N779UA
Service difficulty reports · 201
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N779UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N779UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2011103105893Fmc · faultyFMC R INOPERATIVE. TRIED CYCLING FMC SW TO R AND THEN BACK TO AUTO, NO HELP. THE MAT SHOWS MTC MSG 31 1024. PERFORMED FIM TASK 31-44-866, NO HELP. DEFERRED FMC RT IAW MEL 3461D. -INF- :FIM 31-44 TASK 866 C. FAULT ISOLATION PROCEDURE IF NEEDED CPM 483-90SDR UALA2011102005683Oven · odorFLIGHT ATTENDANT REPORTS A FAIRLY STRONG ACRID ODOR IN BUSINESS GALLEY. STRONGEST NEAR R2 DOOR. ACFT DIVERTED. CONFIRMED OVEN R32 TO BE THE CAUSE OF THE ODOR. WITH R32 OVEN RUNNING IT PRODUCES BURNING ODOR , COLLARED CIRCUIT BREAKER . REPLACED R32 OVEN PER SDR UALA2011093005291Control Valve · faultedRT PACK FLOW CONTROL VALVE OF THE TWO RIGHT PACK FLOW CONTROL VALVES (FCV) ARE NOT IN THE COMMANDED POSITION. STATUS MSG-2124102 LATCHD ER MODE. LOCKED UPPER FLOW CNTL VLV CLOSED PER MEL. REPLACED RT UPPER FLOW CONTROL AND SHUTOFF VALVE PER AMM, OPS CHECK NSDR UALA2011081604337Tube · crackedNR 1 ENG, NR 3 BEARING OIL VENT TUBE CRACKED IN HALF. REPLACED TUBE.SDR UALA2011080304048Apu · making metalDURING GROUND OPS, APU AUTO SHUTDOWN. DRAIN CHIP DETECTOR INSPECTED AND FOUND FULL OF METAL PARTICLES. REPLACED APU.SDR UALA2011080103975Generator · failedAPU GENERATOR TRIPPED WITH A LOAD. APU GEN INOP. REPLACED APU GENERATOR PER MM. MAINT MESSAGE 24-31613 FIELD CURRENT OUT OF RANGE.SDR UALA2011071303497Guard · brokenGUARD FOR EMERGENCY LIGHT SWITCH IN COCKPIT SPRING BROKEN. REPLACED EMERGENCY LIGHT SWITCH GUARD & RE-INSTALLED PANEL PER MM.SDR UALA2011071103451Cdu · faultyR FMC CDU FAILED. SWAPPED CDU TO CENTER POSITION PER MEL. REPLACED CENTER CDU PER MM. PASSED ALL TEST, OPS CHECK GOOD.SDR UALA2011061502940Slat · damagedRT WING NR 8 LEADING EDGE SLAT HAS DAMAGE.SDR UALA2011050602223Probe · faultyLEFT WING FUELING VALVE ONE VALVE INOP PER FUELERS. REPLACED LEFT MAIN PROBES. REPLACED FUEL QTY PROCESSOR UNIT, CONFIGURATION CHECK'S GOOD WITH OLD UNIT.SDR UALA2011050502214Transceiver · out of toleranceAFT XCVR IS OUT OF TOLERANCE. XCVR REPLACED.SDR UALA2011032801457Pressure Sensor · faultyEQUIPMENT COOLING ADVISORY MSG AS PER MT 21-004 R3, CLEANED SUPPLY FAN INLET AIR FILTER AND CLEANED FD PRESSURE TRANSDUCER PLUG. EQUIPMENT COOLING GROUND TEST PASSED WITH NO STATUS OR ADVISORY MESSAGE. IDENTIFIED THE PROBLEM RMVG THE CONNECTOR FROM FD PRESSUSDR UALA2012031601731Fastener · faultyPYLON ACCESS PANEL 443BL HAS 3 SCREWS AND 3 INDICATORS THAT NEED REPLACING. REPLACED FASTENERS AND REINSTALLED PANEL.SDR UALA2011030201030Pressure Switch · faultyHYDRAULIC SYSTEM PRESSURE INDICATION FAULTS. REPLACED 'C' HYD RESERVOIR PRESSURIZATION MODULE AND PRESSURE RESERVOIR PRESSURE SWITCH, NO HELP. ACCOMPLISHED CHECKS PER LM 7807 AND CH1523, C HYD PRESSURE MODULE AND PRESSURE SWITCH S29306 REPLACED. REPLACED COSDR UALA2011030201019Switch · faultyLOSS OF THRUST ASYMMETRY COMPENSATION (TAC) FUNCTION. STATUS MSG01- LATCHED CLIMB MODE DEPENDENT; THRUST ASYM COMP SWITCH IS INVALID. DB- PRIMARY FLIGHT COMPUTER (LEFT) ITEM CNX PER PLF SHOWS NOT ACTIVE MSG-2710807 LATCHED CL MODE. REPLACED THRUST ASYM COMPSDR UALA2011021400786Processing Unit · inoperativeFUEL IMBALANCE LT AND RT MAIN TANK QUANTITIES DIFFER BY A PRE-DETERMINED AMOUNT. REPLACED FUEL QTY PROCESSOR UNIT (FQPU) IAW MM. REPLACED FUEL TANK UNIT (18L) IAW MM.SDR UALA2011021000705Valve · faultyRT FUEL JETT NOZZLE VALVE FAILS TEST IN OPEN POSITION. VALVE TESTS GOOD IN CLOSED POSITION. REMOVED AND STARTED INSTALLATION OF RT FUEL JETT NOZZLE VALVE ACTUATOR. COMPLETED INSTALLATION, NEW VALVE NO HELP. SUSPECT VALVE IS BOUND UP AND STIFF.SDR UALA2011020700633Valve · faultyDURING LEAK CHECK OF LT INBD REFUEL VALVE, VALVE WOULD NOT CLOSE. FOUND NEW CONTROL VALVE FOR LEFT INBD FILL VALVE MANUAL CONTROL KNOB FROZEN. REPLACED CONTROL VALVE. FILL VALVE OPERATES NORMAL.SDR UALA2011013100531Switch · failedDOOR 4R EPAS BATTERY OP TEST, AMBER TEST LIGHT ON EPAS BATTERY. DOES NOT COME ON. FOUND DOOR OPEN SWITCH BAD. R & R SWITCH IAW MM. OPS CHECKED GOOD. ALSO THE NR4 RT PAX ENTRY DOOR EPAS RESERVOIR PRESSURE INDICATOR IS LOOSE. REPLACED RESERVOIR IAW MM, OPSSDR UALA2011012800476Power Supply · inoperativeDOOR 4R EMERGENCY POWER SUPPLY M33409 DID NOT KEEP LIGHTS ILLUMINATED FOR 15 MINUTES. REPLACED POWER SUPPLY.SDR UALA2011012600438Connector · faultyDOOR 2L EPAS BATTERY OP TEST, AMBER TEST LIGHT ON EPAS BATTERY DOES NOT COME ON. T/S IAW WDM. TEST IS OK. R & R PLUG DS52125. OPS CK GOOD.SDR UALA2010123004777Battery · reads lowFLT CONTROL SYS STATUS MESSAGE DISPLAYED WITH MAINT MSG 24-50241 LT FC BATTERY VOLTAGE LOW. REPLACED LT FCDC BATTERY IAW MM, OPS CHECK GOOD, MESSAGE GONE.SDR UALA2010122704723Card · failedON ARRIVAL EQUIP COOLING HORN IS BLOWING. TROUBLESHOOTING SYS, FOUND ESS MC-R- CARD SYS FAILING. DEACTIVATED CARD IAW MEL. REPLACED RT ECS CARD, NO HELP. SUSPECT CLOGGED SUPPLY INLET FILTER OR PRESSURE TRANSDUCER. IF NO HELP UTILIZING MT, SUSPECT ECSMC INSTSDR UALA2010122104666Circuit Card · failed'ECS CARD R' STATUS MESSAGE WITH CORRELATED MMSG 21-18892, REPLACED ECS R CARD IAW MM, NO HELP. ECS EQUIP COOLING TEST FAILED FOR RT SIDE. GOT MESSAGE 21-14022 FOR TEST. NO COOLING HORN WITH RT ECS CARD OFF IAW MEL 2100A.SDR UALA2010122004632Sensor · faultyLEFT EQUIP COOLING FAN STATUS MESSAGE. SUPPLEMENTAL DATA UPDATE REPLACED LEFT FAN, FLOW SENSOR AND FILTER PER MM DUE TO COOLING HORN ON CONTINUOUS WITH LOW FLOW FAULT. OPS NORMAL.SDR UALA2010121004520Shutoff Valve · faultyPACK FCV L (1) (BUT NOT BOTH) OF THE (2) LT PACK FLOW CONTROL VALVES (FCV) ARE NOT IN THE COMMANDED POSITION. STATUS MSG01- LATCHED CLIMB MODE DEPENDENT; LOWER FLOW CONTROL AND SOV (L PACK) TORQUE MOTOR IS NOT IN COMMANDED POSITION. DB- CABIN TEMPERATURE CONSDR UALA2010120904496Shutoff Valve · malfunctionedOVERHEAT IN ZONE SUPPLY DUCT, LEFT TRIM PRSOV FAILED CLOSED, LEFT TRIM AIR SWITCH COMMANDED OFF. ADVISORY DEFERRED DUE TIME. AIR CON RESET, LEFT TRIM FAULT COMES BACK WITH STATUS MESSAGE LT TRIM AIR, NO MAINT MESSAGE, LT TRIM SYSTEM GROUND TEST PASS BUT FAULSDR UALA2010120904494Bleed Valve · failedFOUND 2.9 START BLEED VALVE FAILED CLOSED NR1 ENG. AFTER TROUBLESHOOTING, REPLACED CLOGGED PS3 FILTER BUT FOUND BAD BLEED VALVE. REMOVED VALVE, INSTALLED VALVE. ACCOMPLISHED REPLACEMENT OF P3 FILTER. CHECKED OPS OF VALVE. NO CLUNK. BORO'ED FOUND VALVE FAILSDR UALA2010120804486Shutoff Valve · faultyC2 DEMAND PUMP SHOWS 600-1000 PSI WITH PUMP IN AUTO AT CRUISE. POSSIBLE AIR LEAK FROM MODULATING SHUTOFF VALVE TO ADP. WILL NEED VALVE & TUBES. REPLACED ADP MODULATING SHUTOFF VALVE. REPLACED TUBING. NEEDS INSTALLATION TEST.SDR UALA2010120604466Spring · brokenDURING TESTING OF LT PACK SYS, HEARD A TATTLING METALLIC NOISE COMING FROM THE LT PACK REHEATER, SUSPECT A SMALL BROKEN PIECE OF METAL INSIDE THE REHEATER. FOUND A BROKEN BONDING SPRING RING INSIDE THE REHEATER, REMOVED ALL BROKEN PARTS AND REPLACED BONDING SSDR UALA2010120604459Sensor · faultyCREW REPORT LT TRIM AIR PRESSURE FLUCTUATING, POOR AIR QUALITY, AND TEMP CTL DIFFICULT. SELECTED THE LT TRIM AIR SWITCH TO OFF IAW FLT MAN AS A PRECAUTION. SAMC TEXT: CREW REPORT AIR HAD AN OZONE TYPE ODOR, IMPROVED WITH TRIM AIR SWITCH OFF. ACP FIM 21-51 T8SDR UALA2010102203916Light · inoperativeEMERGENCY LIGHT AT MID GALLEY FLOOR LEVEL RT FRONT IS OUT. REPLACED EMERGENCY LIGHT MID GALLEY FLOOR LEVEL RT FRONT. CHECKS OK.SDR UALA2010102203917Lamp · inoperativeEMERGENCY LIGHT AT SEAT 12F AFT IS OUT. RELAMPED EMERGENCY LIGHT AT SEAT 12F. CHECKS OK.SDR UALA2010091603455Socket · burnedLAVATORY 125 MIRROR LIGHT SOCKET BURNED. FOUND MIRROR LIGHT SOCKET BURNED ON ONE SIDE. REMOVED BULBS AND DISCONNECTED BALLAST FOR MIRROR LT. DF MIRROR LT IN LAV 125 IAW MEL.SDR UALA2010082403120Oven · contaminatedSMOKE FROM OVEN. NOT INSERT. REMOVED INSERT FROM OVEN. FOUND MULTIPLE FOOD SPILLS ON INSERT WHICH WAS BURNED AND THE CAUSE OF THE SMOKE. OPS CHECKED OVEN WITH NO INSERT FOR 50 MIN. NO SMOKE EMITTING FROM OVEN. OVEN OPS CHECK OK. REMOVED INSERT FOR CLEANING OVESDR UALA2010071502535Slide · reads lowDOOR 1R SLIDE PRESSURE NEEDLE IN RED 'NO GO' BAND. SLIDE READS LOW. REPLACED ESCAPE SLIDE PACK ASSY.SDR UALA2010062302225Isolation Valve · failedLT ENG BLEED ISOLATION VALVE MESSAGE, FLIGHT DIVERTED. ACCOMPLISHED CHECK OF CMC FOR FAULT MSGS REGARDING LT ISOLATION VALVE. FAULT SHOWED ISOLATION VALVE FAILED IN CLOSED POSITION. ACP TEST OF LT & RT AIR SUPPLY SYS THROUGH CMC. TESTS PASSED. LOCKED LT ISOSDR UALA2010041301249Lamp · inoperativeEMERGENCY AISLE LIGHTS INOP AT SEATS 1E, 14D AND 22C. RELAMPED 14D AND 22C. SECURED CONNECTOR ON 1E, OPS CHECK NORMAL.SDR UALA2010041301248Battery Pack · inoperativeDOOR 1L EPAS BATTERY IS INOPERATIVE. REPLACED 2 EA, 9V BATTERYS, OPS CHECK OK. INSP EPAS PACK, PACK SECURE ON DOOR 1L, PACK IN ARMED POSITION LIGHT BLINKING REF METHOD NR 4.SDR UALA2010021500554Lamp · inoperativeEMERGENCY LIGHT INOP AT 2F AFT. RELAMPED. TESTED GOOD.SDR UALA2010012200265Casting · brokenDOOR 2R WHEN DOOR IS OPENED ARMING LEVER GOES TO ARM. FOUND BROKEN CASTING. REMOVED CASTING. BROKEN CASTING ON SHELF ON MID GALLEY. CASTING AT LOWER FWD END OF THE NR 2R MAIN CABIN DOOR. BROKEN CASTING ON SHELF ON MID GALLEY. FOUND DOOR 2R ASSIST BOTTLE PRSDR UALA2009121603900Line · leakingCTR HYD SYS FAILED AFTER LOWERING GEAR. PRESSURE LESS THAN 1200 PSI. RESERVOIR (CENTER) FLUID QUANTITY IS LOW. FOUND NOSE GEAR STEERING HYD HOSE RUPTURED. RPL HOSE. REPLENISHED CTR HYD SYSTEM. LEAK CHK SATISFACTORY. A-C RELEASED FOR SERVICE.SDR UALA2009113003674Lamp · brokenSEAT 1E EMERGENCY LIGHT BROKEN OFF. RELAMPED EMERGENCY LIGHT OP CHECKS GOOD.SDR UALA2009102703355Amplifier · failedSATCOM FAILURE. SATCOM IS MALFUNCTIONING. REPLACED HIGH POWER AMPLIFIER. REPLACED SATELLITE. REPLACE BEAM STEERING UNIT ON LEFT SIDE. ALL OPS OKAY.SDR UALA2009091802954Light · inoperativeSEAT 1E AFT EEL LIGHT INOPERATIVE. REPLACED LAMP ASSY, OPS CHECK NORMAL.SDR UALA2009091802953Connector · looseSEAT 2E HAS BOTH FWD AND AFT EEL LIGHTS INOPERATIVE. SECURED CONNECTOR, OPS CHECK NORMAL.SDR UALA2009083102703Light · unsecureEMERGENCY LIGHTS ON SEAT 1B ARE LOOSE. SECURED LIGHTS.SDR UALA2009081002428Light · unsecureSEAT 1E EMERGENCY LIGHT ON AISLE KEEPS HANGING DOWN. LIGHT STRIP FIXED ON SIDE.SDR UALA2009072302193Shutoff Valve · faultyTRIM AIR R ADVISORY MSGS. REPLACED TRIM AIR PRSOV.SDR UALA2009071402072Door · malfunctionedDOOR 2R DISARMED ITSELF IN FLIGHT CANNOT BE RE-ARMED. REMOVED DOOR SLIDE TO INSPECT DOOR ARMING CABLE AND GIRT BAR MECHANISM. INSPECTED ALL AREAS OF CABLE AND ARMING MECHANISM. FOUND NO DEFECTS DOOR ARMED AND DISARMED NORMALLY. REINSTALLED DOOR SLIDE. ACC