What was found
STATUS MSG OVERHEAT CIRCUIT R2. FOUND WIRES W0656-1001R-16 AND W0656-1002R-16 FROM M26005 LWR AFT DETECTOR TO M26004 LOWER FWD WITH DAMAGED INSULATION BENEATH CLAMPS BEHIND EDP HYDRAULIC SUPPLY LINE HEATSHIELD AT THE 3 O'CLOCK POSITION. REPROTECTED INSULATION PER GNMM 2-0-15-001 AS PRECAUTION, HOWEVER WILL REQUIRE WIRES REPLACEMENT. CLAMPS PCN 754-2529 (05EA) ARE WORN AND MUST ALSO BE REPLACED 141596. (PARTS: 754-2529 TA025115-04 CLAMP)