What was found
DURING OPERATIONAL CHECK OF THE EMERGENCY LIGHTS, AISLE EMERGENCY LIGHTS 16RT-25RT AND 18LT-21LT-24LT-26LT DON'T TURN ON. POWER SUPPLY - BATTERY PACK M1670 WAS REPLACED PER B737-800 AMM 33-51-06 SATISFACTORY TEST
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING OPERATIONAL CHECK OF THE EMERGENCY LIGHTS, AISLE EMERGENCY LIGHTS 16RT-25RT AND 18LT-21LT-24LT-26LT DON'T TURN ON. POWER SUPPLY - BATTERY PACK M1670 WAS REPLACED PER B737-800 AMM 33-51-06 SATISFACTORY TEST