N699AE
Service difficulty reports · 202
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N699AE' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N699AE' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR HNAA2018092600233Control Unit · failedPDIS 699 27-51 1724322 25SEP18 CHA CLOSE FLAP FAIL MESSAGE IN FLIGHT NO FLAP INDICATION ON
EICAS. CMC SHOWS FLAP ELECTRONIC UNIT FAIL.
24934 00 JDJ
HISTORY: YES. #1 CHANNEL ALREADY ON MEL.ROA SDR HNAA2018090400211Wire · brokenEMERGENCY LIGHT ON SERVICE DOOR INOP. REPAIRED BROKEN WIRE, OPS CHECK GOOD.SDR HNAA2018080200178Battery · overtempBATT 1 OV/TEMP MSG INFLT 258 DEG 79 DEG ON GATE. REMOVED AND REPLACED NR 1 BATTERY IAW AMM 24-36-01. OPS CHECK GOOD OK FOR SERVICE.SDR HNAA2018080200177Battery · overtempBATT 1 OV/TEMP MSG INFLT 258 DEG 79 DEG ON GATE. REMOVED AND REPLACED NR 1 BATTERY IAW AMM 24-36-01. OPS CHECK GOOD OK FOR SERVICE.SDR HNAA2018072300165Unknown · odorCREW NOTICED ELECTRICAL SMELL DURING CRUISE PHASE OF FLIGHT IN COCKPIT AND FWD CABIN. LASTED FOR 10 MINS AND DISSIPATED.
RAN ENGINES AND PACKS FOR 30 MIN AND RAN ELECTRICAL SYSTEMS NO ODOR NOTICED IN CABIN OR COCKPIT. INSPECTED FWD CABIN FOR ANY ELECTRICAL ANSDR SIMA20180704005Hydraulic System · lowENROUTE NR 1 HYD SYS WENT INTO YELLOW WITH HYD LOW QTY EICAS. SERVICED NR 1 HYD SYS IAW AMM 12-13-01 OK FOR SERVICE.SDR SIMA20180606014Fitting · crackedNR 1-2-3-5 LT ISLE FLOOR LIGHT EXTRUSION CRACKED. REMOVED AND REPLACED NR 1,2,3, AND 5 LT ISLE FLOOR LIGHT EXTRUSIONS IAW AMM 33-50-12.SDR SIMA20180606012Skin · crackedRT AFT FUSELAGE HAS A SKIN CRACK AT FRAME 75 ABOVE STRINGER 2R. RAI SERVICEABLE DOUBLER FOR SKIN REPAIR AT FR 75R IAW SRM 53-31-01.SDR SIMA20180606015Battery · dischargedNR 2 EMERGENCY LIGHT BATTERY INOP. REMOVED AND REPLACED NR 2 EMERGENCY LIGHT BATTERY AND CHARGER IAW WC 33-700-19. OP CHECK GOOD.SDR SIMA20180606010Yoke · crackedLT PYLON ENGINE FORWARD LOWER YOKE CRACKED. (BEHIND LOWER FWD ENG MOUNT). REMOVED UNSERVICEABLE AND INSTALLED NEW LT PYLON ENGINE FORWARD LOWER YOKE IAW EO EM-54MR-386.SDR SIMA20180606009Yoke · crackedRT PYLON ENGINE FORWARD LOWER YOKE CRACKED. (BEHIND LOWER FWD ENG MOUNT). REMOVED AND REPLACED RT PYLON ENGINE FORWARD LOWER YOKE IAW EO EM-54MR-386.SDR SIMA20180606011Stringer · corrodedFR22 AND STR15R HAS CORROSION. PERFORMED FR22 STR15 REPAIR IAW ERS-EM-53MR-3332.SDR SIMA2018052118002Inverter · inoperativeFLOOR EMERGENCY LIGHT STRIPS AT ROWS 8 - 9 AND ROWS 10 - 11, AND RT AND LT OVERWING EXIT LIGHTS INOPERATIVE. REMOVED AND REPLACED THE INVERTER ASSY NR 5 IAW MM 33-50-11. OPS CHECKED GOOD .SDR SIMA2018042380007Sign · inoperativeEMERGENCY EXIT SIGN AT SEAT 12C WAS FOUND INOPERATIVE. REMOVED AND REPLACED SEAT 12C UPPER SIDEWALL EXIT SIGN IAW AMM 33-50-14-000-801-A, AND 33-50-14-400-801-A. OPS CHECKED GOOD.SDR SIMA2018041600002Charger · inoperativeDOOR EMERGENCY LIGHTS AND ONE PROXIMITY LIGHT INOPERATIVE. REMOVED AND REPLACED THE BATTERY AND CHARGER IAW AMM 33-50-04, OPS CHECKED GOOD.SDR SIMA2018033000003Light · unknownMIDDLE SECTION OF FLOOR EMERGENCY LIGHTS INOPERATIVE. AIRCRAFT PLACED ONTO APU POWER. OP TESTED THE EMERGENCY LIGHTS IAW 33-50-00. OP CHECKED GOOD. NO FURTHER FAULTS NOTED.SDR SIMA20180207001Warning Message · false activationWING ANTI ICE FAILED WHEN OVERRIDE KNOB IN THE ALL POSITION, FAULT CODE 301M0200. FOLLOWING FIM 30-11-00-810-803-A, ITEM 1, PERFORMED AN OPS CHECK IAW AMM 30-00-00. OPS CHECKED GOOD. NO MESSAGE NOTED.SDR SIMA20171212002Charger · inoperativeRH FWD OVERWING EMERG, AND OVRHD ISILE EMERG LIGHTS ARE OUT.-C/A-REMOVED AND REPLACED #2 EMER POWER SUPPLY AND CHARGER IAW EMB-145 AMM 33-50-04. OPS CHK GOOD. EMERGENCY LIGHTING BATTERY P/N 2013-1A S/N 105196SDR SIMA20170830002Battery · dischargedWHILE PERFORMING PS-1 INSPECTION FOUND NR 4 AND NR 5 FLOOR PROXIMITY EMERGENCY LIGHT STRIPS INOP. REMOVED AND REPLACED NR 3 EMERGENCY BATTERY POWER SUPPLY IAW AMM 33-50-04. OPS CHECK GOOD. EMERGENCY LIGHTING BATTERY P/N 2013-1A S/N 79752.SDR SIMA20170417002Light · inoperativeRT OVER WING EMERGENCY LAMP INOP. RELAMPED IAW AMM 33-50-10 OPS CHECK GOOD.SDR SIMA20170123004Light · inoperativeROW 12 AISLE EMERGENCY LIGHT INOP. REMOVED AND REPLACED ROW 12 AISLE EMERGENCY LIGHT IAW AMM 33-50-08. OPC GOOD.SDR SIMA20161219001Module · failedCABIN AUTO PRESSURIZATION FAIL CABIN STARTED CLIMBING DID NOT TRY MANUAL OPER. REMOVED AND REPLACED CPAM IAW AMM 21-32-01 REF ITEM NR 2 AND NR 3 THIS PAGE FOR OP CHECK.SDR SIMA20161016003Bleed Valve · failedAFTER TAKE-OFF, RECEIVED BLEED 1 LEAK EICAS MESSAGE. RAN THE CHECK LIST AND RETURNED TO DEPARTURE. FOUND ENGINE BLEED VALVE TO BE BAD. REMOVED AND REPLACED LT ENGINE BLEED VALVE IAW AMM 36-11-05-000-801-A AND 36-11-05-400-801-A. OPS CHECKED GOOD NO DEFECTS NSDR SIMA20161012001Battery Pack · inoperativeF/A REPORTS THAT CABIN FLOOR EMERGENCY LIGHT MID CABIN ARE INOPERATIVE. R & R THE NR 3 BATTERY IAW WORK CARD 33-700-19.SDR SIMA20160914003Sign · inoperativeRT OVERWING INTERIOR EXIT SIGN WILL NOT ILLUMINATE. R & R RT OVERWING INTERIOR EXIT SIGN IAW AMM 33-50-14. OPS CK GOOD.SDR SIMA20160606002Indication Sys · faultyDVT INDICATION DUE ERRONEOUS FUEL INDICATIONS ON RT FUEL TANK, DECLARED EMER. FLIGHT CREW PLACARDED RT FUEL QTY INDICATIONS INOPERATIVE MEL 28-09. REMOVED AND REPLACED TU R-4 IAW EMB 145 AMM 28-41-02. REFERENCE NRWC 699-CMH-02573. MEL RESTOREDSDR SIMA20160606003Smoke Detector · faultyBAGG EXT LIGHT & BAGG SMOKE EICAS WARNING AT GATE, THEN EICAS WARNING IMMEDIATELY EXTINGUISHED. R & R BOTH FWD & AFT SMOKE DETECTOR FROM THE CARGO COMPARTMENT IAW AMM 26-15-01. PERFORMED OPERATIONAL TEST IAW AMM 26-15-00. OPERATIONS CHECKED GOOD, NO MSG NOTSDR SIMA20160605001Fire Warning · false activationCREW RECEIVED A CARGO FIRE DETECTION WARNING. BAGGAGE COMPARTMENT SMOKE DETECTION SYS ALERTED & WAS RESET, FIRE DEPT CALLED. REMOVED BAGS. NO FURTHER ISSUES. INSPECTED CARGO COMPARTMENT AS REQUIRED & PERFORMED CARGO COMPARTMENT SMOKE DETECTOR OPERATIONS CHSDR SIMA20160517003Attach Fitting · crackedATTACH CLIP FOR CARGO RAMP SUPPORT AT FRAME 66 IS CRACKED. R & R ATTACH CLIP FOR CARGO RAMP SUPPORT AT FRAME 66 IAW SRM 51-40-02.SDR SIMA20160516002Fitting · chafedRIGHT AILERON DAMPER FITTING HAS CHAFES. REPLACED DAMPER FITTING IAW EO-EM-27MR-112.SDR SIMA20160513004Fitting · wornLEFT AILERON PCA FITTING OTBD LUG BUSHING BORE WORN. LT AILERON DAMPER FITTING IS DAMAGED. INSTALLED PCA FITTING IAW EO 3M-27MR-112. FITTING PN 145-69382-609.SDR SIMA20160513003Skin · chafedRUDDER 1 IS CHAFED 5.75" FROM UPPER HINGE LOWER CUT OUT & 5.75" FROM RT EDGE OF LE PANEL. REPAIRED DAMAGE IAW ERS-EM-55MR-426.SDR SIMA20160512003Door Sill · corrodedCARGO DOOR SILL IS CORRODED. R & R CARGO SILL IAW SRM CH 51-40-02.SDR SIMA20160511016Cleat · crackedSHEAR CLEAT AT FRAME 80L, STRINGER 7L IS CRACKED APPROX 1 INCH. R & R SHEAR CLEAT IAW SRM 51-40-02.SDR SIMA20160511008Cleat · crackedSHEAR CLEAT AT FRAME 80R, STRINGER 7R, IS CRACKED APPROX 1/2 INCH. R & R SHEAR CLEAT AT FRAME 80RT, STRINGER RT IAW SRM 51-40-02.SDR SIMA20160511012Torque Box · crackedPASSENGER DOOR INNER HANDLE TORQUE BOX HAS A 1/8" CRACK BY THE NUTPLATE ON AFT UPPER CORNER. R & R PAX DOOR INNER HANDLE TORQUE BOX IAW SRM 51-40-02.SDR SIMA20160511011Support Bracket · crackedCARGO DOOR LIFT & LOWER MECHANISM FWD SUPPORT BRACKET AT FRAME 68 RT IS CRACKED. SHOULD READ AFT SUPPORT BRACKET. R & R CARGO DOOR LIFT & LOWER MECHANISM AFT SUPPORT BRACKET IAW SRM 51-40-02.SDR SIMA20160511010Support · crackedCARGO DOOR LIFTING & LOWERING MECHANISM SUPPORT IS CRACKED. R & R CARGO DOOR LIFTING & LOWERING MECHANISM SUPPORT IAW AMM 52-32-00.SDR SIMA20160511009Floorbeam · corrodedFLOORBEAM AT FRAME 65, RIB IS CORRODED JUST ABOVE CARGO DOOR SILL. R & R FLOORBEAM IAW SRM 51-40-02.SDR SIMA20160511006Fitting · crackedFRAME 71 SHEAR CLIP UNDER LT FLOOR & WALL SUPPORT IS CRACKED. R & R SHEAR CLIP IAW SRM CH 51-40-02.SDR SIMA20160511007Support Bracket · crackedCARGO DOOR LIFT & LOWER MECHANISM FWD SUPPORT BRACKET AT FRAME 61 IS CRACKED. R & R CARGO DOOR LIFT & LOWERING MECHANISM FWD SUPPORT BRACKET AT RT FRAME 61 IAW SRM 51-40-02.SDR SIMA20160511005Support Angle · crackedRIGHT OMEGA BEAM L ANGLE SUPPORT IS CRACKED, BETWEEN FRAMES 47R & 48R. INSTALLED NEW FWD & AFT L ANGLE SUPPORTS FOR RT OMEGA BEAM IAW SRM 53-23-02 & 51-40-02.SDR SIMA20160511004Fitting · crackedFRAME 72 SHEAR CLIP UNDER LT FLOOR & WALL SUPPORT IS CRACKED. R & R FRAME 72 SHEAR CLIP UNDER THE FLOOR & WALL SUPPORT IAW SRM 51-40-02.SDR SIMA20160510007Support Angle · crackedRIGHT WING TO FUSELAGE PANEL 194ER, LOWER ANGLE SUPPORT 4 IS CRACKED APPROX 2". REMOVED DAMAGED SECTION OF LOWER ANGLE SUPPORT 4 & CUT TO FIT & INSTALLED NEW SECTION OF ANGLE IAW SRM 51-40-02 & ETN-EM-53-142.SDR SIMA20160510005Firewall · crackedAPU FIRE WALL HAS A 1/4" CRACK BY RIVET, JUST ABOVE LOWER RT APU MOUNTING POINT. COMPLIED WITH APU FIREWALL REPAIR IAW PART C OF EO-EM-53AD-1883.SDR SIMA20160510006Support Angle · crackedRIGHT WING TO FUSELAGE PANEL 194ER, LOWER ANGLE SUPPORT 3 IS CRACKED APPROX 1". R & R RT WING TO FUSELAGE PANEL 194ER, LOWER ANGLE SUPPORT 3 IAW SRM 51-40-02.SDR SIMA20160510008Support · crackedRIGHT WING TO FUSELAGE PANEL 194ER UPPER SUPPORT, BETWEEN FRAMES 48 - 49 IS CRACKED APPROX 1/4". REMOVED DAMAGED SECTION OF LOWER ANGLE SUPPORT 4 & CUT TO FIT & INSTALLED NEW SECTION OF ANGLE IAW SRM 51-40-02 & ETN-EM-53-142.SDR SIMA20160311002Panel Support · crackedRT WING FUSELAGE LATERAL FAIRING, UPPER SUPPORT CRACKED AT FS 16783.5, 6.25" LENGTH. INSTALLED NEW OVERWING LATERAL UPPER PANEL SUPPORT IAW SRM 51-40-02.SDR SIMA20160112004Roller · out of adjustSERVICE DOOR NOT OPENING FROM INSIDE OR CLOSING FROM INSIDE, LOTS OF FREE PLAY AT TOP DOOR HINGE. TRANSFERRED TO NRWC 699-DFW-02424. FOR SERVICE DOOR FOUND UPPER AFT ROLLER & LOWER FWD ROLLER OUT OF ADJUSTMENT. ADJUSTED UPPER AFT ROLLER & LOWER FWD ROLLER ISDR SIMA20151024003Flashlight · inoperativeFORWARD FLIGHT ATTENDANT FLASHLIGHT INOPERATIVE. R & R FWD FLIGHT ATTENDANT FLASHLIGHT IAW AMM 33-50-16.
Back to N699AE