N771AN
Service difficulty reports · 232
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N771AN' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N771AN' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA201907159024Battery Pack · dischargedAIRCRAFT WAS GROUNDED: SEAT MOUNTED EMERGENCY LIGHTS FROM SEATS ROW 26 TO ROW 40 INOPERABLE ON BOTH SIDES. MAINTENANCE REPLACED POWER SUPPLY BATTERY PACK PER MM 33-51-06.SDR AALA201907159023Battery Pack · dischargedAIRCRAFT WAS GROUNDED: EMERGENCY AISLE CEILING LIGHTS ABOVE SEATS 26J AND 29J INOPERABLE. MAINTENANCE REPLACED POWER SUPPLY BATTERY PACK PER MM 33-51-06.SDR AALA201907119009Warning System · false activationAIRCRAFT WAS GROUNDED: REJECTED TAKEOFF AT LOW SPEED DUE TO MAIN LANDING GEAR STEERING WARNING LIGHT AND AUDIO. AIRCRAFT WAS LINED UP AND ROLLED FOR A BIT BEFORE POWER WAS APPLIED. ***SUPPLEMENTAL TO UPDATE SECTION 4 AND SECTION 5. MAINTENANCE ACCOMPLISHED HIGSDR AALA201907119008Not Reported · malfunctionedAIRCRAFT WAS GROUNDED: REJECTED TAKEOFF AT 60 KNOTS, MAIN GEAR STEERING ISSUE, REVERSE WAS DEPLOYED, IDLE ONLY. MAINTENANCE ACCOMPLISHED AMM 05-51-58 AND MCM CARD 05-96-31 AND PERFORMED SATISFACTORY OPERATIONAL CHECK.SDR AALA201904309001Transceiver · failedAIRCRAFT WAS GROUNDED: PILOT REPORTS FLIGHT RETURNED TO DFW ON ACCOUNT OF WEATHER RADAR FAILURE. MAINTENANCE REMOVED AND REPLACED THE RT WEATHER RADAR TRANSCEIVER IAW AMM 34-43-02-400-801. OPS CHECK GOOD.SDR AALA201812139027Window · out of adjustFIRST OFFICER`S WINDOW WAS DIFFICULT TO OPEN. AFTER INITIAL OPENING, THE WINDOW AND TRAVEL ARM POPPED DOWN A FEW INCHES. DIFFICULT TO CLOSE THE LAST FEW REVOLUTIONS DURING CLOSING. MAINTENANCE ADJUSTED WINDOW LINING IAW AMM 56-11-02-820-801, AND PERFORMED A SDR AALA20181129004Battery Pack · no testCABIN EMERGENCY LIGHT BATTERY PACK M33406 WOULD NOT CHARGE. REPLACED THE BATTERY PACK IAW AMM 33-51-06-960-802, AND PERFORMED SATISFACTORY OPERATIONAL CHECK IAW AMM 33-51-06-960-802.SDR AALA20181129003Battery Pack · no testCABIN EMERGENCY LIGHT BATTERY PACK M33400 WOULD NOT CHARGE. REPLACED BATTERY PACK IAW AMM 33-51-06-960-802, AND PERFORMED SATISFACTORY OPERATIONAL CHECK IAW AMM 33-51-06-960-802.SDR AALA20181129002Battery Pack · no testCABIN EMERGENCY LIGHT BATTERY PACK M33405 WOULD NOT CHARGE. REPLACED THE BATTERY PACK IAW AMM 33-51-06-960-802, AND PERFORMED SATISFACTORY OPERATIONAL CHECK IAW AMM 33-51-06-960-801.SDR AALA20181129001Battery Pack · no testCABIN EMERGENCY LIGHT BATTERY PACK WOULD NOT CHARGE. REPLACED THE BATTERY PACK IAW AMM 33-51-06-960-801 AND PERFORMED SATISFACTORY OPERATIONAL CHECK IAW AMM 33-51-06-960-801.SDR AALA201811276001Power Supply · inoperativePASSENGER B/C SEAT 1D, EMERGENCY LIGHT ALWAYS STAYS ON. REPLACED EMERGENCY POWER SUPPLY M33094 AND PERFORMED SUCCESSFUL TEST IAW AMM 33-51-00-720-801.SDR AALA201811298015Switch · failedTHE AFT CABIN L4 DOOR EPAS BATTERY PACK AMBER LIGHT DID NOT ILLUMINATE DURING TEST. REPLACED THE L4 DOOR OPEN SWITCH IAW AMM 52-11-28. OPS TESTED GOOD IAW AMM 52-11-20.SDR AALA201811276003Skin · corrodedLT FUSELAGE SKIN AT AFT VACUUM BLOWER EXHAUST CUTOUT WAS CORRODED AND BULGING BETWEEN BS 1958 AND 1979, STRINGERS 35L AND 36L. REPAIRED THE SKIN IAW SRM 53-70-01-2R-1, FIG 202.SDR AALA201811264001Seat Track · corrodedPASSENGER CABIN SEAT TRACK WAS CORRODED BETWEEN BS 1287 TO 1455, LBL 108. REPAIRED THE SEAT TRACK IAW SRM 53-00-52-2R, TABLE 201.SDR AALA201809129023Battery Pack · inoperativeWHILE PERFORMING WORK CARD 221N, DISCOVERED THAT THE R2 DOOR BATTERY PACK M33098 WAS INOPERATIVE. REPLACED THE BATTERY PACK IAW AMM 33-51-06, CHECKED OK FOR SERVICE.SDR AALA201801049007Warmer · odorAIRCRAFT WAS NOT GROUNDED: WARMER OVEN COMPARTMENT ONE SMOKES WHEN TURNED ON AND SMELLS LIKE BURNT PLASTIC. MAINTENANCE SCHEDULED TO REPLACE BUN WARMER AS NEEDED. ***SUPPLEMENTAL TO UPDATE SECTION 4. MAINTENANCE REPLACED BUN WARMER OF COMPARTMENT ONE (FORWARD SDR AALA20171028001Window · crackedAIRCRAFT WAS GROUNDED. EMERGENCY DECLARED. MXP-MIA FLIGHT DIVERTED TO YJT ACCOUNT R1 WINDOW CRACKED. OVERWEIGHT LANDING UNEVENTFUL. REMOVED AND REPLACED FIRST OFFICERS NR 1 WINDOW PER AMM 56-11-01. OPERATIONAL CHECK GOOD.SDR AALA201709259033Lens · detachedAIRCRAFT WAS NOT GROUNDED. EMERGENCY EXIT SIGN BY THE L2 DOOR HAS A DETACHED LENS COVER. REFITTED LENS COVER PER AMM 33-50-00. OPERATIONAL CHECK GOOD.SDR AALA201709069028Power Supply · inoperativeAIRCRAFT WAS NOT GROUNDED. SEAT MOUNTED EMERGENCY ESCAPE PATH LED LIGHT AT SEAT 4D IS INOPERATIVE. REMOVED AND REPLACED POWER SUPPLY PER ESO 21487. OPERATIONAL CHECK GOOD.SDR AALA20170518005Rib · corrodedAIRCRAFT WAS IN BASE MAINTENANCE. CORROSION ON RIGHT WING TRAILING EDGE OUTBOARD AILERON HINGE RIB NR 3 AT THE BONDING JUMPER ATTACH POINT AREA. REPAIRED IAW SRM 51-10-02 AND SRM 57-51-02-2R-3.SDR AALA20170519004Power Supply · no testR3 DOOR OVERHEAD EMERGENCY LIGHT POWER SUPPLY M33404 FAILED TO TEST. REMOVED AND REPLACED THE POWER SUPPLY IAW AMM 33-51-06. OPS CHECKED GOOD.SDR AALA20170519003Power Supply · no testL3 DOOR OVERHEAD EMERGENCY LIGHT POWER SUPPLY M33406 FAILED TO TEST. REMOVED AND REPLACED POWER SUPPLY IAW AMM 33-51-06. OPS CHECKED GOOD.SDR AALA20170511015Flashlight · brokenFLIGHT ATTENDANT FLASHLIGHT AT THE R4 DOOR CENTER PARTITION IS BROKEN. REMOVED AND REPLACED THE FLASHLIGHT ASSEMBLY IAW TASK CARD 222C. OPERATIONAL CHECKED GOOD.SDR AALA20170504002Seat Track · corrodedAIRCRAFT WAS IN BASE MAINTENANCE. ALUMINUM SEAT TRACK IS CORRODED BETWEEN FUSELAGE STATION 1445 AND 1557, RBL74. REPAIRED IAW SRM 53-00-52-2R-3, SRM 53-00-52-1A-1, AND EA 259262.SDR AALA20160810006Door · missingON ARRIVAL AT GATE, GROUND CREW REPORTED THE LEFT ECS LOW PRESSURE CONNECTION DOOR (195CL) WAS MISSING. AIRCRAFT GROUNDED. PRESUMED TO HAVE DEPARTED DURING FLIGHT. MAINTENANCE INSTALLED A NEW DOOR IAW AMM 52-48-04.SDR AALA20150629006Battery · dischargedM33096 & M33099 BATTERIES ARE DEAD. R & R M33099 BATTERY. TESTED & FOUND NORMAL IAW AMM 33-51-06. SEE ALSO AALA20150629001.SDR AALA20150629001Battery · dischargedM33096 & M33099 BATTERIES ARE DEAD. R & R M33096 BATTERY. TESTED & FOUND NORMAL IAW AMM 33-51-06. SEE ALSO AALA20150629006.SDR AALA20150627003Connector · brokenL2 DOOR EMER POWER ASSIST SYS RESERVOIR CONNECTOR FLANGE FOUND BROKEN. R & R CONNECTOR IAW SWPM 20-61-00. INSTALLATION TEST CARRIED OUT IAW AMM 52-11-20.SDR AALA20150625017Slat · delaminatedRIGHT WING SLAT NR 13 INBD REAR TE IS DELAMINATED. PERFORMED METAL HOT BOND REPAIR IAW SRM 57-43-02-2R PROCEDURE REPAIR 2 & SRM 51-70-10 REPAIR 4 FIG 202.SDR AALA20150625002Seat Track · corrodedSEAT TRACK AT LBL 74 IS CORRODED AT BS 1495. CORROSION REMOVED & BLEND OUT IAW SRM 51-10-02, SRM 53-00-51-1A ALLOWABLE DAMAGE 2 & SRM J53-00-52-2R REPAIR 3.SDR AALA20150624008Power Supply · inoperativeL1 DOOR EMER POWER SUPPLY M33093 INOPERATIVE. R & R M33093 POWER SUPPLY & PERFORMED OPERATIONAL TEST IAW AMM 33-51-06. SYS CHECKED NORMAL.SDR AALA20150624007Receptacle · detachedZONE C AFT FLOOR BOX RECEPTACLE D03203J DETACHED. RECEPTACLE D03203J REPLACED IAW SWPM 20-61-28. EMER LIGHTS TEST CARRIED OUT IAW AMM 33-51-00. SYS CHECKED NORMAL.SDR AALA20150623002Seat Track · corrodedSEAT TRACK AT LBL 108 IS CORRODED BETWEEN BS 1450 & 1494. CORROSION REMOVED & BLEND OUT IAW SRM 51-10-02 & SRM 53-00-52.SDR AALA20150623001Switch · deformedEMERGENCY LIGHT PUSHBUTTON SWITCH, S33025, ON ATTENDANT PANEL IS DEFORMED. R & R SWITCH IAW AMM 33-22-06. OPERATIONAL CHECKED NORMAL IAW AMM 33-51-00.SDR AALA20150622003Light · inoperativeCABIN SEAT 2G FWD PROXIMITY LIGHT INOPERATIVE. R & R PROXIMITY LIGHT ASSEMBLY. PERFORMED OPERATIONAL CHECK IAW AMM 33-51-05. SYS CHECKED NORMAL.SDR AALA20150622002Sign · broken1R DOOR AFT FLOOR PROXIMITY LIGHTING EXIT INDICATOR IS BROKEN. R & R FLOOR PROXIMITY LIGHTING EXIT SIGN. PERFORMED OPERATIONAL CHECK IAW AMM 33-51-01. SYS CHECKED NORMAL.SDR AALA20150622001Lens · brokenR3 DOOR FWD FLOOR PROXIMITY LIGHTING EXIT SIGN LENS FOUND BROKEN. R & R EXIT SIGN LENS. PERFORMED OPERATIONAL CHECK IAW AMM 33-51-01. SYS CHECKED NORMAL.SDR AALA20150620012Sign · brokenAFT GALLEY PARTITION WALL LT SIDE EXIT IDENTIFIER FLOODLIGHT IS BROKEN. R & R EXIT IDENTIFIER FLOODLIGHT. PERFORMED OPERATIONAL CHECK IAW AMM 33-51-01. SYS CHECKED NORMAL.SDR AALA20150620011Sign · damagedR4 DOOR RT FWD FLOOR PROXIMITY LIGHTING EXIT SIGN FOUND DAMAGED. R & R FLOOR PROXIMITY LIGHTING EXIT SIGN. PERFORMED OPERATIONAL CHECK IAW AMM 33-51-01. SYS CHECKED NORMAL.SDR AALA20150620010Sign · broken4L DOOR FWD FLOOR PROXIMITY LIGHTING EXIT INDICATOR BROKEN. R & R FLOOR PROXIMITY LIGHTING EXIT. PERFORMED OPERATIONAL CHECK IAW AMM 33-51-01. SYS CHECKED NORMAL.SDR AALA20150620008Power Supply · inoperative4R DOOR M33408 EMER POWER SUPPLY FAILED CAPACITY CONFIRMATION CHECK. R & R M33408 EMER POWER SUPPLY. PERFORMED OPERATIONAL CHECK IAW AMM 33-51-06. SYS CHECKED NORMAL.SDR AALA20150620007Light · brokenAFT GALLEY PARTITION WALL RT SIDE EXIT IDENTIFIER FLOODLIGHT IS BROKEN. R & R EXIT IDENTIFIER FLOODLIGHT. PERFORMED OPERATIONAL TEST CHECK IAW AMM 33-51-01. SYS CHECKED NORMAL.SDR AALA20150620005Light · brokenAFT GALLEY PARTITION WALL CTR SIDE EXIT IDENTIFIER FLOODLIGHT IS BROKEN. R & R EXIT IDENTIFIER FLOODLIGHT. PERFORMED OPERATIONAL CHECK IAW AMM 33-51-01. SYS CHECKED NORMAL.SDR AALA20150620006Lens · missingSEAT 34C PROXIMITY LIGHT LENS IS MISSING. INSTALLED LENS & PERFORMED OPERATIONAL CHECK IAW AMM 33-51-05. SYS CHECKED NORMAL.SDR AALA20150617014Panel · delaminatedVERTICAL STABILIZER PANEL 332 FL FOUND DELAMINATED. REPAIRED PANEL IAW SRM 51-70-05 REPAIR 2 & REF HX PROCESS CARD CONTROL SFQ NO.LPH510382-01.SDR AALA20150609013Truss · brokenRIGHT MOST OTBD SHEAR TRUSS BETWEEN FS 2150 & 2190 FOUND BROKEN. R & R SHEAR TRUSS IAW SRM 51-10-02. FASTENERS INSTALLED IAW SRM 51-40-02.SDR AALA20150609012Truss · brokenLEFT MOST OTBD SHEAR TRUSS BETWEEN FS 2129 & 2150 FOUND BROKEN. R & R SHEAR TRUSS IAW SRM 51-10-02. FASTENERS INSTALLED IAW SRM 51-40-02.SDR AALA20150610005Lens · looseL3 DOOR EMER EXIT SIGN LIGHT LENS FOUND LOOSE. SECURED LENS IAW AMM 33-51-04.SDR AALA20150610001Lens · looseL2 DOOR EMER EXIT SIGN LIGHT LENS FOUND LOOSE. SECURED LENS IAW AMM 33-51-04.SDR AALA20150405003Lamp · inoperativeROW 30 CTR CEILING EMERGENCY LIGHT INOPERATIVE. REPLACED THE LAMP IAW AMM 33-51-00. SYS CHECKED NORMAL.
Back to N771AN