N723FD
Service difficulty reports · 143
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N723FD' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N723FD' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR FDEA202202170316Smoke Detector · failedMDIS 723 26-12 0793 17FEB22 MKE FACT U AFTER SHUTTING DOWN ENG #1 GOT DC ESS ON BAT. WITHIN APPROX 2 MINUTES, AVIONICS SMOKE CAME ON WITH NO INDICATION OF SMOKE. PER CREW DEBRIEF. FACT 17FEB22 14:48 MKE U R&R AVIONICS SMOKE DETECTOR FLT COSDR FDEA202201180081None · nonePDIS 723 26-12 0737 18JAN22 IND OPEN U ON APPROACH DESCENDING THROUGH 1500 FEET ECAM AVIONICS SMOKE ACTIVATED. UPON LANDING STARTED TO SMELL FUMES EXITED RUNWAY AND SHUT DOWN FUMES DISSIPATED. EMERGENCY WAS DECLARED. SHGN 18JAN22 11:59 SDR FDEA202201050013None · unknown**SDR ENTERED IN ERROR** **SDR ENTERED IN ERROR**SDR FDEA202201050012Smoke Detector · faultedRECEIVED AVIONICS SMOKE MESSAGE AT FL320. COMPLIED WITH ECAM AND QRH. NO SMOKE WAS NOTED BUT DECLARED EMERGENCY AND LANDED ON RWY 27 AT KMEM. NO SMOKE OR FIRE WAS DETECTED BY THE GROUND FIRE CREW. TROUBLESHOT PER A300 TSM 26-15-00 AND SUSPECT COCKPIT DET-SDR FDEA202107101720O-Ring · leakingON DESCENT INTO MEM RECEIVED ECAM YELLOW SYS PUMP LO PRESS. DETERMINED YELLOW SYS LOW QUANTITY. COMPLIED WITH ECAM/QRH. UPON INVESTIGATION OF HYDRAULIC LEAK, FOUND YELLOW SYS ISOLATION VALVE BLOCK LEAKING. FOUND O-RINGS FROM VALVE BLOCK PLUGS TORN. REPLASDR FDEA202010212592Smoke Detector · false activationAVIONICS SMOKE LIGHT CAME ON DURING APPROACH TO KABE. DECLARED AN EMERGENCY. LANDED WITH NO VISIBLE SMOKE APPARENT. INSPECTED AVIONICS BAY AND NO SMOKE OR FUMES NOTED. DID NOTE HIGH HUMIDITY LEVELS IN THE LOWER CARGO/AVIONICS BAY AREAS. DEPARTURE STATIONSDR FDEA2020081871911Skin · delaminatedRH WING 3# SPOILER WITH DELAMINATED RH WING 3# SPOILER WITH DELAMINATED, COMPLIED WITH FEDEX EA:6-5750-T0355587 P1, MAJOR REPAIR IAW GMM 6-2-100,SDR FDEA202008171910Skin · delaminatedLH WING 3# SPOILER WITH DELAMINATED LH WING 3# SPOILER WITH DELAMINATED, COMPLIED WITH EA:6-5750-T0355485 P1.SDR FDEA2020081871914Skin · delaminatedRH WING NR 5 SPOILER WITH DELAMINATION. COMPLIED WITH EA:6-5750-T0355513 P1. MAJOR REPAIR IAW GMM6-2-100, THIS IS A CAT A REPAIR.SDR FDEA2020081871913Skin · delaminatedRH WING NR 4 SPOILER WITH DELAMINATION. COMPLIED WITH EA:6-5750-T0355586 P1. MAJOR REPAIR IAW GMM6-2-100, THIS IS A CAT A REPAIR.SDR FDEA2020081871912Skin · delaminatedLH WING 5# SPOILER WITH DELAMINATION COMPLIED WITH FEDEX EA:6-5750-T0355486 P1, MAJOR REPAIR IAW FEDEX GMM6-2-100, THIS IS A CAT A REPAIR.SDR FDEA202008131877Beam · crackedNDT INSPECTION, CRACK WAS FOUND AT THE RH FLANGE OF GANTRY 4.RH FR52.A. REPAIRED THE CRACK OF THE GANTRY RH #4 AT FR52A PER AIRBUS DWG: R53810581 ISSUE: C. DETAIL REPAIR STEPS: DRILLED CRACK STOP HOLES DIA 4 TO 4.012MM AT EACH END OF CRACK AND INSTALLED THSDR FDEA2020082131876Skin · crackedLOWER FUSELAGE SKIN LAP FR54 STGR44RH MARKED FASTENER FOUND A SUSPECT CRACK (1EA) REPAIRED THE CRACKED FUSELAGE SKIN AT FR54 STGR44RH PER EA# 6-5330-T0355811 P1. EA TITLE: FUSELAGE - PLATES & SKINS - FASTENER LOCATION CRACK INDICATION REPAIR - BETWEEN FRSDR FDEA2020082031875Floor Support · corrodedMAIN DECK CARGO, FRAMES 12A - 14, Y1456, FLOOR SUPPORT CORRODED AROUND BOLT HOLES. EXCEEDED THE ALLOWABLE THICKNESS IAW SRM 53-12-15-001. CUT OUT THE CORRODED AREA AND MANUFACTURED REPAIR PARTS IAW SRM 53-12-15, FIG.207. INSTALLED THE REPAIR IAW SRM 53-12SDR FDEA2020081431877Flange · crackedNDT INSPECTION, CRACK WAS FOUND AT THE RH FLANGE OF GANTRY 4.RH FR52.A.SDR FDEA2020081431876Skin · crackedLOWER FUSELAGE SKIN LAP FR54 STGR44RH MARKED FASTENER FOUND A SUSPECT CRACK (1EA)SDR FDEA2020081431875Floor Support · corrodedMDCC - FR12A~FR14 Y1456, FLOOR SUPPORT CORRODED AROUND BOLT HOLESSDR FDEA202006101173Gusset · crackedF/O WINDSHIELD LOWER FRAME WORK CARD 5311010-41 FOUND HOLE 10 CRACK INDICATION IN GUSSET COMPLIED WITH E.A. 6-5310-T0354496 CRACK IN F/O WINDOW FRAME 4 GUSSET. INSTALLED NEW GUSSET IN REF TO A300 SRM 51-40-20.SDR FDEA2020061201173Gusset · crackedF/O WINDSHIELD LOWER FRAME WORK CARD 5311010-41 FOUND HOLE 10 CRACK INDICATION IN GUSSET.SDR FDEA201807241814Control Unit · inoperativeTHE RIGHT CABIN SLIDE DID NOT INDICATE ARMED AT BLOCK IN. ALSO FOUND THAT BOTH MAIN ENTRY DOORS SLIDE TEST BUTTONS WOULD NOT ENGAGE RED BLINKING LIGHT BARS. R&R AUTONOMOUS STANBY UNIT PER AMM 52-73-18-04. OPS CHECKS GOOD AND SLIDE ARM WORK PLUS DOOR ALARM SDR FDEA201804030835Wire Harness · damagedAFTER LANDING, NO NOSE WHEEL STEERING. FO PITOT & TAT, ENG 2 ON OVERHEAD ILLUMINATED. SPOILER 4 & 1 AND 3 & 2 ON OVERHEAD ILLUMINATED. LEFT ECAM SHOWED SPOILER 4 & 1, 3 & 2, YAW DAMPER 1 OFF, PITCH TRIM 1 OFF, FO PITOT OVERHEAT, CABIN PRESS REG 1 FAULT. SDR FDEA201802230495Brake · destroyedWHILE REMOVING THE NR 1 TIRE, FOUND THE NR 1 BRAKE ASSY DISINTEGRATING. REMOVED AND REPLACED THE BRAKE ASSY IAW 32-42-27-04.SDR FDEA201802070317Seat Track · brokenSEAT TRACK SCALLOPS BROKEN IN MAIN DECK CARGO BETWEEN FR 57 AND FR 57.1 Y953. REMOVED AND REPLACED DAMAGED SEAT TRACK SECTION AT Y953 FR 56 TO FR 57.2 IAW SRM 53-10-16 PARA 10, FIG 208. MAJOR REPAIR.SDR FDEA201801240222Floor Panel · damagedCOURIER FLOOR PANEL 221PF DAMAGED AT PREVIOUS REPAIR AREA. FABRICATED COURIER FLOOR PANEL 221PF ON T17/1316881 IAW DWG SRZ-25-005 CAT "A" MAJOR REPAIR.SDR FDEA201801230183Seat Track · damagedSEAT TRACK SCALOPS GOUGED / BROKEN IN MAIN DECK COMPT AT FR59 -Y1930. REMOVED DAMAGE SEAT TRACK SECTION AND FABRICATED NEW REPAIR SEAT TRACK AT IAW SRM 53-10-16. INSTALLED NEW REPAIR SECTION FROM FRAME 58-60 RT -Y1930 IAW SRM 51-40-21, MAJOR REPAIR.SDR FDEA201801230182Floor Panel · puncturedMAIN DECK FLOOR PANEL 231DH HAS PUNCTURES. FABRICATED A NEW FLOOR PANEL IAW SRZ-25-005. MAJOR REPAIR.SDR FDEA201801230181Floor Panel · crackedMAIN DECK FLOOR PANEL 231HG CRACKED. FABRICATED A NEW FLOOR PANEL IAW SRZ-25-005. MAJOR REPAIR.SDR FDEA201801220167Floor Panel · brokenMAIN DECK FLOOR PANEL 241XJ BROKEN. FABRICATED A NEW FLOOR PANEL IAW SRZ 25-005. MAJOR REPAIR.SDR FDEA201801220166Floor Panel · damagedMAIN DECK FLOOR PANEL 242HK BROKEN. FABRICATED A NEW FLOOR PANEL IAW SRZ 25-005. MAJOR REPAIR.SDR FDEA201801220165Floor Panel · brokenMAIN DECK FLOOR PANEL 242CF BROKEN. FABRICATED A NEW FLOOR PANEL IAW SRZ 25-005. MAJOR REPAIR.SDR FDEA201801220164Floor Panel · crackedMAIN DECK FLOOR PANEL 231QG CRACKED. FABRICATED A NEW FLOOR PANEL IAW SRZ 25-005. MAJOR REPAIR.SDR FDEA201801220163Floor Panel · puncturedMAIN DECK FLOOR PANEL 231FF HAS MULTIPLE PUNCTURES. FABRICATED FLOOR PANEL IAW SRZ 25-005. MAJOR REPAIR.SDR FDEA201801220162Floor Panel · damagedMAIN DECK FLOOR PANEL 231BH HAS EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SRZ 25-005. MAJOR REPAIR.SDR FDEA201801220161Floor Panel · crackedMAIN DECK FLOOR PANEL 231VG WAS CRACKED. FABRICATED A NEW FLOOR PANEL IAW SRZ 25-005. MAJOR REPAIRSDR FDEA201801220150Floor Panel · brokenMC FLOOR PANEL 242AJ BROKEN. FABRICATED A NEW FLOOR PANEL IAW SRZ 25-005. MAJOR REPAIR.SDR FDEA201801220149Floor Panel · brokenMC FLOOR PANEL 242TH BROKEN. FABRICATED A NEW FLOOR PANEL IAW SRZ 25-005. MAJOR REPAIR.SDR FDEA201801220148Floor Panel · brokenMC FLOOR PANEL 242SH BROKEN. FABRICATED A NEW FLOOR PANEL IAW SRZ 25-005. MAJOR REPAIR.SDR FDEA201801220147Floor Panel · tornMD FLOOR PANEL 231JG TORN ON UPPER SURFACE. FABRICATED A NEW FLOOR PANEL IAW SRZ 25-005. MAJOR REPAIR.SDR FDEA201801220145Floor Panel · brokenMD FLOOR PANEL 241FK BROKEN. FABRICATED A NEW FLOOR PANEL IAW SRZ 25-005. MAJOR REPAIR.SDR FDEA201801220144Floor Panel · brokenMD FLOOR PANEL 241GJ BROKEN. FABRICATED A NEW FLOOR PANEL IAW SRZ 25-005. MAJOR REPAIR.SDR FDEA201801220143Floor Panel · brokenMD FLOOR PANEL 241KJ BROKEN. FABRICATED A NEW FLOOR PANEL IAW SRZ 25-005. MAJOR REPAIR.SDR FDEA201801220142Floor Panel · crackedMD FLOOR PANEL 241DF CRACKED. FABRICATED A NEW FLOOR PANEL IAW SRZ 25-005. MAJOR REPAIR.SDR FDEA201801220141Floor Panel · puncturedMD FLOOR PANEL 231WG HAS MULTIPLE PUNCTURES. FABRICATED A NEW FLOOR PANEL IAW SRZ 25-005. MAJOR REPAIR.SDR FDEA201801220140Floor Panel · puncturedMD FLOOR PANEL 231RH HAS MULTIPLE PUNCTURES. FABRICATED A FLOOR PANEL IAW SRZ 25-005. MAJOR REPAIR.SDR FDEA201801200129Floor Panel · damagedMD FLOOR PANEL 231KG HAS EDGE DAMAGE & BROKEN INSERTS. FABRICATED A NEW FLOOR PANEL IAW SRZ 25-005. MAJOR REPAIR.SDR FDEA201801200128Floor Panel · puncturedMD FLOOR PANEL 232KG PUNCTURED. FABRICATED A NEW FLOOR PANEL IAW SRZ 25-005. MAJOR REPAIR.SDR FDEA201801200127Floor Panel · puncturedMD FLOOR PANEL 232DF PUNCTURED. FABRICATED A NEW FLOOR PANEL IAW SRZ 25-005. MAJOR REPAIR.SDR FDEA201801200126Floor Panel · damagedMD FLOOR PANEL 231CF HAS EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SRZ 25-005. MAJOR REPAIRSDR FDEA201801200125Floor Panel · damagedMAIN DECK FLOOR PANEL 231LG HAS EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SRZ 25-005. MAJOR REPAIR.SDR FDEA201711083198Line · failedCLIMBING THROUGH 12000FT, THE NR 1 BLEED VALVE FAULT LIGHT ILLUMINATED. TURNED OFF & ON BLEED VALVE SWITCH MULTIPLE TIMES WITH NO RESET. FAULT LIGHT REMAINED AFTER MULTIPLE ATTEMPTS. FOLLOWED QRH WITH NO SUCCESS. . VERIFIED NR 2 PACK OFF. JUMPSEATER IN