N805UA
Service difficulty reports · 117
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N805UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N805UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2013111292877Wire · failedEMERGENCY LIGHT CHECK TEST FAILED. INSTALLED JUMPER AT DOOR 1L SLIDE IAW MT33-001 & TEST PASSED. REPLACED SLIDE IAW AMM 25 62-44-400 FOR NR 1L MED. OPS CHECKED GOOD.SDR CALA2013110692700Proximity Sensor · dirtyDOOR 2R SHOWING DISARMED WITH HANDLE IN ARMED & FLASHING RED CABIN PRESSURE LIGHT. CLEANED DOOR 2R PROX SENSOR & CHECKED DOOR OPERATION OF CABIN OVERPRESSURE WARNING SYS IAW MT52-008 & ALL INDICATIONS NORMAL.SDR CALA2013102892444Wire · damagedENG 2 NO OIL PRESSURE INDICATION. AMBER CROSSES ON ECAM ENG 2. W-D 71-51-05, REPAIRED WIRE ST033W20 IAW GPM 2-0-15, IAW DF208.SDR CALA2013102592382Transmitter · faultyREVERSER FAULT DISPLAYED ON UPPER ECAM SCREEN. ENG 2 FOUND OIL PRESS XMTR FAULTING. REPLACED XMTR IAW AMM. OPERATIONS & LEAK CHECKED GOOD NO FAULTS NOTED.SDR CALA2013102492358Computer · faultyELAC 2 PITCH FAULT DISPLAYED ON UPPER ECAM SCREEN, CAME UP DURING FLAP RETRACTION FROM 1 TO 0 AFTER TAKEOFF. REPLACED ELAC 2, OPERATIONS TESTED GOOD, AFS TESTED GOOD & AUTO LAND TESTED GOOD.SDR CALA2013101592058Conduit · wornNR 2 ENG PYLON FWD FIRE BOTTLE 2 EA CONDUITS WORN AT CLAMP LOCATIONS ON OTBD SIDE OF PYLON ACCESS HOLE. REPLACE CONDUIT OF FWD BOTTLE CONNECTOR 5WE2 REF WDM 26-21-03-001.SDR CALA2013090991113Warning System · activatedSYSTEM 2 FAULT DISPLAYED ON UPPER ECAM SCREEN. - BRAKESSDR CALA2013073090066Pump · leakingGREEN SYS LOW LEVEL ECAM, FLT DIVERTED, MESSAGE FOLLOWED BY SYS LOW PRESSURE, VERIFIED HYD QTY WAS AT ZERO. REPORTED BY CREW. REPLACED NR 1 ENG HYD. PUMP, OPS, LEAK CHECKED GOOD. ALSO REPLACED NR 1 ENG HYD PRESS SWITCH AND CASE DRAIN FILTER. FOUND FILTER CLSDR UALA2013052003455Valve · faultyCREW REPORTED LOSING CABIN PRESSURE ON DESCENT. FAULTS INDICATE CABIN PRESSURE SAFETY VALVE HAS FAILED OPEN, ECAM 21-31, CABIN PRESSURE LOW DIFFERENTIAL PRESSURE, ECAM 21-31 CABIN PRESSURE SAFETY VALVE, REFER TO TSM 21-31-00-810-808, TSM 21-31-00-810-810. ACSDR UALA2013041202514Relay · faultedRT CENTER PUMP NOT SHUTTING DOWN AFTER TANK IS DRY, REPLACED RELAY 46QA IAW ASM 28-21-04.SDR UALA2013022201071Rivet · missingCREW REPORT: MISSING RIVET-UPPER PIN NIB FAIRING -OUTBOARD SIDE- NR 1 ENGINE RIVET TO BE REPLACED WITHIN 50 FLT HRS REPLACED MISSING FASTENER REF SRM 51-00.SDR UALA2013021800978Panel · damagedNR 2 AFT O/B PYLON PANEL DAMAGED. PERFORM INTERIM REPAIR IAW ECRA 5454-01067 PART 1. THIS REPAIR IS ACCEPTABLE UNTIL 11-19-13 WITH AN HFEC INSPECTION TO VERIFY A CRACK FREE CONDITION WITHIN 125 FLIGHT HOURS.SDR UALA2013012100359Battery · faultyEMERGENCY LIGHT TEST WILL NOT PASS PER 2SVC, MULTIPLE EXT LOAD MESSAGES. EPSU INT LOAD EMERGENCY LEFT, EPSU INT LOAD EMERGENCY AFT LEFT, EPSU EXT LOAD EMERGENCY RIGHT, MESSAGES ARE DISPLAYED. REPLACED BATTERY AND BULB.SDR UALA2012121207182Target · looseL-G SYS DISAGREE ECAM. FOUND LOOSE NOSE GEAR EXTENSION PROX TARGET. TIGHTENED TARGET LINK AND ADJ TARGET LINK CLEVES AS PER MM. BITE CHECK 1 AND 2 LGCIU AND PHC 1 AND 2 NO FAULTS FINAL, OPS CHECK SATISFACTORY.SDR UALA2012092405408Control Unit · malfunctionedCREW REPORTS UPPER ECAM NWS FAULT. PERFORMED FLT MNL RESET - FAULT RETURNED. POST FLT REPORT SHOWS '32-42-34 BSCU (10GC)- STEERING FDB SENSORS(3GC-4GC) SOURCE BSCU 1&2' AND '32-51-19 STEERING FEEDBACK MONITOR SENSOR (4GC) BSCU 1&2'. CHANGE BSCU1 PER 32-42SDR UALA2012091005095Warning System · false activationWHEEL N-W STRG FAULT ECAM. SYSTEM CYCLED BY FLIGHT CREW, INDICATED NORMAL REF 8622003.SDR UALA2012071103701Connector · unsecureNR 2 ENGINE ANTI-ICE VALVE FAULT, RTFL SECURED CONNECTORS 2420VC, 2421VC, 2425VC, PERFORMED OPS CK PER AMM, SYSTEM TESTED OK.SDR UALA2012051602803Line · leakingRT MLG DOOR HYD BYPASS SELECTOR VALVE LINE HAS A PINHOLE LEAK. REPLACED HYD TUBE ASSY REF IPC 32-31-03-16C ITEM 90. OP TEST MLG DOOR OK.SDR UALA2012010600144Rectifier · failedWHILE TROUBLESHOOTING ESS TRANSFORMER RECTIFIER, NR 1 TRANSFORMER RECTIFIER SHOWED LOW AMPS ON ELECTRIC PAGE. REPLACED NR 1 TRANSFORMER RECTIFIER PER MM. ENCOUNTERED ESS TRANSFORMER RECTIFIER FAULT AFTER EMERGENCY GENERATION CHECK. REPLACED ESS TRANSFORMER SDR UALA2011081804379Fitting · inoperativeSLIDE MR25622-040 RECEIVED IN PACKED CONDITION. UPON CHECKING THE BALL LOCKS ON THE ENCLOSURE ASSY, FOUND ALL THREE BALL LOCKS INOPERATIVE. THE PNEUMATIC LINE TO THE BALL LOCK ACTUATORS WAS FOUND BLOCKED FROM CORROSION IN THE ALUMINUM 90 DEGREE ELBOW FITTINGSDR UALA2011081004173Slide · faultyEMERGENCY LIGHT TEST FAILS WITH EPSU FWD LEFT EXTERNAL MESSAGE. NEEDS DOOR 1R SLIDE REPLACEMENT. REPLACED MED 1R SLIDE PER MM, EMER LIGHT TEST PASSED.SDR UALA2011062903211Tire · vibrationNOSE WHEEL CONTINUES TO ROTATE FOR 5 MINS CAUSING VIBRATION AFTER T/O. REPLACED BOTH NOSE TIRES DUE TO VIBRATION.SDR UALA2011061602966Plate · leakingPRESSURIZATION LEAK AT LOWER SCUFF PLATE DOOR 1L. FWD CORNER LEAKING AT HORIZONTAL SEAM BETWEEN FWD AND CENTER SCUFF PLATE.ALSO LEAKING AT CENTER SCUFF PLATE LOWER AFT EDGE AND AFT CORNER SCUFF PLATE LOWER EDGE. REPAIRED AREA NOTED.SDR UALA2011061302878Oxygen Mask · unsecureOXYGEN MASKS ABOVE FLIGHT ATTENDANT JUMPSEAT HAVE FALLEN AT DOOR 2R. SECURED O2 MASK DOOR 2R AND OPERATIONAL CHECK PASS OXY SYS ACCOMPLISHED PER AMM, NO DEFECTS NOTED.SDR UALA2011052302507Slide · faultyDURING OPERATIONAL TEST OF EMERGENCY LIGHT SYSTEM HAVE FAULT MESSAGE EPSU EXT. LOAD FWD L ON DISPLAY PANEL. TBSHT PER TSM NEED QUALIFICATIONS TO CONTINUE TBSHTING STEP 4B2. SUSPECT DOOR SLIDE. ACP SELF TEST ON FWD EPSU. EPSU SELF TEST FAULTS EXTERNAL LOADSSDR UALA2011031701299Controller · faultyFIRST OFFICER'S WINDSHIELD HEATING SYSTEM INOPERATIVE. SAMC TEXT: PERFORM CFDS TEST PER MM. SWAPPED WHC1 AND WHC2 FOR TROUBLESHOOTING BECAUSE CFDS TESTS PASSED ALL PHASES AND NO HEAT WAS ON THE F/O'S WINDSHIELD. AFTER THE SWAP BOTH WINDOWS HEATED NORMALLY ASDR UALA2010111504229Slide · faulty3SVC EMER LIGHT TEST SHOWS DOOR 1L SLIDE LIGHTS INOP. REPLACED SLIDE PER MM.SDR UALA2010090303250Connector · faultedVENT EXTRACT FAULT UPPER ECAM. PHASE LOW, 26 AC AT 7HQ CONTACTOR L1, PULLED BURNED WIRE FROM CONNECTOR 1278VC RED, YELLOW IN SAME CONNECTOR ALSO BURNED. CAN BE FOUND AT PANEL 107VU. CB'S A T 49VU D-6 AND 123VU AE-2 PULLED MARKED WITH ORANGE 123409 COLLARS, RESDR UALA2010090703275Slide · failedNUMBER 3 SERVICE EMERGENCY LIGHT TEST FAILED EPSU EXT LOAD FWD LT. T/S LEADS, DOOR SLIDE 1R, IAW MT. SLIDE FAILED RESISTANCE TEST. TESTED BOTH FWD DOOR SLIDES FOUND L1 TO BE CAUSING LIGHT TEST FAILURE. REPLACED L1 DOOR SLIDE. OPS CHECKED, AND PERFORMED EMESDR UALA2010051901687Slide · no testEMERGENCY LIGHT SYS TEST FAILED ON 3SV. EXTERNAL LOADS FWD L INDICATED. SLIDE WAS TESTED AND DOOR 1L SLIDE IS BAD. SLIDE IS A MR25822, 649-9130. ACFT RESTRICTED TO DAYLIGHT OPS ONLY. REPLACED DOOR 1L SLIDE. PASSED EMERGENCY LIGHT TEST.SDR UALA2010051901685Battery Pack · inoperativeEMERGENCY LIGHT SYS TEST FAILED ON 3SV RT EMERGENCY BATTERY INDICATED. REPLACE BATTERY PACK.SDR UALA2010020300438Light · no testDOOR 1L SLIDE FAILED EMERGENCY LIGHT TEST. REPLACED NR 1L DOOR MOUNTED SLIDE.SDR UALA2009101603242Slide · faultyEMERGENCY LIGHTS TEST FAIL WITH EPSU EXT LOAD FWD L. REMOVED AND REPLACED EPSU AND PWR SUPPLY, NO HELP. REMOVED AND REPLACED DOOR 1L EVAC SLIDE, OPS CHECK GOOD.SDR UALA2009081702504Slide · faultyEPSU EXT LOAD FWD LT FAULT ON EMERGENCY LIGHTS TEST. T/S FOUND DOOR NR 1 LEFT SLIDE BAD. REPLACED L1 DOOR SLIDE.SDR UALA2009081702505Bottle · low pressureDOOR 1L ASSIST BOTTLE LOW PRESSURE. REPLACED DIAPHRAGM AND O-RINGS PRESSURE GOOD.SDR UALA2009070601927Slide · faultyEPSU EXT LOAD FWD L DISPLAYED AFTER 3 SVC EMERGENCY LIGHT TEST. FOUND NR 1 RT DOOR SLIDE FAULTING. NEEDS TO BE REPLACED.SDR UALA2009060301592Gauge · leakingLOW BOTTLE PRESSURE. THERE WAS A SMALL LEAK ON THE BACK OF THE PRESSURE GAUGE. REMOVED AND REPLACED PRESSURE GAUGE AND REFILLED BOTTLE.SDR UALA2009052001442Slide · faultyEMERGENCY LIGHT SYSTEM FAILURE. DURING TROUBLESHOOTING, FOUND BOTH SLIDES ON FORWARD DOORS TO BE CAUSING THE FAILURE. NEED TO REPLACE BOTH SLIDES ON THE LEFT AND RIGHT MED. FOUND LEFT AND RIGHT FORWARD MED SLIDES TO BE CAUSING THE FAILURE. NEED TO CHANGE SSDR UALA2009041301046Battery · failedLT AFT CABIN EMERGENCY LIGHT BATTERY FAILED TEST. REPLACED LT AFT CABIN EMERGENCY LIGHT BATTERY, OPS CHECKED GOOD.SDR UALA2009041301045Battery · failedLT FWD CABIN EMERGENCY LIGHT BATTERY FAILED TEST. REPLACED LT FWD CABIN EMERGENCY LIGHT BATTERY, OPS CHECKED GOOD.SDR UALA2009010500050Filter · dirtyOILY ODOR COMING FROM PACK 1, AFFECTING CABIN AIR QUALITY. ACCOMPLISHED HIGH POWER RUN ON NR 1 AND NR 2 ENGINES, ISOLATING PACKS AND BLEEDS. NO OIL OR BURNING ODOR NOTICED. REPLACED RECIRCULATING FILTERS.SDR UALA2008111806555Bottle · low pressureDOOR 1R SLIDE BOTTLE PRESSURE IS LOW. ACCOMPLISHED CHECK OF SLIDE PRESSURE. SLIDE PRESSURE GAUGE IN LOWER LIMITS OF GREEN BAND.SDR 2008UALA06479Mount Fitting · crackedR2 DOOR SLIDE LOWER FWD MOUNT FITTING IS CRACKED. REPLACED SLIDE.SDR 2008UALA04343Slide · faultyTHE 'ESPU EXT LOAD FWD L' FAULT DISPLAYED ON PTP DISPLAY DURING EMERGENCY LIGHTING TEST. ISOLATED FAULT TO DOOR 1R ESCAPE SLIDE. INSTALLED NEW SLIDE PACK (MR25611) AT DOOR 1R.
SDR 2008UALA04291Light · inoperativeEMERGENCY LIGHT AT SEAT 7C INOP. *S/D* REPLACED LIGHT ASSY, OKAY FOR SERVICE.SDR 2008UALA03848Wire Harness · shortedDURING 3SV EMERGENCY LIGHTING SYSTEM TEST EPSU EXT LOAD FWD L DISPLAYED. TEST ON FWD L POWER SUPPLY HAS SAME FAULT. FOUND SHORT IN HARNESS IN DOOR 1L SLIDE PACK. REPLACED DOOR 1L SLIDE PACK, OPS CHECKED NORMAL.
SDR 2008UALA02901Servo · failedELEV SERVO FAULT DISPLAYED ON UPPER ECAM SCREEN. - F -CTL ELEV SERVO FAILURE. REPLACED 3EC1 LT INBOARD SERVO CONTROL, ALL OPS CHECKS NORMAL.SDR 2008UALA02054Floorbeam · corrodedFLOORBEAM CORRODED AT FWD GALLEY. MAJOR REPAIR. REPLACED OR REWORK OF CORROSION ACOMP ON SFOOV, BEAM INSTL, INSTG NUT PLATES AND PREPPING FLOOR BOARDS.SDR 2008UALA01631Light · no test3SV EEL LIGHT FAP TEST FAILED EPSU EXT LOAD FWD L. CAUSE, ELECTRICAL SHORT IN SLIDE NR 1 LT MED SLIDE. REPLACED SLIDE NR 1 LT MED. OPS CHECKED NORMALLY.SDR 2008UALA00438Fitting · out of adjustTRYING TO INSTALL NEW SLIDE DOOR 2R. GIRT BAR WILL NOT ALIGN WITH PINS. SUSPECT GIRT GAR FITTINGS OR EMERGENCY CONTROL HANDLE OUT OF RIG. *S/D* GIRT BAR FITTING OUT OF ADJUSTMENT. ADJUSTED GIRT BAR FITTING, SYSTEM OPS CHECKED NORMALLY.
Back to N805UA