N744CK
Service difficulty reports · 81
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N744CK' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N744CK' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR KCSA2026042123Battery Pack · discharged100320914: RIGHT SIDE UPPER DECK DOOR EMERGENCY OPENING SYS BATTERY PACK DEAD A/T: ITEM TRANSFERRED TO DMI #100320914 CAT C DUE 5/1/26 M PROCEDURE COMPLIED WITH IAW B747 MEL 52-23-1-3A PLACARDS INSTALLED. REF DMI #100320914 RH UPPER DECK DOOR BATT PACK INOP. SDR KCSA202604041028Battery Pack · no testRIGHT UPPER DECK ESCAPE DOOR BATTERY PACK FAIL PUSH TO TEST LIGHT DURING A/C START UPSDR KCSA202503291046Spar · crackedDURING ULTRASOUND INSPECTION, CRACK INDICATION NOTED AT LOWER FASTENER HOLE ON RIGHT WING LEADING EDGE UPPER CHORD AT ILES STA 664.SDR KCSA202503261044Battery Pack · inoperativeRH UPPER DECK DOOR EMERGENCY OPENING BATTERY DOES NOT TESTSDR KCSA202503261043Battery Pack · no testLH UPPER DECK DOOR EMERGENCY OPENING BATTERY DOES NOT TESTSDR KCSA202503191042Stiffener · crackedVERTICAL STIFFENER IS CRACKED (1/2") ON THE AFT SIDE OF THE MAIN DECK FLOORBEAM AT STATION 2360 AT RBL 32SDR KCSA202503191041Stiffener · crackedVERTICAL STIFENNER IS CRACKED ( 1") ON THE AFT SIDE OF THE MAIN DECK FLOORBEAM AT STATION 2360 AT RBL 16SDR KCSA202503191040Stiffener · crackedVERTICAL STIFFENER IS CRACKED ( 1") ON THE AFT SIDE OF THE MAIN DECK FLOORBEAM AT STATION 2360 AT LBL 16SDR KCSA202503191039Strap · crackedCRACK INDICATION AT FASTENER HOLE IN STA 2231 FRAME STRAP AT LWR AFT HOLE COMMON TO STRINGER S-25R DOOR STOP SUPPORT STRAP FOUND DURING OPEN HOLE HFEC INSP.SDR KCSA202503181038Stiffener · crackedVERTICAL STIFFENER IS CRACKED ( 1") ON THE AFT SIDE OF THE MAIN DECK FLOORBEAM AT STATION 2360 AT LBL 32SDR KCSA202503151037Skin · damagedFOUND EVIDENCE OF LIGHTNING DAMAGE AT BL 2020, WL 118SDR KCSA202503151036Skin · damagedPOSSIBLE EVIDENCE OF LIGHTNING STRIKE ON FUSELAGE SKIN STA 460 IN BETWEEN LS-5 & LS-6SDR KCSA202503151035Skin · damagedEVIDENCE OF LIGHTNING STRIKE ON FUSELAGE FASTENER STA 720 IN BETWEEN LS-17 & LS-18SDR KCSA202503151034Skin · damagedEVIDENCE OF LIGHTNING STRIKE ON FUSELAGE SKIN STA. 1080 IN BETWEEN LS-16 & LS-17SDR KCSA202503151033Skin · damagedEVIDENCE OF LIGHTNING STRIKE ON FUSELAGE SKIN STA 1100 IN BETWEEN LS-16 & LS-17SDR KCSA202503151032Skin · damagedEVIDENCE OF LIGHTNING STRIKE ON FUSELAGE SKIN APPROX. STA 738 LS-17SDR KCSA202503151031Skin · damagedEVIDENCE OF LIGHTNING STRIKE ON FUSELAGE SKIN STA. 640 IN BETWEEN LS-7 & LS-8SDR KCSA202503151030Skin · damagedLIGHTNING STRIKE FOUND AT APPROX. 540 WL 130 LH SIDE OF FUSELAGESDR KCSA202503151029Skin · damagedLIGHTNING STRIKE FOUND AT APPROX 587 WL 130 LH SIDE OF FUSELAGESDR KCSA202503151028Skin · damagedLIGHTNING STRIKE FOUND AT APPROX. STA 550 WL 130 LH SIDE OF FUSELAGESDR KCSA202503151027Skin · damagedFOUND EVIDENCE OF LIGHTNING STRIKE AT STATION 2100, WATER LINE 122SDR KCSA202503151026Skin · damagedFOUND EVIDENCE OF LIGHTNING STRIKE AT STATION 2080, WL 118SDR KCSA202503151025Skin · damagedFOUND EVIDENCE OF LIGHTNING DAMAGE AT STATION 2060, WL 118SDR KCSA202503141024Skin · damagedEVIDENCE OF LIGHTNING DAMAGE AT STATION 2030, WL118SDR KCSA202503141023Skin · damagedFOUND EVIDENCE OF LIGHTNING STRIKE AT STA 466, WATER LINE 132SDR KCSA202503141022Skin · damagedFOUND EVIDENCE OF LIGHTNING STRIKE AT STA 430 WATER LINE 130SDR KCSA202503131021Crease Beam · crackedCREASE BEAM ATTACH ANGLE CRACKED AT STA 1240 BETWEEN STR 6R & 7RSDR KCSA202503131020Crease Beam · crackedCREASE BEAM ATTACH ANGLE CRACKED AT STA 1254 STR 5LSDR KCSA202503131019Stiffener · crackedFWD CARGO DOOR, AFT DOORSIDE LIFT LINK MOUNT STIFFNER CRACKEDSDR KCSA202312281153Escape Reel · partial deploy#5 POSITION EMERGENCY DESCENT DEVICE HAS EVIDENCE OF DEPLOYMENT P/N 379103D-23 S/N 25268SDR KCSA202312070550Unknown · unknownUPPER DECK EMERGENCY EQUIPMENT LIFE RAFT LANYARD ATTACH RING NOT INSTALLED TRANSFERRED TO DMI 100141630 PER MEL 25-62-1-1 CATEGORY D DUE 4-3-24 NO M PRODECURES PLACARDS INSTALLEDSDR KCSA202306130922Unknown · unknownUPPER DECK DOOR NO DISARMED MANUAL MODE PERFORMED OPERATIONS CHECK OF UPPER DECK LEFT DOOR IAW B747-400 AMM 52-73-02 ALL CHECKS GOODSDR KCSA2023051015Unknown · unknownELECTRICAL SMELL RIGHT SIDE OF FLIGHT DECK. REMOVED AND REPLACED TD318 IAW B747-400 SRM 51-40-02 AND BSWPM 20-30-00. RETERMINATED WIRES W256-122-04, W166-2-8, W166-42-8 IAW BSWPM 20-30-11 REMOVED AND REPLACED DAMAGED SECTIONS OF W166-42-8 AND W166-2-8 IAW BSSDR KCSA202302271007Floorbeam · corrodedEVIDENCE OF CORROSION ON UPPER DECK FLOOR BEAM UPPER CHORD STA 740 APROX RBL 5SDR KCSA202302271006Bracket · damagedL/H I/B AFT FLAP NO. 1 SPINDLE FWD BEARING RETAINING BRACKET BOLT HOLES DAMAGEDSDR KCSA2022121529Circuit Card · corrodedFIRE CARGO FORWARD REFERENCE WORK ORDER 100088021/100088022 FOR FORWARD FAILED AUTOMATIC FIRE/OVERHEAT LOGIC/TEST SYSTEM A31/A33, REPLACED AND OPERATIONS CHECK GOOD IAW AMM 26-10-01 PERFORMED SQUIB DISCHARGE TEST OF ALL LOWER LUBE FIRE BOTTLES IAW AMM 26-23-00SDR KCSA202110131117Light · inoperativeR/H UPPER DECK EMERGENCY ESCAPE DOOR FWD EMERGENCY LIGHT INOPSDR KCSA202102241010Stop Fitting · crackedR4 DOOR STOP PIN FITTING AFT EDGE 4TH FROM THE TOP CRACKED.SDR KCSA202102101009Skin · out of limitsVERTICAL STAB TO FUSELAGE INTERFACE BLENDID OUT OF LIMITS AT STA 2597 RHSDR KCSA202102101008Stiffener · crackedWEB STIFFENER IS CRACKED AT BOTTOM FASTENER HOLE STA 340 RBL 10SDR KCSA202102101007Skin · chafed#1 PYLON I/B SIDE AFT ACCESS PANEL OPENING HAS CHAFFING ON INSIDE SKIN LOWER SIDESDR KCSA202007301132Structure · corrodedCORROSON FOUND AT B STA 1480 BWL 91 LBL 80SDR KCSA202007301131Attach Fitting · crackedROLLER ATTACH FITTING AT WBL 443.83 IS CRACKED ON RH IB MID FLAPSDR KCSA202007301130Bulb · inoperativeONE EMERGENCY LIGHT BULB INOP IN LIGHT ASSEMBLY L5735 OVER L1 DOORSDR KCSA202005131062Skin · damagedSKIN DAMAGE ON LOWER EMPENNAGE AT STA 2632 RBL 7 JUST FWD OF APU BATTERY DOORSDR KCSA201905231133Light · inoperativeMULTIPLE EMERGENCY LIGHTS IN FWD UPPER DECK INOP.SDR KCSA201901291012Structure · crackedCRACK INDICATION NOTED ON LT FWD INNER CHORD TOP HOLE AS MARKED.SDR KCSA201901291011Seat Track · crackedPOSSIBLE CRACK ON CO-PILOTS O/B FWD SEAT TRACK AT FWD END.SDR KCSA201702211010Light · inoperativeUPPER DECK EMERGENCY LIGHTS BOTH L- AND R- AT DOOR CENTER AFT INOP. NO TEST OR ON.SDR KCSA201702211009Light · illuminatedUPPER DECK EMERGENCY LIGHTS AT UPPER DECK DOORS AND CENTER CEILING DROP DOWN STAY ON WITH POWER OFF AND SWITCH OFF.
Back to N744CK