N785UA
Service difficulty reports · 189
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N785UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N785UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2018040301062Sign · brokenTWO EXIT SIGNS FOUND BROKEN. REPLACED THE SIGNS, OPS TESTED GOOD IAW AMM 33-51-01-960-801, REV 82.SDR CALA2018032901059Battery Pack · dischargedMAIN DECK L1 DOOR HAD TWO EMERGENCY LIGHT BATTERY PACKS M33093 & M33424, TO HAVE LOW CAPACITY. REPLACED THE BATTERY PACKS, TESTED GOOD IAW AMM 33-51-06-960-802, REV 82.SDR CALA2018032901058Battery Pack · dischargedMAIN DECK R1 DOOR HAD ONE EMERGENCY LIGHT BATTERY PACK M33094 TO HAVE LOW CAPACITY. REPLACED BATTERY PACK AND OPS TESTED GOOD IAW AMM 33-51-06-960-802, REV 82.SDR CALA2018032901057Battery Pack · dischargedMAIN DECK L2 DOOR HAD ONE EMERGENCY LIGHT BATTERY PACK M33096 TO HAVE LOW CAPACITY. REPLACED THE BATTERY PACK, TESTED GOOD IAW AMM 33-51-06-960-802, REV 82.SDR CALA2018032901056Battery Pack · dischargedMAIN DECK L3 DOOR HAD ONE EMERGENCY LIGHT BATTERY PACK M33406 TO HAVE LOW CAPACITY. REPLACED THE BATTERY PACK, OPS TESTED GOOD IAW AMM 33-51-06-960-802, REV 82.SDR CALA2018032901055Battery Pack · dischargedMAIN DECK L4 DOOR ONE EMERGENCY LIGHT BATTERY PACK M33407 HAD LOW CAPACITY. REPLACED BATTERY PACK , OPS TESTED GOOD IAW AMM 33-51-06-960-802, REV.82.SDR CALA2017103003860Light · inoperativeDOOR SLIDE/OVERWING LIGHT INOP. R&R 3R SLIDE/OVERWING LIGHT BULB REF AMM 33-51-04 OPS OK.SDR CALA2017072802410Battery Pack · dischargedEMERGENCY LIGHTS ON PARTITION SEPARATING BUSINESS FROM COACH ARE INOP, LT AND RT LIGHTS. REPLACED BATTERY SUPPLY OPS CHECK GOOD REF AMM 33-51-06-960-802 INSPECTED REPLACED BATTERY SUPPLY OPS CHECK GOOD REF AMM 33-51-0.SDR CALA2017072802409Wire Harness · faultyALL EMERGENCY FLOOR PROXIMITY LIGHTS INOP IN BUSINESS-FIRST ROWS 8 THRU 10 BOTH AISLES. WIRE HARNESS REPLACED AND EMERGENCY LIGHTS TEXT NORMAL PER AMM TASK 33-51-00-710-801.SDR CALA2017072802408Light · brokenEMERGENCY AISLE LIGHT ON CLASS DIVIDER BEHIND SEAT 2H BROKEN. BOTH LIGHT ASSY REPLACED DUE TO LENS DAMAGE. OPS NORMAL AFTER REPLACEMENT.SDR CALA2017072802407Light · broken2 EACH EMER EXIT LIGHTS BROKEN ON CENTER CLASS DIVIDER AFT OF SEAT ROW 10 PROXIMITY LIGHT . INSTALLED NEW LENS ASSEMBLY 1 EA AND REPLACED 1 LIGHT ASSEMBLY IN CENTER CLASS DIVIDER. OPS CHECK GOOD. REF AMM33-51-05-960-80 2. VERIFIED INSTALLED 1 EA NEW LENS ASSSDR CALA2017062601990Shutoff Valve · faultyUNWANTED FUEL TRANSFER FROM THE CENTER TANK TO THE LEFT, LEFT TANK INCREASES WITH THE CTR PUMPS ON. WHEN CENTER PUMPS OFF THE LEFT TANK QTY DECREASES AND THE CENTER TANK INCREASES. IAW FIM28-220-00-810-849: REPLACED LT TANK OUTLET FLOAT OPERATED SOV IAW AMM28-SDR CALA2017060901764Fuse · faultyBUSINESS CLASS EMERGENCY LIGHTS ON SEATS AND DOOR EXIT EMERGENCY LIGHTS INOP. REPLACED POWER SUPPLY FUSE. OPS CHECK PASSED. REF FIM 33-51-00-8 10-805, WDM 33-51-58 AND SSM 33-51-13.SDR CALA2017012000131Skin · dentedTWO DENTS AND ONE EXISTING BLEND OUT FOUND ON THE EXISTING DOUBLER OUTER SKIN AT BS680 STR-29R. A DENT WAS CLOSE TO EXISTING DENT LP-3305951. EXISTING DBLR REMOVED AND NEW DOUBLER INSTALLED PER SRM 53-00-01, REPAIR-7, HFEC INSP CARRIED OUT AND NO OTHER DMG NOTSDR CALA2017011600114Light · brokenFOUND ZONE "A" PARTITION LT & RT EMERGENCY LT BROKEN. REPLACED ZONE A PARTITION LT & RT EMERGENCY LIGHT AND CARRY OUT OP TEST FOUND ''SATIS'' REF TO AMM 33-51-05-960-802 REV 78.SDR CALA2017011600113Light · brokenZONE B PARTITION LT & RT EMERGENCY LT BROKEN. REPLACED ZONE B PARTITION LT & RT EMERGENCY LIGHT AND OP TEST CARRIED OUT FOUND NORMAL AS PER AMM 33-51-0 6-960-802 REV 78.SDR CALA2017011300100Battery Pack · no testAFT EMERGENCY LIGHT BATTERY PACK FAILED CAPACITY CHECK. REPLACED THE BATTERY PACKS. OPS TESTED OK IAW AMM 33-51-06-960-802 REV.78.SDR CALA2017011300099Light · inoperativeONE SEAT EMERGENCY LIGHT FOUND INOPERATIVE. REPLACED SEAT 29D EMERGENCY LIGHT AND OPS TESTED OK IAW AMM 33-51-05-960-802 REV.78.SDR CALA2017011300098Light · inoperativeONE CEILING EMERGENCY LIGHT FOUND INOPERATIVE. REPLACED THE LIGHT AND OPS TESTED OK IAW AMM 33-51-03-960-801 REV.78.SDR CALA2016040795257Wire · brokenFOUND BROKEN WIRE UNDER SEAT 27G DURING EMER LIGHT CHECK, SPLICED WIRE. PERFORMED OPERATIONS CHECK, CHECKED GOOD IAW SWPM 20-10-13.SDR CALA2015120894863Battery Pack · dischargedDURING EMER LIGHT CHECK, FOUND LOWER SEAT LIGHTS INOPERATIVE, FROM ROW 19 - 31, BOTH LT & RT SIDES. REPLACED BATTERY PACK & POWER PACK IAW AMM 33-51-06. OPERATIONS CHECKED GOOD.SDR CALA2015070694044Battery Pack · dischargedEMERGENCY PATH LIGHTING INOPERATIVE AT ROWS 8D, 9D, 10D, 8H, 9H & 10H. R & R LIGHTING BATTERY PACK PN D717-01-100, SN 165947 IAW AMM 33-51-06. OPERATIONS CHECKED NORMAL.SDR CALA2013112093118Strip · damagedNR 2 GAP STRIP HAS DAMAGE APPROXIMATELY 3 INCHES INBD FROM EDGE ON NR 1 ENG. FOUND SMALL NICK, BLENDED DAMAGE NEEDS TO HAVE HFEC INSPECTION IAW SRM 54-50-70. ACCOMPLISHED HFEC IAW NDT MANUAL PART 6 51-00-06, NO CRACKS FOUND, IAW SRM 54-50-70. DAMAGED AREA IS SDR CALA2013112093116Smoke Detector · failedDETECTOR CHANNEL 1 AFT CARGO COMPARTMENT SMOKE DETECTOR FAILURE. FAN 1 OF THE LOWER AFT DETECTOR HAS FAILED ONLY. MEL CARD CHANGED TO REFLECT THIS CONDITION. REPLACED NR 1 SMOKE DETECTOR FAN IN AFT CARGO PIT IAW MM 26-16-02 DO SYSTEM TEST ON MAT PASSED & MESDR CALA2013111592959Pawl · defectiveGASPER PANEL HANGING FROM PSU AT 21DEG. SECURED GASPER AIR OUTLETS IAW MEL REQUIREMENTS. REPLACED LOCK PAWLS AT PSU AIR NOZZLE PANEL.SDR CALA2013110492573Pivot · damagedRT HORIZONTAL STABILIZER PIVOT PIN HAS DAMAGED THREAD. THREADS REPAIRED IAW ECRA 5510-02339, PN 182W6401-303.SDR CALA2013101892174Probe · intermittentLT MAIN TANK UNIT 12L M28085 SIGNAL IS OUT OF RANGE. IT HAS BEEN HIT INTERMITTENTLY DURING LEGS 2, 9, 12 & 16. REPLACED LT MAIN TANK UNIT 12L PROBE.SDR CALA2013101892175Indicator · faultyIAW EQ4836 TANK UNIT CTR LT NR 8 M28154 IS OPEN OR SHORTED. FAULT OCCURRED INTERMITTENTLY LEGS 8, 15, 19 & 21. CTR TANK INDICATION INOPERATIVE PARTS 483-2010 5041KTU01TANK.SDR UALA2013071004801Pcu · faultyFLIGHT CONTROL SYSTEM STATUS MESSAGE 27-10306, FLAPPER ON POWER CONTROL UNIT RT INBD BYPASS SOLENOID OPERATED, VALVE IS NOT IN COMMANDED POSITION. TROUBLESHOT IAW FIM 27-11, TASK 906. WIRING CHECK FOUND BYPASS SOILENOID OPEN CIRCUIT. REPLACED RT INBD FLAPERSDR UALA2013060703986Connector · damagedNR 1 ENGINE HYD EDP HAS DAMAGED ELECTRICAL CONNECTOR. REPLACED CONNECTOR IAW SWP20-24-20 & WDM 29-11-71.SDR UALA2013060703985Clamp · deterioratedNR 1 ENGINE FAN AIR MODULATING VALVE HARNESS HAS SIX DETERIORATED CLAMP CUSHIONS. REPLACED SIX CLAMPS.SDR UALA2013041802688Speaker · faultyCAPTAIN'S AUDIO SPEAKER HAS RATTLE AND INAUDIBLE. REPLACED CAPTAINS SPEAKER, AUDIO OPS NORMAL AT THIS TIME.SDR UALA2013022101042Warning System · activatedSTATUS MESSAGE FLIGHT CONTROL SYS WITH FLIGHT CONTROL MODE CAUTION MESSAGE. MAINT MESSAGE 27-15101 LATCHED IN MAT. CORRELATED STATUS MESSAGES ARE (SAARU.AUTO SPEED BRAKE, THRUST ASYM COMP AND NO AUTOLAND). REPLACED CENTER PSA PER MM, NO HELP. RE-INSTALLED OSDR UALA2012121007158O-Ring · leakingNR 2 FUEL SERVO BYPASS POPPET LEAKING. REPLACED POPPET O-RING. LEAK CHECK GOOD.SDR UALA2012110906447Wire Harness · damagedNR 2 ENGINE RIGHT STATUS MESSAGE. FOUND WIRES W0656-1001R-16 AND W0656-1002R-16 FROM M26005 LOWER AFT FIRE DETECTOR TO M26004 LOWER FORWARD WITH DAMAGED INSULATION BENEATH CLAMPS BEHIND EDP HYDRAULIC SUPPLY LINE HEATSHIELD AT 3 O'CLOCK POSITION. REPLACED FIRSDR UALA2012110906446Wire · damagedSTATUS MSG OVERHEAT CIRCUIT R2. FOUND WIRES W0656-1001R-16 AND W0656-1002R-16 FROM M26005 LWR AFT DETECTOR TO M26004 LOWER FWD WITH DAMAGED INSULATION BENEATH CLAMPS BEHIND EDP HYDRAULIC SUPPLY LINE HEATSHIELD AT THE 3 O'CLOCK POSITION. REPROTECTED INSULATIOSDR UALA2012101505846Bulb · inoperativeEMERGENCY EXIT SIGN ON AISLE NEAR R2 DOOR, GALLEY, ONE BULB INOPERATIVE. REPLACED BULB AND OPS CHECKED OKAY PER MM.SDR UALA2012091105098Unknown · malfunctionedCENTER TANK RT REFUEL VALVE ACTUATOR CLOSED DURING REFUELING. DF FOR BASE ACTION. -INF- :TRIED NEW IRP NO HELP. RE-INSTALLED OLD IRP, NEEDS MORE TROUBLESHOOTING. REPLACED REFUEL VALVE CONTROL UNIT, NO HELP.SDR UALA2012082704779Satcom · faultySAT SYSTEM STATUS MESSAGE DISPLAY, RESET SYSTEM THREE TIMES, NO HELP. NEED SDU PCN 583-9200. REPLACED SDU PER MM, NO STATUS MESSAGE. FOUND SATCOM LINK TEST NORMAL.SDR UALA2012060803153Battery Pack · inoperativeNR 3R DOOR FWD EMERGENCY EXIT LIGHT INOP REF JC 2-2025C. REPLACED BATTERY PACK.SDR UALA2012060803152Battery Pack · faultyR3 DOOR EMERGENCY EXIT UPPER LIGHT INOPERATIVE REF JC 2-2025C. REPLACED EMERGENCY BATTERY PACK ASSY.SDR UALA2012051002675Monitor · faultySTATUS MESSAGE WAI CARD REPEAT GRIPE. TRIED TO RESET WAI CARD, NO HELP. UNABLE TO RUN WAI SYSTEM TEST VIA MAT. CAN NOT COMMUNICATE WITH CARD. SUSPECT BAD ACIPS OR LINEAR MONITOR (A3) AT P84. NO TIME TO FURTHER TROUBLESHOT, BOTH WAI VALVES DEACTIVATED. SDR UALA2012032201838Heat Shield · damagedHEATSHIELD SET INSTALLED ON THE NR 1 POSITION WAS LINE REPAIRED, NOT HEAT TREATED OR FLAME SPRAYED. HEAT SHIELDS REPAIRED IAW ECRA 5454-01037. HEAT SHIELDS REPAIRED IAW ECRA 5450-01902.SDR UALA2012032201834Skin · dentedTWO DENTS WERE FOUND ON OUTER SKIN OF LT FUSELAGE STA 676 TO STA 697, S26L TO S27L. CATEGORY B REPAIR ACP IAW SRM 53-00-01 REPAIR 7 (PAGE 109-127 OF 210).SDR UALA2012032001811Skin · damagedCATEGORY 'B' REPAIR ACP IAW SRM 53-0-01 REPAIR 7 (PAGE 109-127 OF 210). ZONE B INSP THRESHOLD IS 30,000 CYCLES WITH INSP INTERVAL OF 16,000 CYCLES. EXT FUSE SKIN AT STA 676 TO 697 S26L TO S27L DAMAGE REMOVED IAW SRM 53-00-01 REPAIR 7. HOLES NOT ZERO TIMED. SDR UALA2012031901767Spar · corrodedLT WING REAR SPAR WEB CORROSION AROUND FASTENERS BETWEEN IRSS 340 AND IRSS 350 WHERE FUEL BOOST PUMP IS INSTALLED. REF 777EN-57-0300. BLEND OUT REPAIR ACP IAW ECRA 5720-02267.SDR UALA2012031901766Spar · corrodedRT WING REAR SPAR WEB CORROSION AROUND FASTENERS BETWEEN IRSS 340 AND IRSS 350 WHERE FUEL BOOST PUMP IS INSTALLED. REF 777EN-57-0299. BLEND OUT REPAIR ACP IAW ECRA 5720-02266.SDR UALA2012021400885Structure · leakingLEFT WING FUEL LEAK, FLIGHT DIVERTED. FUEL LEAKING FROM LT & RT WING BET LDG GR AND PYLON, DENTNK ENTRY CREW FOUND LT WING LEAKING, REPAIR IN PROGRESS WILL SEAL LT IN MORNING AND START RT LEAK. BOTH WING LEAKS ARE SEALED AND CURING.SDR UALA2012013000607Wire · damagedREF WDM 24-21-21 PG 1 SHT 2, FOUND DAMAGED WIRE W8201-0002-02, AT TS33001. NEED NEW LUG INSTALLED AND WIRE SPLICED IN. SAMC TEXT: REF BSPWM 20-30-13 & 20-10-13, OK TO ACP SPLICE RPR IN PYLON AREA ON DAMAGED FEEDER WIRE. STARTED RMV'G WIRE FROM TERM BLOCK THRSDR UALA2012013000578Clamp · looseNR 2 ENG FEEDER CABLES INSIDE PYLON ABOVE ENGINE LOOSENED (ALL CLAMPS AND STAND OFFS IN TOP PYLON). STARTED SECURING FEEDER CABLES INSIDE OF PYLON 4EA UPPER CLAMPS, 2 LOWER CLAMPS STILL LOOSE AND FIREWALL FEED THRU NEEDS SEALED WHEN WORK COMPLETED.