N795UA
Service difficulty reports · 206
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N795UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N795UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2026051416225Unknown · odorF/A S REPORT A BURNING PLASTIC ODOR NEAR 3L/3R ON DESCENT BELOW 10000. DEBRIEFED CREW, ODOR WAS PRESENT MOMENTARILY AT DOORS 3L & 3R. NO ODOR WAS PRESENT IN CREW REST OR LAVS. ACCOMPLISHED CONDITIONAL INSPECTION FOR SMOKE ODOR IN THE CABIN REF AMM 05-51-58-80SDR CALA2025102010271Oven · smokeOVEN SMOKING, NEEDS CLEANING COACH CLASS CABIN WHITE SMOKE BRIEFLY SMELLED LIKE FOOD. FAN BLACK.ENDED W OVEN OF F OVEN WITH INTENSIVE SMOKE WHEN OPERATES, TX AS PER NEF2520AV. C/B COLLAR APPLIED. REF NEF 2520AV OVEN WITH INTENSIVE SMOKE WHEN OPERATES, TX AS PESDR CALA2025060305220Thermocouple · faultyEGT EXCEEDENCE ENG R DURING INITIAL CLIMB. RE DUCED THRUST EGT N ORML FAULT MESSAGE 75-50802 WAS SHOWN ON MAT. TCA THERMOCOUPLE PROBE TEMPERATURE RANGE CH B HAS BEEN REMOVED AND REPLACED. MESSAGE IS NO LONGER ACTIVE. POWERPLANT TEST PASSED. REF AMM 75-25-07 SDR CALA2025052104889Battery Pack · dischargedR1 DOOR EMERGENCY LIGHT POWER SUPPLY BATTERY PACK LOW CAPACITY - ORIGINATED BY EMP V903218 ON HAECO NR 9465706, RAISED FROM WORK CARD 86-3350-1-0002. SDR REPORTABLE ENTERED. PERFORMED BY EMP V903218, IDT BY TA317. REPLACED R1 DOOR EMERGEN CY LIGHT POWER SUPPLYSDR CALA2025051904776Battery · dischargedM/D R4 DOOR AFT EMERGENCY POWER SUPPLY M33409 BATTERY PACK FOUND LOW CAPACITY. REPLACED THE M/D R4 DOOR AFT EMERGENCY POWER SUPPLY M33409 BATTERY PACK AS PER AMM 33-51-06-960-802 REV 103, PERFORMED THE NEW BATTERY PACK INSTALLATION TEST AS PER AMM 33-51-06-SDR CALA2025051604735Battery Pack · dischargedM/D R3 DOOR AFT EMERGENCY POWER SUPPLY M33401 BATTERY PACK FOUND LOW CAPACITY.SDR CALA2025051604734Battery Pack · dischargedM/D L1 DOOR AFT EMERGENCY POWER SUPPLY M33424 BATTERY PACK FOUND LOW CAPACITY - ORIGINATED BY EMP V903218 ON HAECO NR 9464018, RAISED FROM WORK CARD 86-3350-1-0002. REFERENCE LOG PAGE 4840315 FOR SDR REPORTING. FOR SDR REPORTING REFERENCE LOG PAGE 4840315 FOR SDR CALA2025051604733Battery Pack · dischargedM/D R3 DOOR FWD EMERGENCY POWER SUPPLY M33404 BATTERY PACK FOUND LOW CAPACITY.SDR CALA2025051504699Battery Pack · dischargedM/D L2 DOOR AFT EMERGENCY POWER SUPPLY M33099 BATTERY PACK FOUND LOW CAPACITY - ORIGINATED BY EMP V903218 ON HAECO NR 9464034, R AISED FROM WORK CARD 86-3350-1-0002. REPLACED THE M/D L2 DR AF T EMERGENCY POWER SUPPLY M33099 BATTERY PACK AS PER AMM 33-51-06 -96SDR CALA2025051504698Battery Pack · dischargedM/D L3 DOOR FWD EMERGENCY POWER SUPPLY M33400 BATTERY PACK FOUND LOW CAPACITY - RAISED FROM WORK CARD 86-3350-1-0002. REPLACED M/D L3 DR FWD EM ERGENCY POWER SUPPLY M33400 BATTERY PACK AS PER AMM 33-51-06-960 -802 REV 103. PERFORMED THE NEW BATTERY PACK INSSDR CALA2025022102408Battery · no testDURING EMERGENCY LIGHT TEST IT WAS FOUND EMERGENCY EXIT SIGN DOES NOT COME ON DOOR 3 LEFT PERFORMED FIM TASK 33-51 TASK 803, REPLACED POWER SUPPLY AS REF TASK 33-51-06-960-803 AND BATTERY PACK AS REF TASK 33-51-06-960-802. AFTER EMERGENCY LIGHTS OPERATIONAL TESDR CALA2024112001208Signal Cond Unit · faultedAFTER T/O EICAS MSG OXYGEN PAX ON DISPLAYED DOOR 1L 2L DECMP ALE RT REF MM 21-31-00-700-806-001, ACP MAT TEST ON LEFT AND RIGHT CABIN PRESSURE CONTROLLER SYSTEMS. BOTH PASS MTC MSG 35-13012 TECH SUPPORT UPDATE: INFO ONLY, PER AHM MESSAGE 35-13012 WAS GENERATEDSDR CALA2024100700756Egt Indication · illuminatedENG2 SN. 222173 (TSI 7963) CREW REPORTED THAT #2 EGT EXCEEDED ON T-OFF. AHM SHOW ENG R EGT RED, MM MSG 77-62122, EXCEEDANCE REPO RT SHOW PEAK 680.5 (TOL=TIME OVER LIMIT 5.SEC). REF FIM 71-05 TA SK 833. RETRIEVE EGT PEAK & DURATION FROM R ENG EXCD. MAINT PG. ATSDR CALA2024022700563Actuator · inoperativeCONFIGURATION GEAR LOW SPEED ABORT MAIN GEAR STEERING ST REQUIRE MEL FOR THE MAIN GEARS STEERING PULLED C/B ON PANEL P110 N27 FOR THE MEL SPEED WAS NORMAL. COMPLIED WITH MEL SPEED BELOW 40KNOTS AND BRAKE IS READING ZERO AND COLD. APPROVED FOR MEL 3253A MMSG 32SDR CALA2024010400032Battery · inoperativeCABIN GALLEY 2 AND GALLEY 3 MOUNTED EMERGENCY LIGHTS FAILED TO OPERATION REF HAECO NR NO.9474380. CABIN L2 DOOR HEADER EMERGENCY LIGHT BATTERY M33096 REPLACED AND INSTALLATION TEST CARRIED OUT,RESULT NORMAL REF TO AMM 33-51-06-960-802 REV.99.SDR CALA2024010400031Battery · inoperativeCABIN R4 DOOR EXIT SIGN AND AISLE EXIT SIGN EMERGENCY LIGHTS FAILED TO OPERATE. CABIN R4 DOOR HEAD ER EMERGENCY LIGHT BATTERY M33408 REPLACED AND INSTALLATION TEST CARRIED OUT REUSLT NORMAL REF TO AMM 33-51-06-960-802 REV.99.SDR CALA2024010400030Battery · inoperativeCABIN L4 DOOR EXIT SIGN AND GALLEY 9 MOUNTED EMERGENCY LIGHTS FA ILEDTO OPERATION REF HAECO NR NO.9474382. L4 DOOR HEADER EMERGENCY LIGHT BATTERY M33407 REPLACED AND INSTALLATION TEST CARRIED OUT,RESULT NORMAL REF TO AMM 33-51-06-960-802 REV.99.SDR CALA2024010400029Battery · inoperativeCABIN L2 DOOR EXIT SIGN AND AISLE EXIT SIGN BATTERY CAPACITY CHK FAILED REF HAECO NR NO.9474383 - ORIGINATED BY EMP V905376, SPEC NO.B777-33-3-7019, CAB L2 DOOR HEADER EMERGENCY LIGHT BATTERY M33099 REPLACED AND INSTALLATION TEST CARRIED OUT, RESULT NORMAL REFSDR CALA2023092002832Starter · intermittentFIRE ENG R IN FLT INTERMITTENTLY CONTACT TOMC FOR FURTHER DETAILS. ASSY REPLACED REF AMM 26-11-01-401. FIRE TEST PASSED AND STS MESSAGE CLEARED.SDR CALA2023011800151Control Unit · arcedFUEL JETT PUMP L EICAS STATUS LEFT JETTISON PUMP COMMANDED ON AND LOW PRESSURE. NOTICED IN CRUISE FLT HAS HISTORY. FOUND LEFT FUEL JETTISON PUMP M28104 SHOULD SHOW ON & PRESSURE. INSTEAD IT IS SHOWING ON AND NO PRESSURE. R&R LT JETT PUMP. COMPLETED INSTALLATISDR CALA2022101802838Charger · failedB777-33-3-7019 DR R2 EMER LT BATTERY CHARGER M33097 TEST FAIL. TRANSFER REF NON - ROUTINE WO.1139465 AND ORIG BY V898181SDR CALA2022101802837Charger · failedB777-33-3-7019 DR L4 EMER LT BATTERY CHARGER M33407 TEST FAIL. TRANSFER REF NON - ROUTINE WO.1139480 AND ORIG BY V898181SDR CALA2022101802836Charger · failedB777-33-3-7019 DR R2 EMER LT BATTERY CHARGER M33098 TEST FAIL. TRANSFER REF NON - ROUTINE WO.1139470 AND ORIG BY V898181SDR CALA2022101802835Charger · failedB777-33-3-7019 DR R3 EMER LT BATTERY CHARGER M33404 TEST FAIL. TRANSFER REF NON - ROUTINE WO.1139449 AND ORIG BY V898181SDR CALA2022101802834Charger · inoperativeB777-33-3-7019 DR R3 EMER LT BATTERY CHARGER M33401 TEST FAIL. TRANSFER REF NON - ROUTINE WO.1139495 AND ORIG BY V898181SDR CALA2021101801900Battery Pack · noneDURING DEEP-CYCLE,FOUND L4 DOOR(DM33407) EMERGENCY LT BATTERY PA CK CAN NOT OPERATE FOR A MINIMUM OF 15 MINUTES REFER HAECO NON-R OUTINE NO.9461209,ORIGINATED BY EMP:V903686,SPEC NO.B777-33-3-70 19. PERFORMED BY EMP:V903686,REPLACED L4 DOOR (DM33407)EMERGENCY SDR CALA2021101401876None · noneDURING DEEP CYCLE, FOUND L1 DOOR AFT (DM33424) AND L4 DOOR (DM33 407) EMERGENCY LT BATTERY PACK CAN NOT OPERATE FOR A MINIMUM OF 15 MINUTES REF TO HAECO NON-ROUTINE NO. 9457768, SPEC NO. B777-3 3-3-7019. PERFORMED BY EMP V903686, REPLACED L1 DOOR AFT DM33424 ASDR CALA2021101401861Battery Pack · noneDURING DEEP-CYCLE, FOUND R2 DOOR FWD EMERGENCY LT BATTERY PACK M33097 CAN NOT OPERATE FOR A MINIMUM OF 15 MINUTES REF TO HAECO NON-ROUTINE NO. 9459827, SPEC NO. B777-33-3-7019. PERFORMED BY EMP V903686, REPLACED R2 DOOR FWD EMERGENCY LT BATT ERY PACK M33097, PSDR CALA2021101401860Battery Pack · noneDURING DEEP-CYCLE, FOUND R3 DOOR FWD EMERGENCY LT BATTERY PACK M33401 CAN NOT OPERATE FOR A MINIMUM OF 15 MINUTES REF TO HAECO NON-ROUTINE NO. 9459828, SPEC NO. B777-33-3-7019. PERFORMED BY EMP V903686, REPLACED R3 DOOR FWD EMERGENCY LT BATT ERY PACK M33401, PSDR CALA2019112702093Charger · inoperativeTEST FOUND LH DR NO.3 EMER LIGHT POWER SUPPLY M33405 INOP.SDR CALA2019112702089Skin · chafedV/STAB R/H ROOT PNL 321AR 322AR TO FUSELAGE INTERFACE CROWN SKIN FOUND CHAFING FROM BSTA 2129 TO BSTA 2150 REF NON-ROUTINE NO. 9 488996 - ORIGINATED BY EMP V916782 SPEC NO. B777-55-3-7032. PERFORMED BY EMP V916782, V/STAB R/H ROOT PNL 321AR 322AR TO FUS ELAGE SDR CALA2019112542045Lamp · burned outL/H DOOR 4 SLIDE LIGHT FOUND INOP. REF NON-ROUTINE NO.9489692 - ORIGINATED BY EMP V905511 SPEC NO. B777-33-7015.SDR CALA2019112542044Battery Pack · dischargedFOUND M33094 EMER POWER BATTERY LOW CAPACITY (P/N: ADD717-01-10 0). REF NON-ROUTINE NO. 948964.SDR CALA2019112542043Battery Pack · dischargedTEST FOUND LH DR NO.2 EMER LT BATTERY PACK M33099 INOP. REF NON- ROUTINE NO. 9493498SDR CALA2019112542042Battery Pack · dischargedFOUND M33406 EMER POWER BATTERY FOUND LOW CAPACITY (P/N: ADD717 01-100). REF NON-ROUTINE NO. 9489694SDR CALA2019112542040Battery Pack · dischargedM33098 EMER POWER BATTERY FOUND LOW CAPACITY (P/N: ADD717-01-100 ). REF NON-ROUTINE NO. 9489647 -SDR CALA2019112542039Battery Pack · dischargedFOUND M33093 EMER POWER BATTERY LOW CAPACITY (P/N: ADD 717-01-10 0) REF NON-ROUTINE NO. 9489649 - SPEC NO. B777-33-6-7015.SDR CALA2019112542038Frame · crackedPERFORM OPEN HOLE INSP FOUND CRACK AT LH FRONT SPAR LOWER CHORD. REF NON-ROUTINE NO.9489080 - EA 5300-0 6900B OP13 STEP 8.8. WING CENTER SECTION FRONT SPAR LOWER C HORD STA 1035 LBL81.30 CRACK AREA REPAIRED AS PER SRM 57-10-10 R EPAIR 1 FIG202 REV 81.SDR CALA2019090901514Panel · missingLT WING UPPER BODY TO WING FAIRING HALF WAY BETWEEN THE FORWARD AND AFT EDGE DAMAGED/MISSING. ITEM UPDATED TO IDENTIFY AS A SDR ITEM REMOVED LT OVERWING PANEL 193DL P/N 149W4210-1. M&E 25-5390-3-0003 DISREGUARD M&E NUMBER. USE 149W4210-1 COMPLIED WITH TASK 05-SDR CALA2018082701857Light · brokenLWR EMERGENCY LIGHTS, FOUND BROKEN. REPLACED THE MAIN DECK PARTITION LOWER EMERGENCY LIGHTS, OPS TESTED NORMAL IAW AMM 33-51-05-960-802, REV 83.SDR CALA2018082701854Battery · dischargedFOUND THE CABIN A4 GALLEY AREA, ALL EMERGENCY LIGHT INOPERATIVE. REPLACED THE BATTERY M33409 AND OP TESTS CARRIED OUT, FOUND NORMAL IAW AMM 33-51-06-960-8, 03, REV 83.SDR CALA2018082701845Battery · dischargedFOUND THE L3 DOOR AREA EMERGENCY LIGHT POWER SUPPLY BATTERY M33400 HAD LOW CAPACITY. REPLACED THE BATTERY, OPS TESTED NORMAL IAW AMM 33-51-06-960-802, REV 83.SDR CALA2018012600323Slide · unlatchedL1 DOOR SLIDE PACK UNLOCKED. RELATCHED THE NR 1 SLIDE BUSTLE IAW AMM 25-66-06.SDR CALA2017111003991Lens · damagedEXIT LIGHT LENS AT THE L2 DOOR DAMAGED. REPLACED THE LENS.SDR CALA2017100203370Lamp · inoperativeL3 DOOR EXTERIOR EMERGENGY LIGHT INOPERATIVE. REPLACED THE LAMPS. OPS CHECKED OK.SDR CALA2017071702256Pump · faultyLEFT ENGINE FAILED TO ACCELERATE DURING TAKE OFF. AUTOTHROTTLES WERE ENGAGED. REMOVED AND REPLACED THE FUEL PUMP IAW MM 73-11-01, REMOVED AND REPLACED THE FUEL METERING UNIT IAW MM 73-21-01. PERFORMED TEST 2A LEAK TEST, WET MOTOR TEST, TEST 3 IDLE POWER, TESDR CALA2017071402228Lens · missingLENS MISSING ON EMERGENCY LIGHT AT ROW 7HG. SECURED THE LENS.SDR CALA2017032700746Compressor · faultyELECTRICAL BURNING SMELL IN AFT CABIN AREA. TURNED OFF ALL CABIN LIGHTS AND SMELL DID NOT GO AWAY. CHECKED L FOUND SMELL STRONGEST AT ZONE E RIGHT SIDE ROWS 40-45, FOUND ALL WHILE PERFORMING INSPECTIONS PER AMM 05-51-58 FOUND ELECTRIC LAVATORY AND GALLEY LIGHTSDR CALA2017011600109Fuse · blownEMER LIGHTS AT G-2 & G-3 GALLEYS INOP. REPLACED EMER LT POWER SUPPLY FUSES AND C/O OPERATION TEST FOUND NORMAL AS PER AMM 33-51-06-960-801 REV78.SDR CALA2017011600112Panel · defectiveCOCKPIT EVACUATION PANEL FOUND POOR CONDITION. REPLACED COCKPIT EVACUATION PANEL AND CARRIED OUT OP TEST OF EVAC SYS FOUND "NORM" REF AMM 25-63-02-700-801 REV 78.
Back to N795UA