What was found
MAIN DECK CARGO, FRAMES 12A - 14, Y1456, FLOOR SUPPORT CORRODED AROUND BOLT HOLES. EXCEEDED THE ALLOWABLE THICKNESS IAW SRM 53-12-15-001. CUT OUT THE CORRODED AREA AND MANUFACTURED REPAIR PARTS IAW SRM 53-12-15, FIG.207. INSTALLED THE REPAIR IAW SRM 53-12-15, FIG.207, & SRM 51-40-21. MAJOR REPAIR IAW GMM 6-2-100. THIS IS A CAT B REPAIR.