What was found
FMC R INOPERATIVE. TRIED CYCLING FMC SW TO R AND THEN BACK TO AUTO, NO HELP. THE MAT SHOWS MTC MSG 31 1024. PERFORMED FIM TASK 31-44-866, NO HELP. DEFERRED FMC RT IAW MEL 3461D. -INF- :FIM 31-44 TASK 866 C. FAULT ISOLATION PROCEDURE IF NEEDED CPM 483-9051 AND CPM-ACMF 483-9052. -INF- :FOR CPM-ACMF MM 31-41-01- 400-801. -INF- :REF FIM ABOVE. THE M002 MODULE FOR RT AIMS NORMALLY AND FIRST CHOICE IS THE CPM BASIC THAT IS 483-9051. CPM-ACMF MODULES MUST BE USED IN LT AIMS SO IT IS PREFERRED TO SAVE SPARES FPR LT AIMS DEFECTS. -INF- :REPLACED THE RIGHT AIMS MOO2 MODULE, FOUND IT TO BE BAD OUT OF STOCK, DISPLAYED FMC R AND AUTOTHROTTLE SYSTEM STATUS MESSAGES, REINSTALLED ORIGINAL MODULE. NEEDS SERVICEABLE M002. PART ON AOG. RDF-T :NOT ENOUGH GROUND TIME. REPLACED FAILED RT AIMS M002 & LOADED CORRECT SOFTWARE.