N700UW
Service difficulty reports · 298
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N700UW' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N700UW' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR USAA2014052300007Power Supply · inoperativeMAINTENANCE REPORTED THE RT OVERWING EXIT SIGN & EMERGENCY AISLE LIGHTS AT ROWS 8 & 10 ARE OUT. REPLACED EPSU 12WL & BATTERY PACK AT ROW 9 SIDEWALL PANEL. ALL EMERGENCY LIGHTS CHECKED NORMAL IAW AMM 33-51-58.SDR USAA2014042100003Mount Bolt · brokenTHE RT AFT BUSTLE VELCRO WILL NOT STAY ON. FOUND RAFT PACK UPPER MOUNT BOLT BROKEN. R & R MOUNT BOLT ASSEMBLY IAW AMM 25-62-44-400-007A. ACFT OK FOR SERVICE.SDR USAA2014041700001Lanyard · out of positionSTRING HANGING OUT 1R DOOR WHEN CLOSED. REPOSITIONED GIRT BAR LANYARD.SDR USAA2014040300003Cover · missingREPORTED LENS COVER MISSING AT EMERGENCY LIGHT ROW 18. REPLACED LENS COVER FOR EMERGENCY LIGHT AT ROW 18, OK FOR SERVICE IAW AMM 33-50-00.SDR USAA2013121100002Floor Panel · delaminatedDELAMINATION ON FLOOR PANEL 221DF AT FR 21, BL 0. REPAIRED FLOOR PANEL 221DF IAW A319 SRM 53-12-00-201.SDR USAA2013110800004Terminal · unsecureCREW REPORTED SEAT 14C EMERGENCY LIGHT INOPERATIVE. MAINTENANCE REPAIRED WIRE TERMINAL ON CONNECTOR IAW SWPM 20-48-14. CHECKED OK.SDR USAA2013081900007Lens · brokenCREW REPORTED THE R2 DOOR FLOOR LEVEL EMERGENCY EXIT LIGHT BROKEN. MX REPLACED LENS COVER. OPS CHECK GOOD. REF AMM 33-51-00-710-007-A.SDR USAA2013021400004Smoke Detector · faultyCREW REPORTED A SMOKE DETECTOR FAULT AT LAV A. MAINTENANCE REMOVED AND REPLACED LAV A SMOKE DETECTOR IAW AMM 26-17-01A. OPS TEST AS REQUIRED PER 26-17-00.SDR USAA2013020100019Spring · dirtyMAINTENANCE REPORTED THE SPRING PAW IS STIFF ON FORWARD FLOOR FITTING FOR L1 GIRT BAR. MAINTENANCE REMOVED, CLEANED, LUBED AND RE-INSTALLED FORWARD FLOOR GIRT BAR FITTING ON L1 POSITION PER AMM 52-11-31-400-003A.SDR USAA2012110200018Battery · dischargedEMERGENCY FLASHLIGHT, "A" FLIGHT ATTENDANT SEAT NEEDS TO BE REPLACED. REPLACED FLASHLIGHT BATTERY. OPS CHECKED GOOD.SDR USAA2012071000011Lens · brokenEMERGENCY EXIT LIGHTING PLASTIC LENS NEXT TO DOOR 2L BROKEN. INSTALLED SERVICEABLE EMERGENCY EXIT LENS AS REQUIRED.SDR USAA2012042400015Seal · leakingPASSENGER REPORTED BURNT RUBBER ODOR AFTER TAKEOFF AND CRUISE. FLIGHT ATTENDANTS REPORT SLIGHT ODOR OF BURNT RUBBER IN AFT GALLEY. STILL AWAITING FOR FINAL CORRECTIVE ACTION. REMOVED AND REPLACED LEFT ENGINE. VENDOR TEARDOWN REPORT CONFIRMED OIL LEAKAGE INSDR USAA2012010600041Power Supply · faultyFORWARD CABIN EMERGENCY POWER SUPPLY UNIT FAULTS. REMOVED AND REPLACED FORWARD CABIN EMERGENCY POWER SUPPLY UNIT PER AMM 33-51-38. OPS CHECKED GOOD.SDR USAA2011113000008Mechanism · damagedC11 CHECK, PASSENGER / CREW DOOR 831 EMERGENCY EXIT HANDLE MECHANISM FLEXIBLE CONTROL DAMAGED. REPLACED PASSENGER / CREW DOOR 831 EMERGENCY EXIT HANDLE MECHANISM FLEXIBLE CONTROL IAW A319 AMM 52-11-22-400-001 AND EA 133893.SDR USAA2011112900056Angle · crackedC11 CHECK, THE LEFT OVERWING EMERGENCY EXIT DOOR 834 SEGMENT CRACKED BETWEEN BEAM 1 AND BEAM 3. REPLACED THE LEFT OVERWING EMERGENCY EXIT DOOR 834 SEGMENT BETWEEN BEAM 1 AND BEAM 3 IAW EO 5210Y228.SDR USAA2011112900055Angle · crackedC11 CHECK, THE RIGHT OVERWING EMERGENCY EXIT DOOR 844 SEGMENT CRACKED BETWEEN BEAM 1 AND BEAM 3. REPLACED THE RIGHT OVERWING EMERGENCY EXIT DOOR 844 SEGMENT BETWEEN BEAM 1 AND BEAM 3 IAW EO 5210Y228.SDR USAA2011080400004Power Supply · inoperativeTWO CEILING EMERGENCY LIGHTS, 2 AISLE EMERGENCY LIGHTS AND 2 AFT DOOR EMERGENCY LIGHTS INOPERATIVE. FOUND AFT EMERGENCY POWER SUPPLY UNIT (EPSU) TEST "UNIT FAULT". REMOVED AND REPLACED AFT EPSU AND BATTERY IAW AIRBUS MAINTENANCE MANUAL 33-51-38-400-001. OPSSDR USAA2011071900003Power Supply · inoperativeEMERGENCY POWER SUPPLY UNIT AFT GALLEY FAILED AND DOES NOT TEST. REMOVED AND REPLACED AFT GALLEY EMERGENCY POWER SUPPLY UNIT. OPS CHECKED GOOD.SDR USAA2011041491491Lens · missingFLT 2048 - DCA-BOS - EMERGENCY LIGHTS - EMERGENCY EXIT LIGHT LENS COVER MISSING LOWER DOOR L2. REPLACED MISSING LENS.SDR USAA2010122093203Battery · dischargedEMERGENCY LIGHT - AFT LED FLASHLIGHTS WERE INOPERATIVE. R & R AFT LT AND RT FLASHLIGHT BATTERIES. OPS CHECK WAS GOOD.SDR USAA2010120292761Battery · dischargedFLT 1007 - CLT-PIT - EMERGENCY LIGHTS - FORWARD ENTRYWAY OUTBOARD FLASHLIGHT HAS NO RED FLASH. REMOVED AND REPLACED FLASHLIGHT BATTERY. OPERATIONAL CHECK WAS GOOD.SDR USAA2010050390874Strap · misroutedCLT-DCA - EMERGENCY EQUIPMENT - YELLOW RELEASE STRAP AT R1 DOOR NOT ROUTED THRU GIRT BAR. REROUTED YELLOW RELEASE STRAP THROUGH DOOR R1 GIRT BAR IAW AMM 25-62-44.SDR USAA2009120493303Lens · missingFLT 1110 - JAX - CLT - EMERGENCY LIGHTS - LENS MISSING ON EMERGENCY EXIT LIGHT ROW 3. REPLACED MISSING LENS.SDR USAA2009061791496Wire Harness · faultyFLT 2186 - DCA-LGA - EMERGENCY LIGHTS - AFT EMERGENCY LIGHTS WILL NOT TEST. REMOVED AND REPLACED EMERGENCY POWER SUPPLY UNIT (13WL). ALSO REPLACED SEAT HARNESS 7260VC2 (801WL) FOR SEAT 18L. OPERATIONAL CHECK WAS GOOD.SDR USAA2009061591471Power Supply · no testFLT 2186 - DCA-LGA - EMERGENCY LIGHTS - AFT EMERGENCY LIGHTS WILL NOT TEST. REMOVED AND REPLACED EMERGENCY POWER SUPPLY UNIT (13WL). ALSO REPLACED SEAT HARNESS 7260VC2 (801WL) ON SEAT 18L. OPERATIONAL CHECK WAS GOOD.SDR USAA2009052791294Power Supply · dischargedLOGPAGE:4422592 - FLT 741 - PHL-DFW- EMERGENCY LIGHTS - SEVERAL AFT EMERGENCY ESCAPE LIGHTS INOPERATIVE, EMERGENCY POWER SUPPLY UNIT (EPSU) 13WL FAULTS. REMOVED AND REPLACED 13WL (EPSU) PER MAINTENANCE MANUAL 33-51-04.SDR USAA2009032590680Power Supply · dischargedFLT 1502 - CLT - DCA - EMERGENCY LIGHTS - LEFT AFT EMERGENCY POWER SUPPLY UNIT (EPSU) FAULT (ATA 33-51-38), WILL NOT RESET. REMOVED AND REPLACED AFT GALLEY EMERGENCY POWER SUPPLY UNIT. ALL EMERGENCY LIGHTS CHECKED GOOD.SDR USAA2009032390651Computer · faultyFLT 1227 - CLT-MBJ - ELECTRICAL SMELL - NR 2 SPOILER ELEVATOR COMPUTER (SEC) FAULT ACCOMPANIED WITH BRIEF STRONG HOT ELECTRICAL SMELL. REMOVED AND REPLACED NR 2 SPOILER ELEVATOR COMPUTER (SEC). OPERATIONAL CHECK WAS GOOD.SDR USAA920081560Shear Plate · corrodedPIT-S4- MAJOR REPAIR - LEVEL 2 EXFOLIATION CORROSION ON SHEAR PLATE BETWEEN FR69 TO FR70, -Y1292. REPLACED SHEAR PLATE BETWEEN FR69 TO FR70, -Y1292 IAW US AIRWAYS ENGINEERING ORDER 5307Y284 & A319 SRM 51-42-11. (S)SDR USAA920081558Beam · corrodedPIT-S4-MAJOR REPAIR - LEVEL 2 EXFOLIATION CORROSION ON R2 DOOR SILL BEAM AT FR66 TO FR68. REPLACED R2 DOOR SILL BEAM AT FR66 TO FR68 IAW A319 SRM 53-41-14 AND BOEING DWG D53480009. (S)SDR USAA920081557Floorbeam · corrodedPIT-S4-MAJOR REPAIR - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM BETWEEN FR66 AND FR68, -Y1162 TO -1292. REPLACED FLOORBEAM BETWEEN FR66 AND FR68, -Y1162 TO -1292 IAW A319 SRM 51-72-11. (S)SDR USAA920081559Floorbeam · corrodedPIT-S4-MAJOR REPAIR - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM AT FR66, -Y1292. REPLACED FLOORBEAM AT FR66, -Y1292 IAW A319 SRM 51-72-11. (S)SDR USAA920081556Floorbeam · corrodedPIT-S4- MAJOR REPAIR - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM AT FR68, -Y1182. REPLACED FLOORBEAM AT FR68, -Y1182 IAW A319 SRM 51-72-11. (S)SDR USAA920081669Pin · corrodedMINOR CORROSION ON AFT FACE OF LANDING GEAR PINTAL PIN. REPLACED LANDING GEAR PINTAL PIN. (K)SDR USAA920081523Floorbeam · corrodedPIT -S4- MAJOR REPAIR - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM AT FR66, Y1292. REPLACED FLOORBEAM AT FR66, Y1292 IAW A319 SRM 51-72-11. (S)SDR USAA920081524Floorbeam · corrodedPIT-S4 -MAJOR REPAIR- LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM BETWEEN FR66 & FR68, FROM Y1162 TO 1292. REPLACED FLOORBEAM BETWEEN FR66 TO FR68, Y1162 TO Y1292 IAW A319 SRM 51-72-11. (S)SDR USAA920081525Floorbeam · corrodedPIT - S4- MAJOR REPAIR - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM AT FR68, Y1162. REPLACED FLOORBEAM AT FR68, Y1162 IAW A319 SRM 51-72-11. (S)SDR USAA920081526Floorbeam · corrodedPIT - S4- MAJOR REPAIR - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM AT FR66, -Y1730. REPLACED FLOORBEAM AT FR66, -Y1730 IAW A319 SRM 51-72-11. (S)SDR USAA920081518Sill · corrodedPIT -S4- MAJOR REPAIR - LEVEL 2 INTERGRANULAR CORROSION ON LOWER L2 DOOR SHAPE SILL PLATE AT FR66 TO FR68. REPLACED LOWER L2 DOOR SHAPE SILL PLATE FR66 TO FR68 IAW A319 DRAWING D5348009. (S)SDR USAA920081521Floor Support · corrodedPIT -S4- MAJOR REPAIR - LEVEL 2 GALVANIC CORROSION ON FLOOR SUPPORT DUMMY RAIL AT FR68, Y630. REPLACED FLOOR SUPPORT DUMMY RAIL AT FR68, Y630 IAW A319 SRM 51-42-00. (S)SDR USAA920081520Seat Track · corrodedPIT -S4- MAJOR REPAIR - LEVEL 2 INTERGRANULAR CORROSION ON SEAT TRACK BEAM BETWEEN FR67 TO FR68, -765. REPLACED SEAT TRACK BEAM BETWEEN FR7 TO FR68, -Y765. (S)SDR USAA920081519Seat Track · corrodedPIT -S4- MAJOR REPAIR - LEVEL 2 EXFOLIATION CORROSION ON RAIL AT L2 DOOR SILL ABOVE FR67. REPLACED RAIL AT L2 DOOR SILL ABOVE FR67 IAW A319 SRM 53-41-11. (S)SDR USAA920081513Floorbeam · corrodedPIT - S4-MAJOR REPAIR - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM AT FR66, Y512. REPLACED FLOORBEAM AT FR66, Y512 IAW A319 SRM 51-42-11. (S)SDR USAA920081514Floor Support · corrodedPIT-S4 - MAJOR REPAIR - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM AT FR18 & FR20, WL 208.10, Y254. REPLACED FLOORBEAM AT FR18 & FR20, WL 208.10, Y254 IAW A319 SRM 51-72-11. (S)SDR USAA920081494Seat Track · corrodedPIT - S4-MAJOR REPAIR - LEVEL 2 INTERGRANULAR CORROSION ON SEAT TRACK BEAM BETWEEN FR67 & FR68, -Y765. REPLACED SEAT TRACK BEAM BETWEEN FR67 & FR68, -Y765. (S)SDR USAA920081461Cable · frayedPIT-S4-EES- R-1 DOOR SLIDE/RAFT ASSEMBLY ATTACH CABLE FOR GIRT SAFETY PIN FRAYED. FRAYED WIRES CUT THREAD WHICH SECURES SAFETY PIN. R-1 DOOR SLIDE/RAFT ASSEMBLY REPLACED. (S)SDR SA08039Smoke Warning · malfunctionedFLIGHT 1130, BGI-CLT - JUST AFTER TAKEOFF THE FLIGHT CREW RECEIVED AN AVIONICS SMOKE WARNING AND RETURNED TO BGI. MAINTENANCE PERFORMED AN INSPECTION OF THE AVIONICS COMPARTMENTS WITH NO EVIDENCE OF SMOKE NOTED. A SATISFACTORY OPERATIONAL CHECK OF THE EQUIPMSDR USAA920080182Seat Track · corrodedCLT - MAJOR REPAIR - RON, PILOT REPORT - CORROSION ON CABIN SEAT TRACK, BS 760 / FR 18, -Y1292. REPLACED CABIN SEAT TRACK, BS 760 / FR 18, -Y1292 IAW A319 SRM 51-72-11.SDR USAA920080179Dummy Rail · corrodedCLT - MAJOR REPAIR - RON, PILOT REPORT - CORROSION ON CABIN DUMMY RAIL, BS 709 / FR 16 - BS 760 / FR 18, -Y4. REPLACED CABIN DUMMY RAIL, BS 709 / FR 16 - BS 760 / FR 18, -Y4 IAW A319 SRM 51-72-11.SDR USAA920080178Floorbeam · corrodedCLT - MAJOR REPAIR - RON, PILOT REPORT - CORROSION ON CABIN FLOORBEAM, BS 709 / FR 16, -Y765 TO -Y1296. REPLACED CABIN FLOORBEAM, BS 709 / FR 16, -Y765 TO -Y1296 IAW A319 SRM 51-72-11.