SDR UALA2011022800967Knob · brokenKNOB ON HEADING ON MCP FELL OFF. REPLACED MODE CONTROL PANEL SYSTEM. SERVICEABLE PER MM.Feb 25, 2011 · N677UA · Boeing 767322 · Autopilot ComputerSDR UALA2011022400937Smoke Goggles · brokenCREW REPORTED ONE COCKPIT SMOKE GOGGLE BROKEN. REPLACED 2ND OBSERVER SMOKE GOGGLE.Feb 23, 2011 · N677UA · Boeing 767322 · Emergency EquipmentSDR UALA2011021700822Light · inoperativeSEAT MOUNTED EMERGENCY LIGHT INOP AT SEAT 35AB IAW A-CHECK. REPLACED LIGHT ASSY, OP CHECK NORMAL.Feb 17, 2011 · N677UA · Boeing 767322 · Emergency LightingSDR UALA2011021700821Lamp · inoperativeLT AND RT AISLE CEILING MOUNTED EMERGENCY INOP AT 11AB AND 11HJ. RELAMPED, OP CHECK NORMAL.Feb 17, 2011 · N677UA · Boeing 767322 · Emergency LightingSDR UALA2011012500403Pump · failed"LT HYD PRI PUMP" EICAS MESSAGE. REPLACED LT ENG EDP IAW MM. REPLACED PRESSURE AND CASE DRAIN FILTERS. NO METAL NOTED.Jan 25, 2011 · N677UA · Boeing 767322 · Hydraulic Pump (Electric/Engine), MainSDR UALA2011011000148Module · leakingDRIPPING HYDRAULIC FLUID OUT OF RIGHT PYLON. REPLACED ACMP FILTER MODULE PER MM, OP CHECKED OKAY.Jan 9, 2011 · N677UA · Boeing 767322 · Hydraulic System, MainSDR UALA2010121004521Controller · malfunctioned'AUTO INOP' LIGHT ILLUM EICAS MSG'CABIN AUTO INOP & CABIN ALT AUTO 1 & 2 DISPLAYED. OPS IN MANUAL MODE WAS OK. REPLACED AC MOTOR 1 AND CABIN PRESSURE CONTROLLER 1 TEST AND OPS CHECKED OK.Dec 10, 2010 · N677UA · Boeing 767322 · Cabin Pressure ControllerSDR UALA2010112204310Anti-Ice Valve · faultyRIGHT ENG ANTI-ICE INTERMITTENT. VALVE FOUND FAULTY. ENG ANTI-ICE VALVE REPLACED. VALVE OPERATIONAL CHECK NORMAL.Nov 21, 2010 · N677UA · Boeing 767322 · Engine Anti-Icing SystemSDR UALA2010112204308Fan · faulty"FWD EQ EXH FAN" MSG DISPLAYED. CANNOT GET STATUS MSG TO CLEAR. REPLACED FAN, OPS NORMAL.Nov 20, 2010 · N677UA · Boeing 767322 · Air Distribution FanSDR UALA2010111004170O-Ring · leakingCTR HYD LEAK, FLIGHT DIVERTED. CENTER HYD QTY DROPPING TO .49. REFILL EICAS CENTER HYD SYS TURNED OFF. LEAKING O-RING ON RT CENTER HYDRAULIC ACCMP WAS CHANGED.Nov 10, 2010 · N677UA · Boeing 767322 · Hydraulic System, MainSDR UALA2010110804154B-Nut · leakingOIL LEAK NR 1 ENGINE AT B-NUT ON LARGE SUPPLY LINE AT FUEL OIL COOLER. SUPPLEMENTAL DATA UPDATE SECURED LINE. MOTORED NR 1 ENGINE, NO ACTIVE LEAKS NOTED AT THIS TIME.Nov 6, 2010 · N677UA · Boeing 767322 · Engine Fuel DistributionSDR UALA2010110804153Battery · dischargedFOUND APU BATTERY UNDER VOLTAGE 13V. REPLACED BATTERY, OPS CHECK OKAY. APU STARTS NORMALNov 6, 2010 · N677UA · Boeing 767322 · Battery/Charger SystemSDR UALA2010101403818Start Valve · inoperativeACP AN OPS CHECK OF THE RIGHT ENG START VALVE PRIOR TO DEPT. MANUAL START. START VALVE PARTIALLY OPEN DURING START CYCLE. REPLACED START VALVE, TEST OKAY.Oct 13, 2010 · N677UA · Boeing 767322 · Engine Start Valves/ControlsSDR UALA2010100703728Access Panel · missingNR2 ENG 446AR STRUT ACCESS PANEL MISSING. REPLACED DOOR ASSY.Oct 7, 2010 · N677UA · Boeing 767322 · Nacelle/Pylon, Main FrameSDR UALA2010100703723Smoke Goggles · contaminatedF/O SMOKE GOGGLE STORAGE BIN FULL OF LIQUID. REPLACED GOGGLES. CLEANED AREA.Oct 6, 2010 · N677UA · Boeing 767322 · Emergency EquipmentSDR UALA2010100403672Light · inoperativeEMERGENCY EXIT LIGHTS ON SEATS 23H AND 6H ARE INOP. R & R EMERGENCY EXIT LIGHTS AT SEATS 6H AND 23H IAW AMM. OPS CHECKED GOOD IAW AMM.Oct 2, 2010 · N677UA · Boeing 767322 · Emergency LightingSDR UALA2010100403671Light · no testCOCKPIT EMERGENCY LIGHTS FAILED OPS CHECKS. TROUBLESHOT PORTABLE FLIGHT DECK EMERGENCY LIGHT CONTROL CIRCUIT IAW WDM. REPLACED FLIGHT DECK PORTABLE EXIT LIGHT WITH A SERVICEABLE UNIT IAW MM AND OPS CHECK GOOD.Oct 2, 2010 · N677UA · Boeing 767322 · Emergency LightingSDR UALA2010100403670Battery · dischargedEMERGENCY CEILING LIGHT AT ROW 3HJ VERY DIM. CHARGED BATTERY IAW MM AND OPS CHECKED GOOD AT SEAT ROW 3HJ ON NON ROUTINE 2273N0 0151.Oct 2, 2010 · N677UA · Boeing 767322 · Emergency LightingSDR UALA2010100403669Battery Pack · faultyEMERGENCY LIGHTS BATTERY PACKS AT SEATS 23AB & JK, FAILED. R & R BATTERY PACKS FOR EMERGENCY LIGHTS AT SEAT ROW 23AB AND 23JK PER MM, AND OPS CHECK GOOD ON NON ROUTINE 2273N00390.Oct 2, 2010 · N677UA · Boeing 767322 · Emergency LightingSDR UALA2010100103637Valve · failedRIGHT PACK LOW LIMIT VALVE FAILED CHECK. REMOVED AND REPLACED LOW LIMIT VALVE IAW ROUTINE TASKCARD. LEAK AND OPS PERFORMED ON TASKCARD.Sep 30, 2010 · N677UA · Boeing 767322 · Cabin Cooling SystemSDR UALA2010092903608Slide · faultyTHE L2 DOOR SLIDE CABLE NOT INSTALLED ON FWD SIDE OF SLIDE PACK AT THE GIRT BAR. REMOVED AND REPLACED L2 DOOR SLIDE PACK IAW AMM.Sep 29, 2010 · N677UA · Boeing 767322 · Escape SlideSDR UALA2010092903607Controller · faultyNR 2 ENG HPC FAILED PNEUMATIC HEALTH CHECK. REMOVED AND REPLACED NR 2 ENG HPC, OPS CHECK GOOD IAW.Sep 29, 2010 · N677UA · Boeing 767322 · Pneumatic Distribution SystemSDR UALA2010092803584Controller · failedNR1 ENG HPC FAILED CHK. R & R NR1 ENGINE HIGH PRESSURE CONTROLLER, OPS CHECK GOOD.Sep 27, 2010 · N677UA · Boeing 767322 · Pneumatic Distribution SystemSDR UALA2010091003352Washer · corrodedRT OVERWING SLIDE COMPARTMENT FWD DOOR LATCH ACTUATOR PIVOT LINK JUST FWD OF ACTUATOR, CORRODED AT ROD END. REMOVED SURFACE CORROSION AND REPLACED WASHER.Sep 9, 2010 · N677UA · Boeing 767322 · Escape SlideSDR UALA2010090203225Fitting · leakingEICAS MESSAGE LT GEN DRIVE DISPLAYED. GEN DRIVE LIGHT ILLUMINATED GEN DRIVE DISCONNECTED. FOUND LT IDG OIL SERVICE FITTINGS LEAKING. ACP 5 MIN IDLE RUN RECONNECTED LT IDG AND SERVICED IDG, FREQ AT 403, VOLTS 116, OUT 87, RISE 6 RESAFTIED DISC SWITCH.Sep 2, 2010 · N677UA · Boeing 767322 · AC Generator-AlternatorSDR UALA2010090203224Valve · faultyAPU VALVE FAILED TO OPEN FULLY. DUCT PRESSURE ONLY 5 PSI WITH BLEED SWITCH SELECTED OPEN. REPLACED APU AIR SUPPLY SHUTOFF VALVE. OPS CKS NORMAL.Aug 31, 2010 · N677UA · Boeing 767322 · Pneumatic Distribution SystemSDR UALA2010081903053Indicator · faultySTBY ATTITUDE INDCATOR INDICATES 2.5-3.0 DEGREES AND WHEN COMPARED TO ATTITUDE OF EHSI ON STBY ATTITUDE INDICATOR. REPLACED STBY ATTIDUDE INDICATOR IAW MM AND ACCOMPLISHED TEST IAW MM. INDICATOR OPS CHECKED OK.Aug 19, 2010 · N677UA · Boeing 767322 · Attitude and Direction Data SystemSDR UALA2010081202945Controller · faultyWINDOW EICAS MSG DISPLAYED. SUPPLEMENTAL DATA UPDATE POSN 4 (1-L FWD,2=L SIDE,3= R FWD,4=R SIDE). INOP LGT ILLUM. INOP LGT DID NOT EXTING WHEN SW WAS RECYCLED TO OFF THEN ON. REPLACED WHCU. OPS NORMAL.Aug 10, 2010 · N677UA · Boeing 767322 · Windshield/Door Rain/Ice RemovalSDR UALA2010072202620Light · inoperativeEMERGENCY EXIT LIGHT AT 21HJ IS INOPERATIVE. REPLACED LIGHT STRIP, OPS NORMAL.Jul 22, 2010 · N677UA · Boeing 767322 · Emergency LightingSDR UALA2010061402088Computer · faultyLOWER EICAS DISPLAY BLANK. REPLACED DISPLAY NO HELP. FOUND LT CMPTR BLANKS LWR DISPLAY AFTER PWR SWITCHING,OK ON RIGHT. HAS HISTORY. EICAS COMPUTER IN FLIGHT DECK. REPLACED LT EICAS COMPUTER. OPS ARE GOOD.Jun 12, 2010 · N677UA · Boeing 767322 · Central WarningSDR UALA2010061102052Controller · malfunctionedAPU BITE MSG WILL NOT ERASE. REPLACED APU CONTROLLER IAW MM, CKS GOOD.Jun 11, 2010 · N677UA · Boeing 767322 · APU ControlsSDR UALA2010061102049Hose · kinkedCAPTS O2 MASK LOSES 10 PSI EVERY :02. DURING TROUBLESHOOTING, FOUND 2ND OBSERVER'S O-2 SUPPLY HOSE KINKED, LEAKING AT CROSS THREADED TEE FTG. REPLACED SUPPLY HOSE, PCN=192-2103 P/N 38001-606. REPLACED OTBD TEE FITTING, PCN =710-2303. ACP POST INSTALLATION LEAKJun 11, 2010 · N677UA · Boeing 767322 · Crew Oxygen SystemSDR UALA2010061102048Oxygen Mask · leakingO2 MASK LEAKING. REPLACED CAPTAIN'S 02 MASK. CAPT'S O2 MASK OPS CHECKS GOOD. O2 PRESSURE IS WITHIN DISPATCH LIMITS.Jun 10, 2010 · N677UA · Boeing 767322 · Crew Oxygen SystemSDR UALA2010060301922Apu · faultyAPU AUTO SHUTDOWN WHEN PACKS TURNED OFF, PRIOR TO ENG START. PNEU PRESS DROPS CLOSE TO ZERO WHEN PACKS SWITCHED OFF. REPEAT W-U. BIT CONTROLLER. FOUND REVERSE FLOW FAULT. REPLACED APU. CLEARED CONTROLLER FAULT. WITH ELEC AND PNEU LOAD, UNABLE TO DUPLICATE SHUJun 1, 2010 · N677UA · Boeing 767322 · APU ControlsSDR UALA2010060101890Control Valve · faultyAPU SHUTDOWN DURING ENGINE START RT AFTER BOTH PACKS WERE TURNED OFF. REPLACED INLET TEMP SENSOR AND APU OPERATES NORMAL WITH LOAD ON AND OFF. AFTER AUTO SHUTDOWN AGAIN REPLACED SURGE VALVE AND FLOW CONTROL MODULE. OPS CHECKS GOOD.May 29, 2010 · N677UA · Boeing 767322 · APU Core EngineSDR UALA2010052801839Filter · dirtyEQ COOLING FAULT, RTFL. REMOVED EQUIPMENT COOLING AIR CLEANER, CLEANED AND REINSTALLED CLEANER. RAN EQUIPMENT COOLING IN NORMAL MODE. NO MESSAGES DISPLAYED. PERFORMED EQUIPMENT COOLING TEST. ALL FINDINGS NORMAL.May 27, 2010 · N677UA · Boeing 767322 · Air Distribution SystemSDR UALA2010052601817Unknown · odorMID F/A REPORTED FUEL TYPE ODOR LOCATED AT SEATS 24 AND 25 H,J. REMOVED SIDEWALL PANELS LOWER DADO PANELS AND CARPET, NO FUEL SMELL EVIDENT.May 25, 2010 · N677UA · Boeing 767322 · Air Distribution SystemSDR UALA2010051901676Indicator · intermittent4 EICAS CRT GOES BLANK INTERMITTENTLY. OP NORM ON ALT COMPUTER (03=UPPER, 04=L0WER, 05=UPPR & LOWER). REPLACED LWR EICAS UNIT DISPLAY IAW MM. UNIT CHECKS OK. PAPER WORK IN LOG BK. SHIPPING CONTAINER IN BULK PIT.May 18, 2010 · N677UA · Boeing 767322 · Flight Environment DataSDR UALA2010041901297Valve · faultyRT ENG BLEED LGT & RT ENG PRV EICAS MSG DURING CRUISE, WITH ENG BLEED SW ON, & ENG RUNNING. L & R DUCT PSI ARE. LT DUCT PRSS IS 24PSI RDUCT PRSSR IS 3 PSI. NR 2 ENG PRESS REV VALVE IS DEFECTIVE. NEEDS TO BE REPLACED. REPLACED NR 2 ENG PRESSURE REGULATING VAApr 16, 2010 · N677UA · Boeing 767322 · Pneumatic Distribution SystemSDR UALA2010041401260Blocker Door · cutNR 1 ENGINE BLOCKER DOOR AT THE 1130 POSITION HAS A 3 INCH LONG BY 1 INCH DEEP CUT. REMOVED BLOCKER DOOR IAW CDL 78CB INSP REMAINING AREA AND AFT FOUND NO MORE DAMAGE. REV DRAG LINK AND ASSOC HARDWARE FOR BLOCKER DOOR IN LOB BOX. REPLACED BLOCKER DOOR AT 11:Apr 14, 2010 · N677UA · Boeing 767322 · Engine Thrust ReverserSDR UALA2010041401259Case · fodLOOSE METAL PIECE WEDGED AGAINST A BRACE ON THE EXHAUST SIDE OF THE LT ENGINE AT 11:30 POS PART WAS FACE OF COMPRESSOR INTERMEDIATE CASE FAIRING. REMOVED METAL. REPLACED COMPRESSOR INTERMEDIATE CASE FAIRING IAW MM.Apr 14, 2010 · N677UA · Boeing 767322 · Turbine Engine Compressor SectionSDR UALA2010040501106Sign · inoperativeFLIGHT DECK EMERGENCY EXIT LIGHT ILLUMINATES WITH POWER OFF AND EMERGENCY LIGHTS DISARMED. REPLACED SIGN, NO HELP. NO LIGHTS AT ALL. ON OR OFF. A PIECE CAME OFF OF MOUNT BASE. REPLACED MOUNT BASE AND LIGHT ASSY, OP CK OK.Apr 2, 2010 · N677UA · Boeing 767322 · Emergency LightingSDR UALA2010031700892Valve · faultyFL390 DUCT PRESS SPLIT: L= 20 PSI, R= 45-50. REPLACED PRV ON LEFT ENGINE. GROUND RUN CHKS BOTH LEFT & RIGHT DUCT PRESSURES MATCHED APPROX 33PSI.Mar 17, 2010 · N677UA · Boeing 767322 · Pneumatic Distribution SystemSDR UALA2010031500872Valve · malfunctionedAPU BLEED DOES NOT INCRS FOR ENG START. MAX BLEED PRESS 15 PSI. ENG MAX MOTOR 20PCT N2. WITH PACKS OFF, MOTORED ENG, REACHED 22 PERCENT N2, 20 PSI DUCT PRESSURE REACHED. REPLACED APU FLOW SENSING MODULE, NO HELP. REPLACED SURGE VALVE DUCT PRESS 32 PSI UNLMar 14, 2010 · N677UA · Boeing 767322 · APU Bleed Air SystemSDR UALA2010031500871Actuator · malfunctionedENGINES STARTED NORMALLY IN DEN HOWEVER APU DUCT PRESSURE WAS 18 PSI. ACTUATOR FOUND FAULTY. REPLACED APU INLET GUIDE ACTUATOR. OPS NORMAL.Mar 13, 2010 · N677UA · Boeing 767322 · APU Bleed Air SystemSDR UALA2009122103938Light · out of positionSEAT 2B EMERGENCY LIGHT MISSING. LIGHT IS OUT OF POSITION . INSTALLED NEW SEAT EMERGENCY LIGHT STRIP. OPS CHECK GOOD.Dec 19, 2009 · N677UA · Boeing 767322 · Emergency LightingSDR UALA2009122103933Light · inoperativeMID AND AFT GALLEY FLOOR EMERGENCY LIGHT INOPERATIVE. LIGHTS FOUND DEFECTIVE. REPLACED LIGHT ASSY. TESTS OKAY.Dec 19, 2009 · N677UA · Boeing 767322 · Emergency LightingSDR UALA2009120703760Slide · out of rigDOOR 1 RT SLIDE LT SIDE COMING OUT OF PAN. WILL NEED SLIDE REPLACEMENT. REPLACED & INSPECTED 1R SLIDE-RAFT ASSY INSTALLATION.Dec 6, 2009 · N677UA · Boeing 767322 · Escape SlideSDR UALA2009092503019Controller · malfunctionedAPU WON'T START. TRIED TWO TIMES. APU FAULT ON EICAS. FOUND APU BATT NORMAL AND NO FAULTS RECORDED AT APU CONTROLLER. RESET APU CONTROLLER, APU STARTS NORMAL. NFF. DEEMED OK FOR SERVICE.Sep 23, 2009 · N677UA · Boeing 767322 · APU ControlsSDR UALA2009091802948Brake · malfunctionedABORTED TAKEOFF AT APPROX 120 KNOTS DUE TO RUNWAY INCURSION. FOUND 2 FWD TIRE FUSE PLUG BLOWN, REPLACED 2 FWD TIRE. REMOVED AND REINSTALLED 2F BRAKE ASSY. REMOVED & REINSTALLED ANTI SKID TRANSDUCER. ACPD NR 1 FWD AXLE ASSY HIGH ENERGY STOP INSP NR 1F TIRE, Sep 18, 2009 · N677UA · Boeing 767322 · Landing Gear Brake System
Back to N677UA