N761ND
Service difficulty reports · 214
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N761ND' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N761ND' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ASOA2013052903681Sill · corrodedASD LOWER SILL CORRODED SEVERAL PLACES. R & R ANGLES IAW SRM 51-42-06-001-001-A01 AND 51-42-21-001-001-A01.SDR ASOA2013052903680Frame · crackedTRU FLOOR PAN CRACK RT SIDE AFT CORNER OF AFT FRAME OF TRU DOOR OPENING TO SCUPPER OF ADG PUMP. REPAIRED IAW EC/TC REO 670-53-11-509 AND GENERIC REO 670-53-11-509 REV.SDR ASOA2012122002684Battery · dischargedEMERGENCY LIGHTS WOULD NOT STAY ON MORE THAN 3 SECONDS WHEN SELECTED ON. RE-CHARGED EMERGENCY LIGHTS IAW AMM 24-32-07. OPS CHECKED GOOD AT THIS TIME.SDR ASOA2012062701827Light · missingEMERGENCY LIGHT AT 12AB MISSING. REPLACED EMERGENCY LIGHT IAW AMM 33-51-01.SDR ASOA2012061401799Insulator · damagedLEFT BLEED DUCT WARNING MESSAGE IN CLIMB. CONTINUED, PRESSURIZED, AND EMERGENCY DECLARED. MDC INDICATES LT BLEED LOOP A OPEN. REPAIRED LT BLEED LOOP A BY REMOVING AND REPLACING CERAMIC INSULATORS ON PLUGS MT139P1 AND MT141P1 OF LOOPS MT139 & MT141 IAW AMM SDR ASOA201201781Controller · unserviceableLEFT BLEED DUCT WARNING MESSAGE IN FLIGHT. LOST CABIN PRESSURE. DECLARED AN EMERGENCY. ACFT RETURNED TO DEPARTURE. R & R ANTI-ICE CONTROLLER IAW 30-12-12 PERFORMED SUCCESSUL OPS CHECK. PERFORMED OPS CHECK OF THE LT PACK IAW AMM 21-51-00, REF 30-12-12 ITEM NSDR ASOA201201544Warning Light · false activationLEFT BLEED DUCT WARNING, FOLLOWED QRH PROCEDURES ACFT RETURNED TO DEPARTURE, EMERGENCY DECLARED. PERFORMED LEAK TEST, INSPECTION AND CONTINUITY CHECK OF LT BLEED AIR SYS AND LT BLEED LOOP B IAW FIM TASK 36-21-01 AND AMM 36-10-00. LEAK TESTED GOOD. OPS CSDR ASOA201200981Controller · inoperativeLEFT BLEED WARNING, ACFT RETURNED TO DEPARTURE AFTER T/O. EMERGENCY DECLARED. R & R AILC IAW AMM 30-12-12, OPS CHECKED GOOD.SDR ASOA201200536Megaphone · inoperativeF/A MEGAPHONE INOPERATIVE. REPLACE MEGAPHONE.SDR ASOA201200533Megaphone · inoperativeMEGAPHONE INOPERATIVE. REPLACED MEGAPHONE IAW AMM 25-61-05.SDR ASOA201200082Unknown · odorSTRONG ODOR OF EXHAUST FUMES IN CABIN IN FLIGHT AND ON GROUND. OPS CHECKED LT PACK IAW AMM 21-51-00-710-801. CHECKED GOOD. OK FOR SERVICE.SDR ASOA201102287Light · separatedEMERGENCY LIGHT SEPARATED AFT OF RT EMERGENCY EXIT. R & R FLOOR EMERGENCY LIGHT IAW AMM 33-51-01.SDR ASOA201101685Precooler · failedLEFT BLEED DUCT WARNING MESSAGE IN FLIGHT., ACFT DIVERTED, EMERGENCY DECLARED. R & R LT PRE-COOLER ASSY IAW AMM 21-53-04. R & R T DUCT IAW AMM 21-61-12. ALL OPS AND LEAK CHECKED GOOD.SDR ASOA201101495Controller · failedLEFT BLEED DUCK WARNING MESSAGE CAME COME ON DURING CLIMBOUT. LANDING RATE LESS THAN 200 FPM. (ACFT RETURNED AFTER T/O -- EMERGENCY DECLARED AS A PRECAUTION) R & R IAW AMM 30-12-12. RUN ENGS OPS CHECK GOOD. (CLOSED)SDR ASOA201101371Door · bindingPAX DOOR WILL NOT OPEN. PERFORMED OPS CHECK OK AT THIS TIME IAW AMM 52-11-00. ACFT OK FOR SERVICE.SDR ASOA201101130Megaphone · weakF/A REPORTS MEGAPHONE IS WEAK. REPLACED MEGAPHONE BATTERY. OPS CHECKED GOOD IAW AMM 25-61-14.SDR ASOA201101076Seat Track · gougedRT 7 SIDEWALL SEAT TRACK GOUGED. R & R RT NR 7 SIDEWALL SEAT TRACK IAW REO 670-53-00-314 AND 670-53-00-074 THIS IS CONSIDERED A MAJOR REPAIR RII FOUND TO BE SATISFACTORY.SDR ASOA201100929Seat Track · corrodedLT NR 6 SIDEWALL SEAT TRACK HAS CORROSION DAMAGE. REMOVED CORROSION FROM SEAT TRACK AND FOUND TO BE WITHIN REPAIRABLE LIMITS IAW SRM 53-51-49.SDR ASOA201100928Seat Track · corrodedLT NR 5 SIDEWALL SEAT TRACK HAS CORROSION DAMAGE. R & R SEAT TRACK IAW REO 670-53-00-314 AND AMM 53-00-49. MAJOR REPAIR.SDR ASOA201100927Seat Track · corrodedLT NR4 SIDEWALL SEAT TRACK HAS CORROSION DAMAGE. R & R SEAT TRACK IAW SRM 53-00-49 AND REO 670-53-00-314. MAJOR REPAIR.SDR ASOA201100926Seat Track · corrodedRT NR 6 SIDEWALL SEAT TRACK HAS CORROSION DAMAGE. R & R SEAT TRACK IAW REO 670-53-00-314. MAJOR REPAIR.SDR ASOA201100925Seat Track · corrodedRT NR 5 SIDEWALL SEAT TRACK CORRODED. BLENDED SEAT TRACK AND FOUND TO BE IN LIMITS IAW SRM 53-51-49.SDR ASOA201100924Seat Track · corrodedRT NR 4 SIDEWALL SEAT TRACK HAS CORROSION DAMAGE. R & R SEAT TRACK IAW AMM 53-00-49 AND REO 670-53-314. MAJOR REPAIR.SDR ASOA201100923Intercostal · corrodedPAX DOOR AFT INTERCOSTAL CLOSE TO DOOR HINGE IS CRACKED IN RADIUS. REMOVED INTERCOASTAL AND INSTALLED SERVICEABLE AFT INTERCOASTAL IAW SRM 51-42-06 AND SRM 51-42-21. MAJOR REPAIR.SDR ASOA201100922Step · corrodedCORROSION BY PAX DOOR UPPER STEP ON AFT STAIR WEB. REMOVED CORROSION IAW SRM 51-11-04. MINOR REPAIR.SDR ASOA201100921Drag Angle · crackedPAX DOOR AFT DRAG ANGLE CRACKED NEAR ASSIST MOTOR PULLEY. REPAIRED DAMAGED PAX DOOR AFT DRAG ANGLEIAW REO 670-52-11-072. A MAJOR REPAIR.SDR ASOA201100920Placard · deterioratedPAX DOOR "EXIT" PLACARD ON 2ND STEP IS DETERIORATED. R & R PLACARD IAW AMM 20-60-04.SDR ASOA201101068Seat Track · corrodedLEFT NR 2 FLOOR SEAT TRACK HAS MINOR SURFACE CORROSION IN 2 EA PLACES. REMOVED AND REPLACED LT NR 2 FLOOR SEAT TRACK WITH NEW IAW REO 670-53-00-314. THIS IS A MAJOR REPAIR.SDR ASOA201100916Floorbeam · corrodedLT FS 280 FLOORBEAM CORRODED AROUND FASTENER HOLES. R & R LT SIDE BEAM FS 280.00 WITH NEW IAW SRM 51-42-06, 51-42-13, AND 51-42-21.SDR ASOA201100907Seat Track · corrodedLT NR 3 FLOOR SEAT TRACK CORRODED. BLENDED MINOR SURFACE CORROSION, REMAINING MATERIAL IS WITHIN SERVICABLE LIMITS IAW SRM 53-21-49.SDR ASOA201100906Seat Track · corrodedRT NR 3 FLOOR SEAT TRACK CORRODED. REMOVED SEAT TRACK AND REPLACED WITH SERVICABLE SEAT TRACK IAW REO 670-53-00-314 AND EC/TC REO 670-53-00-314. MAJOR REPAIR.SDR ASOA201100904Seat Track · corrodedRT NR 2 FLOOR SEAT TRACK CORRODED NUMEROUS PLACES. R & R SEAT TRACK IAW AMM 53-00-49 AND REO 670-53-00-314. MAJOR REPAIR.SDR ASOA201100903Seat Track · corrodedRT NR 1 FLOOR SEAT TRACK CORRODED NUMEROUS AREAS. REMOVED SEAT TRACK IAW AMM 53-00-49-000-801. INSTALLED NEW SEAT TRACK IAW AMM 53-00-49-400-801 AND EC/TC REO 670-53-00-314.SDR ASOA201100902Seat Track · corrodedLT NR 1 FLOOR SEAT TRACK CORRODED AT FWD END. REMOVED SEAT TRACK AND INSTALLED NEW IAW AMM 53-00-49-000-0801.SDR ASOA201100901Placard · tornCREW ESCAPE HATCH EXTERIOR PLACARDS TORN AND FADED. REMOVED AND INSTALLED SERVICEABLE PLACARDS IAW AMM 20-60-11.SDR ASOA201001417Circuit Breaker · trippedFLAPS FAIL 30 CAUTION, EMERGENCY DECLARED. FLAPS FAIL RESET RESET IAW AMM 05-51-51-970-801-A01 RESET PROCEDURES. AS PER MCC, NO FURTHER ACTION IS REQUIRED.SDR ASOA201000763Socket · brokenGALLEY 3 FLOOR LEVEL EMERGENCY FLOODLIGHT DS155 LAMP SOCKET IS BROKEN. R & R GALLEY 3 FLOOR LEVEL EMERGENCY FLOOD LIGHT DS155 IAW AMM 33-51-11 OPS GOOD DEFER CLEARED PLACARD REMOVED.SDR ASOA201000422Switch · loosePAX DOOR DIFFICULT TO OPEN. FOUND SWITCH (POWER ASSIST) LOOSE IN SWITCH RETAINER SECURED SWITCH OPS CK GOOD MM 20-41-00 52-11-08.SDR ASOA201000308Flashlight · inoperativeCAPT'S FLASHLIGHT INOP. REPLACED CAPT'S FLASH LIGHT, OPS CHECK GOOD IAW AMM 25-60-00.SDR ASOA200901176Light · inoperativeAFT GALLEY LOWER EMERGENCY LIGHT INOP.SDR ASOA200900862Attach Angle · crackedLOWER WEB ATTACH ANGLE (CC670-34117-6) AT FS 280, RBL 26, CRACKED.SDR ASOA200900849Web · crackedLEFT 280 WEB FOUND CRACKED. CORROSION REMOVED PER BLENDING. BLEND WITHIN ALLOWABLE LIMITS. APPLIED A023 FINISH TO BLENDED AREA. ALL WORK ACCOMPLISHED PER SRM.SDR ASOA200900848Crossbeam · crackedRT 280 CROSSBEAM FOUND CRACKED. REMOVED AND REPLACED.SDR ASOA200900847Crossbeam · corrodedLT 280 CROSSBEAM CORRODED. REMOVED AND REPLACED.SDR ASOA200900845Drag Angle · crackedLEFT AFT DRAG ANGLE FOUND CRACKED. REMOVED AND REPLACED LT AFT DRAG ANGLE, APPLIED FAY SEAL AND A023 FINISH TO AREA IAW SRM 51-40-11 AND 51-41-02 AND DRAWING BA670-35002.SDR ASOA200900844Structure · corrodedSEVERAL AREAS MARKED FOR CORROSION AND PAINT MISSING BETWEEN FS 1047 AND AFT EQUIPMENT BAY CUTOUT.SDR ASOA200900842Handle · stickingRIGHT OVERWING EMERGENCY EXIT RELEASE HANDLE STICKING.SDR ASOA200900841Placard · damagedASD STEP "EXIT" PLACARD DAMAGED.SDR ASOA200801393Light · unknownREFER TO AFDL 447034-3 EMERGENCY LIGHTS.SDR ASOA200801392Light · unknownREFER TO AFDL 447034-3 EMERGENCY LIGHTS.
Back to N761ND