N791UA
Service difficulty reports · 188
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N791UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N791UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 2008UALA05737Light · inoperativeEMERGENCY CEILING LIGHT IN AFT GALLEY WILL NOT WORK. LIGHT FOUND INOP. REPLACED LAMP. TESTS OKAY.SDR 2008UALA05736Cable · disconnectedEMERGENCY LIGHT AT SEAT 38C WILL NOT WORK. FOUND CABLE DISCONNECTED. RE-SECURED CABLE. TESTS OKAY.SDR 2008UALA05735Light · inoperativeEMERGENCY LIGHT AT SEAT 25C WILL NOT WORK. LIGHT FOUND INOP. REPLACED LAMP. OP CHECKS OKAY.SDR 2008UALA05691Generator · faultedLEFT BACK UP GENERATOR BLOCKED FILTER MSG ON SYNOPTIC PAGE. *S/D* FOUND GENERATOR FAULTY. REPLACED NR 1 ENGINE BACK UP GENERATOR. ALL OPS NORMAL.SDR 2008UALA05647Bleed Air Sys · inoperativeAPU BLEED AIR SYSTEM INOP. OIL FOUND IN APU INLET PLENUM ASSY. REPLACED APU ASSY. REPLACED IGV ACTUATOR. OPS NORMAL
SDR 2008UALA05584Controller · malfunctionedSTRONG ODOR IN CABIN. SUSPECT FAULTY CONTROLLER. REPLACED LEFT CABIN TEMPERATURE CONTROLLER. CHECKS OKAY & NO ODOR ON DEPARTURE.SDR UALA2008111304268Control Unit · faultyFLIGHT CONTROL SYSTEM STATUS MESSAGE. REPLACED CENTER ACE AND B27143 COUPLER IN P312-E01 PANEL. FAULT CLEARED.SDR 2008UALA04268Warning Message · illuminatedFLIGHT CONTROL SYSTEM STATUS MESSAGE.SDR 2008UALA03986Fan · faultyEICAS STATUS MESSAGE EQUIP COOLING FAN LT. *S/D* FOUND FAULTY COOLING FAN AND FLOW SENSOR. REPLACED COOLING FAN AND FLOW SENSOR, OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA03598Blade · damagedNR 2 ENGINE FAILED BOROSCOPE INSP 2ND STAGE BLADES HAS 2 EACH BLADES WITH DAMAGE. ENGINE REPLACED. TWO HP TURBINE STAGE-2 BLADES WERE FOUND WITH MISSING PORTIONS OF THE CONCAVE AIRFOIL PLATFORM. THE FAILED BLADES, SERIAL NOS. CKLBHY9532 & CKLBHY7580 HAD IDENSDR 2008UALA02765Sign · looseEMERGENCY EXIT SIGN AT DOOR 4L IS LOOSE. REPLACED LIGHT ASSEMBLY LIGHT. OP CHECKS OKAY.
SDR 2008UALA01157Warning Message · illuminatedHYD PUMP DEMAND RIGHT STATUS MSG.SDR 2008UALA00894Unknown · odorAFTER ENG START CREW REPORTED STRONG OIL ODOR ON FLT DECK. SUSPECT OIL LEAK FROM ENGINE OR APU. CHECKED APU & BOTH ENGINES. NO LEAKS OR OIL CONTAMINATION NOTED. NO ABNORMAL OIL CONSUMPTION NOTED. OK PER FIM 21-00 TASK 808. ACFT OK FOR SERVICE. NO REPEATSDR 2008UALA00773Lamp · inoperativeEEL LIGHTS INOP MID GALLEY RT SIDE. RELAMPED.SDR 2008UALA00706Lamp · inoperativeEEL LIGHTS INOPERATIVE MID GALLEY RT SIDE. RELAMPED.SDR 2008UALA00705Lamp · inoperative3L EXTERIOR MED EMERGENCY LIGHT INOP. SUSPECT FAULTY BULB. RELAMPED. OPS CHECKED OK. ACFT OK FOR SERVICE.SDR 2008UALA00387Battery · dischargedA/C LOST POWER AT GATE PRIOR TO DEPARTURE. ACFT WILL NOT POWER UP. SUSPECT BATTERY VOLTAGE LOW. REPLACE MAIN AND APU BATTERYS. REPLACED APU BATTERY CHARGER. OPERATION NORMAL. REPLACED MAIN BATTERY CHARGER. GRD CHECKED NORMAL. ACFT OK FOR SERVICE.
SDR 2008UALA00343Light · inoperativeEMERGENCY EXIT LIGHT OUTSIDE DOOR 3L INOPERATIVE. RELAMPED EMERGENCY LIGHT.SDR 2007UALA05005Skin · delaminatedRIGHT SIDE OF THE VERTICAL STABILIZER IS DELAMINATED. BLISTER ON VERTICAL FIN BETWEEN STATIC PORTS RT PANEL REMOVED FOR REPAIR. SENT TO SHOP 273. R&R R30639. REINSTALLED PANEL. AC OK FOR SERVICE.SDR 2007UALA02965Circuit Board · faultedDET ZONE 1 CARGO AFT MESSAGE. REPLACED CARGO SMOKE DETECTOR. TESTED THRU THE MAINTENANCE ACCESS TERMINAL. NO MESSEGE FOUND GROUND TESTED NORMAL. SUSPECT ELECTRONIC CIRCUIT FAULT.SDR 2007UALA01645Switch · faultyCABIN MED 3RT FAILED EPAS BATTERY OPERATIONAL TEST. [06-20-07] REPLACED MODE SELECTOR SWITCH AND OPS CHECK PER MM 52-11-28, AND COA208701. TEST OK. A/C OK FOR SERVICE.SDR 2006UALA01702Coffeemaker · smokeSMOKE IN AFT GALLEY. AFT GALLEY HAD HEAVY SMOKE UNTIL GALLEY POWER TURNED OFF. CREW OBSERVED THAT SMOKE CAME FROM RIGHT SIDE WALL ABOVE COFFEEMAKER M41 AND M42. ONCE ON GROUND, AND ALL GALLEY EQUIPMENT POWER SWITCHED ON, NO SMOKE FROM THIS AREA. HOWEVER, HSDR 2006UALA01509Skin · damagedSKIN FWD OF NR 2L DOOR STA 670 BETWEEN STR 26L- 27L SMALL DENT WITH A GOUGE IN THE CENTER APPROX 2.0 INCH IN DIA AND .050 INCH DEEP. BLENDING FOR CLEANUP REMOVED 17 PERCENT OF THE ORIGINAL .070 SKIN THICKNESS. ANOTHER DENT EXISTS APPROX 6 INCHES FROM REWORKESDR 2006UALA00631Starter · malfunctionedLEFT IDG FAILED EN ROUTE, APU NO START. APU ELECT STARTER FAILS CHRONIC APU ELECTRIC STARTER PROBLEMS - 7 STARTERS SINCE APU INSTALLATION JAN 05, + 3 START CONTACTORS 2 APU BATTS, 2 CHARGERS SEVERAL APUC'S, AUTO START CONT RELAYS AND VARIOUS OTHER APU COMPONESDR 2006UALA00580Wedge · delaminatedTHE NR 2, 3 AND 13 LEADING EDGE SLATS HAVE LOCALIZED DELAMINATION ON THE LOWER SKIN OF THE TRAILING EDGE WEDGE. DELAMINATION REPAIRED TEMPORARILY WITH STRUCTURAL ADHESIVE INJECTION UNTIL PERMANENT REPAIR CAN BE ACCOMPLISHED AT THE NEXT HMV. AN NDT INSPECTIONSDR 2006UALA00225Wire Harness · damagedBOTH EEL LIGHTS INOP AT 3E.SDR 2006UALA00224Lamp · burned outAFT EEL LIGHT INOP AT 1E.SDR 2004UALA00846Housing · leakingNR 2 ENGINE LOSS OF OIL PRESS/QUANTITY, TEMP INCRG/PRESS DCRSG. AMBER ALERT DECLARED FOR EMERGENCY EQUIPMENT, AFCT LANDED NORMALLY. FOUND MEATL ON THE MAIN & ANGLE GEARBOX (AGB) CHIP DETECTOR. THE ENGINE WAS REPLACED IN SEA. (NOTE: THE MASTER MCD HAD CHECKSDR 2004UALA00601Engine · leakingNR 1 ENGINE SHUT DOWN DUE TO LOSS OF OIL QUANTITY/PRESSURE. NR 2 BEARING FAILED. THIS IS THE MAIN THRUST BEARING SUPPORTING THE N2 ROTOR. BEARING CAGE IS FRACTURED. ALL BALLS ARE HEAVILY SPALLED AND "SQUARED OFF". OUTER RACE RIVET PIN STILL INSTALLED. OUTER SDR 2004UALA00502Wire Harness · shortedFOUND WIRE BUNDLE IN PIT BURNED. ALL CB'S IN PIT POPPED. CAUSE IS UNDERSTOOD AT THIS TIME TO BE A PRODUCTION SPLICE FOR A PDU SHORTED FROM MOISTURE, RESULTING FROM DIRECT CONTACT WITH THE BILGE INSULATION. REMOVED WIRES ARE BEING ANALYZED. REPLACED THE DAMSDR 2004UALA00151Indicator · brokenEXIT PATH LIGHTING INDICATOR LOOSE-BROKEN 11F. REPLACED AND TESTED LIGHT ASSY.SDR 2003UALA00744Light · damagedEMERGENCY LIGHT ON MOVABLE ARMREST OF SEAT 3E DAMAGED. REPLACED LIGHT ASSY.SDR 2003UALA00091Frame · crackedNR 2 PYLON SAILTAIL FRAME WAS CRACKED AT C-CHECK. MAJOR REPAIR ACCOMPLISHED. FRAME REPLACED.SDR 2002UALA01498Bearing · failedLEFT ENGINE OIL FILTER DIFFERENTIAL WARNING EICAS ILLUMINATED. REPLACED ENGINE. SUBSEQUENT SHOP TEARDOWN REVEALED FAILURE OF THE NR 1 BEARING. BOTH OF THE BEARING'S INNER RACEWAY HALVES HAD MACHINED THE CAGE INNER DIAMETER 360 DEGREES.SDR 2001UALA00651Sense Line · fracturedRIGHT ENGINE DID NOT SPOOL UP TO FULL TAKEOFF POWER, LAG 1.5 KNOTS BEHIND LEFT THROTTLE. ABORTED TAKEOFF AT LOW SPEEDS. *S/D* FOUND PROBLEM WITH LEFT ENGINE PT 4.95 LINE RIGHT ENGINE OPS NORMAL. FOUND LINE BROKEN ON LEFT ENGINE. PER 1-0-13-3 INTRIM REPAIRSDR 2001UALA00447Stiffener · crackedSTA. 246 BUCKLED FWD STIFFENER AT:LBL - 7.88 RBL - 7.88 STA. 246 CRACKED FWD STIFFENER AT: RBL 26.06 SUPPLEMENTAL DATA UPDATE REPLACED STIFFENERS PER SRM 53-10-51, REPAIR 3.SDR 99UAL900345Oven · dirtyBURNT PLASTIC SMELL IN MID GALLEY. FOUND AND REMOVED MELTED PLASTIC FROM WARMING OVEN AT POSITION W31. SEA CLEANED INSIDE OF WARMING OVEN.SDR 97UAL900775Engine · failedLOUD BANG AT V1 FROM RIGHT ENGINE. LOSS OF OIL PRESSURE AND QUANTITY. ENGINE SHUT DOWN AT 6000 FT. AIRCRAFT RETURNED TO LHR.
Back to N791UA