N760AS

Service difficulty reports not matched to an aircraft · 283

They name N760AS, but no registry record covers the date, the aircraft registered then was built later, or the report describes another aircraft. Newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE n_number = 'N760AS' AND registry_match IS NULL
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR ASAA9940157Battery Pack · dischargedANC - DURING MAINTENANCE CHECK, THE EMERGENCY EXIT FLOOR TRACK LIGHTS IN THE FIRST CLASS CABIN OPERATED NORMALLY INITIALLY AND THEN BECAME INOPERATIVE. REPLACED BATTERY PACK AND LIGHTS OPERATED NORMALLY. (X)Oct 21, 1999 · N760AS · Boeing 7374Q8 · Emergency LightingSDR ASAA9940131Support · crackedPHX - DURING SCHEDULED SI CHECK, THE RT AILERON INBOARD HINGE SUPPORT WAS FOUND TO BE CRACKED AT THE NUTPLATE, OUTBOARD SIDE. REPAIRED PER EA 5740-01177. (M)Jun 8, 1999 · N760AS · Boeing 7374Q8 · AileronsSDR ASAA9940130Chord · corrodedPHX - DURING SCHEDULED SI CHECK, THE RIGHT INNER CHORD AT THE R2 DOOR STATION 947.5 TO 957.5 WAS FOUND TO BE CORRODED. REPAIRED PER SRM 51-40-02. (M)Jun 8, 1999 · N760AS · Boeing 7374Q8 · Fuselage Miscellaneous StructureSDR ASAA9940129Floorbeam · corrodedPHX - DURING SCHEDULED SI CHECK, THE FLOORBEAM CAP UPPER SURFACE AT STATION 344, LBL 40-56 WAS FOUND TO BE CORRODED. REPAIRED PER SRM 53-00-51, FIG 203. (M)Jun 8, 1999 · N760AS · Boeing 7374Q8 · Fuselage Main, Floor BeamSDR ASAA9940128Skin · lightning strikePHX - DURING SCHEDULED SI CHECK, THE EXTERNAL FUSELGE SKIN AT BS 360, STRINGER 17L WAS FOUND TO HAVE 2 LIGHTNING STRIKES. REPAIRED PER SRM 53-00-01, FIG 223. (M)Jun 8, 1999 · N760AS · Boeing 7374Q8 · Fuselage Main, Plate/SkinSDR ASAA9940127Floorbeam · damagedPHX - DURING SCHEDULED SI CHECK, THE TOP FLANGES OF THE FLOORBEAM AT STATION 986.5, LBL 33 - RBL 30 WERE FOUND TO BE GOUGED AND CORRODED. REPAIRED PER EA 5310-01697. (M)Jun 8, 1999 · N760AS · Boeing 7374Q8 · Fuselage Main, Floor BeamSDR ASAA9940126Floorbeam · corrodedPHX - DURING SCHEDULED SI CHECK, THE FORWARD AND AFT FLANGES OF THE FLOORBEAM AT STATION 947.5, LBL 12-RBL 10 WERE FOUND TO BE CORRODED. REPAIRED PER EA 5310-01702. (M)Jun 8, 1999 · N760AS · Boeing 7374Q8 · Fuselage Main, Floor BeamSDR ASAA9940125Frame · dentedPHX - DURING SCHEDULED SI CHECK, THE AFT CARGO COMPARTMENT TOP OF MAIN FRAME WAS FOUND TO BE DENTED AT BS 727E 30 INCHES BELOW STRINGER 22R AND BS 727F ABOVE STRINGER 25R. REPAIRED PER EA 5310-01701. (M)Jun 8, 1999 · N760AS · Boeing 7374Q8 · Fuselage Main, FrameSDR ASAA9940124Floorbeam · corrodedPHX - DURING SCHEDULED SI CHECK, THE FLOORBEAM CAP UPPER SURFACE AT STATION 312 LBL 12 TO RBL 12 WAS FOUND TO BE CORRODED. REPAIRED PER SRM 53-10-01 FIG 205. (M)Jun 8, 1999 · N760AS · Boeing 7374Q8 · Fuselage Main, Floor BeamSDR ASAA9940123Floorbeam · corrodedPHX - DURING SCHEDULED SI CHECK, THE FORWARD AND AFT TOP FLANGED OF THE FLOORBEAM AT STATION 967, LBL 14-21 AND 23-33 WAS FOUND TO BE CORRODED. REPAIRED PER SRM 53-00-51 FIG 202. (M)Jun 8, 1999 · N760AS · Boeing 7374Q8 · Fuselage Main, Floor BeamSDR ASAA9940058Wire · failedSEA - DURING MAINTENANCE CHECK, THE EMERGENCY EXIT TRACK LIGHTING WAS FOUND TO BE INOPERATIVE AT ROWS 6-9. REPLACED WIRING HARNESS AT ROW 6, LIGHTS OPERATED NORMALLY. (M)Mar 1, 1999 · N760AS · Boeing 7374Q8 · Light System WiringSDR ASAA9840072Connector · looseKTN - FLT 73 - PRIOR TO FLT, THE EMERGENCY EXIT FLOOR TRACK LIGHTS AT ROW 22-25 WOULD NOT ILLUMINATE DURING TEST. SECURED LOOSE CONNECTOR AT ROW 25 AND LIGHTS OPERATED NORMALLY. (M)Jun 10, 1998 · N760AS · Boeing 7374Q8 · Emergency LightingSDR ASAA9540103Wire · disconnectedSEA - FLT NR 62 - CREW REPORTED AFT 4 EMERGENCY EXIT FLOOR TRACK LIGHTS WERE INOPERATIVE. RECONNECTED WIRING AND LIGHTS OPERATED NORMALLY. (M)Dec 5, 1995 · N760AS · Boeing 7374Q8 · Light System WiringSDR ASAA9540101Wire · disconnectedSEA - FLT NR 279 - CREW REPORTED, AFT MOST SECTION OF EMERGENCY EXIT FLOOR TRACK LIGHTING WAS INOPERATIVE. INSTALLED NEW LENS COVER AND SECURED TRACK AND WIRING, LIGHTS OPERATED NORMALLY. (M)Dec 3, 1995 · N760AS · Boeing 7374Q8 · Light System WiringSDR ASAA9540094End Stop · defectiveSEA - DURING MAINTENANCE CHECK, THE AFT 5 EMERGENCY EXIT FLOOR TRACK LIGHTS WERE FOUND INOPERATIVE. REPLACED END STOP SECTION AND LIGHTS OPERATED NORMALLY. (M)Nov 16, 1995 · N760AS · Boeing 7374Q8 · Emergency LightingSDR ASAA9540093Eel Wiring · disconnectedSEA - DURING MAINTENANCE CHECK, THE AFT 5 EMERGENCY EXIT FLOOR TRACK LIGHTS WERE FOUND INOPERATIVE. RECONNECTED WIRING AND LIGHTS OPERATED NORMALLY. (X)Nov 15, 1995 · N760AS · Boeing 7374Q8 · Emergency LightingSDR ASAA9540091Wire · disconnectedJNU - DURING MAINTENANCE CHECK, THE AFT 4 EMERGENCY EXIT FLOOR TRACK LIGHTS WERE FOUND INOPERATIVE. RECONNECTED WIRING AND LIGHTS OPERATED NORMALLY. (X)Nov 14, 1995 · N760AS · Boeing 7374Q8 · Light System WiringSDR ASAA9540090Eel Wiring · disconnectedJNU - DURING MAINTENANCE CHECK, THE EMERGENCY EXIT FLOOR TRACK LIGHTS AT ROWS 22 THROUGH 26 WERE FOUND INOPERATIVE. RECONNECTED WIRING AND LIGHTS OPERATED NORMALLY. (X)Nov 14, 1995 · N760AS · Boeing 7374Q8 · Emergency LightingSDR ASAA9540089Eel Wiring · disconnectedSEA - FLT 625 - THE AFT 4 EMERGENCY EXIT FLOOR TRACK LIGHTS WERE INOPERATIVE. RECONNECTED WIRING AT AFT GALLEY NR 3 AND LIGHTS OPERATED NORMALLY. (X)Nov 12, 1995 · N760AS · Boeing 7374Q8 · Emergency LightingSDR ASAA9540087Eel Wiring · disconnectedSEA - DURING MAINTENANCE CHECK, THE EMERGENCY EXIT FLOOR TRACK LIGHTS WERE FOUND INOPERATIVE FROM ROW 25 AFT. RECONNECTED WIRING AT ROW 25 AND LIGHTS OPERATED NORMALLY. (X)Nov 11, 1995 · N760AS · Boeing 7374Q8 · Emergency LightingSDR ASAA9540086Eel Wiring · disconnectedSEA - DURING MAINTENANCE CHECK, THE AFT 3 EMERGENCY EXIT FLOOR TRACK LIGHTS WERE FOUND INOPERATIVE. RECONNECTED WIRING ON AFT TRACK AND LIGHTS OPERATED NORMALLY. (X)Nov 8, 1995 · N760AS · Boeing 7374Q8 · Emergency LightingSDR ASAA9540082Eel Wiring · disconnectedJNU - DURING MAINTENANCE CHECK, THE AFT 3 EMERGENCY EXIT FLOOR TRACK LIGHTS WERE FOUND INOPERATIVE. RECONNECTED WIRING ON AFT TRACK AND LIGHTS OPERATED NORMALLY. (X)Nov 7, 1995 · N760AS · Boeing 7374Q8 · Emergency LightingSDR ASAA9540073Eel Wiring · disconnectedSEA - FLT NR 191 - CREW REPORTED AFT SECTION OF EMERGENCY EXIT FLOOR TRACK LIGHTS INOPERATIVE. REPAIRED WIRING CONNECTION ON AFT TRACK AND LIGHTS OPERATED NORMALLY. (M)Oct 27, 1995 · N760AS · Boeing 7374Q8 · Emergency LightingSDR ASAA9540068Eel Wiring · disconnectedSEA - DURING MAINTENANCE CHECK, THE FORWARD AND AFT THREE EMERGENCY EXIT FLOOR TRACK LIGHTS WERE FOUND INOPERATIVE. RECONNECTED WIRING AT FORWARD AND AFT TRACKS AND LIGHTS OPERATED NORMALLY. (M)Oct 18, 1995 · N760AS · Boeing 7374Q8 · Emergency LightingSDR ASAA9540059Eel Wiring · disconnectedANC - DURING MAINTENANCE CHECK, THE AFT THREE EMERGENCY EXIT FLOOR TRACK LIGHTS WERE FOUND INOPERATIVE. RECONNECTED AFT FLOOR TRACK WIRING AND LIGHTS OPERATED NORMALLY. (M)Sep 25, 1995 · N760AS · Boeing 7374Q8 · Emergency LightingSDR ASAA9540042Eel Assy · inoperativeSEA - DURING MAINTENANCE CHECK, THE FORWARD RED EMERGENCY EXIT FLOOR TRACK LIGHT WAS FOUND INOPERATIVE. REPLACED LIGHT ASSEMBLY AND OPERATED NORMALLY. (M)Aug 3, 1995 · N760AS · Boeing 7374Q8 · Emergency LightingSDR ASAA9540041Eel Wiring · disconnectedSEA - DURING MAINTENANCE CHECK, THE AFT THREE EMERGENCY EXIT FLOOR TRACK LIGHTS WERE FOUND INOPERATIVE. RECONNECTED LIGHTS AND OPERATED NORMALLY. (M)Aug 3, 1995 · N760AS · Boeing 7374Q8 · Emergency LightingSDR ASAA9540039Eel Wiring · disconnectedSEA - CHECK, AFT THREE TRACK LIGHTS INOP. MAINTENANCE RECONNECTED LIGHTS. (W)Jul 5, 1995 · N760AS · Boeing 7374Q8 · Emergency LightingSDR ASAA9540037Eel Wiring · disconnectedSEA - CHECK, AFT THREE TRACK LIGHTS INOP. MAINTENANCE RECONNECTED WIRING. (W)Jul 4, 1995 · N760AS · Boeing 7374Q8 · Emergency LightingSDR ASAA9540027Eel Wiring · disconnectedSEA - AFT THREE PEEPLS LIGHTS INOP. MAINTENANCE RECONNECTED WIRING. (M)Jun 15, 1995 · N760AS · Boeing 7374Q8 · Emergency LightingSDR ASAA9540012Eel Wiring · disconnectedSEA - DURING MAINTENANCE CHECK, THE FORWARD FOUR AND AFT FLOOR TRACK EMERGENCY EXIT LIGHTS WERE FOUND INOPERATIVE. RECONNECTED WIRING AND LIGHTS OPERATED NORMALLY. (W)Mar 22, 1995 · N760AS · Boeing 7374Q8 · Emergency LightingSDR ASAA9569Eel Track · damagedSEA - PILOT REPORTED, LAST 5 EMERGENCY TRACK LIGHTS DO NOT ILLUMINATE. REPLACED LIGHT SECTION AT ROW 26 AND SECURED LIGHT LENS. (W)Feb 13, 1995 · N760AS · Boeing 7374Q8 · Emergency LightingSDR ASAA9531Eel Wiring · loosePDX - CHECK, FLOOR TRACK LIGHTS INOP AT ROWS 28-36. MAINTENANCE RECONNECTED LOOSE BUS WIRE IN TRACK. (W)Jan 21, 1995 · N760AS · Boeing 7374Q8 · Emergency Lighting
Back to N760AS