N732US
Service difficulty reports · 280
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N732US' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N732US' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR USAA2011072900017Floorbeam · corrodedC11 CHECK - LEVEL 2 INTERGRANULAR CORROSION ON FLOORBEAM AT FR66, -Y765. REPLACED FLOORBEAM AT FR66, -Y765 IAW A319 SRM 53-41-14.SDR USAA2011072900014Floorbeam · corrodedC11 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM AT FR66, -Y464.8. REPLACED FLOORBEAM AT FR66, -Y464.8 IAW A319 SRM 51-42-00.SDR USAA2011072900011Floorbeam · corrodedC11 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM AT FR66, Y1292. REPLACED FLOORBEAM AT FR66, Y1292 IAW A319 SRM 51-72-11 & EA 200483.SDR USAA2011072900010Shear Plate · corrodedC11 CHECK - LEVEL 2 EXFOLIATION CORROSION ON SHEAR PLATE BETWEEN FR68 TO FR70, -Y1162.5. REPLACED SHEAR PLATE BETWEEN FR68 TO FR70, -Y1162.5 IAW A319 SRM 51-72-11 & TYPICAL REPAIR 320-2528-10-0011.SDR USAA2011072900009Shear Plate · crackedC11 CHECK - CRACK IN SHEAR PLATE AT FR68 + 8 INCHES, -Y1162. REPLACED SHEAR PLATE AT FR68 + 8 INCHES, -Y1162 IAW A319 SRM 51-42-11.SDR USAA2011072900008Floorbeam · corrodedC11 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM BETWEEN FR20 TO FR21, -Y1292. REPLACED FLOORBEAM BETWEEN FR20 TO FR21, -Y1292 IAW A319 SRM 51-42-11.SDR USAA2011072900006Support · corrodedC11 CHECK - LEVEL 2 EXFOLIATION CORROSION ON SHEAR TIE SUPPORT BETWEEN FR69 TO FR70, -Y1160. REPLACED SHEAR TIE SUPPORT BETWEEN FR69 TO FR70, -Y1160 IAW A319 SRM 51-42-11 & SRM 51-72-11.SDR USAA2011072900004Floorbeam · corrodedC11 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM BETWEEN FR66 TO FR70, Y765. REPLACED FLOORBEAM BETWEEN FR66 TO FR70, Y765 IAW A319 SRM 51-72-11.SDR USAA2011080100034Floorbeam · corrodedC11 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM AT FR16, -Y1292. REPLACED FLOORBEAM AT FR16, -Y1292 IAW A319 SRM 51-42-11.SDR USAA2011080100032Floorbeam · corrodedC11 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM AT FR16, Y503.2. REPLACED FLOORBEAM AT FR16, Y503.2 IAW A319 SRM 53-11-14.SDR USAA2011072900012Floorbeam · corrodedC11 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM AT FR20, -Y254. REPLACED FLOORBEAM AT FR20, -Y254 IAW A319 SRM 51-42-00.SDR USAA2011072900002Floorbeam · corrodedC11 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM BETWEEN FR16 TO FR23, Y254. REPLACED FLOORBEAM BETWEEN FR16 TO FR23, Y254 IAW A319 SRM 51-42-00.SDR USAA2011010590056Battery · dischargedFLT 1967 - ABE-CLT - EMERGENCY LIGHTS - 2 BATTERIES REQUIRED FOR FORWARD HANDHELD FLASHLIGHT. REMOVED AND REPLACED BATTERIES ON FORWARD HANDHELD FLASHLIGHT.SDR USAA2009122893434Connector · looseFLT 1620 - MBJ-PHX - EMERGENCY LIGHTS - EMERGENCY LIGHT 12L INOPERATIVE. FOUND LOOSE CONNECTOR AT 12L SEAT, RECONNECTED. OPERATIONAL CHECK WAS GOOD.SDR USAA2009120393293Connector · faultyFLT 2048 - DCA - BOS - EMERGENCY LIGHTS - RIGHT EMERGENCY EXIT LIGHT FORWARD OF OVERWING EXIT INOPERATIVE. REMOVED AND REPLACED ELECTRICAL CONNECTOR PER ESM 20-44-19. OPERATIONAL CHECK WAS GOOD.SDR USAA2009062591591Battery · dischargedFLT 1907 - BUF-PHL - EMERGENCY LIGHTS - FLASHLIGHT AFT RIGHT INOPERATIVE. REMOVED AND REPLACED FLASHLIGHT BATTERY. OPERATIONAL CHECK WAS GOOD.SDR USAA2009060491393Lens · missingFLT 1907 - PHL - DFW - EMERGENCY LIGHTS - EMERGENCY LIGHT LENS MISSING AT SEAT 4C. INSTALLED MISSING LIGHT LENS. OPERATIONAL CHECK WAS GOOD.SDR SA05103Odor · detectedCLT FLT 1109 EN-ROUTE LGA TO CLT - A HOT ODOR WAS NOTED IN CABIN IN BOTH TAKEOFF AND DESCENT. THE ODOR WAS NOTED TO BE PARTICULARLY PRESENT DESCENT AT IDLE. FLIGHT COMPLETED WITHOUT FURTHER INCIDENT. MAINTENANCE RAN BOTH ENGINES AND BLEED SYSTEMS. NO ODOSDR USAA051111Floor Support · corrodedFOUND CORROSION FLOOR SUPPORT Y-1162, DEFECTIVE PART REPLACED WITH IDENT PART NUMBER, DEFECT SIZE: 6 SQ IN IN SEVERAL SPOTS.SDR USAA051118Floorbeam · corrodedFOUND CORROSION LT BS 66 TO 68 INB OF DOOR SILL -Y1162. REPLACED WITH IDENTICAL PART PER SRM 51-42-00, DEFECT SIZE: 1" X 2".SDR USAA051114Beam · corrodedFOUND CORROSION RT BEAM STA 66-68 INB OF RT DOOR SEAL AT ATTACH HOLES. REPLACED WITH IDENTICAL PART NUMBER PER SRM 51-42-0, DEFECT SIZE: 1" X 2".SDR USAA051115Floorbeam · corrodedFOUND CORROSION LT STA 66 AFT END OF FLOORBEAM AT ATTACH HOLES FOR FLOORBOARD. REPLACED WITH IDENTICAL PART PER SRM 51-42-00, DEFECT SIZE: 1" X 2".SDR USAA051117Floorbeam · corrodedFOUND CORROSION RT BEAM Y-1292 STA 66 AT ATTACH HOLE AFT END. REPLACED WITH IDENTICAL PART PER SRM 51-42-00, DEFECT SIZE: 1" X 2".SDR USAA051119Floorbeam · corrodedFOUND Y-765 FLOORBEAM CORROSION (RT) 7" AFT OF STA 66 AROUND ATTACH HOLES. REMOVED AND REPLACED BEAM WITH IDENTICAL PART NUMBER PER SRM 51-72-11, DEFECT SIZE: 1 X 1".SDR USAA051124Beam · corrodedFOUND CORROSION FR 16 AND BETWEEN FR 19 AND 20 CENTER BEAM. INSTALLED DOUBLERS PER SRM 53-00-14 FIG 206, DEFECT SIZE: 2" X 2" AND 1" X 1".SDR USAA051125Floorbeam · corrodedFOUND CORROSION BETWEEN FR 13 AND 15. REPLACED BEAM PER SRM 51-72-11, DEFECT SIZE: 1" X 2".SDR USAA051116Floorbeam · corrodedFOUND CORROSION LT BEAM Y1162 STA 68 AROUND NUT PLATES AT ATTACH HOLES. REPLACED WITH IDENTICAL PART PER SRM 51-42-00, DEFECT SIZE: 1" BY 2".SDR USAA051090Shear Tie · corrodedRT SIDE SHEAR TIE CORRODED BETWEEN FRAMES 69 AND 70. DEFECTIVE PART REPLACED WITH IDENT PART NR, DEFECT SIZE: 2 SQ IN.SDR SA04093Epsu · faultyTHE AFT LT EMERGENCY POWER SUPPLY UNIT FAULTED DURING TEST. MAINTENANCE REPLACED THE AFT LT EMERGENCY POWER SUPPLY UNIT. OPERATIONALLY CHECKS OK.SDR USAASA03105Release Cable · incorrectCLT - THE AFT ENTRY DOOR EMERGENCY ESCAPE SLIDE WAS FOUND TO HAVE AN INCORRECT RELEASE CABLE INSTALLED DURING INSPECTION. MAINTENANCE REPLACED THE SLIDE ASSEMBLY. OK FOR SERVICE. THE REPAIR SHOP INSTALLED THE PROPER RELEASE CABLE ON THE SLIDE AND RETURNED T
Back to N732US