N750NA
Service difficulty reports not matched to an aircraft · 104
They name N750NA, but no registry record covers the date, the aircraft registered then was built later, or the report describes another aircraft. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N750NA' AND registry_match IS NULL ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N750NA' AND registry_match IS NULL ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR NOCA201110210611Wire · looseACFT ABORTED TAKEOFF DUE TO LEFT ENGINE BLEED FAULT LIGHT AND EICAS MESSAGE DISPLAYED MOMENTARILY . ACCOMPLISHED VISUAL INSPECTION ON BLEED LINES. FOUND GROUND WIRE LOOSE ON PRSOV, RESECURED WIRE, OPS CHECKED GOOD PER MM 36-11-00.SDR NOCA08511Transceiver · inoperativeAIRCRAFT HAD AN AIR TURNBACK INTO LEJ DUE TO RIGHT WX RADAR FAILED AND LEFT SYSTEM ALREADY PLACARD. REMOVED AND CHECKED BOTH WX TRANSCEIVERS AND CHECKED FOR BENT OR CORRODED PINS NO DEFECTS NOTED. REMOVED AND REPLACED LEFT WX TRANSCEIVER AS PER MM 34-43-01. SDR NOCA08411Link Assy · defectiveAIRCRAFT FAILED RUDDER FREEPLAY CHECK AS PER EO 757-27-027 AD 2006-07-23. FOUND LOWER PCA ACTATOR LINK. REMOVED AND REPLACED LINK ASSY AND BUSHING AS PER MM 27-21-20 RIGGING AND OPS CHECK AS PER MM 27-21-00.SDR NOCA06911Module · inoperativeEMERGENCY DECLARED FOR LEFT LANDING GEAR LIGHT FAILED TO ILLUMINATE UPON GEAR HANDLE MOVEMENT TO EXTEND/DOWN POSITION. REPLACED LIGHT MODULE, OPS CHECK NORMAL PER MM 33-16-00.SDR NOCA06311Slide · unwanted deployL4 DOOR EMERGENCY SLIDE DEPLOYED DURING CATERING. REMOVED AND REPLACED L4 DOOR EMERGENCY SLIDE PER NAA TASK CARD 25-66-01-4A, OPS CHECKS NORMAL.SDR NOCA02511Girt Bar · lack of lubeL1 DOOR SLIDE ARM LIGHT STAYS ON WITH DOOR DISARMED. CLEANED AND LUBED GIRT BAR AND OPERATIONAL CHECKED AS PER MM 52-11-25 OPS CHECK GOOD.SDR NOCA02011Light · inoperativeEMERGENCY FLOOR TRACK LIGHTING IS INOP AT ROW 12-17. RELAMPED FLOOR TRACK LIGHT AT ROW 12-17 PER MM 33-51-11, OPS CHECK GOOD.SDR NOCA01911Wire · looseL4 DOOR EXTERIOR EMERGENCY EXIT LIGHT DOES NOT ILLUMINATE. T/S DOOR EXTERIOR LIGHT AND FOUND CENTER CONDUCTOR WIRE LOOSE AT L56 SOCKET SECURED PER SWPM 20-00-00, OPS CHECK GOOD.SDR NOCA01811Switch · obstructedL1 DOOR SLIDE ARM LIGHT STAYS ON WITH DOOR DISARMED. REMOVED DEBRIS FROM L1 DOOR SLIDE ARM SWITCHES, OPS CHECK GOOD PER MM 25-66-00.SDR NOCA01711Girt Bar · obstructedR1 DOOR SLIDE WILL NOT ARM. REMOVED DEBRIS FROM SLIDE GIRT BAR AREA, OPS CHECK NORMAL PER MM 25-66-11.SDR NOCA00711Light · inoperativeEMERGENCY LIGHTS AREA LIGHT SEAT ROW 14D INOP. RELAMPED EMERGENCY LIGHT ROW 14D AS PER MM 33-51-05, OPS CHECK OK.SDR NOCA00611Bulb · burned outEMERGENCY EXIT LIGHT AT L2 DOOR INOP. REPLACED LIGHT AS PER MM 33-51-06, OPS CHECK OK.SDR NOCA07110Lamp · inoperativeL1 EMERGENCY LIGHT EXTERIOR INOP. RE-LAMPED EMERGENCY LIGHT, OPS CHECK OK PER AMM 33-51-00.SDR NOCA02510Support Fitting · corrodedAFT MID LAV, AFT IND LOWER CORNER HAS EVIDENCE OF CORROSION. CLEANED LOWER AFT I/B CORNER OF MID LAV FOUND OUT OF LIMITS IAW B757 AMM 51-00-53. REMOVED LOWER SUPPORT FITTING FROM MID LAV AFT LWR SIDE IAW B757 SRM 51-40-02. REMOVED CORROSION FROM SUPPORT FITSDR NOCA02210Unknown · malfunctionedON INITIAL TAKEOFF ROLL AT ABOUT 40 KNOTS RT RECIRC FAN ANNUNCIATED FOLLOWED BY RIGHT AND LEFT UTILITY BUSES OFF ON EICAS ABORTED TAKEOFF. ACCOMPLISHED FIM 24-51-00 FIG 103 RIGHT GEN SYS AUX CONTACTOR FAULT ON BPCU RESET. RAN BOTH ENGINES AND CYCLED EACH GENSDR NOCA01310Light · inoperativeLEFT AFT LAV FLOOR EMERGENCY LIGHT OUT. DEFERRED PER MEL 33-51-3. REPLACED EMERGENCY FLOOR LIGHT ASSY, AS PER MM 33-51-11, OPS CHECK GOOD ITEM CLOSED.SDR NOCA06909Light · inoperativeEMERGENCY LIGHT INOP AT OVERHEAD BIN 1 ABC. REPLACED LIGHT AS PER MM 33-51-05.SDR NOCA06709Light · brokenEMERGENCY FLOOR PATH LIGHT ASSY LOCK BROKEN AT 26C. REPLACED EMERGENCY FLOOR PATH LIGHT ASSY AS PER MM 33-51-11.SDR NOCA06609Connector · looseEMERGENCY LIGHT INOP L1 DOOR. RESECURED LOOSE CONNECTOR OPS CHECK OK AS PER MM 33-51-05SDR NOCA06509AALamp · burned outEMERGENCY LIGHT INOP AT OVERHEAD BIN 1 ABC. REPLACED LIGHT AS PER MM 33-51-05.SDR NOCA04709Autothrottle Sys · malfunctionedREJECTED TAKEOFF DUE TO A/T DISCONNECT AND AUTOTHROT DISC EICAS LIGHTS ILLUM WITH A/T ENGAGED IN EPR MODE. THRUST REF MODE DISP ON EICAS AND F/S POINTER DISPLAY ON ADI NORM (RTO AT 90 KTS). HIGH ENERGY STOP INSPECTION ACCOMPLISHED / PLACARD A/T INOP PER MEL SDR NOCA04609BBAutothrottle Sys · disconnectedREJECTED TAKEOFF DUE TO A/T DISCONNECT RTO 90 KNOTS. HIGH ENERGY STOP INSPECTION ACCOMPLISHED/ PLACARD A/T INOP PER MEL 22-30-1, ITEM REMAINS OPEN.SDR NOCA03809Apu · inoperativeAPU INFLT START UNSUCCESSFUL, OK ON GROUND.SDR NOCA03609Apu · malfunctionedFLIGHT CREW REPORTED DURING SCHEDULED APU INFLT START APU DID NOT START INFLIGHT. FLIGHT WAS NOT AN ETOPS FLIGHT. OAT (-58 C), ALT FL 390, PEAK EGT 20, 3 ATTEMPTS - NO START. IF START NOT SUCCESSFUL DID APU SHUT DOWN AFTER 95 % ? NO
IF START NOT SUCCESSFUSDR NOCA03209Charger · inoperativeEMERGENCY LIGHTS INOP ROW 12 ABC- 20 ABC. REPLACED BATTERY CHARGER ASSEMBLY AS PER MM 33-51-07.SDR NOCA01409Fuse · blownEXTERIOR EMERGENCY EXIT LIGHT AT DOOR 2R LIGHT IS INOP. REPLACED LIGHT ASSY FUSE AND CLEANED TERMINALS, OPS CHECK GOOD AS PER MM 33-51-00.SDR NOCA01109Eec · faultyN1/EPR FAILED TO ENGAGE TO THRUST WHEN SELECTED ON TAKEOFF ROLL. RT ENGINE LIMITER MESSAGE ILLUMINATED ON EICAS FOR APPROXIMATELY 3 SECONDS THEN EXTINGUISHED. REPLACED RIGHT EEC PER MM 73-21-00.SDR NOCA00309Slide · inoperativeAFTER ENG SHUTDOWN R4 DOOR WAS SLIGHTLY OPENED BY F/A WHILE STILL ARMED. SLIDE DID NOT DEPLOY. ACFT MX FERRY FOR SLIDE REPLACEMENT. REMOVED AND REPLACED DOOR R4 SLIDE AND DOOR ASSIST BOTTLE, BOTTLE P/N OFF - 803300-35, S/N OFF - R23748, OPS CHK NORMAL.SDR NOCA08808Charger · inoperativeFLOOR EMERGENCY LIGHTS AT SEATS 7 AND 8 ABC ARE INOP. REPLACED BATTERY AND CHARGER AS PER MM 33-51-07, OPS CHECK OK.SDR NOCA09008Light · inoperativeR2 DOOR EMERGENCY EXIT LIGHT INOP. REPLACED LIGHT AS PER MM 33-51-07.SDR NOCA08908Battery · dischargedEMERGENCY OVERHEAD BIN LIGHT INOP AT SEAT 11 DEF. REPLACED THE R2 BATTERY ASSY AS PER MM 33-51-07.SDR NOCA08508Transmitter · defectiveABNORMAL ENGINE PARAMETERS DURING CRUISE. REMOVED AND REPLACED LEFT ENG EPR TRANSMITTER PER MM 77-11-01 PERFORMED TEST 13 FOUND OK AS PER MM 71-00-00. FOUND LEFT ENGINE ETPU SENSE LINE LOOSE. SECURED LINE PER MM 70-51-00-912-001-ROO. ACCOMPLISHED HIGH POWESDR NOC2008F00005Buss · overheatedACFT DIVERTED TO STL, SMOKE IN COCKPIT EMERGENCY DECLARED CAPT REPORTS THE RT ACFT BUSS OVERHEATED ITEM REMAINS OPEN. (K)SDR NOCA04108Wire Harness · out of positionRIGHT ENGINE O/H LP 1 STATUS MSG DISPLAYED. CHECKED OVERHEAT SENSORS RESISTANCE AND CHECKED OK. REPOSITIONED HARNESS AND CLEARED CONNECTOR PER MM 26-11-00 AND OPS CHECK OK.SDR NOCA03108Pressure Switch · malfunctionedCENTER HYD SYSTEM PRESS EICAS & OVERHEAD PANEL LIGHT ILLUMINATED ON TAKEOFF ROLL, 60 KTS. T/S PER SSM 29-00-04 FOUND C HYD PRESS SWITCH AT FAULT S10002. REMOVED AND REPLACED S10002 PER MM 29-11-19, ALL OPS OK. PERFORMED SYS CHECK PER MM 29-11-00, ALL OK.SDR NOCA02708Light · inoperativeTOP POSITION LAMP INOP IN EXIT LOCATOR SIGN AT 3R DOOR SIDEWALL. REPLACED LAMP AT 3R EXIT SIGN AS PER MM 33-51-10.SDR NOCA02908Light · inoperativeTHE 2R EMERGENCY LIGHT INOP. RELAMPED 2R EMERGENCY PER MM 33-51-01.SDR NOCA02808Light · inoperativeTOP POSITION LAMP INOP AT 3L DOOR EXIT LOCATOR SIGN AT SIDEWALL. REPLACED LAMP AS PER MM 33-51-10.SDR NOCA03008Light · inoperativeTHE 3L EMERGENCY LIGHT INOP. RELAMPED 3L EMERGENCY LIGHT AS PER MM 33-51-10.SDR NOCA00908Light · inoperativeEMERGENCY STRIP LIGHT OUT ROW 36L. RELAMPED LIGHT, OPS CHECK GOOD PER MM 33-51-05.SDR NOCA17107Actuator · malfunctionedON TAKEOFF OUT OF YQX HAD `L/E SLAT DISAGREE` EICAS CAUTION MESSAGE. AIR TURNBACK TO YQX. ITEM REMAINS OPEN, MX FERRY BACK TO JFK. REPLACED NR 10 L/E ROTARY ACTUATOR PER MM 27-81-18 FLIGHT TEST OK ITEM CLOSEDSDR NOCA17007Electronic Unit · malfunctionedLEADING EDGE SLAT DISAGREE MESSAGE AIR TURNBACK INTO KWI. FLAP/SLAT ELECTRONIC UNIT BITE (FSEU) PER FIM 27-51-00 FIG 104B UNABLE TO DUPLEATE SWAPPED FSEU NR 1 BOX P/N 285N0011-40 S/N D02243 TO NR 3 BOX POSITION S/N 2244 PER BLOCK NR 16 ALSO ACCOMPLISHED FIM 2SDR NOCA16907Switch · faultyLEADING EDGE SLAT DISAGREE EICAS MSG WHILE RETRACTING FLAPS 1 TO 0 AIR TURNBACK TO JFK. T/S PER FIM TASK 27-51-00 FIG 104B AND 115 FOUND SWITCH S1 CONNECTOR AT FAULT. REMOVED AND REPLACED S1 SWITCH AS PER MM 27-51-29 ACOMP REQ, OPS CHECKS OK.SDR NOCA14807Pump · failedON TAXI IN GEO RAMP LEFT ENG SHUT DOWN (UNCOMMANDED) PERFORMED FIM 73-11-00. REMOVED AND REPLACED HP AND LP FUEL PUMP AS PER MM 73-11-01 & 73-11-03 RAN ENG AND PERFORMED RUNUP TEST PER 71-00-00, OPS CHECK OK.SDR NOCA14507Adc · malfunctionedREJECTED TAKEOFF DUE TO NO AIRSPEED INDICATION ON CAPT AIRSPEED INDICATOR. REPLACED AIRSPEED INDICATOR AND LEFT AIR DATA COMPUTER ITEM REMAINS OPEN, SECOND TIME REJECTED TAKEOFF DUE TO NO AIRSPEED INDICATION ON CAPTAINS AIRSPEED INDICATOR. REPLACED NR 1 ADCSDR NOCA14207Slide · unwanted deployL1 SLIDE DEPLOYED ON GROUND. REMOVED AND REPLACED L1 SLIDE AS PER MM 52-11-33 SYSTEM CHECK OK ACCOMPLISHED EO 757-25-199.SDR NOCA13607Wire · brokenSECTION OF E-PATH LIGHTING INOP AT L3 DOOR. FOUND BROKEN WIRE IN A FEW SPOTS AND RE-SPLICED WIRE, OPS CHECK GOOD.SDR NOCA10207Blower · malfunctionedTHE -AFT DET FAN- STATUS MESSAGE ON EICAS. REMOVED AND REPLACED NR 3 AFT BLOWER IAW AMM 26-16-02 AND REMOVED AND REPLACED BLOWER NR 3 RELAY K10379 BLOWER RELAY P/N OFF TDH8116-6002, S/N OFF, P/N ON TDH8116-6002, S/N ON 8-11-06-1 IAW WDM 26-16-21. OPS CHECKSSDR NOCA10107Control Unit · malfunctionedLEFT ENG EXCEEDANCE EGT AND N2 ON TAKEOFF ROLL FOR LESS THAN ONE SECOND. REMOVED AND REPLACED NR 1 ENG BVCU IAW MM 75-32-01. IDLE RUN DONE. BVCU BITE CKS OK IAW 71-00-00 & 75-32-00. HIGH POWER RUN ACCOMPLISHED TEST 3. PERFORMED OF 71-00-00. ENG CHECKS OKSDR NOCA09707Trans Panel · corrodedLIGHT SCATTERED CORROSION TRANSITION PANEL STA 1530-1640 LEFT SIDE. REMOVED CORROSION, TREATED, PRIMED AND PAINTED AS PER SRM 51-10-01 AND 51-20-01.
Back to N750NA