N788UA
Service difficulty reports · 191
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N788UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N788UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2009060901639Pressure Switch · malfunctionedLT ENG FUEL PUMP FILTER MSG. RTFL. REPLACED FUEL PUMP FILTER PRECAUTIONARY AND REPLACED FUEL PUMP DIFFERENTIAL PRESSURE SWITCH. RAN ENGINE AND VERIFIED NO MESSAGE OR LEAKS. OLD FUEL FILTER NO CONTAMINATION, REPLACED PRECAUTIONARY.SDR UALA2009060201586Valve · damagedBLEED ENG L EICAS MSG. RTFL. FOUND SHAFT SHEARED. REPLACED HP VALVE, OPS CHECK OKAY.SDR UALA2009040300955Light · inoperativeSEAT 1F 1 EACH EEL INOP. REPLACED EEL STRIP, CHECK OK.SDR UALA2009040300954Light · inoperativeSEAT 1E 1 EACH EEL LIGHT INOP. REPLACED EEL STRIP, CHECK OK.SDR UALA2009022300613Wire Harness · shortedR ENG STATUS MSG R REVERSER. CHECK LT RVDT (M78002) RESISTANCE CHECK WITHIN RANGE. CHECK EEC HARNESS W604 WITH A MEGGAR AT CONN DM73003N PIN NR 3, 12, 11, 26 ALL SHORT TO GRD. REPLACED W0604 HARNESS. OP CHECK NR 2 ENG REV. OP CHECK GOOD, NO MSG.SDR UALA2009020900420Floorbeam · damagedFLOORBEAM AT STA 972 HAS DAMAGE DUE TO BURNED C2 PUMP FEEDER CABLES. RECEIVED REPAIR METAL 2030 (TITANIUM & ALUMINUM PLATE). ROUTE TO SHOP FOR REPAIR ANGLE MFG. REMOVED DAMAGE AND INSTALLED REPAIR.SDR UALA2009020400386Feeder Cable · faultyCTR HYD SYSTEM ELECTRIC PUMP C2 INOP. NEW P200 PANEL IS INSTALLED. AWAITING CONNECTOR. FOUND BURNED POWER FEEDER CABLES IN FWD PIT CEILING AT STA 972. REPAIRED AS PER GNMM STANDARD ELEC PRACTICES. C2 ELEC PUMP CK'S NORMAL.SDR UALA2009012700301Connector · unsecureEMERGENCY EXIT EEL LIGHT INOP AT SEAT 3F AFT LIGHT ASSY. SECURED CONNECTOR, OPS CHECKS NORMAL.SDR UALA2009012700300Connector · looseEMERGENCY EXIT EEL LIGHTS INOP AT SEAT 1E BOTH FWD AND AFT LIGHT ASSY'S. SECURED CONNECTOR. OPS CHECKS NORMAL.SDR UALA2009012700299Lamp · inoperativeEMERGENCY EXIT LIGHT INOP AT LAV 133 LOWER OUTBOARD LIGHT. RELAMPED EMERGENCY LIGHT, OPS NORMAL.SDR UALA2009012700298Light · inoperativeEMERGENCY EXIT LIGHT INOP AT SEAT 18G. RELAMPED EMERGENCY LIGHT, OPS NORMAL.SDR UALA2009012700297Light · inoperativeEMERGENCY EXIT EEL LIGHT INOP AT SEAT 3E AFT LIGHT ASSY. REPLACED LIGHT ASSY, OPS CHECKS NORMAL.SDR UALA2008121606905Sensor · failedENG EEC C1 R RIGHT ENGINE CONTROL IS IN A TIME LIMITED DISPATCH CONDITION. ENGINE CONTROL SYSTEM IS OPERATING WITH REDUCED REDUNDANCY. STATUS FOUND MSG NR 79-60842. REPLACED R ENG OIL TEMP SENSOR.SDR 2008UALA06435Light · inoperativeSEATS 1E AFT, 2E BOTH AND 1F FWD EEL LIGHTS INOP. REPAIRED 1E AND 1F. CURRENTLY 2E EEL LIGHTS STILL INOP. NEED INVERTER LOCATED ON 3E STOWAGE BOX.SDR 2008UALA06089Battery · faultySTATUS MESSAGE "MAIN BATTERY". REPLACED & OP CHECKED MAIN BATTERY. MESSAGE CLEARED. BATTERY INDICATIONS NORMAL.
SDR 2008UALA04304Fire Detector · failedFIRE LOOP 1 ENG R RIGHT ENGINE FIRE DETECTION SYSTEM LOOP 1 FAILURE. *S/D* REPLACED RIGHT ENGINE UPPER FIRE LOOP. FIRE TEST PASSED.SDR 2008UALA03366Isolation Valve · faultyL BLEED ISOLATION VALVE FAULT. SUSPECT FAULTY ISOLATION VALVE. REPLACED LT ISOLATION VALVE PER MM 36-12-01. AC OK FOR SERVICE.SDR 2008UALA01591Light · inoperativeDOOR 3L THRESHOLD LIGHT IS INOP.SDR 2008UALA01003Toilet · leakingFLIGHT DIVERTED DUE TO WATER LEAK/OVERFLOW FROM DOOR 3 LAVATORY COMPLEX. FOUND FAULTY WATER VALVE. REPLACED TOILET. TEST SYSTEM OPS NORMAL NO LEAKS. ACFT OK FOR SERVICE.SDR 2008UALA01001Hose · failedFLIGHT LANDED UNDER AMBER ALERT DUE TO A FAILED CENTER HYDRAULIC SYSTEM. NORMAL LANDING, BUT FLIGHT HAD TO BE TOWED TO GATE. FOUND FLEX HOSE TORN BY NOSE STEERING ACTUATOR. REPLACED HOSE. SERVICED HYD SYS. OP CHECKED OK. NO LEAK. ACFT OK FOR SERVICE.SDR 2007UALA05118Converter · faultyRIGHT ENGINE GENERATOR OFF LIGHT CAME ON MOMENTARILY AFTER LIFTOFF. RECURRED ON FLT 0935-15JAN08. REPLACED NR 2 IDG PER MM 24-11-01, RAN ENGINE PER JRH IDG OPS NORMAL GENERATOR OPS LIGHT STILL COMES ON. REPLACED CONVERTER. TEST PASSED. AC OK FOR SERVICE.SDR 2007UALA04870Light · faultyAFT GALLEY LT AFT CEILING LIGHT BLINK. RELAMPED LIGHT.SDR 2006UALA02291Light · missingSEAT 1E REAR EMERGENCY EEL LIGHT MISSING. REPLACED LT ASSY AND PERFO RMED EMERGENCY LT TEST AND OPS NORMAL.SDR 2006UALA02153Light · inoperativeEMERGENCY LIGHTS INOP AT SEATS 18C, 24G AND CENTER LIGHT ON AFT LT GALLEY BULKHEAD. RELAMPED OR REPLACED, LAMP OR LIGHT ASSY AS NEEDED. OPS CK GOOD.SDR 2006UALA01511Lamp · burned outEMERGENCY PATH LIGHT ASSY BROKEN AT SEAT 1E AFT. REPLACED LAMP ASSY. OPS NORMAL.SDR 2006UALA01013Frame · out of limitsFOUND HEAT DAMAGE. THE READING OF THE WEB AND THE BULKHEAD FRAME AT SAF STA 3.62 WERE OUT OF LIMITS. DURING THE ACCOMPLISHMENT OF COA 208490, CONDUCTIVITY TEST FOUND HEAT DAMAGE. THE READING OF THE WEB, 313W3811-13, AND BULKHD, 313W3812-4, AT SAF STA 3.62 WESDR 2006UALA01012Structure · misdrilledA FASTENER HOLE WAS FOUND HAVE FREEZE PLUG AND SHORT EDGE MARGIN FOR MLG WHEEL WELL MOD RT AT STR 36R 2ND FASTENER FROM I/B END. ACCOMPLISHMENT OF SB 777 53A0015, A FASTENER HOLE WAS FOUND TO HAVE A FREEZE PLUG INSERTED AS A REPAIR FOR AN OVERSIZED HOLE. AS SDR 2006UALA00997Shim · migratedFOUND STA 1434, RT KEEL BEAM FITTING, SHIM IS MIGRATED. BS 1434, RH KEEL BEAM FITTING, SHIM IS MIGRATED. REMOVED BROKEN SHIM, ACP HEFC INSP OF HOLES AND SPLICE PLATES FOR CRACK, NO CRACK FOUND. MANUFACTURED SOLID SHIM AND REINSTALL. SHIM MIGRATION TYPICALLY SDR 2006UALA00618Lamp · missingEEL LIGHT AT 39G MISSING. SUPPLEMENTAL DATA UPDATE NSTLD SVCBL ASSY PER MM 33-51-05, OPS CKD PER SAME. SYS OP CHECKED NORMALLY.SDR 2006UALA00092Lamp · inoperativeSEAT 1E AFT EMERGENCY LIGHT INOP.SDR 2005UALA00918Terminal Block · overheatedNR 1 ENGINE UPPER IDG TERMINAL BLOCK HAS MELTED AREAS AND MISSING SHRINK WRAP ON WIRES. THE IDG STRUT DISCONNECT TERMINAL BLOCK INSPECTION/TORQUE CHECK ACCOMPLISHED AT THE SEGMENTED 'A' DISCOVERED THE OVERHEATED TERMINAL BLOCK. REVIEW OF IDG WRITE-UPS, LOGBOSDR 2004UALA00098Support Fitting · brokenDOOR 2L WILL NOT DISARM. ONE OF THE CASTINGS THAT LIFT THE SLIDE GIRT BAR WHEN ACTUATED BY THE DOOR ARM/DISARM LEVER, WAS FOUND BROKEN, PREVENTING THE SLIDE GIRT BAR FROM BEING LIFTED FREE OF THE FLOOR GIRT FITTING. THE FITTING WAS REPLACED AND THE GIRT BAR SDR 2004UALA00096Battery Pack · inoperativeEMERGENCY EXIT CEILING LIGHTS INOP FIRST ROW COACH TO DOOR 3L. REPLACED BATTERY PACK.SDR 2003UALA00412Flap · failedAIRCRAFT HAD FLAP DRIVE FAILURE INVOLVING PRIMARY AND SECONDARY SYSTEMS. CENTER ACE WAS REPLACED AS PRECAUTIONARY. DETAILED TESTS OF FLAP PRI CONTROL VALVE AND FLAP SECODARY MODES PASSED WITH NO FAULTS.SDR 2000UALA00445Brake · overheatedUPON ARRIVAL AT DEN, HOT BRAKES, SMALL FLAMES AND SOME SMOKE REPORTED AT OUTBOARD WHEELS ON RIGHT MAIN LANDING GEAR. FLAMES SELF-EXTINGUISHED WITH NO DAMAGE TO AIRCRAFT. *S/D* UNABLE TO DETERMINE ANY DEFINITIVE CAUSE. LT AND RT MAIN LANDING GEAR WHEEL AND SDR 2000UALA00262Oven · dirtyBURNING SMELL IN GALLEY AREA. CIRCUIT BREAKERS PULLED AND SMELL SUBSIDED. *S/D* PLASTIC FOOD WRAP STUCK IN BACK OF OVEN CAUSING SMELL. REPLACED OVEN.SDR 99UAL900432Clamp · brokenSHORTLY AFTER DEPARTING ORD EN ROUTE LHR, CREW RECEIVED STATUS MESSAGE ON BLEED LOOP NR 1. SUBSEQUENTLY MESSAGE RECEIVED FOR NR 2 BLEED LOOP. AIRCRAFT DIVERTED TO IAD. *S/D* DUCT CLAMP ON RIGHTHAND AC PACK LOWER FLOW CONTROL VALVE (FCV) BROKE, TRIGGERING ASDR 99UAL900376Cacp · overheatedEN ROUTE LHR-IAD, ELECTRICAL ODOR REPORTED IN FLIGHT DECK AND MID GALLEY AREA. AIRCRAFT RETURNED TO LHR. *S/D* INSULATION, (HEAT SHRINK), AT BASE OF LAMPS OVERHEATED. THE OVERHEAT CONDITION IS A KNOWN PROBLEM AND BOEING IS PREPARING A SERVICE BULLETIN AND SDR 99UAL900186Heater · malfunctionedKEROSENE SMELL REPORTED ON GROUND AND ONCE IN CRUISE AROUND DOOR 2L. FLIGHT EN ROUTE EWR-LHR AND DIVERTED TO YQX. *S/D* ACCOMPLISHED IDLE AND HIGH POWER ENGINE RUNS. INSPECTED AND SEARCHED CARGO PITS WITH AIRCRAFT PRESSURIZED AND UNPRESSURIZED, NOTHING FOUSDR 98UAL900252Hf Radio · failedBOTH HIGH FREQUENCY RADIOS FAILED SHORTLY AFTER TAKEOFF. AIRCRAFT RETURNED TO JFK DUE TO INSUFFICIENT ALTERNATIVE ROUTE FUEL.SDR 97UAL900774Oil Syst · reqd serviceAFTER TAKEOFF CLIMBING THROUGH 15000 FT, RIGHT ENGINE INDICATED ONE QUART OF OIL. ENGINE TEMPERATURE AND PRESSURE CONTINUED TO FLUCTUATE. AIRCRAFT RETURNED TO LAX.