N76523
Service difficulty reports · 38
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N76523' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N76523' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2026020513596Power Supply · inoperativeEMERGENCY LIGHTING INOPERATIVE AT AISLE SEATS 15 / 20 / 21. REMOVED AND REPLACED POWER SUPPLY AND BATTERY M1694 IAW AMM 33-51-06-960-806, OPS CHECKED NORMAL.SDR CALA2026010812802Door · missingMIGRATED SHIM (P/N) 311A2103-4) AT RIGHT PYLON THRUST REVERSER STRUT FAIRING. PERFORM AN INSPECTION OF THE INBOARD SHIM AT THE RIGHT PYLON THRUST REVERSER STRUT FAIRING INSTALLATION PER PART 2 OF ECRA 5450-0302. 9 PERFORM AN INSPECTION OF THE INBOARD SHIM ATSDR CALA2025122412419Door · missingOPS REPORTED ON ARRIVAL TO LIR EXTERIOR LAV SERVICE DOOR MISSING. MISSING LAV SERVICE DOOR ASSY ON ARRIVAL TO LIR. SERVICE DOOR PLACED ON CDL 52D AND PDA CONDITIONAL INSPECTION COMPLETED REF AMM TASK 05-51-59-200-801 SDR SELECTED AS REQUIRED PER GMM 02-30-95.SDR CALA2025113011596Latch · unsecureDOOR L1 SLIDE ASSEMBLY LOOSE AND HAS METAL TAB STICKING OUT. SECURED LATCH ASSEMBLY AT BASE OF BUSTLE IN PLACE AS REQUIRED REF AMM 25-66-01-400-804. OK TO CONTINUE.SDR CALA2025111811327Girt Bar · misinstalledR1 GIRT BAR STUCK. GIRT BAR WAS INCORRECTLY STOWED BY PREVIOUS CREW, RESTOWED GIRT BAR PROPERLY DUE TO GIRT BAR REMOVED AND RE STOWED, VIEWED SAFETY DEMO VIDEO FOR SLIDE SAFETY OBSERVER.SDR CALA2025102810662Charger · inoperativeEMERGENCY LIGHTING SYSTEM OPERATIONAL CHECK. R2 DOOR EMERGENCY EXIT SIGNS TURN OFF APPROX 30 SEC AFTER SWITCHING EMERGENCY LIGHTS TO ON REPLACED BATTERY PACK OF THE AFT RT CHARGER REF AMM 33-51-06-960-805. AFTER FULL HOUR OF CHARGE ONLY GOT 5 SEC OF LIGHT FRSDR CALA2025102010301Seal · damagedOVR HEAD SLIDE TAMPER INDICATOR DAMAGED AT SEAT ROW 25. REPLACED OVR HEAD SLIDE TAMPER INDICATOR AT SEAT ROW 25.SDR CALA2025091008718Lamp · inoperativeAFT WALL RIGHT SIDE EMERGENCY EXIT LIGHT INOPERATIVE. REMOVE AND DISASSEMBLE AFT WALL RIGHT SIDE EMERGENCY EXIT LIGHT. REMOVED AND REPLACED ALL 5 WL 3071 BPEGPL LAMPS AND REASSEMBLE EXIT LIGHT. OPS CHECK GOOD.SDR CALA2025071806734Skin · corrodedCORROSION AT FWD CARGO DOOR CUTOUT AFT INTERNAL SKIN. ACCOMPLISHED REPAIR AT FWD CARGO DOOR SURROUND AFT EDGE BEARSTRAP IAW EC/RA 5330-07563.SDR CALA2025071806733Skin · crackedCRACK FOUND AT LEFT HORIZONTAL STABILIZER LOWER SKIN AT STAB STA 147.90 ,17" FROM REAR SPAR, I/B ROW. .REMOVED EXISTING REPAIR AT LT HORIZ STAB LOWER SKIN AT HSS 147.90.17, FABRICATED NEW REPAIR DOUBLER & FILLERS, INSTALLED IAW SRM 55-10-01-2R-11 & SRM 51-40-SDR CALA2025070106108Skin · crackedEXT PWR RECEPTACLE CUT OUT INNER DOUBLER CRACKED AT LWR END. ACCOMPLISHED REPAIR AT EXT PWR RECEPTACLE CUT OUT INNER DOUBLER REF SRM 53-10-15-2R-4.SDR CALA2025053005121Power Supply · failedEMERGENCY LIGHT BATTERY PACK FOR SEATS 22ABC TO 30ABC FLOOR PROXIMITY LIGHTS IS WEAK. SUPPORT TASK NSA EMX NR 00053 COMPLETED SDR BATTERY PACK DIDNT FIX THE ISSUE REFRENCE LP # 5010177 REMOVED AND REPLACED EMERGENCY POWER SUPPLY-BATTERY PACK AT M167 0 IAW AMM SDR CALA2025052905079Floorbeam · corrodedF.S 344 AT APPROX. RBL 42 TOP SIDE OF FLOOR BEAM UPPER CAP HAS CORROSION. REPAIRED FROM RBL 42 TO 37. REPAIRED FLOORBEAM AT STA 344 RBL 37 IAW SRM 53-10-51- 2R REPAIR 10 AND IAW ECRA 5310-08607, REPAIRED FLOOR BEAM AT STA 344 RBL 37 IAW SRM 53-10-51- 2R REPSDR CALA2025011601932Pump · faultyAPU AUTO SHUTDOWN IN FLIGHT. RESTARTED- AUTOSHUTDOWN AGAIN.UPDATED MAA CODE FIX USING VENDOR MAA SCREEN PLEASE CONTACT TOMC BEFORE COMMENCING ANY WORK. PERFORM THE APU BITE PROCEDURE PER AMM TASK 49-61-00-700-801. PLEASE TROUBLESHOOT PER FIM 49-90 TASK 803 ANSDR CALA2022090702306Skin · noneDURING C-SCAN INSPECTION EA5510-01843 OP 1 AT GYR, CRACK FOUND AT LH HORIZONTAL STAB LOWER SURFACE AT APPROX STA 120.30. TOTAL FLIGHT CYCLES, INTERVAL 9000 FLIGHT CYCLES. INFO TRANSCRIBED FROM AERSALE NON-ROUTINE CARD 23472. LH HORIZONTAL STAB LOWER SURFACE SSDR CALA2022090702298Skin · crackedDURING C-SCAN INSPECTION EA5510-01843 OP 1 AT GYR, CRACK FOUND AT LH HORIZONTAL STABILIZER LOWER SURFACE AT APPROX STA 129.50 TOTAL FLIGHT CYCLES, INTERVAL 9000 FLIGHT CYCLES. INFO TRANSCRIBED FROM AERSALE NON-ROUTINE CARD 23471. LH HORIZONTAL STAB LOWER SURFASDR CALA2021061400868Static Wick · out of tolerancePAX REPORTED AND VIDEO RECORDED SPARKING BTWN NBR1 FLAP FAIRIN G AND TRAILING EDGE FLAP SUSPECT ARCING WAS STATIC DISCHARGING. PERFORMED GV INSP OF AREA AROUND THE REPORTED SITE OF ARCING WHERE THE #1 TE AFT FLAP MEETS THE #1 CANOE AND UNDER THE #1 FLAP FAISDR CALA2021052600736Skin · damagedREFERENCE 6258300. AIRCRAFT SUSTAINED FUSELAGE BELLY SKIN DAMAGE FROM STA.857 TO 927, FROM S-27L TO S-27R. REMOVED FASTENERS PER AVO ESC200513-0523-1 STEP A.1. NEED TO PERFORM DETAILED VISUAL INSPECTIONS PER AVO ESC200513-0523-1 STEPS A.2 THRU A.4. ESC200513-0SDR CALA2021052400732Buttstrap · wornBUTT STRAP AT STA.887 BETWEEN S-27L AND S-27R IS WORN THROUGH. REMOVED SHEAR TIE AT STA887 STR27L TO 26L REF SRM 51-40-02 REMOVED SHEAR TIE STA887 FROM STR27R TO 26R REF SRM 51-40-02 REMOVED INTERCOSTAL FROM STA887 TO 867 BETWEEN STR27L AND STR26L REF SRM 51-4SDR CALA2021051700685Skin · damagedREFERENCE 6258300. AIRCRAFT SUSTAINED FUSELAGE BELLY SKIN DAMAGE FROM STA.857 TO 927, FROM S-27L TO S-27R. ACCOMPLISHED DETAIL VISUAL INSPECTIONS IN ACCORDANCE WITH AVO 2000513-0523-1 STEPS A.2 THRU 5. ALL DEFECTS NOTED ON LOG ITEMS. REMOVED FASTENERS PER AVO SDR CALA2021031200313Flap System · inoperativeFLAPS STUCK AT 5.1 ON CONFIG FOR LNDG FLAPS DISAGREE CHKLST CMPL T // UNEVENTFUL LDG UPDATED MAA CODE FIX USING VENDOR MAA SCREEN PLEASE CONTACT TOMC BEFORE COMMENCING ANY WORK. MAC RELATED WORK ORDER 000000003004540 AND PRTR MAC METER INITIATED FOR WITH VSDR CALA2019082601432Skin · crackedRIGHT HORIZONTAL STAB LOWER INSPAR SKIN CRACKED AT STA.138.70" AND 21" AFT OF FORWARD SPAR.(CRACK IS 1"LONG AND BLACK DOTS IN T HE RED CIRCLE MARK END OF CRCK)HFEC HAS BEEN DONE. CUT OUT SKIN.FABRICATED AND INSTALLED REPAIR DOUBLER PER SRM 55- 10-01,REPAIR 11.SDR CALA2019082301407Skin · crackedLEFT HORIZONTAL STAB LOWER INSPAR SKIN CRACKED AT STA.157.10 AND 13" FWD OF REAR SPAR.(CRACK IS 1"LONG AND BLACK DOTS IN THE RED CIRCLE MARK END OF CRACK)HFEC HAS BEEN DONE. CUTOUT SKIN.FABRICATED AND INSTALLED REPAIR DOUBLER PER SRM55-10 -01,REPAIR 11. INITIASDR CALA2018120102444Actuator · leakingPUSH CREW NOTIFIED US LARGE FUEL LEAK ENG 2 DURING START PERFORMED NR 2 ENGINE RUN, FOUND FUEL LEAK FROM RIGHT VSV. REMOVED AND REPLACED RIGHT VSV ACTUATOR ON NR 2 ENGINE PER AMM 75-31-01-4 00-802-F00. ACTUATOR LEAK CHECK GOOD. NO OTHER LEAKS NOTED. ROTABLE PSDR CALA2018012600330Lens · missingFORWARD COAT CLOSET AFT LOWER EMERGENCY LIGHT LENS IS MISSING. REPLACED THE LENS.SDR CALA2017121304420Battery · dischargedRT AFT OVERWING EMERGENCY LIGHT INOP. REMOVED AND REPLACED M1671 POWER SUPPLY IAW AMM 33-51-06-960-806. OPS CHECK GOOD IAW AMM 33-51-06-960-806.SDR CALA2017121304419Power Supply · inoperativeRT AFT OVERWING EMERGENCY LIGHT INOP. REMOVED AND REPLACED M1671 POWER SUPPLY IAW 33-51-06-960-806. OPS CHECK GOOD IAW AMM 33-51-06-960-806.SDR CALA2017111304049Unknown · odorBURNING PLASTIC ODOR EMANATING FROM THE AFT GALLEY COFFEEMAKERS, TURNED OFF AND ODOR WAS GONE. REMOVED AND INSPECTED BOTH COFFEEMAKERS. PERFORMED BREW CYCLE ON BOTH. NO UNUSUAL ODORS NOTED. COULD NOT DUPLICATE FAULT.SDR CALA2017101603648Lens · missingEMERGENCY LIGHT LENS MISSING. INSTALLED THE LENS.SDR CALA2017100803535Line · brokenSTRONG OIL ODOR THROUGH OUT COCKPIT AND CABIN, WITH APU BLEED ON. NORMAL WITH BLEED OFF. FOUND A BROKEN LINE ON THE PRIMARY FUEL MANIFOLD. R & R THE PRIMARY FUEL MANIFOLD LINE IAW AMM 49-31-16 OPS CHECKED GOOD.SDR CALA2017073002450Wire · disconnectedEMERGENCY LIGHT AT SEAT 32C INOP. RECONNECTED WIRE AT SEAT TO FLOOR CONNECTION. OPS CK GOOD. REF WDM 33-51-22 C/W IDT INSPECTION REF GMM 09-10-05.SDR CALA2017073002449Fuse · blownEMERGENCY LIGHTS AT SEAT AREA 25 & 28DEF BULLNOSE ARE INOP. RELAMPED NO HELP. REPLACED FUSE AND OPS CK GOOD. REF AMM 33-51-03-960-801 AND IPC 33-51-06-02 C/W IDT INSPECTION REF 09-10-05.SDR CALA2017070102071Bulb · burnedSMOKE COMING FROM FIRST OFFICER`S YOKE TRIP COUNTER, STRONG BURNING ODOR CONFIRMED. BULB IN MEMORY DEVICE WAS BURNED & CHARRED. R & R BOTH CAPTAIN`S AND FIRST OFFICER`S MEMORY DEVICES. FLIGHT DECK PLACED BACK TO ORIGINAL CONFIGURATION. INTALLATION TEST GOOSDR CALA2016092300680Light · inoperativeEMERGENCY LIGHT AT SEAT 11C BY STOW BIN. RELAMPED. OPS CHECKED GOOD, REF MM 33-51-00.SDR CALA2016080100485Skin · crackedFOUND CRACK AT LEFT HORIZONTAL STAB LOWER SKIN AT HSS 119 AND 36 INCHES AFT OF THE FRONT SPAR. INSTALLED CATEGORY B REPAIR DOUBLER IAW SRM 55-10-01 REPAIR 11.SDR CALA2016080100484Skin · crackedLEFT HORIZONTAL STAB LOWER SKIN, DURING C-SCAN FOUND A CRACK AT HSS 157. 10 INCHES INBD OF DRAIN HOLE. INSTALLED CATEGORY B REPAIR DOUBLER IAW SRM 55-10-01 REPAIR 11.SDR CALA2011101200657Warning System · false activationL/E FLAPS TRANSIT LIGHT ON WHEN FLAPS 30 SELECTED. LIGHT REMAINED ON AFTER MOVING FLAPS PER THE CHECKLIST. FSEU FAULT 27-81354 RECORDED.STALL SYS ONE SHAKE EACH YOKE ONLY 27-81-00-810-806 FIM TASK. RESET AUTOSLAT SYS C/B`S. PERFORMED TEST PER FIM AND ALL OSDR CALA2010091700428Detection Sys · malfunctionedWHEEL WELL FIRE LIGHT FROM 7000 FT TO LANDING SEEMS TO COME ON WITH SPEED BRAKE. TROUBLESHOT PER FIM. REMOVED AND REPLACED OVERHEAT DETECTION UNIT PER AMM 26-18-01- OPS CHECK AND BITE TEST GOOD. WORK PERFORMED ROTABLE PARTS CHANGE WAS INDICATED - TT 1446033