N791UA

Service difficulty reports · 188

Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE n_number = 'N791UA' AND registry_match = 'registration'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR UALA2012013000608Check Valve · faultyAPU WOULD NOT START. APU BLEED STATUS THEN APU FAULT, CYCLED NO LUCK. RESTART APU IS GOOD, BUT APU BLEED AIR MSG STAY ON, AIR START. APU STILL NO HELP. DEFER PER MEL. APU ELEC SUPPLY IS GOOD, BUT AIR SUPPLY IS NOT USEABLE. RPLC'D APU CHECK VALVE PER MM. Jan 29, 2012 · N791UA · Boeing 777222 · APU Bleed Air SystemSDR UALA2012012600545Accelerometer · faultyENG VIB MONITOR R STATUS MSG. RT EVM DEACTIVATED. RPL RT ENG VIB ACCELEROMETER. ENG RUN SYS, OPS CKS GOOD.Jan 25, 2012 · N791UA · Boeing 777222 · Engine Vibration AnalyzerSDR UALA2012010400098Latch · brokenNR 2 ENGINE THRUST REVERSER COWL LATCH HAS A BROKEN RT LOAD SHARE LATCH. REPLACED RT LOAD SHARE LA AT NR 2 ENGINE.Jan 4, 2012 · N791UA · Boeing 777222 · Engine Thrust ReverserSDR UALA2011110305959Latch · brokenOXYGEN BOTTLE STORAGE BIN DREW LATCH BROKEN AND WONT STAY CLOSED. RT SIDE FORWARD OF COAT CLOSETS. EMERGENCY EQUIPMENT IS ALSO DEFFERED. COMPLIED WITH MEL. REPLACED LATCH ASSY AND FACE PLATE ASSY. OP'S CHECK NORMAL.Nov 3, 2011 · N791UA · Boeing 777222 · Portable Oxygen SystemSDR UALA2011110305971Antenna · faultySATCOM HI GAIN STATUS MSG. INSTALLED LEFT & RIGHT HIGH GAIN ANTENNA PCN 583-9203 WITH GEL GASKET 165-0125. NEED TO TORQUE FASTENERS AND SEAL. COMPLETED ITEMS I,J,K AND 2. COMPLETED INSTALLATION PER MM. AFTER REPLACING BOTH SATCOM SIDE MOUNTED HIGH-GAIN ANNov 3, 2011 · N791UA · Boeing 777222 · Communications SystemSDR UALA2011110305952Wire · miswiredCAPT RADIO PUSH-TO-TALK SWITCH ON YOKE INOP. XFER TO MEL. :566-0590 ON AOG H6083. SWITCH PCN 566-0590 PAC ORDERED ON OSTF L6164. 1 EA 566-0590 IN HLD 1. REPLACED SWITCH, NO HELP. TRIED NEW AUDIO CONTROL PANEL AND AUDIO MANAGEMENT UNIT, ALSO NO HELP. NEEDS MOct 31, 2011 · N791UA · Boeing 777222 · Communications System WiringSDR UALA2011091204916Skin · damagedRT FUSELAGE STATIC PORT HAS DENT IN HEATED PORTION. LIGHTNING DAMAGE IN THE EXTRA CRITICAL SKIN AREA AT THE RT STATIC PORT ON THE RT SIDE STA 764. ACCOMPLISHED HFEC INSP OF INSIDE OF DRILLED HOLE AND OF EXT SKIN AROUND HOLE. NO CRACKS FOUND. LIGHTLY BLEND 3ESep 10, 2011 · N791UA · Boeing 777222 · Fuselage Main, Plate/SkinSDR UALA2011072503811Indicator · malfunctionedFIRST OFFICER SIDE STAB TRIM INDICATOR HAS PROBLEM. REPLACED RT STAB POSITION INDICATOR.Jul 25, 2011 · N791UA · Boeing 777222 · Stabilizer Position IndicatingSDR UALA2011071703630Latch · inoperativeCOCKPIT FIRE EXT LATCH WILL NOT LATCH. SECURED FIRE EXT LATCH. SECURE IN BRACKET.Jul 16, 2011 · N791UA · Boeing 777222 · Fire Bottle, PortableSDR UALA2011071103450Controller · faultySTATUS MESSAGE "BLEED PRESS SENSOR L" DISPLAYED. MAINT MESS:36-13001. REPLACED LEFT ASCPC REF AMM. SOFTWARE AND OPS CHECKS OK.Jul 9, 2011 · N791UA · Boeing 777222 · Pneumatic Distribution SystemSDR UALA2011052702583Coupler · damagedHF FAULTS. FOUND 42' OF HF ANTENNA COAX CABLE BAD. COAX CABLE ON OSTF B6425,EST 5-26, 2 CONNECTORS ON OSTFV4295 ETA ON DAYS & OSTF N2455 LC SOURCING.May 25, 2011 · N791UA · Boeing 777222 · Communications System WiringSDR UALA2011050202139Check Valve · malfunctionedFLIGHT CREW REPORTS "APU BLEED AIR" MESSAGE ON APU START UP. CHECK APU CHECK VALVE OPEN & CLOSE FREELY, CLEANED PRESSURE SENSOR. ERASED STATUS MESSAGE & START APU CHECK NO STATUS MESSAGE & MAINT.May 1, 2011 · N791UA · Boeing 777222 · APU Bleed Air SystemSDR UALA2011021800845Fuse · faultySEATS 31 TO 43 LT AND RT AISLES, EMERGENCY LIGHTS ON ARMREST ARE INOPERATIVE. REPLACED FUSE IN POWER SUPPLY. OPS CHECKS GOOD.Feb 18, 2011 · N791UA · Boeing 777222 · Emergency LightingSDR UALA2011013100505Relay · faultyENG FUEL VALVE LT EICAS MESSAGE AND NO LT ENG START. B4 CB IS POPPED. LEFT ENG RELAY UNIT (ERU) IAW MM. RAN ENGINE IAW JRH, ALL PARAMETERS NORMAL. NO FAULTS NOTED & TESTS PASSED.Jan 30, 2011 · N791UA · Boeing 777222 · Fuel Control/Turbine EnginesSDR UALA2011010600085Valve · faultyCSCP-CACP ZONE TEMPERATURE DISPLAY - FAULT MESSAGE SHOWS 111. ZONE A TEMP CONTROL TARGET TEMP SHOWS INVALID DATA MESSAGE -ZONE A TARGET TEMP CONTROL. AHM SHOWS A FAULT OF 21-20 002. FIM HAS INFORMATION REGARDING BLANK TARGET TEMP. MAY REQUIRE VALVE REPLACEMJan 6, 2011 · N791UA · Boeing 777222 · Cabin Temperature Control SystemSDR UALA2011010600084Light · missingSEAT 1E AFT EMERGENCY LIGHT IS MISSING. REPLACED LIGHT ASSY, LIGHT OPS CHECKS GOOD.Jan 6, 2011 · N791UA · Boeing 777222 · Emergency LightingSDR UALA2011010600083Battery Pack · faultyEMERGENCY LIGHTS INOP ROWS 31-42 BOTH AISLES. REPLACED AFT BATTERY PACK AT DOOR 3R. SYSTEM OPERATES NORMALLY AT ROWS 31-42 BOTH SIDES.Jan 6, 2011 · N791UA · Boeing 777222 · Emergency LightingSDR UALA2010121704611Controller · faultyAPU AUTO SHUTDOWN. REPLACED APU VALVE IAW MM AND THE APU CONTROLLER, OPS CKD NORMAL.Dec 17, 2010 · N791UA · Boeing 777222 · APU Bleed Air SystemSDR UALA2010121704610Igniter · failedCREW REPORTED DURING FLIGHT GOT RT ENG IGNITOR 1 (R1) STS MSG. BASED ON AHM BOTH ENG'S HIT AT THE SAME TIME. FOR THE LT ENG: ENG IGNITOR L2 -STATUS- 742 00261, 74-61501, IGNITION SYS NR2 (LT ENG) FAILED TO LIGHT ENG, DUE LONG HISTORY ON THIS SYS DF LT ENG IGNDec 17, 2010 · N791UA · Boeing 777222 · Spark Plug/IgniterSDR UALA2010112304312Blade · crackedENGINE HAS ONE EACH T2 BLADE WITH AXIAL CRACK IN AREA 'B' ON LEADING EDGE. WASHED T2 BLADE AND REINSPECTED AND CONFIRMED CRACK. AXIAL CRACKS AREA 'B' NOT PERMITTED. REMOVED ENGINE.Nov 23, 2010 · N791UA · Boeing 777222 · Turbine SectionSDR UALA2010112204307Fuse · faultyEMERGENCY LIGHTS LOCATED ON SEATS BETWEEN DOORS 3 AND 4 ARE INOP. REPLACED FUSE AT POWER SUPPLY. OPS CHECKS GOOD.Nov 22, 2010 · N791UA · Boeing 777222 · Emergency LightingSDR UALA2010112204305Modulating Valve · faultyHYD PUMP DEM C1 STATUS MSG. MODULATING VALVE FOUND FAULTY. REPLACED MOD VALVE, OP CHECKS OKAY.Nov 22, 2010 · N791UA · Boeing 777222 · Hydraulic Pump (Electric/Engine), MainSDR UALA2010112204303Light · unsecure1F EMERGENCY LIGHT LOOSE. SECURED LIGHT.Nov 22, 2010 · N791UA · Boeing 777222 · Emergency LightingSDR UALA2010111904282Shutoff Valve · faultyRT ENGINE BLEED OFF LIGHT ON AND NO DUCT PRESSURE AVAIL. CYCLED BLEED SWITCH AND ADVANCED THROTTLES TO 60 PERCENT NO HELP. ITEM ROLLED FORWARD. AHM SNAPSHOT SHOWS PRSOV AND HPSOV CLOSED AT IDLE. THE VALVE DEACTIVATED CLOSE POSITION LOCK HPSOV R PER MEL 36Nov 19, 2010 · N791UA · Boeing 777222 · Pneumatic Distribution SystemSDR UALA2010111904283Igniter · faultyLEFT ENGINE IGNITER L2 STATUS MESSAGE. REPLACED IGNITER PLUG AND INSTALL PER MM AND AUDIBLE TEST PASS. REPLACED EXCITER BOX, IGNITION LEAD AND IGNITER PER MM.Nov 18, 2010 · N791UA · Boeing 777222 · Spark Plug/IgniterSDR UALA2010110104039Shutoff Valve · stuckCREW REPORTS RT ENGINE BLEED IS STUCK IN THE CLOSED POSITION & WILL NOT OPEN. DEACTIVATED RT ENG PRSOV IN CLOSED POSITION PER MEL. CHECKED MAT, NO MAINT MESSAGE, NO PREVIOUS HISTORY. INSPECTED PRSOV, CONTROLLER, SENSE LINES, WIRING AND CONNECTORS, NO ABNORMALOct 31, 2010 · N791UA · Boeing 777222 · Engine Bleed Air SystemSDR UALA2010091403415Panel · delaminatedVERTICAL STAB LT SIDE FWD TORQUE BOX SCI N PANEL 322CL (177W3102) HAS DELAMINATION. INSPECTED AREA FOR MOISTURE, COVERED DELAMINATED SKIN WITH DOUBLE LAYER OF SPEED TAPE REF UA-E VA-80083. TO BE REPAIRED 150 FLIGHT HOURS AND TAPE TO BE CHECKED PRIOR TO EACH DSep 11, 2010 · N791UA · Boeing 777222 · Vertical StabilizerSDR UALA2010063002325Light · inoperativeNR 3R DOOR OUTSIDE EMERGENCY LIGHT IS OUT. RELAMPED, OP NORMAL.Jun 29, 2010 · N791UA · Boeing 777222 · Emergency LightingSDR UALA2010061002029Satcom · failedSATCOM SYS FAILS OR NO BUS ACTIVITY. STATUS MSG02- NOT ACTIVE CRUISE INTERMITTENT; SATELLITE DATA UNIT (LT) HAS AN INTERNAL FAULT ON COMMUNICATION CHANNEL 1. REPLACED SDU. OPS GOOD.Jun 9, 2010 · N791UA · Boeing 777222 · Communications SystemSDR UALA2010061002030Line · leakingNR 1 ENG HYD LEAK. NR1 ENG HYD PUMP SUPPLY LINE DAMAGED AND LEAKING AT TOP OF LINE. REPLACED NR1 HYD SUPPLY LINE, LEAK CKD OK. SUSPECT HYD LEAK BEHIND NR 1 ENG SUPPLY HOSE BLANKET. REPLACED NR 1 ENG HYD PRESS HOSE FROM PYLON DISCONNECT TO EDP, LEAK CHECKED OJun 9, 2010 · N791UA · Boeing 777222 · Hydraulic System, MainSDR UALA2010052401764Lamp · inoperativeIN SEAT EMERGENCY EXIT LIGHT AT SEAT 1F IS INOPERATIVE. REPLACED LAMP ASSY, OPS OKMay 24, 2010 · N791UA · Boeing 777222 · Emergency LightingSDR UALA2010050301484Shutoff Valve · faultySTATUS MSG NACELLE VENT VALVE LT. VALVE FOUND DEFECTIVE. REPLACED NACELLE ZONE VENTILATION SHUTOFF VALVE.May 1, 2010 · N791UA · Boeing 777222 · Compressor Bleed ControlSDR UALA2010042601384Modulating Valve · faultyIN CRUISE FL350 AIR SYNOPTIC SHOWS PRESS TO AIR C2 HYD PUMP. DURING TROUBLESHOOTING FOUND DEFECTIVE VALVE. REPLACE MODULATING VALVE, ALL OPS OK.Apr 23, 2010 · N791UA · Boeing 777222 · Hydraulic System, MainSDR UALA2010042101335Pump · faultyFUEL IMBALANCE MSG WAS DISPLAYED ON EICAS. APPX 1 HR AFTER DEPARTURE FUEL IMBALANCE MSG WAS DISPLAYED ON EICAS. READINGS WERE L-64.4 CTR-16.3 R-61.1. APPX 20 MIN LATER READINGS WERE L-64.5 CTR-11.1 R-59.9 TOTALIZER READING TO CALCULATED WITHIN 700 LBS. CREW AApr 20, 2010 · N791UA · Boeing 777222 · Fuel Boost PumpSDR UALA2010031600876Light · inoperativeF-C PAX SEAT 2F AFT EEL ASSY INOPERATIVE. REPLACED PAX SEAT AFT EEL ASSY AND OPS CHECKED ALL GOOD.Mar 15, 2010 · N791UA · Boeing 777222 · Emergency LightingSDR UALA2010030900813Lamp · inoperativeEMERGENCY LIGHT AT SEAT 19C IS INOPERATIVE. RELAMPED, OPS OKAY.Mar 9, 2010 · N791UA · Boeing 777222 · Emergency LightingSDR UALA2010021700604Shutoff Valve · failedTRIM AIR PRSOV RIGHT TRIM AIR PRESSURE RELIEF SHUTOFF VALVE FAILED. RESET OK MSG-2124202 INACTV TA MODE. REPLACED RT TRIM AIR PRESSURE REGULATING AND SHUTOFF VALVE PER MM. TEST PASSED.Feb 17, 2010 · N791UA · Boeing 777222 · Cabin Temperature Control SystemSDR UALA2010021500576Unknown · unknownFUEL IMBALANCE.Feb 15, 2010 · N791UA · Boeing 777222 · Aircraft Fuel SystemSDR UALA2009101503241Light · inoperativeDOOR 4R EXTERIOR MOUNTED EEL INOP. RELAMPED, OP NORMAL.Oct 15, 2009 · N791UA · Boeing 777222 · Emergency LightingSDR UALA2009101503238Charger · inoperativeDOOR 3R EXTERIOR MOUNTED EEL INOPERATIVE. REPLACED CHARGER AT DOOR 3R, TESTS OKAY.Oct 15, 2009 · N791UA · Boeing 777222 · Emergency LightingSDR UALA2009101503237Charger · inoperativeALL SEAT MOUNTED EEL FROM SEAT 31 TO 43 INOP BOTH AISLE. REPLACED CHARGER AT DOOR 3R, TESTS OKAY.Oct 15, 2009 · N791UA · Boeing 777222 · Emergency LightingSDR UALA2009082102586Transmitter · inoperativeFUEL FLOW INDICATION (ENGINE) - BLANK MSG-7360951 ACTIVE DC HARD. ALL FUEL TANK QUANTITY IND SYS OPS NORMAL. MSG 73-60951 FUEL FLOW TX L ENG SIGNAL RANGE HAS OCCURRED ONLY DURING DESCENT ON MOST FLIGHTS. CREW NOTED FUEL FLOW GAUGE WORKED PERFECTLY ENTIRE FLAug 20, 2009 · N791UA · Boeing 777222 · Fuel Flow IndicatingSDR UALA2009081802527Idg · faultyFOUND IDG OIL FILTER SHOWED BLOCKED ON MAINT PAGE DURING ETOPS SVC CHK. FOUND THE DIFFERENTIAL PRESSURE IND (RED BUTTON) OF IDG WAS EXTENDED. DEFERRED PER MEL. DISCONNECTED THE IDG AND SVCD IDG OIL TO FULL. REPLACED NR 1 ENG IDG.Aug 14, 2009 · N791UA · Boeing 777222 · AC Generator-AlternatorSDR UALA2009072002144Idg · faultyL GEN DRIVE DISCONNECTED. REPLACED IDG AND OPS CHECK. OPS CHECK GOOD.Jul 18, 2009 · N791UA · Boeing 777222 · AC Generator-AlternatorSDR UALA2009042801231Bpcu · faultyGALLEY POWER INTERMITTENT. REPLACED BUSS POWER CONTROL UNIT. LOADED NEW SOFTWARE INTO NEW UNIT OPS2402-SUU-BCU-03. TESTED GOOD.Apr 27, 2009 · N791UA · Boeing 777222 · AC Power Distribution SystemSDR UALA2009041001041Module · faultyRIGHT UTILITY BUSS CYCLING ON AND OFF, ALONG WITH FWD & AFT GALLEY POWER. EICAS MSG RECIRC FAN, ALSO DISPLAYED INTERMITTENTLY. KEPT FWD GALLEY PWR SW IN THE OFF POSITION. REPLACED M24405 SIGNAL CONDITIONING CARD PER FIM 24-51 TASK 811, MM 24-09-00, CHECKED Apr 10, 2009 · N791UA · Boeing 777222 · AC Power Distribution SystemSDR UALA2009021300494Wire · shortedFUEL SYNOPTIC PROBLEM. THIS IS NOT A SYNOPTIC PROBLEM. THIS IS A CNTR LT OVERRIDE PUMP PROBLEM. SWAPPING ELMS CARD SOFTWARE. NOW INSTALLED. PUMP STILL RUNS WITH SWITCH OFF. FOUND SHORTED WIRE FROM SW (101TL2834-3) ELCU THAT COMMANDS PUMP. IDENTIFYING WIFeb 12, 2009 · N791UA · Boeing 777222 · Fuel System WiringSDR 2008UALA06052Generator · faultyRIGHT BUG LOW OIL PRESS MSG, LEAKING. FOUND OIL LEAKING FROM DRAIN 3 AT A RUNNING STREAM ON 1ST ENG RUN. STARTED RT ENG A 2NDTIME OIL LEAKING AT 12 DROPS A MINUTE FROM DRAIN 3. REPLACED RT BACKUP GENERATOR. ALL CHECKS NORMAL. Oct 9, 2008 · N791UA · Boeing 777222 · AC Generator-AlternatorSDR 2008UALA05739Connector · disconnectedEMERGENCY LIGHT AT SEAT 2F AFT LIGHT WILL NOT WORK. FOUND UNPLUGGED. RECONNECTED. OP CHECKS OKAY.Sep 15, 2008 · N791UA · Boeing 777222 · Light System WiringSDR 2008UALA05738Light · inoperativeEMERGENCY LIGHT IN AFT GALLEY FLOOR LEVEL LT SIDE WILL NOT WORK. FOUND DEFECTIVE LAMP. REPLACED LAMP. TESTS OKAY.Sep 15, 2008 · N791UA · Boeing 777222 · Emergency Lighting
Back to N791UA