N78003
Service difficulty reports · 77
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N78003' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N78003' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2026072017891Generator · faultedELEC BACKUP GEN R EICAS STATUS RIGHT BACKUP GENERATOR OFF DUE TO A PROTECTIVE TRIP. DB BACKUP CONVERTER R&R E2 BUG IAW AMM 24-25-01. SECOND QUALIFIED MECHANIC WITNESSED NEW BUG SHAFT PACKING REPLACED. C/W IDT INSPECTION OF BUG FEEDER CABLE INSTALLATION IAWSDR CALA2026030914425Lamp · burned outEMERGENCY LIGHTS OPERATIONAL TEST WITH THE CONTROL SWITCHES PROCEDURE - IT WAS FOUND BETWEEN 10A AND 11A SEAT AREA LIGHT INOPERATIVE. IT WAS DONE AREA LIGHT LAMP REPLACEMENT IN REF AMM TASK 33-51-03-960-801.SDR CALA2025101309978Lens · missingUPON ARRIVAL NOTED RT WING ANTI-COLLISION LENS MISSING.PIC ATTACHED PARTS NEEDED NIS AT GRU. PERFORMED A VISUAL INSPECTION OF THE STROBE LIGHT LENS HOUSING AND CAVITY FOR ADDITIONAL DAMAGE, AND NO ADDITIONAL DAMAGE WAS NOTED. PERFORMED INTERIM REPAIR PART 1 ASDR CALA2025090508519Elec Connector · brokenFA REST AREA BUNK 5 SMOKE DETECTOR INOPERATIVE. REMOVED AND REPLACED AFT OCAR NR 5 BUNK DETECTOR IAW AMM 26-14-11, NO HELP. FOUND WRONG SMOKE DETECTOR INSTALLED, . REMOVED AND REPLACED AFT FLIGHT CREW REST SMOKE DETECTOR IAW AMM-TASK 26-14-11-000-801, TASKSDR CALA2025051204614Engine · faultyLEFT ENGINE N1 VIBE UP TO 5.0 DURING CLMB OUT ENG1 SN. 900496 (TSI= 20319 HRS / 2557 C). REL L/P 4765754, METAL FOUND IN TAIL PIPE, REQUIRES ENGINE REPLACEMENT. BEGINNING #1 ENGINE CHANGE PREPERATION PER AMM 71-00-02-000-802-G00. ENGINE CHANGE PREPERATION PERSDR CALA2025042204133Battery Pack · dischargedCABIN DOOR 2L M33099 EMER LIGHT BATT PACK TESTED FAILED. CABIN DOOR 2L M33099 EMER LIGHT BATTERY PACK REPLACED AND TESTED NORMAL IAW AMM33-51-06.SDR CALA2025042204132Battery Pack · dischargedCABIN DOOR 4R M33408 EMER LIGHT BATT PACK TESTED FAILED. CABIN DOOR 4R M33408 EMER LIGHT BATTERY PACK REPLACED AND TESTED NORMAL AS PER AMM33-51-06SDR CALA2025042104059Battery Pack · dischargedCABIN EMERGENCY LIGHT BATTERY PACK ON M33098 FAIL ON DEEP CYCLE PROCEDURE.SDR CALA2025042104058Battery Pack · dischargedCABIN EMERGENCY LIGHT BATTERY PACK ON M33093 FAIL ON DEEP CYCLE PROCEDURE.SDR CALA2025042104057Battery Pack · dischargedCABIN EMERGENCY LIGHT BATTERY PACK ON M33096 FAIL ON DEEP CYCLE PROCEDURE.SDR CALA2025042104056Battery Pack · dischargedCABIN EMERGENCY LIGHTS BATTERY PACK M33404 FAIL ON DEEP CYCLE PROCEDURE.SDR CALA2025012201960Lamp · inoperativeDOOR 4R EXTERIOR EMERG LIGHT INOP RELAMPED DOOR 4R EXTERIOR LIGHT IRW 33-51-04. OPS CHECK OK. PARTS USED: 99-3351-3-0014,QTY :1SDR CALA2025011001856Smoke Detector · false activationSMOKE REST UPPER DR 3 EICAS CAUTION SMOKE IS DETECTED IN THE UPPER CREW REST COMPARTMENT AT DOOR 3. ON ARRIVAL TO AIRCRAFT NIL WARNINGS ON EICAS OR CACP. APU STARTE D AND PACK AIR SUPPLIED. CREW REST AND SURROUNDING LAVS INSPECTE D. NO SMELLS DETECTED AND ALL SDR CALA2025010601813Unknown · odorSMOKE REST UPR DR 3 WENT OFF DURING APPROACH NO SMOKE FOUND BOTH FLT CREW AND CABIN CREW REPORTED BURNING PLASTIC SMELL, NO SMOKE. CABIN CREW REPORTED SMELL NEAR LOWER CREW REST AREA. PERFORMED FLIGHT CREW REST SMOKE DETECTION OPERATIONAL TEST REF AMM 26-14-10SDR CALA2024121301501Cable · out of position11G PASSENGER REPORTS GRINDING SND/MELTING PLASTIC ODOR WHEN REC LIN SELECTED SEATS: 11GSEAT 11G IS ABLE TO MOVE WITH USE OF ELECTRIC OR MANUAL CONTROLS. SEAT NOT TO BE USED. REQUEST TO PLACE ON MEL. CORRECTION: SEAT 11G IS ABLE TO MOVE WITHOUT USE OF ELECTRICSDR CALA2024011900147Battery · no testCABIN R1 DOOR EXIT SIGN FAILED TO OPERATION REF HAECO NON-ROUTIN E NO.:9476534,ORIGINATED BY EMP V905376,SPEC NO.B777-33-3-7030. R1 DOOR EMERGENCY (M33094) POWER SUPPLY REPLACED AND SET THE TEST SWITCH TO ON MODE FOUND R1 DOOR EXIT SIGN LIGHT COME ON AS PER AMSDR CALA2023042101207Control Unit · warning messageFLIGHT CONTROL SYS EICAS STATUS ANY CONDITION OF THE FLIGHT CONTROL SYSTEM OR IT''S SYSTEM INTERF ACES WHICH WOULD PREVENT DISPATCH. FLIGHT CONTROLS SYSTEM BELOW MINIMUM DISPATCH REQUIREMENTS. FIM TASK REF : FIM TASK REFERENCE NOT FOUND CMC MSG# 2711510 FLIGHSDR CALA2022081602098Structure · crackedEA 5380-01113 REV B OP 017 LH BS 2370 PIVOT BULKHEAD FORWARD CHORD CRACK FOUND AS MARKED. PLEASE GENERATE EA 5380-01113 REV B OP 25. TRANSFER REF NR HX WO.999860 AND ORIGINATED BY EMP V914372. LH BS 2370 PIVOT BULKHEAD FORWARD CHORD REPLACEMENT AS PER EA 5380-SDR CALA2022081602097Structure · crackedEA 5380-01113 REV B OP 018 - RH BS 2370 PIVOT BULKHEAD FORWARD CHORD CRACK FOUND AS MARKED. PLEASE GENERATE EA 5380-01113 REV B OP 26. TRANSFER REF NR HX WO.999862 AND ORIGINATED BY EMP V914732. RH BS 2370 PIVOT BULKHEAD FORWARD CHORD REPLACEMENT AS PER EA 538SDR CALA2022081002004Charger · failedCABIN L/H DR4 FWD CEILING EMERGENCY LIGHT 45ABC-52ABC CAPACITY CHECK FOUND LESS THAN 15 MINUTES TRANSFER REF NR HX WO.946167 AND ORIGINATED BY EMP V897792. CABIN: DOOR NO.4 L/H HEADER EMERGENCY LIGHT CHARGER AND BATTERY REPLACED LIGHTING CHECK NORMAL AS PER AMSDR CALA2022081002003Charger · failedCABIN AFT ZONE L/H SEAT ALL EMERGENCY LIGHT CAPACITY CHECK FOUND LESS THAN 15 MINUTES TRANSFER REF NR HX WO.946153 AND ORIGINATED BY EMP V897792. CABIN: AFT ZONE L/H EMERGENCY LIGHT CHARGER AND BATTERY REPLACED LIGHTING CHECK NORMAL AS PER AMM 33-51-00 WORK ACSDR CALA2022081002002Battery Pack · inadequateCABIN R/H DR3 AFT CEILING EMERGENCY LIGHT R/H DR3 TO 44HJK CAPACITY CHECK FOUND LESS THAN 15 MINUTES TRANSFER REF NR HX WO.946172 AND ORIGINATED BY EMP V897792. DOOR NO.3 R/H HEADER EMERGENCY LIGHT CHARGER AND BATTERY REPLACED,LIGHT CHECK NORMAL AS PER AMM 33-SDR CALA2022081002001Battery Pack · reads lowCABIN AFT ZONE R/H SEAT ALL EMERGENCY LIGHT CAPACITY CHECK FOUND LESS THAN 15 MINUTES TRANSFER REF NR HX WO.946141 AND ORIGINATED BY EMP V897792. CABIN: AFT ZONE R/H HEADER EMERGENCY LIGHT CHARGER AND BATTERY REPLACED AND LIGHTING CHECK NORMAL AS PER AMM 33-51SDR CALA2022050901189Lens · missingPDA 2 FOUND STROBE LIGHT LENS MISSING ON LH WINGTIP. SEE ATTACHED PHOTOS. ACCOMPLISH PER PART 2 AND ACCOMPLISH PERMANENT REPAIR PER PART 3 WITHIN 3 CYCLES. PERFORMED PART 1 INTERIM REPAIR OF ECRA 3344-01146 ON LH WING TIP ANTI COLLISION (STROBE LIGHT)LENS COVSDR CALA2022042101048Shroud · damagedRIGHT ENGINE ABRADABLE SHROUD AT 9 O''CLOCK POSITION: MATERIAL MISSING, DIMENSION IS 0.75 INCH X 1 INCH X 0.14 INCH DEEP. PERFORMED ABRADABLE SHROUD INSPECTION PER AMM TASK 72-24-00-200-802-G00. AREA OF MISSING MATERIAL IS WITHIN LIMIT AND OK FOR UNLIMITED FLISDR CALA2021021500177Battery Pack · weakSUPPORT TASK - AFT ZONE LH CEILING EMERGENCY LIGHT FOUND DIM REF NR LP 9130270 DR L4 EMER LT PWR SUPPLY M33407 BATT PACK REPLACED AND TESTED NO RMAL AS PER AMM 33-51-06.SDR CALA2021021500170Battery · failedSUPPORT TASK - AFT ZONE LH CEILING EMERGENCY LIGHT FOUND DIM REF NR LP 9130270 DR L3 M33405 AND M33407 EMER LIGHT PWR SUPPLY 2EA BATTERY PACK R EPLACED AND TESTED NORMAL AS PER AMM 33-51-06.SDR CALA2019080501318Valve · failedT/O CONFIG WARNING - PARKING BRAKE. REPEAT FAULT ACFT STARTED TAKE OFF ROLL ABORTED AT 30 KNOTS. REMOVED AND REPLACED MLG PARKING BRAKE VALVE. REF AMM 32-44-04. OPS AND LEAK CHECKS GOOD. ROTABLE PARTS CHANGE WAS INDICATED - TT # 1414663 SN OFF 1689 VALVE, MLGSDR CALA2019080501317Drive Unit · failedWINDSHEAR PRED EICAS STATUS PREDICTIVE WINDSHEAR FUNCTION OF THE WEATHER RADAR UNIT IS FAILE D. REMOVED AND REPLACED WEATHER RADAR DRIVE UNIT PER AMM 34-43-03-400-801. REF IPC 34-43-05-01. ACCOMPLISHED WXR ANTENNA DRIVE UNIT INSTALLATION TEST PER AMM 34-43-0SDR CALA2019071301184Powerpack · failedSUPPORT TASK - EA 2500-04866 M33407 EMERGENCY POWER PACK CAPACITY CHECK FOUND FAIL REF NR LP 9131820 M33407 EMERGENCY POWER PACK REPLACED AND TEST NORMAL AS PER AMM 33-51-06.SDR CALA2019071301180Battery · failedSUPPORT TASK - EA 2500-04866 M33424 EMERGENCY POWER PACK CAPACITY CHECK FOUND FAIL REF NR LP 9131819 M33424 EMER PWR PACK BATTERY REPLACED & TEST OKAY IAW AMM 33-51-06.SDR CALA2019071301179Power Port · failedSUPPORT TASK - EA 2500-04866 M33400 EMERGENCY POWER PACK CAPACITY CHECK FOUND FAIL REF NR LP 9131789 M33400 EMERGENCY POWER PACK REPLACED AND INSTALLATION TEST CARRIED OUT NORMAL AS PER AMM 33-51-06.SDR CALA2019071301178Power Port · failedSUPPORT TASK - M33405 EMER POWER PACK CAPACITY CHECK FAIL REF NR LP 9131795 EMER POWER PACK M33405 REPLACED AND INSTALLATION TEST CARRIED OUT NORMAL AS PER AMM 33-51-06.SDR CALA2019071301177Powerpack · failedSUPPORT TASK - M33406 EMER POWER PACK CAPACITY CHK FAIL REF NR LP 9131794 EMER POWER PACK M33406 REPLACED AND INSTALLATION TEST CARRIED OUT NORMAL AS PER AMM 33-51-06.SDR CALA2019070501136Battery · lowB777-33-3-0018:L2 DOOR EMR PWR SUPPLY M33096 BATTERY FOUND LOW CAPACITY REF NR LP9130320 L2 DOOR EMR PWR SUPPLY M33096 BATTERY WAS REPLACED AND INSTALLATION TEST NORMAL IAW AMM 33-51-06.SDR CALA2019070401135Battery · lowB777-33-3-0018:R4 DOOR EMR PWR SUPPLY M33408 BATTERY FOUND LOW CAPACITY REF NR LP9130338 R4 DOOR EMR PWR SUPPLY M33408 BATTERY WAS REPLACED AND INSTALLATION TEST NORMAL IAW AMM 33-51-06.SDR CALA2019070401134Charger · inoperativeB777-33-3-0018: R3 DOOR EMR PWR SUPPLY M33404 BATTERY PACK CAPACITY CHECK FOUND FAIL REF NR LP9130336 R3 DOOR EMR PWR SUPPLY M33404 BATTERY PACK CHARGER WAS REPLACED AND INSTALLATION TEST NORMAL IAW AMM 33-51-06.SDR CALA2019070401133Charger · inoperativeB777-33-3-0018: R4 DOOR EMR PWR SUPPLY M33408 BATTERY PACK CAPACITY CHECK FOUND FAIL REF NR LP9130332 R4 DOOR EMR PWR SUPPLY M33408 BATTERY PACK CHARGER WAS REPLACED AND INSTALLATION TEST NORMAL IAW AMM 33-51-06.SDR CALA2019070401132Battery · lowB777-33-3-0018: L1 DOOR EMR PWR SUPPLY M33093 BATTERY FOUND LOW CAPACITY REF NR LP9130341 L1 DOOR EMR PWR SUPPLY M33093 BATTERY PACK REPLACED AND INSTALLATION TESTED NORMAL IAW AMM 33-51-06.SDR CALA2019070401131Charger · inoperativeB777-33-3-0018: L2 DOOR EMR PWR SUPPLY M33096 BATTERY PACK CAPACITY CHECK FOUND FAIL REF NR LP9130334 L2 DOOR EMR PWR SUPPLY M33096 BATTERY PACK CHARGER WAS REPLACED AND INSTALLATION TEST NORMAL IAW AMM 33-51-06.SDR CALA2019070301130Battery · lowB777-33-3-0018: R3 DOOR EMR PWR SUPPLY M33404 BATTERY FOUND LOW CAPACITY REF NR LP9130340 R3 DR FMR PER SUPPLY M33404 BATTERY PACK REPLACED AND INSTALLATION TESTED NORMAL IAW AMM 33-51-06.SDR CALA2019041900590Tube · brokenL ENG INFLIGHT SHUTDOWN AND AIR RETURN BACK TO PVG DUE TO OIL PRESSURE INDICATION (ENGINE) AMBER LEFT ENGINE DUE TO TRF BALANCE TUBE FOUND BROKEN AND DAMAGE TO THE CVT REPLACE ESN 900272 PRIOR TO NEXT FLIGH.ENGINE HAS BEEM REMOVED PER JOB CARD 25-7100-0911. THSDR CALA2019041900589Tube · brokenL ENG INFLIGHT SHUTDOWN AND AIR RETURN BACK TO PVG DUE TO OIL PRESSURE INDICATION (ENGINE) AMBER LEFT ENGINE DUE TO TRF BALANCE TUBE FOUND BROKEN AND DAMAGE TO THE CVT REPLACE ESN 900272 PRIOR TO NEXT FLIGH.ENGINE HAS BEEM REMOVED PER JOB CARD 25-7100-0911. THSDR CALA2019041900588Tube · leakingL ENG INFLIGHT SHUTDOWN AND AIR RETURNED BACK TO DEPARTURE DUE TO OIL PRESSURE INDICATION (ENGINE) AMBER LEFT ENGINE DUE TO TRF BALANCE TUBE FOUND BROKEN AND DAMAGE TO THE CVT REPLACE ESN 900272 PRIOR TO NEXT FLIGHT. ENGINE HAS BEEM REMOVED PER JOB CARD 25-71SDR CALA2017121504464Lens · missingON CHECK FOUND EMER LT COVER MISSING EMER LT COVER REPLACED IAW AMM 33-51-00SDR CALA2017081102609Battery · inoperativeCOCKPIT FLASHLIGHT RED INDICATOR LIGHT NOT FLASHING. REPLACED THE BATTERY, CHECKED GOOD.SDR CALA2017062601995Battery · faultyEMER FLASHLIGHT DOOR 4 JS AFT FACING CENTER REMOVED AND REPLACED EMERGENCY FLASHLIGHT BATTERY. OPS CHK NORMAL.SDR CALA2017062301949Lens · missingROW 8E SIDE EMERGENCY LIGHT LENS MISSING. INSTALLED A NEW LENS .SDR CALA2017050801290Battery Pack · dischargedEMERGENCY LIGHT NOT ILLUMINATED. POWER PACK M9429 AND M33404 WERE REPLACED AND TEST CARRIED OUT NORMAL IAW AMM 33-51-06SDR CALA2017010900041Seal · leakingRT ENG OIL QUANTITY DEPLETED TO 1 QT. EMERGENCY DECLARED. RESOLVED LEAK BETWEEN ENG STARTER AND ACCESSORY GEAR BOX. REMOVED NR 2 ENG STARTER PER AMM 80-11-01-000-802-G00 INSTALLED STARTER SEAL KIT 25-8011-3-0007. RE-INSTALLED STARTER PER AMM 80-11 -01-400-802-
Back to N78003