV ASSEMBLY ONE LINE LEAKING IAW 272T0242-100, IPC 78-34-07-01, FIGURE 3 ITEM 100. PERFORMED INTERIM REPAIR WITH AA FLEXIBLE LINE BACH8A08NN0161. RT ENG THRUST REVERSERSDR CALA2013121293631Actuator · faultyDURING OPERATION CHECKS OF LT DEFUEL VLV FOUND ACTUATOR NOT RUNNING SMOOTH. REMOVED ACTUATOR & VLV SEEMS TO BE OPERATING SMOOTHLY. TEMPORARY INSTALL ACTUATOR & OPERATION CHECKED AGAIN, ACTUATOR RUNNING SMOOTHLY. CANNON PLUG NOT FULLY SECURED BOLTS TEMPORARISDR CALA2013120393425Sealant · missingAT 350 AFTER 2HRS GOT A LOUD SQUEAL FOLLOWED BY A CHOO CHOO SOUND. CABIN ALT 5200 DIFF 8.3 CONTINUED UNTIL CABIN ALT 4000, DIFF 7.3 & NOISE STOP AT 3500, 6.8. NOISE WAS INVERT DIVIDER IN CAPTAIN'S WINDOW. NR 2 CAPTAIN`S OPEN ABLE WINDOW SEAL INSPECTED IAW MMSDR CALA2013120393424Idg · contaminatedIAW CALLOUT LM7758, FOUND LT IDG OIL CONTAMINATED WITH HYD FLUID. REMOVED IDG, FLUSHED SYS IAW. INSTALLED & TESTED NEW IDG IAW 24-11-0. NO OTHER DEFECTS NOTED.SDR CALA2013120293365Oxygen Mask · leakingCAPTAIN`S O2 MASK DEFECTIVE LEAKS. REPLACED MASK.SDR CALA2013110792714Door Frame · crackedAFT RT CARGO DOOR AFT SIDE OF DOOR CUTOUT FRAME WEB CRACKED & TORN BELOW E-6 EQUIPMENT RACK. REPAIRED IAW B767-300 SRM 53-00-07, REPAIR 3, FIG 201.SDR CALA2013100991907Valve · intermittentON GEAR EXTENSION, TAIL SKID LIGHT & EICAS ILLUMINATED. TROUBLESHOOTING FOUND MOTOR OPERATED VALVE FOR TAIL SKID INTERMITTENT. R & R VALVE ASSEMBLY, OPS CHECKED NORMAL.SDR CALA2013092491413Cover · unsecureEXIT COVER AT 1L FELL OFF. EXIT COVER AT DR 1L REFITTED. INSTALLATION & SECURITY CHECKED SATISFACTORY.SDR CALA2013092091300Actuator · leakingREPORTS OF FUEL LEAK FROM RT ENG DRAIN. FOUND FUEL LEAKING FROM TCC AIR VALVE ACTUATOR. R & R TCC AIR VALVE ACTUATOR IAW MM. OPERATIONS & LEAK CHECKED GOOD.SDR CALA2013090991141Valve · leakingLT CENTER LAVATORY RINSE VALVE LEAKING. WATER SHUT OFF. PLACED LAVATORY ON IAW MEL 38 -30M. WATER SHUTOFF & LAVATORY SECURED. LT AFT CENTER LAVATORY PC NR 160-9511.SDR CALA2013090991125Warning System · false activationEICAS TAIL SKID MESSAGE & LIGHT. NO DAMAGE NOTICED ON TAIL-SKID.SDR CALA2013081990537Computer · inoperativeLEFT EICAS COMPUTER INOPERATIVE. R & R LT EICAS COMPUTER. SOFTWARE VERIFIED. OPS CHECKED GOOD.SDR CALA2013081690473Audio Panel · malfunctionedOBSERVER STATION VHF RADIO DOES NOT TRANSMIT AFTER CHANNEL CHANGE. REPLACED SECOND OBSERVERS AUDIO PANEL, CHECKED OK.SDR CALA2013081690464Module · failedLOWER EICAS SCREEN LOOSES COLOR. REPLACED LOWER EICAS DISPLAY SWITCHING MODULE M10418, OPS NORMAL.SDR CALA2013081690491Audio Panel · failedOBSERVER STATION 2, VHF RADIO DOES NOT TRANSMIT AFTER CHANNEL CHANGE. REPLACED 2ND OBSERVERS AUDIO PANEL, CHECKED OK.SDR CALA2013072990043Line · leakingDURING WALK AROUND FOUND HYD LEAK LT WING,TROUBLESHOT TO HYD LINE. LINE HAS TWO PIN HOLES, REQUIRES REPLACEMENT. R & R LEAKING HYD LINE IN LT WING. LEAK CHECKED GOOD.
Back to N677UA