What was found
AIRCRAFT IN BASE MAINTENANCE. EMERGENCY EXIT FLOOR PROXIMITY LIGHTS AFT RIGHT FAILED TEST. REMOVED AND REPLACED POWER SUPPLY M33401 AT R3 DOOR IAW AMM 33-51-06. OPERATIONAL CHECK GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AIRCRAFT IN BASE MAINTENANCE. EMERGENCY EXIT FLOOR PROXIMITY LIGHTS AFT RIGHT FAILED TEST. REMOVED AND REPLACED POWER SUPPLY M33401 AT R3 DOOR IAW AMM 33-51-06. OPERATIONAL CHECK GOOD.