N775AN
Service difficulty reports · 222
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N775AN' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N775AN' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA202106039006Light · damagedAIRCRAFT WAS NOT GROUNDED: ESCAPE PATH LIGHTING NEAR G3 GALLEY CLOSET IS DAMAGED ACROSS FROM 1L JUMPSEAT. REPLACED FLOOR PROXIMITY LIGHT ASSEMBLY NEAR G3 GALLEY CLOSET PER AMM 33-51-05.SDR AALA2020080319009Battery Pack · inoperativeAIRCRAFT WAS GROUNDED, MDCR HAS INOPERATIVE EMERGENCY LIGHTS AT THE L3 DOOR INTERIOR LIGHT ABOVE THE DOOR AND EXTERIOR LIGHTS FIRST 3 ON THE LEFT HAND SIDE AND RIGHT HAND SIDE. REMOVED AND REPLACED POWER SUPPLY BATTERY PACK M33400 IAW AMM 33-51-06-960-803. ESDR AALA202007309002Battery Pack · no testAIRCRAFT WAS GROUNDED, L2 DOOR EMERGENCY LIGHT BATTERY PACK M33096 FAILED TO TEST. REPLACED THE BATTERY PACK IAW AMM 33-51-06.SDR AALA202007309001Power Supply · inoperativeAIRCRAFT WAS GROUNDED (SHORT TERM STORAGE): L3 DOOR EMERGENCY LIGHT POWER SUPPLY UNIT M33400 FAILED TEST. REPLACED DOOR 3L EMERGENCY LIGHT POWER SUPPLY ASSEMBLY PER 33-51-06.SDR AALA202001159049Snubber · leakingAIRCRAFT WAS GROUNDED: SNUBBER LEAKING FLUID. MAINTENANCE REPLACED SNUBBER PER STANDARD PRACTICES.SDR AALA201911289003Battery Pack · faultyAIRCRAFT NOT GROUNDED: EMER LT INOP BY CREW ATT REST MODULE. LH AND RH FWD SECTION. REPLACED BATT PWR PACK M33400 AND EMER LIGHT LH AND RH SECTON CREW REST MODULE CKS OK IAW AMM 33-51-06.SDR AALA201909099032Fuse · damagedAIRCRAFT NOT GROUNDED: DURING ACCOMP. OF PS2 CK FOUND EMER LIGHT OF MDCR FLOOR PROX LIGHT INOPERATIVE. PERFORMED T/S IAW WDM 33-51-35. FOUND POWER SUPPLY M38400 FUSE DAMAGED. REPLACED POWER SUPPLY FUSE IAW AMM 33-51-06.SDR AALA20190515001Battery · dischargedAIRCRAFT WAS NOT GROUNDED: 2R DOOR EMERGENCY POWER ASSIST SYSTEM BATTERY FOUND FLAT. MAINTENANCE REPLACED BATTERY PER AMM 52-11-20.SDR AALA201905139018Battery · dischargedAIRCRAFT WAS NOT GROUNDED: 2R DOOR EMERGENCY POWER ASSIST SYSTEM BATTERY FLAT. MAINTENANCE REPLACED BATTERY PER AMM 52-11-20.SDR AALA2019042329004Fan · failedAIRCRAFT WAS NOT GROUNDED: RATTLING NOISE ABOVE ROW 26, ACCOMPANIED BY RECIRCULATION FAN STATUS MESSAGE AND ELECTRICAL SMELL. TURNED UPPER RECIRCULATION FANS OFF AND BURNING SMELL DISAPATED AND RATTLING NOISE STOPPED. ***SUPPLEMENTAL INFORMATION: MAINTENANCE ISDR AALA201902269002Smoke Detector · malfunctionedPILOT REPORTED THAT A SMOKE DETECTOR AURAL ALERT IN LAVATORY 3F-1L WAS INDICATED. NO SMOKE FOUND. THE LAV 3F-1L SMOKE DETECTOR WAS REPLACED.SDR AALA201902109002Smoke Detector · intermittentAIRCRAFT WAS NOT GROUNDED: LAVATORY 3LF SMOKE ALARM INTERMITTENT WITH NO SMOKE PRESENT. MAINTENANCE RESET SMOKE DETECTOR PER AMM 26-13-01 AND PERFORMED SATISFACTORY OPERATIONAL CHECK.SDR AALA201812271003Battery Pack · inoperativeEMERGENCY LIGHT BATTERY IN THE MID CABIN, ABOVE THE L3 DOOR WAS INOPERATIVE. REPLACED THE POWER SUPPLY BATTERY PACK IAW AMM 33-51-06-960-802. OPS CHECKED GOOD.SDR AALA201812241004Charger · inoperativeEMERGENCY BATTERY CHARGER M33093 WAS INOPERATIVE ABOVE THE L1 DOOR. REPLACED THE BATTERY CHARGER IAW AMM 33-51-06-960-803. OPS CHECKED OK.SDR AALA201812270005Battery · inoperativeBATTERY ABOVE THE R4 DOOR DOES NOT HOLD A CHARGE. REPLACED THE POWER SUPPLIES M33408 AND M33409. OPS CHECKED GOOD IAW MM 33-51-06.SDR AALA20181220001Floorbeam · crackedAFT CARGO FLOORBEAM, BS 1874 WAS CRACKED ON THE UPPER FLANGE. REMOVED AND REPLACED THE CARGO FLOORBEAM IAW SRM 51-40-02, AND RD 51-00-05-1.SDR AALA20181215002Light · failedAIRCRAFT WAS IN BASE MAINTENANCE. EMERGENCY LIGHT AT GALLEY 3 LEFT SIDE CORNER FAILED TEST. REPLACED EMERGENCY LIGHT ASSY PER ESO 20632. OPERATIONS CHECK ACCOMPLISHED ON WORK CARD 2341/72C20033012.SDR AALA201811149006Battery Pack · inoperativeFLOOR EMERGENCY LIGHT WILL NOT TURN ON. REPLACED THE BATTERY PACK IAW AMM 33-51-06-960-802.SDR AALA201804189034Lens · missingSEAT 26D EMERGENCY LIGHT LENS MISSING. MAINTENANCE INSTALLED THE LENS IAW MM 33-50-00 AND PERFORMED A SATISFACTORY OPS CHECK.SDR AALA201803129042Fan · faultyAIRCRAFT WAS NOT GROUNDED: RECIRCULATING FAN STATUS MESSAGE ON ENGINE INDICATION AND CREW ALERTING SYSTEM. DUE TO INFLIGHT RECIRCULATING FAN FAILURE MAINTENANCE MESSAGE 21-24400 AND ODOR THAT SHORTLY WENT AWAY, THE FLIGHT CREW ELECTED TO CONTINUE TO HNL. MAINTSDR AALA201712079039Cover · detachedAIRCRAFT WAS NOT GROUNDED. SMALL WHITE EXIT SIGN COVER CAME OFF NEAR 2R DOOR. REPLACED EMERGENCY LIGHT ASSEMBLY PER AMM 33-51-01. OPERATIONAL CHECKED NORMAL.SDR AALA20170220007Light · brokenAIRCRAFT IN BASE MAINTENANCE. EMERGENCY EXIT FLOOR PROXIMITY LIGHT ASSEMBLY RIGHT FORWARD G3 GALLEY IS BROKEN. REMOVED AND REPLACED LIGHT ASSEMBLY IAW AMM 33-51-05. OPERATIONAL CHECK GOOD.SDR AALA20170220001Connector · damagedAIRCRAFT IN BASE MAINTENANCE. SEAT MOUNTED ESCAPE PATH LIGHTS MIDDLE SECTION SEATS 27 THROUGH 40 ARE INOPERATIVE. REMOVED AND REPLACED ELECTRICAL PLUG AT SEAT 27 CENTER IAW WDM 33-51-58 AND SWPM 20-61-28. OPERATIONAL CHECK GOOD.SDR AALA20170216005Power Supply · failedAIRCRAFT IN BASE MAINTENANCE. EMERGENCY EXIT FLOOR PROXIMITY LIGHTS AFT RIGHT FAILED TEST. REMOVED AND REPLACED POWER SUPPLY M33401 AT R3 DOOR IAW AMM 33-51-06. OPERATIONAL CHECK GOOD.SDR AALA20170216004Power Supply · failedAIRCRAFT IN BASE MAINTENANCE. CEILING EMERGENCY EXIT LIGHT MID ZONE LEFT AISLE FAILED TEST. REMOVED AND REPLACED POWER SUPPLY M33099 AT L2 DOOR IAW AMM 33-51-06. OPERATIONAL CHECK GOOD.SDR AALA20170216003Power Supply · failedAIRCRAFT IN BASE MAINTENANCE. CEILING EMERGENCY EXIT LIGHT MID ZONE RIGHT AISLE FAILED TEST. REMOVED AND REPLACED POWER SUPPLY M33406 AT L3 DOOR IAW AMM 33-51-06. OPERATIONAL CHECK GOOD.SDR AALA20170216002Power Supply · failedAIRCRAFT IN BASE MAINTENANCE. EMERGENCY EXIT SIGN AFT LEFT FAILED TEST. REMOVED AND REPLACED POWER SUPPLY M33407 AT L4 DOOR IAW AMM 33-51-06. OPERATIONAL CHECK GOOD.SDR AALA20170216006Lens · looseAIRCRAFT IN BASE MAINTENANCE. R1 DOOR SLIDE LIGHT LENS ASSEMBLY IS LOOSE. TIGHTENED LENS ASSEMBLY IAW AMM 33-51-04. OPERATIONAL CHECK GOOD.SDR AALA20170212015Indicator · damagedAIRCRAFT IN BASE MAINTENANCE. EMERGENCY EXIT FLOOR PROXIMITY INDICATOR IS DAMAGED. REMOVED AND REPLACED INDICATOR. OPERATIONAL CHECK GOOD.SDR AALA20170124001Floor Panel · delaminatedAIRCRAFT WAS IN BASE MAINTENANCE. CABIN FLOOR PANEL BETWEEN FUSELAGE STATION 910 AND 1030 AND BETWEEN LBL 11 AND RBL 11 IS DELAMINATED. REMOVED AND REPLACED FLOOR PANEL AARD 51-00-05-1 REPAIR 1, AMM 53-01-01 AND DRAWING 151W8316-44.SDR AALA20161006004Fan · odorDURING CRUISE, FLIGHT ATTENDANTS REPORTED A BURNING ODOR IN THE CABIN. ODOR ISOLATED TO RIGHT LOWER RECIRCULATION FAN. REMOVED AND REPLACED THE RECIRCULATION FAN IAW AMM 21-25-07.SDR AALA20150714013Sign · crackedL3 DOOR AFT EXIT SIGN FOUND CRACKED. R & R EXIT SIGN. PERFORMED OPERATIONAL TEST IAW AMM 33-51-01. SYS CHECKED NORMAL.SDR AALA20150714002Power Supply · inoperativeSEAT 42B EMER LIGHT INOPERATIVE. R & R POWER SUPPLY. PERFORMED OPERATIONAL TEST IAW AMM 35-51-06. SYS CHECKED NORMAL.SDR AALA20150712002Slat · delaminatedRIGHT WING NR 12 SLAT OTBD AREA FOUND DELAMINATED. REPAIRED IAW SRM 57-43-02-2R PROCEDURE 2 REPAIR 2 & SRM 51-20-10 REPAIR 4 FIGURE 202.SDR AALA20150711002Light · inoperativeEMERGENCY LIGHT AT SEAT 20C FOUND INOPERATIVE. R & R SEAT 20C EMER LIGHT. PERFORMED OPERATIONAL TEST IAW AMM 33-51-05. SYS CHECKED NORMAL.SDR AALA20150713005Lens · missingGALLEY 3R HAS TWO EACH EMER LIGHT LENS MISSING. INSTALLED LENS & PERFORMED OPERATIONAL CHECK IAW AMM 33-51-05. SYSTEM CHECKED NORMAL. SEE ALSO AALA20150711001.SDR AALA20150713002Skin · damagedMAIN DECK 2R DOOR LOWER AFT CORNER OUTER SKIN DAMAGE. REPAIR ACCOMPLISHED IAW SRM 52-10-01 REPAIR 8 FIG 202. NO REPORT DAMAGE OUTSIDE INFLUENCE.SDR AALA20150711001Lens · missingGALLEY 3R HAS TWO EACH EMER LIGHT LENS MISSING. INSTALLED LENS & PERFORMED OPERATIONAL CHECK IAW AMM 33-51-05. SYS CHECKED NORMAL. SEE ALSO AALA20150713005.SDR AALA20150710010Power Supply · inoperativeR2 DOOR EMER LIGHT BATTERY M33098 FAILED OPERATION TEST. R & R POWER SUPPLY ASSEMBLY. PERFORMED OPERATIONAL TEST IAW AMM 33-51-06. SYS CHECKED NORMAL.SDR AALA20150710009Sign · crackedL3 DOOR FWD EXIT SIGN FOUND CRACKED. R & R EXIT SIGN. PERFORMED OPERATIONAL TEST IAW AMM 33-51-01. SYS CHECKED NORMAL.SDR AALA20150710008Power Supply · inoperativeR1 DOOR EMER LIGHT BATTERY M33094 FAILED OPERATION TEST. R & R POWER SUPPLY ASSEMBLY. PERFORMED OPERATIONAL TEST IAW AMM 33-51-06. SYS CHECKED NORMAL.SDR AALA20150710007Power Supply · inoperativeR2 DOOR EMER LIGHT BATTERY M33097 FAILED OPERATION TEST. R & R POWER SUPPLY ASSEMBLY. PERFORMED OPERATIONAL TEST IAW AMM 33-51-06. SYS CHECKED NORMAL.SDR AALA20150713001Slat · delaminatedRIGHT WING NR 13 SLAT INBD AREA FOUND DELAMINATED. REPAIRED IAW SRM 57-43-02-2R PROCEDURE 2 REPAIR 2 & SRM 51-70-10 REPAIR 4 FIGURE 202.SDR AALA20150707008Switch · faultyL3 DOOR EMER POWER ASSIST SYS BATTERY FAILED OPERATIONAL TEST, AMBER SQUIB CONTINUITY TEST LIGHT WAS NOT ILLUMINATED. CHECKED WIRING & FOUND DOOR SWITCH S52125 OPEN. R & R SWITCH. PERFORMED OPERATIONAL TEST IAW AMM 52-11-18 & 52-11-20. SYS CHECKED NORMAL.SDR AALA20150707007Switch · faultyR4 DOOR EMER POWER ASSIST SYS BATTERY FAILED OPERATIONAL TEST, AMBER SQUIB CONTINUITY TEST LIGHT WAS NOT ILLUMINATED. CHECKED WIRING & FOUND DOOR SWITCH S52125 OPEN. R & R SWITCH. PERFORMED OPERATIONAL TEST IAW AMM 52-11-18 & 52-11-20. SYS CHECKED NORMAL.SDR AALA20150706007Battery Pack · failedR4 DOOR EMER LIGHT BATTERY M33409 FAILED CAPACITY TEST. R & R BATTERY PACK M33409. PERFORMED OPERATIONAL TEST IAW AMM 33-51-06. SYS CHECKED NORMAL.SDR AALA20150706006Battery Pack · failedL3 DOOR EMER LIGHT BATTERY M33400 FAILED CAPACITY TEST. R & R L3 DOOR BATTERY PACK M33400. PERFORMED OPERATIONAL TEST IAW AMM 33-51-06. SYS CHECKED NORMAL.SDR AALA20150706002Light · brokenL4 DOOR UPPER LINING EXIT SIGN CATCHES BROKEN. R & R LIGHT ASSEMBLY. PERFORMED OPERATIONAL TEST IAW AMM 33-51-01. SYS CHECKED NORMAL.SDR AALA20150707001Sign · crackedR1 DOOR 1 FWD EXIT SIGN FOUND CRACKED. R & R EXIT SIGN. PERFORMED OPERATIONAL TEST IAW AMM 33-51-01. SYS CHECKED NORMAL.SDR AALA20150706009Sign · crackedL4 DOOR FWD EXIT SIGN FOUND CRACKED. R & R EXIT SIGN. PERFORMED OPERATIONAL TEST IAW AMM 33-51-01. SYS CHECKED NORMAL.