N778UA
Service difficulty reports · 197
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N778UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N778UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2011092605185Antenna · damagedCENTER VHF ANTENNA UPPER FUSELAGE DAMAGED. REPLACED THE CENTER VHF ANTENNA PER MM.SDR UALA2011090704860Display · defectiveFIRST OFFICERS PFD HAS BLACK SPOT ON TOP OF SPEED TAPE-ABOVE IAS. DISPLAY FOUND FAULTY. REPLACED F/O'S PFD.SDR UALA2011090504792Motor · faultyCREW REPORTS FLT CTL STATUS MESSAGE. AUTO SP BRAKE, NO AUTOLAND, THRUST ASYM COMP. CMC FAULTING R ACTUATOR CONTROL ELECTRONICS UNIT, MR27221, PCN 483-9204. MAT SHOWS NO OUTPUT FROM RIGHT ACE TO ALL THREE PFC'S. REPLACED RIGHT ACE PER MM. RPLD RT STAB HYD MSDR UALA2011083004653Module · faultyFLIGHT CONTROL SYS ANY CONDITION OF THE FLIGHT CONTROL SYSTEM OR IT'S SYSTEM INTERFACES WHICH WOULD PREVENT DISPATCH. FLIGHT CONTROLS SYSTEM BELOW MINIMUM DISPATCH REQUIREMENTS. STATUS MSG-2710003 ACTIVE CL HARD MSG-2710003 ACTIVE CL HARD. ACP'D REPLACED RISDR UALA2011082204484Valve · failedECONOMY COOLING VALVE FOR THE RIGHT COOLING PACK FAILED ON MAT TEST. REPLACED VALVE, PASSED TEST.SDR UALA2011082204483Shutoff Valve · failedTRIM AIR PRSOV R RIGHT TRIM AIR PRESSURE RELIEF SHUTOFF VALVE (PRSOV) FAILED. (STATUS - LOCKED IN CLOSED POS). REPLACED VALVE, PASSED TEST ON MAT.SDR UALA2011081504312Rub Strip · missingNR 2 ENGINE RUB STRIP MISSING AREA APPEARS LARGER THAN 2 X 1 INCHES. MEASURES 2.5 X 5 INCHES DAMAGE IN INNER LAYER. DAMAGE LESS THEN 3" IN DIA NEEDS TO BE REPAIRED WITHIN 500T OR 200C PER MM. THE DAMAGED AREA WAS INSPECTED PER CAPTAIN'S REQUEST THE DAMAGE ISDR UALA2011080504094Light · detachedSEAT 1E TRIM NEEDS TO BE RE-ATTACHED. SECURED EMERGENCY LIGHT STRIP TO SEAT. ALL OPS NORMAL.SDR UALA2011072903909Bottle · faultyDOOR 1L FAILS SQUIB CONTINUITY TEST. REF LM1243 AND EPAS TEST TASK. REPLACED DOOR ASSIST BOTTLE, TEST NORMAL. INSPECTED DOOR 1L ASSISTSDR UALA2011062403112Light · missingSEAT 1E AFT EMERGENCY LIGHT IS MISSING FROM SEAT. REPLACED, TESTED GOOD.SDR UALA2011061502941Module · faultyINTERMITTENT STATUS MSG OF DISPLAY RESOURCES HAS OCCURRED. MSG 31-81052, CPM-GG M010 FAULTED. REPLACED M010 AND LOADED ALL SW AS NEEDED. SYSTEM CHECKS NORMAL.SDR UALA2011060302725Window · faultySTATUS MSG FOR LT SIDE WINDOW RETURNED PRIOR DEPT. REPLACED WINDOW.SDR UALA2011051302387Converter · faultyDURING CLIMB-F-O WINDSHIELD WIPER OSCILLATED VIOLENTLY IN OFF POSITION. SAMC TEXT: FROM LOG 3: STOPPED AFTER 5 MINUTES OR WHEN SELECTED TO INT. NOTE: DIFFERENT ACFT WITH SIMILAR FAULT WAS REPAIRED BY ADJ SWEEP PATTERN OF ARM. RPL RT WIPER CONVERTER. RPL WIPERSDR UALA2011051302386Control Panel · contaminatedWX RADAR CONTROL PANEL HAS EVIDENCE OF LIQUID SPILL. REPLACED WX RADAR CONTROL PANEL, OP CHECK AND GROUND TEST OKAY.SDR UALA2011051302385Isolation Valve · faultyCENTER ISOLATION VALVE FAILS CHECK, WON'T SHUTOFF AND FALL BELOW 11 PSI. REPLACED CENTER ISO VALVE LEAK AND OPS CKD GOOD.SDR UALA2011051202355Light · damagedAFT EMERGENCY LIGHT DAMAGED AT 12D. REPLACED LIGHT ASSY OP CHECKS GOOD.SDR UALA2011051202354Light · damagedFORWARD EMERGENCY LIGHT DAMAGED AT 14D. REPLACED LIGHT ASSY, OP CHECKS GOOD.SDR UALA2011041801887Sdu · malfunctionedSATCOM SYS AND HIGH GAIN STATUS MSG. REPLACED SDU PER MM, ALL OPS NORMAL.SDR UALA2011040401597Circuit Card · failedNO DATA FROM RIGHT HYDIM. REPLACED RT HYDIM CARD, OPS CHECKS OKAY.SDR UALA2011040401596Light · inoperativeEEL LIGHTS INOP ON SEAT 9D FWD LIGHT, SEAT 11D FWD LIGHT AND SEAT 13D AFT LIGHT. REPLACED LIGHT ASSY, OPS CHECKS GOOD.SDR UALA2011011800294Tube · obstructedLT AND RT MAIN TANK H20 SCAV JET PUMP CHECK. ACCOMPLISHED H20 SCAV JET PUMP CHECK. FOUND LT JET PUMP NOZZLE CLEAN, NO DEBRIS. FOUND TWO SMALL PIECES OF DEBRIS IN RT JET PUMP NOZZLE. CLEANED NOZZLES AND REINSTALLED. ACCOMPLISHED CHECK OF THE RT TANK VENT TUSDR UALA2011010700119Housing · damagedLEFT WING MAIN AFT BOOST PUMP HOUSING VALVE PLATE WILL NOT PROPERLY CLOSE DURING PUMP REMOVAL. NEEDS HOUSING REPLACED ESTIMATE 4 SHIFTS TO REPLACE. FUEL PUMP INSTALLED WITH NO LEAKS NOTED. WILL REQUIRE TANK ENTRY TO ACCOMPLISH.SDR UALA2011010700117Exciter · failedENGINE IGNITOR R1 RT ENGINE FAILED TO IGNITE USING IGNITOR 1. STATUS MSG-7461492 INACTV ES MODE. EXCITER REF MM. EPLACED EXCITER REF MM. OPS NORMAL.SDR UALA2011010700120Check Valve · failedFUEL PUMP CENTER LEFT CENTER (OVERRIDE) FUEL PUMP SWITCHED ON AND PUMP OUTPUT PRESSURE LOW. INTERMITTANT AND CHRONIC MSG-2811015 INACTV ER MODE. PERFORMED CH1386 AND REPLACED CHECK VALVE.SDR UALA2010121704616Light · missingEMERGENCY EXIT STRIP FROM 3E IS TORN OFF. STRIP ON SIDE OF SEAT MISSING. INSTALLED LIGHT ASSY. OP'S CHECKED OK.SDR UALA2010121604600Check Valve · faulty3 START ATTEMPTS APU FAILED TO START. STARTED APU USING ACFT PNEUMATIC. DEFERRED ISSUE FOR FURTHER T/S IAW MEL 4942A AND COMPLIED WITH MAINT MSG 49-11290. CHECK VALVE, REF: FIM 49-52-00-810 TASK 808 "APU CHECK VALVE FAILED OPEN". REPLACED 2EA APU PNEU CLUSTESDR UALA2010121604601Pump · failedCTR RT FUEL PUMP FAILED. REPLACED RT CTR PUMP. OPS CHECK AND LEAK CHECK RT CTR TANK PUMP, CHECKED GOOD. REPLACED RT MAIN TANK INLET AND OUTLET FLOAT VALVES. PERFORMED FUNCTIONAL TEST SCAVENGE SYSTEM (OKAY). LT & RT FUEL TANKS INDICATIONS NORMAL.SDR UALA2010113004405Pressure Switch · malfunctionedCHRONIC LT CTR TANK FUEL PUMP FAULT RELATED TO MESSAGE. REPLACED CONNECTOR D2189P, WIRE W8189-2001R-20, WIRE W8189-2001B-20, AND CONNECTOR DS28110. INSTALLED NEW PRESSURE SWITCH INW IPC 28-42-01-002 ITEM 22 ACP TEST OF LT CTR FUEL PUMP PRESSURE SWITCH S2811SDR UALA2010111204197Power Supply · inoperativeEMERGENCY EXIT LIGHTS ON SEAT ARE INOP ON SEAT ROWS 11-15. REPLACED POWER SUPPLY ASSY. OPS CHECKS GOOD.SDR UALA2010110504102Guide Vane · damagedNR 2 ENGINE FAILED BORO INSP. FOUND MULTIPLE (MORE THAN 3) T1 NGV WITH T/E BURNBACK MORE THAN 0.15". ALSO FOUND ONE VANE WITH COMPLETE BURN THROUGH THRU BAFFLE FROM CONVEX SIDE TO CONCAVE SIDE WITH CONCAVE SIDE COOLING HOLES VISIBLE.SDR UALA2010110204066Pressure Switch · faultyFUEL PUMP CENTER L LEFT CENTER (OVERRIDE) FUEL PUMP SWITCHED ON AND PUMP OUTPUT PRESSURE LOW. ADVISORY MSG-2811015 INACTV ER MODE. REPLACED CENTER LTH OVHRD JETTISON PUMP PRESS SWITCH. REMOVED PUMP AND CHECKED FOR PUMP DEBRIS, NONE FOUND. REQUIRES OP CHECK. NOSDR UALA2010101903861Relay · faultySTBY ELEC SYS STATUS MESSAGE WITH MAINT MESSAGE 24-13038. WHILE TROUBLESHOOTING PROBLEM, FOUND THAT MESSAGE WOULD GO AWAY AFTER RELAY K24016 TAPPED ON. MESSAGE REAPPEARS AFTER ACCOMPLISHING STANDBY POWER TEST. REPLACED RELAY K24016, OPS CKS OK.SDR UALA2010101803853Light · dislodgedSEAT 3F FWD EMERGENCY LIGHT FELL OUT OF SIDE PANEL. SECURED EMERGENCY LIGHT TO SIDE PANEL.SDR UALA2010100503691Light · brokenEMERGENCY LIGHT BROKEN AT CENTER PARTITION IN 'B' ZONE. REPLACED AND OPS CHECKED LIGHT IAW MM.SDR UALA2010100503690Light · brokenEMERGENCY LIGHT BROKEN AT CENTER PARTITION IN FWD AISLE ZONE. REPLACED AND OPS CHECKED LIGHT IAW MM.SDR UALA2010100403683Power Supply · failedDOOR 2L EMERGENCY BATTERY M33099 FAILED TEST. REPLACED POWER SUPPLY ASSY IAW MM, OP CK GOOD.SDR UALA2010100403682Power Supply · failedDOOR 2L EMERGENCY BATTERY M33096 FAILED TEST. REPLACED POWER SUPPLY ASSY IAW MM. OP CK GOOD.SDR UALA2010100403681Power Supply · failedDOOR 1L EMERGENCY BATTERY M33424 FAILED TEST. REPLACED POWER SUPPLY ASSY IAW MM. OP CK GOOD.SDR UALA2010100403680Power Supply · failedDOOR 1R EMERGENCY BATTERY M33094 FAILED TEST. REPLACED POWER SUPPLY ASSY IAW MM. OPS CK GOOD.SDR UALA2010100403679Power Supply · failedDOOR 3L EMERGENCY BATTERY M33400 FAILED TEST. REPLACED POWER SUPPLY ASSY IAW MM. OPS CK GOOD.SDR UALA2010092803579Connector · disconnected1L PAX ENTRY DOOR EPAS BATTERY FAILS CHECK. CHECKED CIRCUIT IAW WDM. RECONNECTED PLUG DM52105. OPS CHECK OK.SDR UALA2010070202353Smoke Detector · faultyAFT CARGO F-D INOP, FLIGHT DIVERTED. ALL 3 AFT CARGO COMPARTMENT SMOKE DETECTORS ARE FAULTING, (ZONE 1,2,3). HAS PREVIOUS SAME FAULT. CMC BIT SHOWS MT MSG-26-20022 CARGO SMOKE DET (LOWER AFT) HAS AN INTERNAL FAULT RESETTING CHANNEL 1 & 2 CIRCUIT BREAKERS CLSDR UALA2010063002321Display · odorELECTRICAL ODOR IN CABIN. SEAT 1A VIDEO SCREEN POPPED & WENT BLANK. AN ELECTRICAL ODOR WAS NOTED AFTERWARDS BUT DISSIPATED AFTER VIDEO SYS & BUFFER BOXES SELECTED OFF. POSSIBLE VDB BOX FAILURE. SYSTEM REINSTATED. AFTER 10 MIN SLIGHT ELECT ODOR NOTED FROM SDR UALA2010052401765Actuator · faultyCABIN PRESSURE ISSUE, RTFL FWD OUTFLOW ACTUATOR REPLACED. PER CREW OXYGEN PRESSURE INDICATION IS ERRATIC, FROM 0 TO 1820 PSI. VERIFIED DIRECT GAUGE READING AT TANK FULL. FLOW TO MASK NORMAL. POSSIBLE TRANSMITTER AT BOTTLE NEEDED. REPLACED TRANSDUCER. LEAK ANSDR UALA2010051901688Wire Harness · damagedSEAT 3F AFT EMERGENCY LIGHT INOP. FOUND BROKEN PIN IN CONNECTOR NEW HARNESS ORDERED TO LOCK DROP. REPLACED HARNESS UNDER SEAT. OPS NORMAL.SDR UALA2010042201346Idg · failedLEFT GEN FAILURE, FLIGHT DIVERTED. IDG WAS REPLACED AND RUNS GOOD. ALL CHECKS NORMAL. OK FOR SVC.SDR UALA2010030900818Boot · damagedPNEUMATIC DUCT PRESSURIZATION BOOT FOUND CRACKED (TORN) AT LT FUSELAGE AFT WING TO BODY FAIRING JUST ABOVE ADP EXHAUST DUCTS. AFT DUCT AND BOOT REMOVED AWAITING PARTS, THIS IS THE DUCT THAT GOES TO THE LOWER C1 ADP. REPLACED BOTH FWD AND AFT BOOTS.SDR UALA2010030900817Light · unsecureSEAT 2E EEL LIGHT IS HANGING OUT OF SIDE OF ARMREST. SECURED LIGHT. OP CHECKS GOOD.SDR UALA2010012100257Oven · malfunctionedBUSS GALLEY OVEN R31 CB R31 POPPED DID NOT RESET. REPLACED R31 OVEN. OPS GOOD .SDR UALA2010012100256Extinguisher · missingFIRE EXTINGUISHER - MISSING DR-3L FWD LAV 131. REPLACED EXTINGUISHER.
Back to N778UA