N805SY
Service difficulty reports · 190
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N805SY' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N805SY' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SCNA20260911389Lamp · inoperativeEMERGENCY AREA LIGHT AT 12DEF INOPERATIVE. REPLACED THE LAMPS EMERGENCY AREA LIGHT AT 12DEF IAW AMM 33-51-03-960-801. OPS CHECK GOOD.SDR SCNA20260908385Light · inoperativeAFT GALLEY LIGHT SECTION OF EMERGENCY LIGHTS INOPERATIVE. R & R CHARGER ASSY AFT LEFT IAW AMM 33-51-06-960-806. R & R AFT LEFT BATTERY PACK IAW AMM 33-51-06-960-805. OPS CHKD GOOD.SDR SCNA20260713293Hinge · deformedEVERY 7 DAYS CHECK LAVATORY "D" DOOR FOR DIFFCULT OPERATION, SHARP EDGES AROUND LOWER MODIFIED HINGE, HINGE CENTER HAS DEFORMED AND BENT AWAY FROM LAVATORY DOOR. CONTACT INTERIORS ENGINEERIF ANY OF THE ABOVE OCCUR. ( LIFE LIMITED REPAIR PER AMM/ENG ) PERFORMESDR SCNA20250629266Cover · loose15A PLASTIC COVER OVER EMERGENCY EXIT LOOSE. RESECURED 15A PLASTIC COVER WITH STUDS REF AMM 52-22-51. OK FOR SERVICE.SDR SCNA20260629267Light · unsecureROW 15D EMERGENCY LIGHT STRIP IS TOR AND ON FLOOR. RESECURED LIGHTSTRIP AT 15D REF AMM 33-50-07 OKAY FOR SERVICESDR SCNA20260629264Oven · odorCHEMICAL, ELECTRICAL ODOR AFTER USE OF AFT GALLEY OVEN NR 3.SDR SCNA20260528217Girt Bar · unpackedAFT SERVICE DOOR ESCAPE SLIDE LOWER FLAP FOR GIRT BAR NEED TO BE REPACKED, HANGS OUT TO FAR AND CATCHES ON DOOR THRESHOLD. REPACKED GIRT BAR FLAP ON AFT SERVICE DOOR REF AMM 25-66-01. DID NOT REMOVE SLIDE ASSY FROM DOOR.SDR SCNA20260528216Slide · unpackedAFT ENTRY DOOR ESCAPE SLIDE NEEDS LOWER FLAP FOR GIRT REPACKED,HANGS OUT TO FAR AND CATCHES ON DOOR THRESHOLD REPACKED GIRT BAR FLAP ON AFT ENTRY DOOR REF AMM 25-66-01.. DID NOT REMOVE SLIDE FROM DOORSDR SCNA20260528215Girt Bar · unpackedFWD ENTRY DOOR ESCAPE SLIDE NEEDS LOWER FLAP FOR GIRT BAR REPACKED , HANGS OUT OUT TO FAR AND CATCHES ON DOOR THRESHOLD. REPACKED GIRT BAR FLAP ON AFT SERVICE DOOR REFF AMM 25-66-01.SDR SCNA20260325143Light · inoperativeRIGHT OVERWING EMERGENCY LIGHT AFT IS INOPERATIVE. R & R RT AFT OVERWING EMERGENCY LIGHT IAW AMM 33-51-04 OPS CHECK GOOD AT THIS MOMENT,SDR SCNA20260310112Window · detachedSLIDE WINDOW COVER ON DOOR 2L UNATTACHED. SECURED L2 DOOR SLIDE PACK COVER WINDOW AS REQUIRED. PRESSURE GAGE CHECKS NORMAL & OK FOR SERVICE REF AMM 25-66-01. SLIDE PACK & COVER WAS NOT REMOVED FOR WORK PERFORMED.SDR SCNA20260216085Light · detachedAFT RIGHT LAV (2R) EMERGENCY CALL LIGHT PANEL FELL OFF. INSTALLED EMERGENCY CALL LIGHT PANEL AT LAV AFT RIGHT (2R) IAW AMM 33-27-00, OPS CK GOOD, A/C OK FOR SERVICE.SDR SCNA20260202053Light · detachedROW 19 DEF EMERGENCY PATH LIGHTS / STRIPS NOT IN PLACE. RESECURED FLOOR TRACK LIGHTING REF 33-51-16SDR SCNA20260202050Glowstrip · detachedEMERGENCY GLOW LIGHT STRIP IN ISLE AT 12 DEF LOOSE ON FLOOR. REATTACHED FLOOR GLOW STRIPPING AT ROW 12 DEF IAW AMM 25-27-00SDR SCNA20251208464Lamp · inoperative14DEF NO SMOKING LIGHT INOPERATIVE. REMOVED AND REPLACED 14DEF NO SMOKING LAMPS IAW 33-25-00, OPS CHECKED GOOD.SDR SCNA20250904356Light · inoperativeEMERGENCY LIGHTS AT OVERHEAD BINS 15 AND 20 RH, LAV D, GALLEY 4 AND (3 EAS) INTERNAL AT EXIT OVERWINGS DON'T TURN ONSDR SCNA20250905363Floor Support · damagedAFTER REMOVAL DAMAGE IN REFERENCE NRC 285 ELONGATED HOLES WERE FOUND IN FOLLOWING COMPONENTS • FLOOR SUPPORT AT STA 993, LBL 32 TO 44 • FLOOR SUPPORT AT STA 993, RBL 32 TO 44 • ANGLE FLOOR SUPPORT AT LBL 46, STA 966-986 • FLOOR SUPPORT AT LBL 16, STA 967-986SDR SCNA20250903350Floor Support · crackedAFTER REMOVAL INTERCOSTAL BTW STA 294/ STA 312 & RBL-31 ON FLOOR STRUCTURE OF W1 WAS FOUND CRACK ON INTERCOSTAL. INTERCOSTAL BTW STA 294/STA 312 & RBL-31 ON FLOOR STRUCTURE OF W1 WAS REPAIRED PER B737-800 SRM 53-10-51-2R-6 REPAIR 6SDR SCNA20250903354Frame · crackedCRACK ON FRAME STA 312 & S-6L AT PASSENGER CABIN. FRAME STA 312 & S-6L AT PASSENGER CABIN WAS REPAIRED PER SRM 53-10-07-2R-1 REPAIR 1SDR SCNA20250903353Crossbeam · crackedCRACK IN FLOOR TRANSVERSAL BEAM AT STA 294 & RBL 56, W1. FLOOR TRANSVERSAL BEAM AT STA 294 BTW RBL 25 & RBL 56, W1 WAS REPAIRED PER SRM 53-10-51-2R-16 REPAIR 16SDR SCNA20250812316Fitting · corrodedCORROSION IN FLOOR FITTINGS ESCAPE SLIDE (2 EAS), DOOR L1. FLOOR FITTINGS ESCAPE SLIDE (2 EAS), DOOR L1 WERE REPLACED PER B737-800 SRM 51-40-02-0G-0SDR SCNA20251009398Intercostal · crackedCRACK ON INTERCOSTALS (3EAS) AT LBL 45 BTW STA 312 & STA 328; AT BL 0, BTW STA 277 & STA 294; AT RBL 35 BTW STA 312 & STA 328, W1. INTERCOSTALS (3EAS) AT LBL 45 BTW STA 312 & STA 328 (P/N 141A5410-12), AT BL 0 BTW STA 277 & STA 294, AT RBL 35 BTW STA 312 & STSDR SCNA20250903351Frame · cracked87619 NR133: INITIAL INSPECTION: CRACK ON FRAME STA 312 & S-6L AT PASSENGER CABIN EMP 10001944 - SUMMARY: FRAME STA 312 & S-6L AT PASSENGER CABIN WAS REPAIRED PER B737-800 SRM 53-10-07-2R-1 REPAIR 1SDR SCNA20250808309Lamp · inoperativeLEFT AFT EXTERIOR EMERGENCY LIGHT INOPERATIVE. LAMP AT LEFT AFT EXTERIOR EMERGENCY LIGHT WAS REPLACED PER B737-800 AMM 33-51-04 SATISFACTORY TEST.SDR SCNA20250808307Power Supply · no testDURING OPERATIONAL CHECK OF THE EMERGENCY LIGHTS, AISLE EMERGENCY LIGHTS 16RT-25RT AND 18LT-21LT-24LT-26LT DON'T TURN ON. POWER SUPPLY - BATTERY PACK M1670 WAS REPLACED PER B737-800 AMM 33-51-06 SATISFACTORY TESTSDR SCNA20250808306Nonskid · degradedDEGRADED NON-SKID COATING FOR THE EMERGENCY ESCAPE PATH ON RT & LT OVERWING WALKWAY. PAINT WAS RESTORED ON THE EMERGENCY ESCAPE PATH ON RH/LH OVERWING WALKWAY PER B737-800 AMM 51-21-97-370-802 AND AMM 51-21-99-300-801.SDR SCNA20250903352Doubler · crackedCRACK ON INNER SURROUND DOUBLER OF AFT CUTOUT AT EXTERNAL POWER RECEPTACLE DOOR EMP 317018 - INNER SURROUND DOUBLER OF AFT CUTOUT AT EXTERNAL POWER RECEPTACLE DOOR WAS REPAIRED PER B737-800 SRM 53-10-15-2R-4 REPAIR 4.SDR SCNA20250731291Carpet · unsecureWEATHER STRIP IN AFT GALLEY IN FRONT OF THE LAV IS LIFTING AND BECOMING A TRIPPING HAZARDTAPED DOWN CARPET TRANSITION REF AMM 25-27-15. A/C OK FOR SVCSDR SCNA20250623225Oil System · leakingNR 1 ENGINE OIL QTY DECREASED TO 2 QUART INFLIGHT. STARTED AT 18 QUARTS. LEVEL DID NOT RECOVER TO NORMAL. 6 QUART DROP/ 1 HOUR. PERFORMED ENG VENTS AND DRAINS INSP. IAW AMM 71-71-00, FOUND FUEL/ OIL HEAT EXCHANGER LEAKING FROM DRAIN OUT OF SERVICABLE LIMITS. SDR SCNA20250603189Oven · dirtyAFT OVEN A/C LEFT SMOKES, NEEDS TO BE CLEANED ( NON-ESSENTIAL EQUIPMENT AND FURNISHING. CLEANED AFT GALLEY OVEN #3 OPS CHECK GOOD REF AMM 25-31-01. THIS CLEARS MEL 25-10 MDDR# 131761SDR SCNA20250502153Oven · dirtyAFT GALLEY OVENS (410 & 411) HAD CHEMICAL SMELL WHEN USED. CLEANED OVENS IN AFT GALLEY REF AMM 25-31-01. OK FOR SERVICE.SDR SCNA20250116016SSmoke Detector · not reportedR AND R FWD LAVATORY SMOKE DETECTOR IAW AMM 26-14-01. OPS CHECK GOOD THIS CLEARS MEL 26-16-1.SDR SCNA20250116016Smoke Detector · false activationDEFECT 783520: FWD LAV SMOKE ALARM ON STEADY ( LAVATORY SMOKE DETECTION SYSTEMS ). RESOLUTION: (IN PROGRESS)SDR SCNA20241028336Strap · unsecureDEFECT 777940: RED EMERGENCY STRAP HANGING OUT OF EMERGENCY EXUT DOOR AT SEAT 14A. RESOLUTION: STOWED LH FWD EMRGENCY EXIT CLOSING STRAP REF AMM 52-22-00.SDR SCNA20241019332Fuel Tank · corrodedDEFECT WO FS240124: CORROSION FOUND AT LH SIDE OF THE CENTER TANK OUTER SKIN STA 663.75 UPON REMOVAL OF THE PICKEL FORK NEXT TO O/B UPPER HOLE. - - RESOLUTION: COMPLIED WITH EA 24011 REV IR AT LH SIDE OF THE CENTER TANK OUTER SKIN STA 663.75 NEXT TO O/B UPPERSDR SCNA20240716274Hook · damagedL1 GIRT BAR HOOK SWIVELS. REMOVED HOOK FASTNERS AND REINSTALLED NEW INDOOR BUSSLE (L2 SLIDE) NO CHECKS OK. SRM REF 51-40-02 JOB COMPLETE OK FOR SERVICE.SDR SCNA20241102351Elec Connector · detachedDEFECT 701688: FWD LAV SMOKE DETECTOR WENT OFF 3 TIMES ON DESCENT BELOW 10,000 FT EXTINGUISHED ITSELF EACH TIME AFTER APROX 20 SECONDS - - RESOLUTION: REMOVED SMOKE DETECTOR PANEL. PLUG THAT CONNECTS TO SMOKE DETECTOR CAME OFF. RE- CONNNECTED PLUG. NO FURTHESDR SCNA20240610251Smoke Detector · failedGROUND HANDLER REPORTED SMOKE COMING OUT OF CARGO SMOKE DETECTOR B2 AFT CARGO. R&R AFT CARGO B2 SMOKE DETECTOR PER AMM 26-16-01 AND OP CHECKS OK
A&P 4539361SDR SCNA20240506232Rivet · sheared1L GIRT BAR IS LOOSE. REMOVED AND REPLACED SHEARED RIVIT L1 DOOR BUSSEL GIRT BAR HOLDER REF AMM 25-66-01 OKAY FOR SERVICESDR SCNA20240129022SIndicator · faultedFLAPS WOULD NOT EXTEND PAST 1. MXNOTIFIED JCD 9056. - FLAP POSITION INDICATOR AND #4 SKEW SENSOR CONNECTOR REPLACED ON W/O #84678. MSG 27-53279 & 27-53280.BEGAN FIM TASK 27-51 3822.FOUND ALL EXITATION VOLTAGES GOOD AT XMITTERS AND SKEW SENSORS. W/O 84678 - R&RSDR SCNA20240129022Flap System · faultedDEFECT 768377: - - FLAPS WOULD NOT EXTEND PAST 1. MXNOTIFIED JCD 9056. - - RESOLUTION: (IN PROGRESS)SDR SCNA20231219258Unknown · unknownDEFECT 747423: R1 WINDOW OUTER PANE ARCED AND CRACKED - - RESOLUTION: REPLACED R1 WINDOW PER AMM 56-11-11. LEAK AND OPS CHECKS COMPLETED. LAND VERIFY COMPLETED PER AMM 22-11-00-700-801. OK FOR SERVICE.SDR SCNA20231030243Unknown · unknownAFT OVEN EMITS CHEMICAL SMELL WHEN IN USE LT SIDE ( NON-ESSENTIAL EQUIPMENT AND FURNISHING (NEF) )SDR SCNA20230830220Not Reported · not reportedDEFECT 744600: RH EMERGENCY LIGHT AT ROW 4 INOP. - - - RESOLUTION: REPLACED LIGHT ASSEMBLY REF AMM 33-51-03. OPS CHECK GOOD.SDR SCNA20230731205Unknown · unknownDEFECT 702518: DOOR 2R SLIDE LOOKS UNSAFE - - - RESOLUTION: RESECURED GIRT BAR VELCRO STRAPS IAW AMM REF 25-66-01 OK FOR SERVICESDR SCNA20221207150Holder · unsecureWHILE INSPECTING L1 DOOR SLIDE INSTALLATION, FOUND AFT GIRT BAR HOLDER HELD ON BY ONE RIVET. REMOVED & OPENED SLIDE ASSY FOR RIVET REPLACEMENT PER SRM 51-40-02. SECURED ASSY REF AMM 25-66-01. CHECKS OK. INSTALLED ESCAPE SLIUDE PACK AND COVER IAW AMM 25-66SDR SCNA20220622073Lens · damagedDEFECT 690301: L1 DOOR EMERGENCY EXIT LIGHT LENS DAMAGED. RESOLUTION: REPLACED L1 DOOR EMERGENCY EXIT LIGHT LENS AS NEEDED. CHECKS GOOD REF AMM 33-51-01.SDR SCNA20220427036Slide & Sleeve · jammed1R DOOR GIRT BAR HOLDER IS LOOSE . GIRT BAR NOT SECURED IN HOLDER. RESOLUTION: ADJUSTED 1R DOOR GRIT BAR HOLDER REF AMM 25-66-00SDR SCNA20220427037Door · inoperative2L DOOR SLIDE WAS FOUND UNMOUNTED. RESOLUTION: REINSTALLED 2L SLIDE DOOR PER AMM 25-66-01 OPS CHECK GOOD OK FOR SERVICESDR SCNA20210915081Support · corrodedCORROSION FLOOR TO SIDEWALL SUPPORT (ZEE CHANNEL) BS 500G + 11 TO 500I RBL 25.CORROSION ON SIDEPLATE 519-500G-500I RBL 23 FOUND TO BE OUT OF LIMITS DUE TO PROXIMITY TO FASTENER HOLD IAW SRM 53-00-53-IA-2 DERAIL "D" REV 73. REMOVED AND REPLACED SIDEPLATE WITH