N701UW
Service difficulty reports · 286
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N701UW' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N701UW' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA2020021329007Power Supply · no testAIRCRAFT WAS GROUNDED: DURING PS CHECK, FAILED EMERGENCY LIGHT TEST. MAINTENANCE ACCOMPLISHED TSM TASK 33-51-00-810-808-A AND FOUND EMERGENCY POWER SUPPLY UNIT AT FAULT AND REPLACED POWER SUPPLY PER AMM 33-51-38.SDR AALA201911049020Floorboard · damagedAIRCRAFT WAS GROUNDED: FLOOR PANEL CENTER AISLE OF FIRST CLASS SPONGIE. ACCOMPLISHED REPAIR ON FLOOR PANEL IAW SRM 53-12-00-300-005.SDR AALA201904259008Wire · shortedAIRCRAFT WAS GROUNDED: PILOT REPORTS RETURNED TO PHL ON ACCOUNT OF FLAP PROBLEM (FLAPS AND SLATS JAMMED AFTER TAKEOFF). EMERGENCY DECLARED. LANDED WITHOUT INCIDENT. MAINTENANCE ACCOMPLISHED TSM TASK 27-51-00-810-818-A. ACCOMPLISHED VISUAL INSPECTION OF FLAP TRSDR AALA2019031859004Hydraulic Line · leakingFLIGHT CREW REPORTED FUMES IN COCKPIT DURING DESCENT AT IDLE THRUST, WITH FULL SPEED BRAKES, BECAME SO STRONG IN THE COCKPIT THAT OXYGEN MASKS HAD TO BE DONNED DURING APPROACH AND WINDOWS OPENED FOR LANDING. MAINTENANCE ACCOMPLISHED CARDS 26L00021001, AND 26LSDR AALA201901049014Hinge Arm · wornLEFT ELEVATOR NR 4 HINGE ARM FITTING WAS WORN, RESULTING IN THE BEARING TO HAVE EXCESSIVE PLAY. THE AIRCRAFT WAS GROUNDED. REPLACED THE HINGE IAW AMM 55-16-42.SDR AALA201812189060Engine · fireFLT 1649 EN-ROUTE DCA - MCO. THE AIRCRAFT WAS GROUNDED. NR 2 ENGINE TAILPIPE FIRE AFTER SHUTDOWN. THE GROUND CREW USED A DRY CHEMICAL FIRE EXTINGUISHER TO PUT IT OUT. NO FURTHER INCIDENTS REPORTED. MAINTENANCE DETERMINED AN ENGINE CHANGE WAS REQUIRED. ASDR AALA201812049035Cover · looseAFT LEFT SERVICE DOOR SLIDE COVER WAS LOOSE. MAINTENANCE INSTALLED THE SLIDE COVER IAW AMM 25-62-50, AND PERFORMED A SATISFACTORY OPERATIONAL CHECK.SDR AALA201810229013Slide · defectiveFLIGHT ATTENDANT PANEL HAD AN R1 DOOR LIGHT BLINK DURING TAKEOFF. THE R2 SLIDE WAS HARD TO ARM. REPLACED THE R1 DOOR SLIDE IAW JC 26L00025011. OPS CHECKED OK. NO LIGHTS FOR R1 DOOR OCCURRED.SDR AALA201809079009Computer · failedFLIGHT WARNING COMPUTER NR 2 FAULTED ON ECAM SIMULTANEOUSLY WITH AN ELECTRICAL ODOR IN THE COCKPIT. ACCOMPLISHED QUICK RESPONSE HANDBOOK PROCEDURE. PULLED CIRCUIT BREAKER Q7 AND LEFT OUT FOR REMAINDER OF FLIGHT. REPLACED THE NR 2 FLIGHT WARNING COMPUTER IAW SDR AALA201808249004Floor Panel · delaminatedAFT CARGO FLOOR PANEL 151VG FORWARD OF DOORWAY WAS DELAMINATED. THE AIRCRAFT WAS GROUNDED. REPLACED THE FLOOR PANEL IAW 53-42-14.SDR AALA201804049028Interface Unit · faultyGEAR DISAGREED, ON GO AROUND, GEAR LOCKED INTO PLACE. GEAR LEFT DOWN AND CIRCLED AROUND TO LAND. NO EMERGENCY DECLARED. AIRCRAFT WAS GROUNDED. MAINTENANCE ACCOMPLISHED TSM 32-31-00-810-808, AND 32-31-00-810-836. NO FAULTS FOUND. ACCOMPLISHED EIGHT SUCCESSFUL SDR AALA201804039019Battery · inoperativeL1 DOOR FLASHLIGHT LED DOES NOT FLASH. REPLACED THE BATTERY. OPERATIONS NORMAL, OK FOR SERVICE IAW AMM 25-60-00SDR AALA201801319026Wire · exposedFOUND CEILING EMERGENCY LIGHT ASSEMBLY CONNECTOR BACKSHELL DAMAGED AND WIRES EXPOSED. REPLACED THE CONNECTOR AND REPAIRED THE WIRES IAW ESPM 20-53-21-02-01, AND AMM 33-51-02. PERFORMED EMERGENCY LIGHT TEST IAW AMM 33-51-00-710-001-A.SDR AALA201801319023Connector · damagedFOUND CEILING EMERGENCY LIGHT ASSEMBLY CONNECTOR BACKSHELL DAMAGED AND WIRES EXPOSED. REPLACED THE CONNECTOR BACKSHELL AND REPAIRED THE WIRES IAW ESPM 20-53-21-02-01, AND AMM 33-51-02. PERFORMED EMERGENCY LIGHT TEST IAW AMM 33-51-00-710-001-A.SDR AALA201709089003Warning Message · false activationAFTER LOWERING LANDING GEAR HANDLE, RECIVED AN ECAM FOR THE LANDING GEAR NOT DOWN AND LOCKED. CYCLED THE GEAR HANDLE, ALL GEAR THEN WENT DOWN AND LOCKED. ACCOMPLISHED GEAR RETRACTION & EXTENSION FOR FIVE CYCLES, LGCIU BIT CHECKED GOOD. UNABLE TO DUPLICATE. NOSDR AALA201707179033Fitting · crackedWHILE INSPECTING THE MAIN LANDING GEAR DOOR KEEL BEAM HINGE FITTING AND ACTUATOR FITTING, FOUND CRACKS ON THE LEFT DOOR ACTUATOR FITTINGS AT KEEL BEAM RIB W10, BETWEEN STRINGERS 41R AND 42R. REPLACED THE ACTUATOR FITTINGS IAW EA #271534.SDR AALA201707179032Plate · corrodedWHILE INSPECTING THE MAIN LANDING GEAR DOOR KEEL BEAM HINGE FITTING AND ACTUATOR FITTING, FOUND CORROSION ON THE LEFT DOOR UPPER PLATE AT KEEL BEAM RIB W10, BETWEEN STRINGERS 41R AND 42R. REPAIRED UPPER PLATE IAW EA 271534.SDR AALA201707179031Strap · crackedWHILE INSPECTING THE MAIN LANDING GEAR DOOR KEEL BEAM HINGE FITTING AND ACTUATOR FITTING, DETECTED A CRACK ON THE RIGHT DOOR AFT ACTUATOR FITTING AT KEEL BEAM RIB W10, BETWEEN STRINGERS 41R AND 42R. REPAIRED THE UPPER STRAP IAW EA 271535.SDR AALA201707179030Fitting · crackedWHILE INSPECTING THE MAIN LANDING GEAR DOOR KEEL BEAM HINGE FITTING AND ACTUATOR FITTING, DETECTED CRACK ON THE RIGHT DOOR AFT ACTUATOR FITTING AT KEEL BEAM RIB W10, BETWEEN STRINGERS 41R AND 42R. REPAIRED THE FITTING IAW EA 271535.SDR AALA201707179029Fitting · crackedWHILE INSPECTING THE MAIN LANDING GEAR DOOR KEEL BEAM HINGE FITTING AND ACTUATOR FITTING, DETECTED A CRACK ON THE RIGHT DOOR AFT ACTUATOR FITTING AT KEEL BEAM RIB W10, BETWEEN STRINGERS 41R AND 42R. REPAIRED AFT ACTUATOR FITTING IAW EA 271535.SDR AALA201705239007Relay · malfunctionedDURING APPROACH, SELECTED GEAR DOWN. GEAR FAILED TO EXTEND. RECYCLED GEAR UP THEN CYCLED GEAR DOWN, GEAR EXTENDED NORMALLY. TEST OF EXTENSION & RETRACTION IAW AMM 32-31-00-720-002-A WITH NO FAULTS FOUND. REPLACED RELAY 62GA IAW ESPM 20-46-50. AIRCRAFT WAS GSDR AALA201705229007Landing Gear · malfunctionedDURING APPROACH, SELECTED GEAR DOWN. GEAR FAILED TO EXTEND. RECYCLED GEAR UP THEN RECYCLED GEAR DOWN, GEAR EXTENDED NORMALLY. TEST OF EXTENSION & RETRACTION IAW AMM 32-31-00-720-002-A WITH NO FAULTS FOUND. REPLACED RELAY 62GA AS PRECAUTION IAW ESPM 20-46-50.SDR AALA201704289006Light · inoperativeAFT RIGHT DOOR LIGHT INOPERATIVE. REPLACED EXIT LIGHT LENS.SDR AALA201704189016Control Valve · faultyTAKEOFF REJECT GREATER THAN 40KTS, RECEIVED ECAM MESSAGE FOR CONFIGURATION PARK BRAKE ON. REMOVED AND REPLACED PARKING BRAKE CONTROL VALVE.SDR AALA201702159005Lens · brokenR2 DOOR EMERGENCY LIGHT LENS BROKEN. REPLACED EMERGENCY LIGHT LENS.SDR AALA201609079018Cylinder · leakingAIRCRAFT WAS GROUNDED: FLIGHT CREW REPORTED A GREEN HYDRAULIC RESERVOIR LOW LEVEL FAULT MESSAGE, AN EMERGENCY WAS DECLARED. THE AIRCRAFT LANDED SAFELY AND WAS TOWED TO THE GATE. MAINTENANCE FOUND THE NOSE WHEEL STEERING CYLINDER LEAKING AND REPLACED IT IAW ASDR AALA201511309014Seat Back · out of adjustSEAT 8C AT EMER EXIT RECLINES TO FAR. ADJUSTED SEAT 8C RECLINE & ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK IAW AMM 25-21-00.SDR AALA201511029015Brake · smokeTOWER REPORTED SMOKE EMANATING FROM MAIN GEAR EXITING RUNWAY. ACCOMPLISHED INSPECTION OF MAIN GEAR & BRAKE WITH NO LEAKS BEING NOTED & ALL TEMPERATURES WERE NORMAL IAW AMM 05-27-00.SDR AALA201506299014Power Supply · inoperative3S CHECK, OVERWING ESCAPE ROUTE LIGHTING IS INOPERATIVE. REPLACED POWER SUPPLY UNIT 11WL IAW AMM 33-51-38-400-001-A. ACCOMPLISHED AN OPERATIONAL CHECK WITH NO DEFECTS NOTED.SDR AALA201506299013Connector · defectiveEMERGENCY EXIT LIGHTS INOPERATIVE AT THE L1, R1 DOORS, FIRST CLASS CEILING & SECTIONS 1CA 4C. REPLACED EMER POWER SUPPLY CONNECTOR 10ML IAW ESPM 20-44-11. ACCOMPLISHED AN OPERATIONAL CHECK WITH NO DEFECTS NOTED.SDR AALA201506309011Power Supply · inoperative3S CHECK, CEILING POWER SUPPLY UNITS 10WL, 11WL & 12WL FAILED TEST. REPLACED POWER SUPPLY UNITS. ACCOMPLISHED AN OPERATIONAL CHECK IAW AMM 33-51-38-400-002-A & 33-51-00-710-009-A, WITH NO DEFECT NOTED. PLEASE SEE AALA201506299012 & AALA201506309010 FOR ADDISDR AALA201506309010Power Supply · inoperative3S CHECK, CEILING POWER SUPPLY UNITS 10WL, 11WL & 12WL FAILED TEST. REPLACED POWER SUPPLY UNITS. ACCOMPLISHED AN OPERATIONAL CHECK IAW AMM 33-51-38-400-002-A & 33-51-00-710-009-A, WITH NO DEFECT NOTED. PLEASE SEE AALA201506299012 & AALA201506309011 FOR ADDISDR AALA201506299012Power Supply · inoperative3S CHECK, CEILING POWER SUPPLY UNITS 10WL, 11WL & 12WL FAILED TEST. REPLACED POWER SUPPLY UNITS. ACCOMPLISHED AN OPERATIONAL CHECK IAW AMM 33-51-38-400-002-A & 33-51-00-710-009-A, WITH NO DEFECT NOTED. PLEASE SEE AALA201506309010 & AALA201506309011 FOR ADDISDR AALA201507019006Floor Panel · delaminated3S CHECK, AFT GALLEY FLOOR PANEL 262BG HAS DELAMINATION. REPLACED FLOOR PANEL 262BG IAW SRM 53-00-00 PAR 8H FIG 209 & IRM 9701 REV G.SDR AALA201506309004Fitting · broken3S CHECK, RT WING NR 3 SLAT, NR 7 TRACK ANTI-ROTATION FITTING BROKEN. REPAIRED IAW SRM 57-40-00 PARAGRAPH 5.A.A FIGURE 237.SDR AALA201506309003Fitting · worn3S CHECK, RT WING NR 2 SLAT, NR 5 TRACK ANTI-ROTATION FITTING WORN. REPAIRED IAW SRM 57-40-00 PARAGRAPH 5.Z STEP 3.SDR AALA201506309002Stop Fitting · worn3S CHECK, RT WING NR 3 SPOILER CTR HINGE FITTING BOLT STOP WORN. REPAIRED IAW SRM 57-70-00 PARAGRAPH 4C FIG 201.SDR AALA201506309001Stop Fitting · worn3S CHECK, RT WING NR 2 SPOILER CTR HINGE FITTING BOLT STOP WORN. REPAIRED IAW SRM 57-70-00 PARAGRAPH 4C FIG 201.SDR AALA201506179010Bolt · corroded3S CHECK, CORROSION ON RT WING TE FLAP NR 3 TRACK PIVOT BOLT. REPLACED RT WING TE FLAP NR 3 TRACK PIVOT BOLT IAW 26T63257002.SDR AALA201506309005Fitting · worn3S CHECK, RT WING NR 1 SLAT, NR 4 TRACK ANTI-ROTATION FITTING BROKEN. REPAIRED IAW SRM 57-40-00 PARAGRAPH 5 Y 3 1 REPAIR PROCEDURE B.SDR AALA201506299004Attach Fitting · corroded3S CHECK, CORROSION ON LT MLG RETRACTION ACTUATOR ATTACH FITTING AT STATION 3069 BETWEEN RIB 2 & 3. REPAIRED IAW EA 251897.SDR AALA201506299008Window Frame · cracked3S CHECK, LT WINDSHIELD POST LOWER ATTACH POINT CRACKED AT FRAME 4L. REPAIRED IAW EA 251967.SDR AALA201506299002Skin Panel · corroded3S CHECK, CORROSION ON EXTERNAL SKIN BETWEEN FRAME 66 & 68 AT STRINGER 23R UNDER THE R2 DOOR SCUFF PLATE. REPAIRED SKIN IAW EA 251902 & SRM 53-41-11 PARA 4D FIG 105.SDR AALA201506129014Fitting · corrodedS3 & SY6 CHECK. CORROSION ON FITTING BETWEEN FRAME 16 TO 20 AT STRINGER 23L. REPLACED FITTING BETWEEN FRAME 16 TO 20 AT STRINGER 23L IAW SRM 51-72-11 & DWG D53112225.SDR AALA201506309006Hinge Fitting · worn3S CHECK, RT ELEVATOR NR 1 HINGE OTBD LUG BUSHING MIGRATED, FITTING BORE WORN. REPAIRED IAW SRM 55-26-41.SDR AALA201506299003Hinge Fitting · corroded3S CHECK, CORROSION ON ELEVATOR HINGE FITTING, NR 4 OTBD LUG BORE AT ELEVATOR STATION 1305 - 809 & RIB 4 - 5. REPAIRED HINGE FITTING IAW SRM 55-26-41.SDR AALA201506179008Hinge Fitting · excess play3S CHECK, RT ELEVATOR NR 3 HINGE FITTING HAS EXCESSIVE PLAY. REPLACED THE RT ELEVATOR NR 3 HINGE FITTING IAW AMM 55-16-42-400-001-A.SDR AALA201506179007Hinge Fitting · excess play3S CHECK, RT ELEVATOR NR 5 HINGE FITTING HAS EXCESSIVE PLAY. REPLACED THE RT ELEVATOR NR 5 HINGE FITTING IAW AMM 55-16-42-400-001-A.SDR AALA201506179006Hinge Fitting · excess play3S CHECK, RT ELEVATOR NR 6 HINGE FITTING HAS EXCESSIVE PLAY. REPLACED THE RT ELEVATOR NR 6 HINGE FITTING IAW AMM 55-16-42-400-001-A.SDR AALA201506179005Hinge Fitting · excess play3S CHECK, RT ELEVATOR NR 2 HINGE FITTING HAS EXCESSIVE PLAY. REPLACED THE RT ELEVATOR NR 2 HINGE FITTING IAW AMM 55-16-42-400-001-A.