N774SK
Service difficulty reports · 145
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N774SK' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N774SK' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWIA202162708None · corroded*CORROSION ON THE INTERCOSTAL BETWEEN STGR27 & STGR26R, FS349.00 €“ FS364.00 WEB AND LOWER FLANGE. (C-CHECK RO 11-20-2021) REMOVED AND INSTALLED NEW INTERCOSTAL BETWEEN STGR27 AND STGR 26R, FS349.00-FS364.00. REF CRJ-700 SRM 51-42-06-001-001-A01, SRM 51-4SDR SWIA202162707None · corroded*CORROSION ON THE INTERCOSTAL BETWEEN STGR27 & STGR26L, FS349.00 €“ FS364.00 WEB AND LOWER FLANGE. (C-CHECK RO 11-20-2021) REMOVED AND INSTALLED NEW INTERCOSTAL BETWEEN STGR27 AND STGR 26L, FS349.00-FS364.00. REF CRJ700 SRM 51-42-06-001-001-A01, CRJ700 SRSDR SWIA202162735None · corroded* LH SIDE SEAT RAIL GOUGED AT APROX. FS.437.00 (MARKED). (C-CHECK RO 11-20-2021) REMOVED AND INSTALLED NEW L/H SIDE SEAT TRACK AT APPROX. FS437 CRJ-700 AMM 53-00-49-400-801-A17SDR SWIA202162734None · corroded* LH SIDE SEAT RAIL CORRODED AT APROX. FS.501.00 (MARKED). (C-CHECK RO 11-20-2021) REPLACED LH SIDE SEAT RAIL CORRODED AT APROX. FS.501.00 T AND HARDWARE AND INSTALLED TRACK REF CRJ700 AMM 53-00-49-400-801 -A17 TORQUE USED TUC8612 DUE.31-OCT-21SDR SWIA202162706None · corroded*CORROSION ON FRAME FS 645.00 BETWEEN STGR 26R €“ 26L (C-CHECK RO 11-20-2021) REMOVED CORROSION ON FRAME AT FS645.00 BETWEEN STGR 26R-26L. REF. CRJ700 SRM 51-21-06-001-001-A01. EVALUATED AS OUT-OF-LIMITS. RECIEVED AND COMPLIED WITH ALL STEPS OF MHIRJ REO SDR SWIA202162705None · corroded*CORROSION ON FLOOR SUPPORT CROSSBEAM FS 1051.00 TOP SURFACE BETWEEN RBL 27 €“ 36 (C-CHECK RO 11-20-2021) COMPLIED WITH ALL STEPS IN REPAIR ON FLOOR SUPPORT STRUCTURE AT FS1051.3, OUTBD OF RBL-27. CONDITION IS STRUCTURALLY ACCEPTABLE. REF REO 670-53-61-1SDR SWIA202162733None · corroded* CABIN FLOOR SEAT TRACK AT RBL9 CORRODED IN MULTIPLE SPOTS BETWEEN APPROXIMATELY FS.830.00 TO FS.982.00 (MARKED). (C-CHECK RO 11-20-2021) REPLACED CORRODED CABIN FLOOR SEAT TRACK AT RBL9, APPROXIMATELY FS.830.00 TO FS.982.00 WITH NEW TRACK AND NEW HARDWARSDR SWIA202162732None · corroded* CABIN FLOOR SEAT TRACK AT LBL9 CORRODED IN MULTIPLE SPOTS BETWEEN APPROXIMATELY FS.830.00 TO FS.989.00 (MARKED). (C-CHECK RO 11-20-2021) REPLACED CORRODED CABIN FLOOR SEAT TRACK AT LBL9, APPROXIMATELY FS.830.00 TO FS.989.00 WITH NEW TRACK AND NEW HARDWARSDR SWIA202162731None · corroded* CABIN FLOOR SEAT TRACK AT RBL27 CORRODED IN MULTIPLE SPOTS BETWEEN APPROXIMATELY FS.982.00 TO FS.1005.00 (MARKED). (C-CHECK RO 11-20-2021) REPLACED WITH NEW TRACK AND NEW HARDWARE REF CRJ700 AMM 53-00-49-400-802-A06. / TOOL # TUC9564 CAL: 16-NOV-20 DUE:SDR SWIA202162730None · corroded* CABIN FLOOR SEAT TRACK AT RBL9 CORRODED IN MULTIPLE SPOTS BETWEEN APPROXIMATELY FS.982.00 TO FS.1005.00 (MARKED). (C-CHECK RO 11-20-2021) REPLACED WITH NEW TRACK AND NEW HARDWARE REF CRJ700 AMM 53-00-49-400-802-A06. / TOOL # TUC9564 CAL: 16-NOV-20 DUE: SDR SWIA202162729None · corroded* CABIN FLOOR SEAT TRACK AT LBL9 CORRODED IN MULTIPLE SPOTS BETWEEN APPROXIMATELY FS.989.00 TO FS.1005.00 (MARKED). (C-CHECK RO 11-20-2021) REPLACED WITH NEW TRACK AND NEW HARDWARE REF CRJ700 AMM 53-00-49-400-802-A06. / TOOL # TUC9564 CAL: 16-NOV-20 DUE: SDR SWIA202162728None · cracked* AFT CARGO 4EA.DOOR GUIDE RAIL RUBBER STOPS CRACKED AT THE FWD UPPER AND LOWER AND THE AFT UPPER AND LOWER POSITIONS. (C-CHECK RO 11-20-2021) REMOVED 2EA AFT BAGGAGE BAY DOOR UPPER STOPS PER CRJ 700AMM 52-31-23-000-801-A02 AND INSTALLED 2EA NEW UPPER STOPSDR SWIA202162704None · corroded* AFT CARGO DOOR LOWER SILL CORRODED IN MULTIPLE SPOTS (MARKED). (C-CHECK RO 11-20-2021) COMPLIED WITH PERMANENT REPAIR IN REPLACEMENT OF AFT CARGO DOOR LOWER SILL. REF CRJ-700 SRM 51-42-21-001-001-A01, SRM 51-42-06-001-001-A01, SRM 51-42-13-001-001-A01, ASDR SWIA202162703None · corrodedL/H SLAT TRACK 3-3 HAS EVIDENCE OF CORROSION/FRETTING AND DEGRADED PROTECTIVE COATING (C-CHECK RO 11-20-2021) BLENDED CORROSION ON THE LH SLAT TRACK 3-3 "WITHIN LIMITS" REF MHI REO 670-57-42-1206 REV-- DATED 2021-10-15. RESTORED ACCESS. OP CHECKS & GAP CSDR SWIA202162702None · corrodedL/H SLAT TRACK 3-2 HAS EVIDENCE OF CORROSION/FRETTING AND DEGRADED PROTECTIVE COATING (C-CHECK RO 11-20-2021) BLENDED CORROSION ON THE LH SLAT TRACK 3-2 "WITHIN LIMITS" REF MHI REO 670-57-42-1212 REV-- DATED 2021-10-15, ALL STEPS COMPLIED WITH. RESTORED ASDR SWIA202162701None · corrodedL/H SLAT TRACK 3-1 HAS EVIDENCE OF CORROSION/FRETTING AND DEGRADED PROTECTIVE COATING (C-CHECK RO 11-20-2021) BLENDED CORROSION ON THE LH SLAT TRACK 3-1 "WITHIN LIMITS" REF MHI REO 670-57-42-1211 REV-- DATED 2021-10-15. RESTORED ACCESS. OP CHECKS & GAP CSDR SWIA202162700None · corrodedL/H SLAT TRACK 2-3 HAS EVIDENCE OF CORROSION/FRETTING AND DEGRADED PROTECTIVE COATING (C-CHECK RO 11-20-2021) BLENDED CORROSION ON THE LH SLAT TRACK 2-3 "WITHIN LIMITS" REF MHI REO 670-57-42-1210 REV-- DATED 2021-10-14. RESTORED ACCESS. OP CHECKS & GAP CSDR SWIA202162699None · corrodedL/H SLAT TRACK 2-2 HAS EVIDENCE OF CORROSION/FRETTING AND DEGRADED PROTECTIVE COATING (C-CHECK RO 11-20-2021) BLENDED CORROSION ON THE LH SLAT TRACK 2-2 "WITHIN LIMITS" REF MHI REO 670-57-42-1240 REV-- DATED 2021-10-27. RESTORED ACCESS. OP CHECKS & GAP CSDR SWIA202162698None · corrodedL/H SLAT TRACK 2-1 HAS EVIDENCE OF CORROSION/FRETTING AND DEGRADED PROTECTIVE COATING (C-CHECK RO 11-20-2021) BLENDED CORROSION ON THE LH SLAT TRACK 2-1 "WITHIN LIMITS" REF MHI REO 670-57-42-1249 REV-- DATED 2021-11-01, ALL STEPS COMPLIED WITH. RESTORED ASDR SWIA202162697None · corrodedL/H SLAT TRACK 1-3 HAS EVIDENCE OF CORROSION/FRETTING AND DEGRADED PROTECTIVE COATING (C-CHECK RO 11-20-2021) BLENDED CORROSION ON THE LH SLAT TRACK 1-3 "WITHIN LIMITS" REF MHI REO 670-57-42-1207 REV-- DATED 2021-10-15, ALL STEPS COMPLIED WITH. RESTORED ASDR SWIA202162696None · corrodedL/H SLAT TRACK 1-2 HAS EVIDENCE OF CORROSION/FRETTING AND DEGRADED PROTECTIVE COATING (C-CHECK RO 11-20-2021) BLENDED CORROSION ON THE LH SLAT TRACK 1-2 "WITHIN LIMITS" REF MHI REO 670-57-42-1221 REV-- DATED 2021-10-18, ALL STEPS COMPLIED WITH. RESTORED ASDR SWIA202162695None · corrodedL/H SLAT TRACK 1-1 HAS EVIDENCE OF CORROSION/FRETTING AND DEGRADED PROTECTIVE COATING (C-CHECK RO 11-20-2021) BLENDED CORROSION ON THE LH SLAT TRACK 1-1 "WITHIN LIMITS" REF MHI REO 670-57-42-1209 REV-- DATED 2021-10-14, ALL STEPS COMPLIED WITH. RESTORED ASDR SWIA202162694None · corrodedR/H SLAT TRACK 3-3 HAS EVIDENCE OF CORROSION/FRETTING AND DEGRADED PROTECTIVE COATING (C-CHECK RO 11-20-2021) BLENDED CORROSION ON THE RH SLAT TRACK 3-3 "WITHIN LIMITS" REF MHI REO 670-57-42-1223 REV-- DATED 2021-10-18, ALL STEPS COMPLIED WITH. RESTORED ASDR SWIA202162693None · corrodedR/H SLAT TRACK 3-2 HAS EVIDENCE OF CORROSION/FRETTING AND DEGRADED PROTECTIVE COATING (C-CHECK RO 11-20-2021) BLENDED CORROSION ON THE RH SLAT TRACK 3-2 "WITHIN LIMITS" REF MHI REO 670-57-42-1218 REV-- DATED 2021-10-15. RESTORED ACCESS. OP CHECKS & GAP CSDR SWIA202162692None · corrodedR/H SLAT TRACK 3-1 HAS EVIDENCE OF CORROSION/FRETTING AND DEGRADED PROTECTIVE COATING (C-CHECK RO 11-20-2021) BLENDED CORROSION ON THE RH SLAT TRACK 3-1 "WITHIN LIMITS" REF MHI REO 670-57-42-1227 REV-- DATED 2021-10-20, ALL STEPS COMPLIED WITH. RESTORED ASDR SWIA202162691None · corrodedR/H SLAT TRACK 2-2 HAS EVIDENCE OF CORROSION/FRETTING AND DEGRADED PROTECTIVE COATING (C-CHECK RO 11-20-2021) BLENDED CORROSION ON THE RH SLAT TRACK 2-2 "WITHIN LIMITS" REF MHI REO 670-57-42-1216 REV-- DATED 2021-10-17, ALL STEPS COMPLIED WITH. RESTORED ASDR SWIA202162690None · corrodedR/H SLAT TRACK 2-1 HAS EVIDENCE OF CORROSION/FRETTING AND DEGRADED PROTECTIVE COATING (C-CHECK RO 11-20-2021) BLENDED CORROSION ON THE RH SLAT TRACK 2-1 "WITHIN LIMITS" REF MHI REO 670-57-42-1215 REV-- DATED 2021-10-15, ALL STEPS COMPLIED WITH. RESTORED ASDR SWIA202162689None · corrodedR/H SLAT TRACK 1-3 HAS EVIDENCE OF CORROSION/FRETTING AND DEGRADED PROTECTIVE COATING (C-CHECK RO 11-20-2021) BLENDED CORROSION ON THE RH SLAT TRACK 1-3 "WITHIN LIMITS" REF MHI REO 670-57-42-1213 REV-- DATED 2021-10-20, ALL STEPS COMPLIED WITH. RESTORED ASDR SWIA202162688None · corrodedR/H SLAT TRACK 1-2 HAS EVIDENCE OF CORROSION/FRETTING AND DEGRADED PROTECTIVE COATING (C-CHECK RO 11-20-2021) BLENDED CORROSION ON THE RH SLAT TRACK 1-2 "WITHIN LIMITS" REF MHI REO 670-57-42-1214 REV-- DATED 2021-10-18, ALL STEPS COMPLIED WITH. RESTORED ASDR SWIA202162687None · corrodedR/H SLAT TRACK 1-1 HAS EVIDENCE OF CORROSION/FRETTING AND DEGRADED PROTECTIVE COATING (C-CHECK RO 11-20-2021) BLENDED CORROSION ON THE RH SLAT TRACK 1-1 "WITHIN LIMITS" REF MHI REO 670-57-42-1208 REV-- DATED 2021-10-14, ALL STEPS COMPLIED WITH. RESTORED ASDR SWIA202162751None · corrodedO/B FLAP HINGE BOX SUPPORT FITTING ON L/H O/B FLAP HAS EVIDENCE OF CORRODED HARDWARE (C-CHECK RO 11-20-2021) REMOVED 6EA CORRODED HARDWARE REF CRJ 700 AMM 57-54-02-000-808-A01 STEPS 4. A. (2) D-G AND (3) A-B, AND INSTALLED NEW SERVICABLE HARDWARE 6EA BOLTSSDR SWIA202162748None · damagedREMOVE AND REPLACE BUSHINGS AND HARDWARE ON LH AILERON WING AFT SPAR PER AMM (C-CHECK RO 11-20-2021) REMOVED OLD AND INSTALLED 8EA NEW BUSHINGS FOR LH AILERON AT WING AFT SPAR FITTINGS - REF CRJ700 AMM 20-31-00-000-801 A01 AND CRJ700 AMM 20-31-00-400-802 ASDR SWIA202162747None · damagedREMOVE AND REPLACE BUSHINGS AND HARDWARE ON RH AILERON WING AFT SPAR PER AMM (C-CHECK RO 11-20-2021) REMOVED OLD AND INSTALLED 8EA NEW BUSHINGS FOR RH AILERON AT WING AFT SPAR FITTINGS - REF CRJ700 AMM 20-31-00-000-801 A01 AND CRJ700 AMM 20-31-00-400-802 ASDR SWIA2019121847022Angle · crackedR/H FWD AND R/H AFT UPLOCK ANGLES ARE CRACKED (C-CHECK) RO 12/14/2019 REMOVED AND REPLACED R/H FWD AND R/H AFT UPLOCK ANGLES IAW CRJ 700 SRM.SDR SWIA2019121847023Bulkhead Web · crackedFOUND RH F.S. 736 DIAPHRAGM TO BE CRACKED FROM THE TOP HOLE ON THE I/B FACE. (C-CHECK) RO 12/14/2019 REMOVED AND INSTALLED SERVICEABLE DIAPHRAGM AT R.H. F.F. 736 IAW CRJ700 SRM AND DRG. / NO WEIGHT CHANGE, PART FOR PART REPLACEMENT.SDR SWIA2019121847025Skin · chafedWHILE ACCESSING FOR PRESSURE FLOOR MOD SB 670-53-036 FOUND SKIN CHAFFED UNDER PANEL 196DL AT STR27 BETWEEN FS.977 - 985.00. (C-CHECK) RO 12/14/2019 REPAIRED SKIN CHAFE BY BLENDING OUT DAMAGED AREA FOR NDT THICKNESS CHECK,FOUND DAMAGED ARES OUT OF LIMITS PER RSDR SWIA201947024Structure · not reportedCOMPLY WITH: SB - FUSELAGE - CENTER FUSELAGE, FS669.40 TO FS855.40 - REPLACEMENT OF THE BEAMS AF LBL36 AND RBL36, AND THE FLOOR ASSEMBLY BETWEEN FS693.00 AND FS847.00 WITH BEAMS INSTALLED AT BL0, LBL9, LBL18, LBL27, RBL9, RBL18 AND RBL27 REV D PART(S) 0 (C-CSDR SWIA2019121847021Structure · unknownCOMPLY WITH: SB - FUSELAGE - CENTER FUSELAGE, PRIMARY STRUCTURE FS280.00 TO FS295.00 - INSPECTION AND REINFORCEMENT OF LINTEL STRINGER 3 OF THE MAIN PASSENGER DOOR REV C PART(S) A, B (C-CHECK) RO 12/14/2019 SERVICE BULLETIN - FUSELAGE - CENTER FUSELAGE, PRSDR SWIA2019050645828Pin · defectiveENGINE 1 N1 VIBRATION. AT CRUISE, MOVED THROTTLES FROM CLIMB TO CRUISE RANGE. N1 VIBRATION INCREASED TO 2.1 WITH NOTICEABLE VIBRATION CHANGE AND SOUND. CONTINUED TO DECREASE POWER UNTIL VIBRATION IN NORMAL RANGE. ENGINE VIBRATION WOULD THEN INCREASE AGAIN INTOSDR SWIA2018091845082Cleat · corrodedATTACHMENT CLEAT AT FS 313.56 FRAME REQUIRES REPLACEMENT DUE TO CORROSION BEYOND REPAIR. (C-CHECK) RO: 09/15/2018. REMOVED AND REPLACED CLEAT FS 313.56 WITH NEW IAW SRM.SDR SWIA2018091845081Frame · corrodedFRAME AT FS313.56 BETWEEN DD4 AND DD5 REQUIRES REPLACEMENT DUE TO CORROSION. (C-CHECK) RO: 09/15/2018. REMOVED AND REPLACED FRAME AT FS 313.56 BETWEEN DD4 AND DD5 IAW SRM. LEAK CHECK GOOD.SDR SWIA2017092243787Door Sill · corrodedSERVICE DOOR SILL HAS SEVERAL AREAS OF CORROSION. REMOVED AND REPLACED THE DOOR SILL IAW SRM.SDR SWIA2017092243786Floorbeam · corrodedBS 280 FLOORBEAM CAP HAS EVIDENCE OF CORROSION BETWEEN LBL 11 AND RBL 11. INSTALLED REPLACEMENT CAP IAW SRM.SDR SWIA201438826Light · inoperativeLEFT AFT EXTERIOR EMERGENCY LIGHT IS INOPERATIVE. R & R LT AFT EXTERIOR EMERGENCY LIGHT IAW AMM.SDR SWIA201438593Skin · gougedRIGHT OTBD SLAT IS GOUGED ON THE T/E APPROXIMATELY 38.25" FROM THE END OF THE SLAT. PERFORMED PERMANENT REPAIR OF RT OTBD SLAT T/E APPROXIMATELY 38.25" FROM THE END OF THE SLAT IAW REO. 2014NM060066SDR SWIA201437650Lamp · inoperativeFWD CABIN EMERGENCY OVERHEAD LIGHT DOES NOT ILLUMINATE. REPLACED THE LAMP.SDR SWIA201436842Floor Panel · chafedFLOOR PANEL 684AB WORN BEYOND LIMITS. C-CHECK, REPLACED FLOOR PANEL IAW SRM.SDR SWIA201436845Skin · chafedLT FLAP INBD PANEL 584GB CHAFED. C-CHECK, REPLACED FLAP PANEL IAW SRM.SDR SWIA201436841Floorbeam · corrodedRT FLOORBEAM CORRODED BS 280. C-CHECK, REMOVED CORROSION IAW REO.SDR SWIA201436846Floor Panel · crackedRIGHT TRU BAY FLOOR CRACKED AT ADG STOW HAND PUMP. C-CHECK, REPAIRED FLOOR PANEL IAW REO.
Back to N774SK