N788UA
Service difficulty reports · 191
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N788UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N788UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2012020700726Light · inoperativeAISLE STAND FLOOD LIGHT(S) - DO NOT COME ON. REPLACED LAMP AS PER AMM, OKAY.SDR UALA2012020300671Unknown · malfunctionedAPU NO START AFTER LANDING, SHOWED MAINT MSG 49-1 1290. PER FIM49-52T808 TRIED TO START APU WITH EXTERNAL PNEUMATIC SOURCE. NO HELP. APU ONLY REACHING ABOUT 25% AND 450EGT BEFORE AUTO SHUT DOWN OCCURS. CYCLED APUC C-B S AMIS C-B S & INSPECTED APU CHECK VALVSDR UALA2012012500534Sense Line · faultyREMOVED NR 2 ENG HPSOV CONTROL PRESSURE SENSE LINE FOR ACCESS. REPLACED SENSE LINE.SDR UALA2012012500533Bolt · shearedREMOVED NR 2 ENG HPSOV PER MM FOR ACCESS TO SHEARED BOLTS. REPLACED HPSOV.SDR UALA2012012500524Bolt · brokenREF WG6601. WHILE REMOVING SUPPORT BRACKET ON AP41 TUBE, 2 EACH BOLT HEADS BROKE OFF ON DIFFUSER CASE. BROKEN BOLTS EXTRACTED BY MACHINIST.SDR UALA2012012400498Bolt · shearedNR 2 ENG REF EG6601 HPT HUB BORESCOPE FOR SLIGHT HOC. REMOVED 5 EA BOLTS FROM LOWER AP41 LINE. NEED TO CONT REMOVING 1 EA BOLT AND 4EA NUTS, CLAMP 792 (MIDSPAN, 4EA BOLTS THAT CONNECT AP41 TO TURBINE COOLING VLV. SPRAYED CLAMP BOLTS WITH PENETRANT TO LOOSENSDR UALA2012010600138Line · leakingOIL LEAK RT ENGINE OIL POOLING ON EXHAUST COWLING. TIGHTENED PRESSURE LINE ON NT 4 BEARING STRAINER ASSY. TIGHTENED PRESSURE LINE ON NR 4 BEARING STRAINER ASSY.SDR UALA2011121906991Unknown · malfunctionedFUEL IMBALANCE EICAS, RTFL. AFTER AN HOUR FLT TIME FUEL IMBAL EICAS DUE TO LEFT TANK AT 68.1 COMPARED TO RIGHT AT 65.1. LEFT CLIMBED TO 68.9 THEN QUICKLY DROPPED TO 66 AND CLIMBED AGAIN TO 68.9. SAMC TEXT: TOT AND CALC WERE 1100 LBS DIFFERENT. TOT LESS THSDR UALA2011120206638Heat Shield · damagedHEATSHIELD DAMAGE AT NR 2 ENG. DEACTIVATED LEADING EDGE SLATS, IAW REF AMM27-81-00 PG 201. ACCOMPLISHED REACTIVATION.SDR UALA2011111806332Shutoff Valve · leakingHYDRAULIC FLUID LEAKING FROM CENTER HYDRAULIC SYSTEM TAIL SHUTOFF VALVE. REPLACED CTR HYD SYS TAIL SHUTOFF VLV PER AMM. NEW VLV LEAKING AT INBD UNION TO V VLV BODY CONNECTION. REPLACED SHUTOFF VLV AGAIN AND ALSO INBD UNION PER AMM. NO LEAKS AND TEST NORMALSDR UALA2011110906094Seal · damagedWATER LEAKING ABOVE DOOR 3L AT 40 DROPS PER MIN. APPEARS TO BE COMING FROM THE HGA PORT L M23093 CONNECTOR. FOUND AREA OF SEALANT ON THE UPPER EDGE OF ANTENNA MISSING, SCRAPED AREA, RESEALED UPPER EDGE & APPLIED TAPE OVER AREA OF SEALANT. ACP A REPAIR WITHISDR UALA2011101705620Engine · out of toleranceNR 1 ENG HOC. DUE TO CHRONIC HISTORY OF HOC & OIL GULPING REPLACE NR 1 ENGINE.SDR UALA2011092005061Windshield · delaminatedCAPT WINDSHIELD HAS 2 INCH BY 4 INCH DELAMINATION. REPLACED CAPTAINS NR 1 WINDOW PER MM. PERFORMED WINDOW ANTI-ICE TEST PER MM. OK FOR SERVICE.SDR UALA2011090704856Gearbox · leakingNR 1 ENG ECM MONITORING SHOWING INCREASED OIL CONSUMPTION. REFER TO FIM 71-05 TASK 830 AND PERFORM ENGINE CHECK NR 7-OIL LEAKS PER FIM 71-08 TASK 819 PAYING PARTICULAR ATTENTION TO RECENT DISTURBED COMPONENTS: OIL TANK & LINES (REMOVED FOR AIR SHIP), ANGLE GSDR UALA2011090504783Circuit Breaker · faultyNR 2 ENG VIB IND BLANK. MAINT MSG IS 77-08862. PLZ WORK WITH LM1628 CB P210 E6 RESET AND IDLE OPS CK. IF TEST OK, DO NOT WAIT FOR CH1982, BUT GO AHEAD AND MAKE R ENG VIB SYS OPERATIONAL IMMEDIATELY AND CLEAR THIS DF791. RVWD W OPBLM-EMC DEEDS, UNITS IN IAD & SDR UALA2011090604818Brake · faultyREPLACE NR 6 MLG BRAKE ASSY DUE TO HIGH ENERGY STOP. REPLACED NR 6 MLG BRAKE.SDR UALA2011090604817Brake · faultyREPLACE NR 5 MLG BRAKE ASSY DUE TO HIGH ENERGY STOP. REPLACED NR 5 BRAKE ASSY IAW MM.SDR UALA2011090604816Brake · faultyREPLACE NR 2 MLG BRAKE ASSY DUE TO HIGH ENERGY STOP. REPLACED NR 2 BRAKE ASSY IAW MM.SDR UALA2011090604815Brake · faultyREPLACE NR 1 MLG BRAKE ASSY DUE TO HIGH ENERGY STOP. REPLACED NR 1 MLG BRAKE.SDR UALA2011090604814Brake · faultyREPLACED NR 10 MLG BRAKE ASSY DUE TO HIGH ENERGY STOP. REPLACE NR 10 MLG BRAKE ASSY DUE TO HIGH ENERGY STOP IAW MM 5-51-14-201.SDR UALA2011090604813Brake · faultyHIGH ENERGY STOP. REPLACED NR 9 MLG BRAKE ASSY DUE TO HIGH ENERGY STOP. REPLACED NR 9 MLG BRAKE PER MM.SDR UALA2011083104670Engine · fireNR 1 ENG SHUTDOWN, RTFL. HIGH EGT ON NR 1 ENG. F/D REPORTED FIRE ON RT GEAR TRUCK ASSY & LT TRUCK OVERHEATED. BRAKE FIRE INSP NEEDED. MOVING A/C TO REMOTE WILL START WORK. REPLACED NR 1 ENGINE.SDR UALA2011082904617Filter Element · faultyENG OIL FILTER R RIGHT ENGINE PRIMARY OIL FILTER APPROACHES BYPASS (LARGE PRESSURE DIFFERENTIAL ACROSS NORMAL FILTER) WITH ENGINE RUNNING. STATUS CREW COMMENTS: RIGHT ENGINE OIL FILTER ADVISORY MSG-7962312 INACTV TA MODE. FIM 71-05 TASK 835, GOT MAT MSG 79-SDR UALA2011053102653Connector · unsecureEMERGENCY FLOOR PROXIMITY LIGHT AT SEAT 20D IS INOPERATIVE. SECURED CONNECTOR. OPS CHECKED GOOD.SDR UALA2011053102654Light · inoperativeEMERGENCY FLOOR PROXIMITY LIGHT AT SEAT 1H IS INOP. FWD LIGHT. RELAMPED, NO HELP. TRIED NEW LIGHT ASSY, NO HELP.SDR UALA2011042902086Data Box · inoperativeSATCOM SYSTEM SATCOM SYSTEM FAILS OR NO BUSS ACTIVITY. STATUS MESSAGE 01- ACTIVE CRUISE HARD; SATELLITE DATA UNIT (LEFT) HAS NO OUTPUT ON ANY BUSS. MSG-2368801 ACTIVE ER HARD. RESET CB'S TO TEST SATCOM UNIT. NO SATCOM LEGEND INDICATED ON FMC. REPLACED SDU.SDR UALA2011042501977Power Supply · inoperativeOVERHEAD EMERGENCY EXIT LIGHT AT DOOR 2R IS INOP. REPLACED ALL 16 LAMPS, NO HELP. REPLACED EMERGENCY POWER SUPPLY M33097. OPS CHECKS GOOD.SDR UALA2011041801856Printer · odorCABIN PRINTER AT DOOR NR 2 BURNING SMELL. CONFIRMED BURNING SMELL COMING OUT FROM INSIDE OFF THE PRINTER. REMOVED AND REPLACED PAC PRINTER RD-FA1161-01 SN ON 08G0002 SN OFF 10G0036. CHECKED WIRE HARNESS BEHIND PRINTER, NO DEFECTS NOTED. NEW PRINTER OPS CHESDR UALA2011032801487Pump · faultyFUEL BURNED OUT OF LEFT TANK W CTR PUMPS ON. 3800 LB IMBAL DEVELOPED. SAMC TEXT: FUEL BURN OUT OF LT MAIN TANK W CTR PUMPS ON. 3800 IMBAL. CREW BALANCED IT THEN RESTORED TO NORMAL OPS. FUEL KEPT PUMPING FROM LT TANK W CTR PUMPS ON UNTIL LT MAIN PUMPS SELECTSDR UALA2011032101364Pump · faultyA 4000 LB LATERAL FUEL IMBALANCE. SAMC TEXT: IAD MM ON ARRIVAL AND BEFORE REFUELING ACCOMPLISH A DRIP OF THE MAIN TANKS TO CONFIRM QUANTITY READINGS. TESTED PER MM. TEST PASSED. LEFT CENTER PUMP PRESSURE LIGHT ILLUMINATED AT 2300 LBS. REPLACED LEFT CENTER SDR UALA2011031601282Wire · disconnectedALL EMERGENCY LIGHTS ZONE 2 AFT INOPERATIVE. FOUND WIRING OUT OF DISCONNECT AT SEAT 9H AND 10C SEAT LIGHT DISCONNECTED AND 10C FOOT GRD WIRE PULLED OUT OF CONNECTOR. REPAIRED WIRING, SYSTEM CHECKED OK.SDR UALA2011030401058Processor · malfunctionedFUEL IMBALANCE LT AND RT MAIN TANK QUANTITIES DIFFER BY A PRE-DETERMINED AMOUNT. 3700 LB IMBALANCE. BALANCED FUEL BY CHECKLIST. ALL SYS NORMAL. CREW REPORTED THE IMBALANCE OCCURRED AFTER THE FUEL WAS USED FROM THE CENTER TANK. THE RT WING WAS LOWER THAN LEFT SDR UALA2011030401057Bulb · defectiveSMOKE FROM LWR CREW REST READING LIGHT ASSY. NR 5 BUNK HAD DEFECTIVE BULB THAT APPEARS TO HAVE CAUSED PROBLEM. ALL LWR REST READ LIGHT BULBS REMOVED. ACCOMPLISHED CHECK PER EVA 80640. BULBS WERE ALREADY REMOVED, UNABLE TO ROUTE REMOVED BULBS TO SFOEG FITZPSDR UALA2010111604249Connector · brokenUPPER EICAS MESSAGE 'SMOKE CREW REST F-D' CAUTION MESSAGE DISPLAYED. NEW OEU, NO HELP, NEW SMOKE DET, NO HELP. DISCONNECTED D11037P, NO HELP. DISCONNECTED K26013 AND K26012, NO HELP. NO EXISTING FAULT ON MAT. PIN 10 OF SMOKE DETECTOR SHOWS 28 VDC WHICH INDSDR UALA2010111504234Battery · faultySTATUS MSG FLIGHT CONTROL SYSTEM. REPLACED RIGHT FLIGHT CONTROL BATTERY. MESSAGE WENT AWAY, NOT ACTIVE ON MAT.SDR UALA2010083003201Light · missingEMERGENCY LIGHT MISSING AT SEAT 3F. REPLACED AFT EMERGENCY SEAT LIGHT 3F. CHECKS OK.SDR UALA2010082503132Feeder Cable · brokenAPU GENERATOR INOPERATIVE. REPLACED APU GCU, NO HELP. ACTIVE MESSAGE ELECTRICAL GENERATOR OFF APU. MAINT MESSAGE 24-31713. FOUND TERMINAL END AT GENERATOR SIDE IS BROKEN. WIRING NR IS W7860-0002-3 (T2 WIRE LEAD). REPLACED APU FEEDER CABLES (T1,T2,T3 AND N) ASDR UALA2010022400679Wire · shortedEICAS STATUS MESSAGE DET CHAN 1 CARGO AFT, FOUND AFTER ACFT RELEASE. TROUBLESHOT AND FOUND WIRE NR W4263-2020B-24 SHORTED TO SHIELD, (GROUND). REPAIRED WIRE WITH SPLICE KIT (D150-0174). PERFORMED OPERATIONAL CHECK OF AFT CARGO COMPARTMENT SMOKE DETECTION SYSDR UALA2010021900625Slide · reads lowDOOR 2 RT SLIDE RAFT PRESSURE LOW. REMOVED 2R SLIDE PACK. INSTALLED SLIDE 2RT PER MM TO COMPLETION.SDR UALA2010021600601Heat Shield · damagedRIGHT ENGINE COWL HEAT SHIELD MISSING. RT ENG THRUST REVERSER THERMAL INSULATION BLANKET LEFT SIDE DAMAGE SIZE IS 25 INCH BY 25 INCH. REPLACED THRUST REVERSER THERMAL INSULATION BLANKET ASSY.SDR UALA2010020800481Lamp · inoperativeEMERGENCY LIGHT AT SEAT 3F AFT INOPERATIVE. REPLACED LAMP ASSY, OPS CHECK NORMAL.SDR UALA2010012600320Anti-Ice Valve · faultyANTI-ICE WING FAILURE OF RT OR LT WING VALVE IN THE CLOSED POSITION, OR WAI AIR TEMPERATURE LESS THAN 200 DEGREES F AND WAI SWITCH IN EITHER THE ON POSITION OR THE AUTO POSITION WITH ICING CONDITIONS DETECTED, OR FAILURE OF WAI CONTROL CARD, OR SYS FAILS CLOSESDR UALA2010011300170Compressor · stalledLEFT ENGINE COMPRESSOR STALLED AT FL380. LT ENGINE COMPRESSOR STALL FL380 AT OFF PULLED POWER BACK ENG RECOV -MSG 71-60431 FOUND NOT ACTIVE ON ARRIVAL. REVIEWED EXCEEDENCE PAGES ON EPCS NO EXCEEDENCE RECORDED. CARRIED OUT INSP OF INLET AND EXHAUST NO DEFECTSSDR UALA2009121503884Valve · malfunctionedAPU BLEED AIR MSG. REPLACED SURGE VALVE. OPS NORMAL.SDR UALA2009120403753Fan Blade · bentON ARRIVAL FOUND LEFT ENG FAN BLADE NR 18, NR 19 LEADING EDGE BENT DAMAGED BY FOREIGN OBJECT. CHECK FOUND ACOUSTIC LINERS HAVE DAMAGE TO AFT FAN EXIT GUIDE VANE ABOUT 9 O'CLOCK POSITION. REPLACED NR 1 ENG NR 18 & 19 BLADES. EMC WRKG ON EVA FOR INT REPAIR TOSDR UALA2009111703583Valve · malfunctionedLEFT PACK SHUT DOWN ON GATE WITH LEFT PACK EICAS MSG MULTIPLE RESETS. REPLACED LT UPPER FLOW CONTROL VALVE, OPS CHECKS NORMAL.SDR UALA2009111603547Precooler · crackedNR 1 ENG FAILED DUCT LEAK TEST. FOUND LARGE CRACK ON NR 1 ENG PRECOOLER. REPLACED PRECOOLER. AFT PRECOOLER CLAMP LEAKING AT HINGE POINTS. RE-SECURED, SECURED ENGINE COWLS.SDR UALA2009103003393Light · missingSEAT 2E SEAT MOUNTED EMER LIGHT MISSING. REPLACED EMERGENCY LIGHT. OP CHECKED OKAY.SDR UALA2009090402794Light · damagedSEAT 1E AISLE EEL LIGHT DAMAGED. REPLACED EEL LIGHT. OPERATION CHECKS OKAY.SDR UALA2009062901858Start Valve · defectiveENG START VALVE RIGHT STARTER AIR VALVE POSITION DISAGREES WITH COMMANDED POSITION. ADVISORY - MANUAL START REQUIRED. START VALVE SLOW TO OPERATE. WILL REQUIRE START VALVE. REPLACED STARTER AIR VALVE, OPS CHECKED OKAY.
Back to N788UA