N679CA
Service difficulty reports · 219
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N679CA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N679CA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWIA202053177Strap · corrodedCORROSION ON FLOOR STRUCTURE STRAP FS 364 LBL 9. C-CHECK RO 10/9/2020. REMOVED FLOOR STRUCTURE STRAP (SHIM) AND INSTALLED REPLACEMENT SHIM P/N: SH670-32167-3 AT FS 364 LBL-9, REF SRM AND DWG. COMPLIED WITH SKYWEST TASK CARD.SDR SWIA202053176Strap · corrodedCORROSION ON FLOOR STRUCTURE STRAP FS 333 RBL 9. C-CHECK RO 10/9/2020. REMOVED FLOOR STRUCTURE STRAP (SHIM) AND INSTALLED REPLACEMENT P/N SH670-32167-3, REF CRJ900 SRM AND DWG.SDR SWIA202053175Strap · corrodedCORROSION ON FLOOR STRUCTURE STRAP FS 349 LBL 9. C-CHECK RO 10/9/2020. REPLACED FLOOR STRAP (PACKER) WITH NEW AT FS 349 LBL 9, REF CRJ-900 SRM.SDR SWIA202053174Seat Track · corrodedFS 677-720 RT SEAT RAIL STRUCTURE CORRODED. C-CHECK RO 10/9/2020. REMOVED AND REPLACED THE RT SEAT RAIL STRUCTURE (SEAT TRACK RETAINER U-CHANNEL) BETWEEN FS 677.00 TO FS 720.00 WITH NEW SEAT RAIL STRUCTURE (SEAT TRACK RETAINER U-CHANNEL), REF CRJ900 SRM AND SDR SWIA202053173Seat Track · corrodedSEAT TRACK AT FS 565 RBL 9 CORRODED. C-CHECK RO 10/9/2020. EVALUATED SEAT TRACK AT FS 565 RBL 9, SEAT TRACK FOUND TO BE OUT OF LIMITS WITH SEVERAL TYPES OF DAMAGES. ONLY A SINGLE SECTION OF CROSS-SECTION AND TYPE OF DAMAGE IS ALLOWED TO BE REWORKED, REF CRJSDR SWIA202053172Seat Track · corrodedSEAT TRACK AT FS 693 RBL 9 CORRODED. C-CHECK RO 10/9/2020. SEAT TRACK FROM FS 661.00 +32 TO FS 693 RBL 9 FOUND TO HAVE CORROSION DAMAGE ON MORE THAN ONE ELEMENT OF PART MAKING IT OUT OF LIMITS, REF CRJ900 SRM. REMOVED CORRODED SEAT TRACK, REF CRJ900 AMM ANDSDR SWIA202053171Floor Support · corrodedRT FLOOR SILL AT FS 693 CORRODED. C-CHECK RO 10/9/2020. REPLACED RT FLOOR SILL AT FS 693 WITH NEW SILL, REF DWG AND CRJ-900 SRM. SEE CONTINUATION CARD FOR DETAILS. COMPLIED WITH.SDR SWIA202053170Seat Track · corrodedSEAT TRACK AT FS 661+46 LBL 9 CORRODED. C-CHECK RO 10/9/2020. REMOVED DAMAGED SEAT TRACK AT FS 661.00+46 ON LBL 9, REF CRJ-900 AMM. INSTALLED NEW SEAT TRACK AT FS 661.00+46 ON LBL 9, REF CRJ-900 AMM. SEE CONTINUATION CARD FOR DETAILS. REPLACED HARDWARE ASSDR SWIA202053169Seat Track · corrodedLT SIDE SEAT RAIL MOUNT STRUCTURE FS 693 CORRODED. C-CHECK RO 10/9/2020. REMOVED CORROSION, REF CRJ-900 SRM ON LT SEAT RAIL RETAINER FROM FS 693, REF CRJ-900 SRM. RESTORED FINISH TO WORKED AREA, REF CRJ-900 SRM. SEE CONTINUATION CARD FOR DETAILS.SDR SWIA202053168Drag Angle · crackedAFT DRAG ANGLE HAS POSSIBLE CRACK. C-CHECK RO 10/9/2020. REPLACED PAX DOOR AFT STAIR WEB DRAG ANGLE WITH NEW ANGLE, REF CRJ-900 SRM.SDR SWIA202053167Seat Track · corrodedLT SIDE SEAT RAIL FS 693-720 CORRODED. C-CHECK RO 10/9/2020. REMOVED CORROSION FROM LT SIDE SEAT RAIL BETWEEN FS 693.00 AND FS 720.00, REF CRJ900 SRM. FOUND TO BE OUT OF LIMITS, REF CRJ900 SRM AND BOMBARDIER STANDARDS MANUAL. REMOVED CORRODED SIDE SEAT RAISDR SWIA202053166Seat Track · corrodedLT SIDE SEAT RAIL MOUNT STRUCTURE CORRODED AT FS 797. C-CHECK RO 10/9/2020. REMOVED AND INSTALLED NEW SEAT RAIL RETAINER, REF CRJ-900 SRM. SEE CONTINUATION CARD FOR DETAILS OF WORK PERFORMED.SDR SWIA202053165Seat Track · corrodedRT SIDE SEAT RAIL FS 847 CORRODED. C-CHECK RO 10/9/2020. RT SIDE SEAT RAIL FS 847 CORROSION IS INCORRECT LOCATION CORROSION ACTUALLY LOCATED AT 830.40. ENTIRE SEAT RAIL SECTION REPLACED WHICH INCLUDES FS 847 AND FS 830.40. REPLACED RT SIDE SEAT RAIL WITHSDR SWIA202053164Intercostal · corrodedPAX DOOR DD6 INTERCOSTAL HAS CORROSION, MARKED. C-CHECK RO 10/9/2020. REMOVED AND REPLACED PAX DOOR INTERCOSTAL DD6, REF CRJ900 SRM AND DWG. NO LEAKS NOTED AND OPERATIONS CHECKS GOOD. COMPLIED WITH.SDR SWIA202053163Seat Track · corrodedRT SIDE SEAT RAIL MOUNT STRUCTURE FS 797 CORRODED IN TWO PLACES. C-CHECK RO 10/9/2020. REPLACED THE RT SIDE SEAT RAIL RETAINER THAT COVERS FS 797, REF CRJ-900 SRM.SDR SWIA202053162Skin · corrodedPAX DOOR INNER SKIN HAS CORROSION, MARKED ON INNER SKIN. C-CHECK RO 10/9/2020. REPLACED PAX DOOR INNER SKIN, REF CRJ-900 SRM. SEE CONTINUATION CARD FOR MAINTENANCE PERFORMED.SDR SWIA202053161Seat Track · corrodedFS 752.50 RT SIDE SEAT RAIL CORRODED. C-CHECK RO 10/9/2020. REMOVED CORROSION FROM RT SIDE SEAT RAIL FROM FS 752.50, REF CRJ900 SRM. FOUND TO BE OUT OF LIMITS, REF CRJ900 SRM. REMOVED CORRODED SIDE SEAT RAIL SECTION FROM FS 752.50, REF CRJ900 AMM AND INSTASDR SWIA202053160Seat Track · corrodedSEAT TRACK FS 437 RBL 9 CORRODED. C-CHECK RO 10/9/2020. REMOVED DAMAGED SET TRACK AT FS 437.00 ON RBL 9, REF CRJ-900 AMM. INSTALLED NEW SEAT TRACK AT FS 437.00 RBL 9, REF CRJ-900 AMM.SDR SWIA202053159Seat Track · corrodedSEAT TRACK AT FS 865 LBL 9 CORRODED. C-CHECK RO 10/9/2020. REMOVED DAMAGED SEAT TRACK AT FS 865.00 ON LBL 9, REF CRJ-900 AMM. INSTALLED NEW SEAT TRACK AT FS 865.00 ON LBL 9, REF CRJ-900 AMM. SEE CONTINUATION CARD FOR DETAILS.SDR SWIA202053158Seat Track · corrodedSEAT TRACK AT 847+8.40 LBL 9 CORRODED. C-CHECK RO 10/9/2020. REMOVED DAMAGED SEAT TRACK AT FS 847.00+8.40 ON LBL 9, REF CRJ-900 AMM. INSTALLED NEW SEAT TRACK AT FS 847.00+8.40 ON LBL 9, REF CRJ-900 MM. SEE CONTINUATION CARD FOR DETAILS.SDR SWIA202053157Floor Support · corrodedLT FLOOR SILL AT FS 977-1000 HAS CORROSION IN SEVERAL SPOTS. C-CHECK RO 10/9/2020. REPAIRED LT FLOOR SILLS FS 977-1000, REF CRJ900 SRM. ALL STEPS COMPLIED WITH.SDR SWIA202053156Stringer · corrodedFS 927 STR 26R AFT SIDE OF FRAME LOWER FLANGE CORRODED. C-CHECK RO 10/9/2020. REMOVED AND INSTALLED NEW FRAME SECTOR FROM FS 927, STRG 20L TO STRG 23R, PER BOMBARDIER DWG AND CRJ900 SRM AND REO. REMOVED AND INSTALLED REINFORCING ANGLE FROM FS 927 FRAME, REFSDR SWIA202053155Frame · corrodedBETWEEN FS 847.32-847.48 AT STR 27 FRAME ON AFT SIDE LOWER FLANGE CORRODED. C-CHECK RO 10/9/2020. REMOVED AND REPLACED FRAME SECTOR AT FS 847+48 BETWEEN 25L AND 25R, REF DWG AND REF CRJ900 SRM. NO LEAKS NOTED. COMPLIED WITH.SDR SWIA202053154Stringer · corrodedMAIN AVIONICS BAY STR 21L BACK-UP SILL CORRODED BETWEEN FS 310.00 AND FS 333.00. C-CHECK RO 10/9/2020. REMOVED AND REPLACED MAIN AVIONICS BAY STR 21L BACK-UP SILL BETWEEN FS 310.00 AND FS 333.00, REF BOMBARDIER DWG CRJ 900 SRM. COMPLIED WITH.SDR SWIA202053153Stringer · corrodedMAIN AVIONICS BAY STR 20R CORRODED BETWEEN FS 295.00 AND FS 310.00. C-CHECK RO 10/9/2020. REMOVED AND INSTALLED NEW STR 20R FROM FS 280.00 TO FS 319.70, REF CRJ-900 SRM AND DWG, NO LEAKS NOTED. COMPLIED WITH.SDR SWIA202053152Attach Angle · corrodedMAIN AVIONICS BAY FLOORBOARD SUPPORT ATTACH ANGLE AT FS 280.00 CORRODED. C-CHECK RO 10/9/2020. REMOVED AND INSTALLED NEW FLOORBOARD SUPPORT ANGLE AT FS 280, REF DWG CRJ900 SRM. COMPLIED WITH.SDR SWIA202053151Frame · corrodedMAIN AVIONICS BAY FS 295.00 LOWER FRAME CORRODED BETWEEN STR 26L AND STR 26R. C-CHECK RO 10/9/2020. MAIN AVIONICS BAY FS 295.00 LOWER FRAME CORROSION FOUND TO BE ON MORE THAN ONE ELEMENT IN A GIVEN CROSS-SECTION ABOVE .700 FROM RADIUS OF FRAME AND IS FOUND SDR SWIA202053150Stringer · corrodedMAIN AVIONICS BAY STR 25R CORRODED BETWEEN FS 280.00 AND FS 333.00. C-CHECK RO 10/9/2020. REMOVED AND INSTALLED NEW AVIONICS BAY STR 25R BETWEEN FS 280 TO FS 333, REF CRJ-900 SRM AND DWG, NO LEAKS NOTED. COMPLIED WITH.SDR SWIA202053149Stringer · corrodedMAIN AVIONICS BAY STR 26R CORRODED BETWEEN FS 280.00 AND FS 333.00. C-CHECK RO 10/9/2020. REMOVED AND INSTALLED NEW MAIN AVIONICS BAY STR 26R FROM FS 280 TO FS 333, REF CRJ-900 SRM AND DWG, NO LEAKS NOTED. COMPLIED WITH.SDR SWIA202053148Stringer · corrodedMAIN AVIONICS BAY STR 26L CORRODED BETWEEN FS 280.00 AND FS 333.00. C-CHECK RO 10/9/2020. REMOVED AND INSTALLED NEW MAIN AVIONICS BAY STR 26L FROM FS 280 TO FS 333, REF CRJ-900 SRM AND DWG, NO LEAKS NOTED. COMPLIED WITH.SDR SWIA202053147Stringer · corrodedMAIN AVIONICS BAY STR 25L CORRODED BETWEEN FS 280.00 AND FS 333.00. C-CHECK RO 10/9/2020. REMOVED AND INSTALLED NEW AVIONICS BAY STR 25L BETWEEN FS 280 TO FS 333, REF CRJ-900 SRM A01 AND DWG, NO LEAKS NOTED. COMPLED WITH.SDR SWIA202053146Doubler · corrodedMAIN AVIONICS BAY TCAS ANTENNA DOUBLER CORRODED BETWEEN FS 295.00 AND FS 310.00. C-CHECK RO 10/9/2020. EVALUATED REPAIR, FOUND TO BE OUT OF LIMITS. REMOVED AND REPLACED CORRODED DOUBLER, REF MHI RJ REO DWG CRJ 900 SRM AND CRJ 900 SRM. COMPLIED WITH SKYWESTSDR SWIA202053145Frame · corrodedMAIN AVIONICS BAY FS 310.00 LOWER FRAME CORRODED BETWEEN STR 26L AND STR 26R. C-CHECK RO 10/9/2020. EVALUATED DAMAGE. FRAME FOUND TO BE OUT OF LIMITS. REMOVED AND REPLACED FS 310.00 FRAME WITH NEW SPLICE FRAME REPAIR, REF CRJ 900 SRM. COMPLIED WITH SKYWESDR SWIA202053144Frame · corrodedMAIN AVIONICS BAY FS 319.70 LOWER FRAME CORRODED BETWEEN STR 26L AND STR 26R. C-CHECK RO 10/9/2020. REMOVED AND REPLACED MAIN AVIONICS BAY FS 319.70 LOWER FRAME BETWEEN STGR 25L-STGR 23R, REF CRJ900 SRM. PERFORMED PRESSURE LEAK CHECK, REF CRJ900 AMM, NO DESDR SWIA202053143Frame · corrodedMAIN AVIONICS BAY FS 349.00 LOWER FRAME CORRODED BETWEEN STR 26L AND STR 25R. C-CHECK RO 10/9/2020. REMOVED AND REPLACED MAIN AVIONICS BAY FS 349.00 LOWER FRAME BETWEEN STGR 23L-STGR 24R, REF CRJ900 SRM AND DWG. PERFORMED PRESSURE LEAK CHECK, REF CRJ900 AMMSDR SWIA202053142Frame · corrodedMAIN AVIONICS BAY FS 333.00 LOWER FRAME CORRODED BETWEEN STR 26L AND STR 26R. C-CHECK RO 10/9/2020. REMOVED AND REPLACED MAIN AVIONICS BAY FS 333.00 LOWER FRAME BETWEEN STGR 25R-STGR 25L, REF CRJ900 SRM. PERFORMED PRESSURE LEAK CHECK, REF CRJ900 AMM NO DEFESDR SWIA202053141Stringer · corrodedMAIN AVIONICS BAY STR 26R ATTACH ANGLE CORRODED BETWEEN FS 349.00 AND FS 364.00. C-CHECK RO 10/9/2020. REMOVED AND REPLACED MAIN AVIONICS BAY STR 26R ATTACH ANGLE BETWEEN FS 349.00 AND FS 364.00, REF BOMBARDIER DRWG AND CRJ 900 SRM. COMPLIED WITH.SDR SWIA202053140Intercostal · corrodedMAIN AVIONICS BAY RT LATCH-PIN INTERCOSTAL CORRODED BETWEEN FS 349.00 AND FS 364.00. C-CHECK RO 10/9/2020. REMOVED AND REPLACED MAIN AVIONICS BAY RT LATCH-PIN INTERCOSTAL, REF CRJ900 SRM AND DWG. PERFORMED PRESSURE LEAK CHECK REF CRJ900 AMM NO DEFECTS NOTEDSDR SWIA202053139Intercostal · corrodedMAIN AVIONICS BAY LT LATCH-PIN INTERCOSTAL CORRODED BETWEEN FS 349.00 AND FS 364.00. C-CHECK RO 10/9/2020. REMOVED AND REPLACED MAIN AVIONICS BAY LT LATCH-PIN INTERCOSTAL, REF CRJ900 SRM AND DWG. PERFORMED PRESSURE LEAK CHECK, REF CRJ900 AMM, NO DEFECTS NOTSDR SWIA202053138Stringer Splice · corrodedMAIN AVIONICS BAY STR 25R SPLICE AT FS 333.00 CORRODED. C-CHECK RO 10/9/2020. REMOVED AND REPLACED STGR 25R SPLICE AT FS 333.00, REF CRJ900 SRM AND DWG. PERFORMED PRESSURE LEAK CHECK, REF CRJ900 AMM, NO DEFECTS NOTED. SEE CONTINUE CARD FOR WORK PERFORMED. SDR SWIA202053137Stringer · corrodedMAIN AVIONICS BAY STR 25R (LONGERON) CORRODED BETWEEN FS 333.00 AND FS 364.00. C-CHECK RO 10/9/2020. REMOVED AND REPLACED MAIN AVIONICS BAY STGR 25R (LONGERON) FROM FS 333.00 TO FS 364.00, REF CRJ900 SRM AND DWG PRESSURE CHECK GOOD, REF CRJ900 AMM. SEE CONTSDR SWIA202053136Stringer · corrodedMAIN AVIONICS BAY STR 26R CORRODED BETWEEN FS 333.00 AND FS 364.00. C-CHECK RO 10/9/2020. REMOVED AND REPLACED MAIN AVIONICS BAY STGR 26R FROM FS 333.00 TO FS 364.00, REF CRJ900 SRM AND DWG. PERFORMED PRESSURE LEAK CHECK, REF CRJ900 AMM NO DEFECTS NOTED. SSDR SWIA202053135Stringer · corrodedMAIN AVIONICS BAY STR 26L CORRODED BETWEEN FS 333.00 AND FS 364.00. C-CHECK RO 10/9/2020. REMOVED AND REPLACED MAIN AVIONICS BAY STGR 26L FROM FS 333.00 TO FS 364.00, REF CRJ900 SRM AND DWG PERFORMED PRESSURE LEAK CHECK, REF CRJ900 AMM, NO DEFECTS NOTED. SESDR SWIA202053134Stringer Splice · corrodedMAIN AVIONICS BAY STR 25L SPLICE AT FS 333.00 CORRODED. C-CHECK RO 10/9/2020. REMOVED AND REPLACED STGR 25L SPLICE AT FS 333.00, REF CRJ900 SRM AND DWG. PERFORMED PRESSURE LEAK CHECK, REF CRJ900 AMM. NO DEFECTS NOTED. SEE CONTINUE CARD FOR WORK PERFORMED.SDR SWIA202053133Stringer · corrodedMAIN AVIONICS BAY STR 25L (LONGERON) CORRODED BETWEEN FS 333.00 AND FS 364.00. C-CHECK RO 10/9/2020. REMOVED AND REPLACED MAIN AVIONICS BAY STGR 25L (LONGERON) FROM FS 333.00 TO FS 364.00, REF CRJ900 SRM AND DWG. PRESSURE CHECK GOOD, REF CRJ900 AMM. SEE COSDR SWIA202053132Web · corrodedCORROSION ON PAX DOOR FWD WEB PANEL AROUND OPENINGS FOR PANELS 832GL, 832HL, 832JL AND ATTACH FLANGES FOR STEPS, MARKED. C-CHECK RO 10/9/2020. REMOVED CORROSION FROM FWD STAIR WEB, REF CRJ900 SRM. NO DAMAGE LIMITS ALLOWED. INSTALLED NEW FWD STAIR WEB ON STSDR SWIA202053131Intercostal · corrodedPAX DOOR INTERCOSTAL CORRODED UNDER PANEL 832FR, MARKED. C-CHECK RO 10/9/2020. REMOVED AND INSTALLED NEW INTERCOSTAL P/N 601R31902-317, REF CRJ900 SRM & DWG. NO LEAKS NOTED.SDR SWIA202053130Angle · corrodedUNDER PANEL 832AB CLOSING PLATE, NUTPLATE RETAINING ANGLE CORRODED, MARKED. C-CHECK RO 10/9/2020. EVALUATED CORRODED RETAINING ANGLE UNDER PANEL 832AB. NO DAMAGE LIMITS GIVEN FOR STRUCTURE. REMOVED CORRODED RETAINING ANGLE (BRACKET) AND INSTALLED NEW RETAISDR SWIA202053129Structure · dentedPAX DOOR LOWER FWD CORNER CAP DENTED, MARKED. C-CHECK RO 10/9/2020. UPON REMOVAL FOUND PART TO BE CRACKED AND OUT OF LIMITS, REF DWG AND CRJ900 SRM. INSTALLED NEW CORNER CAP, REF CRJ900 SRM.SDR SWIA202053128Retainer · corrodedMAIN AVIONICS BAY DOOR AFT RIGHT HAND/LEFT HAND SEAL RETAINER CORRODED. C-CHECK RO 10/9/2020. EVALUATED DAMAGE AND FOUND BOTH LT AND RT SEAL RETAINERS OUT OF LIMITS. REMOVED AND REPLACED SEAL RETAINERS, REF CRJ 900 SRM. SEE CONTINUATION CARD FOR DETAILS OF