N815NN
Service difficulty reports · 111
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N815NN' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N815NN' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA202111015225Skin · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK IN SKIN OF LH HORIZONTAL STABILIZER AT STA 138.70, 25.00 IN AFT OF FRONT SPAR, MEASURING L=1.0 IN, W=0.004 IN, D=0.065 IN. ACCOMPLISHED PERMANENT REINFORCING DOUBLER REPAIR IAW SRM 55-10-01-2R-11.SDR AALA202111013883Skin · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK IN LOWER SKIN OF RH HORIZONTAL STABILIZER AT STA 92.70, 30.00 IN AFT OF FRONT SPAR, MEASURING L=2.0 IN, W=0.004 IN, D=0.071 IN. ACCOMPLISHED PERMANENT REINFORCING DOUBLER REPAIR IAW SRM 55-10-01-2R-11.SDR AALA202112038677Rib · crackedAIRCRAFT IN BASE MAINTENANCE: RIGHT HAND HORIZONTAL STABILIZER CRACKED RIB LOCATED AT STABILIZER STA 129.5, AT THIRD STIFFENER. REPAIRED RIB PER SRM 55-10-09-2R-4SDR AALA202112030612Rib · crackedAIRCRAFT IN BASE MAINTENANCE: RIGHT HAND HORIZONTAL STABILIZER CRACKED RIB LOCATED AT STABILIZER STA 92.70, AT SECOND AND THIRD STIFFENERS. REPAIRED RIB PER SRM 55-10-09-2R-4.SDR AALA202112088546Floor Support · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK IN FLOORBOARD SUPPORT AT STA 540 BETWEEN BL 0 AND LBL 23, MEASURING L=1.0 IN, W=1.0 IN, D=0.04 IN. REPLACED FLOORBOARD SUPPORT WITH NEW IAW AARD 51-00-05.SDR AALA202110287973Skin · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK INDICATION IN SKIN OF LH HORIZONTAL STABILIZER AT STA 92.70, 24.00 IN AFT OF FRONT SPAR, MEASURING L=0.75 IN, W=0.003 IN, D=0.071 IN. ACCOMPLISHED PERMANENT REINFORCING DOUBLER REPAIR IAW SRM 51-10-01-2R-11.SDR AALA202110282338Floorboard · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK FOUND ON FLOORBOARD SUPPORT LOCATED AT STA 540, AND BETWEEN RIGHT BUTT LINE 0 TO 23. REMOVED AND REPLACED FLOORBOARD SUPPORT PER AARD 51-00-05.SDR AALA202112064730Floor Support · corrodedAIRCRAFT IN BASE MAINTENANCE: FALSE AFT BULKHEAD FRAME HAS MULTIPLE CORROSION SPOTS AT RIGHT LEFT AND CENTER. INSTALLED AFT LOWER BULKHEAD SUPPORT ANGLE STA 500I PER SRM 51-40-02.SDR AALA202112067708Transition Panel · corrodedAIRCRAFT IN BASE MAINTENANCE: FORWARD CARGO TRANSITION PANEL LEFT HAS CORROSION SPOTS AT STATION 500E TO 500F. INSTALLED NEW LEFT TRANSITION PANEL AND SPLICES STA408-STA500E+10 PER SRM 53-00-53-2R.SDR AALA202112068979Transition Panel · corrodedAIRCRAFT IN BASE MAINTENANCE: FORWARD CARGO TRANSITION PANEL RIGHT HAS CORROSION SPOTS AT STA 500G TO 500H. REPLACED RIGHT TRANSITION PANEL PER SRM 53-00-53-2R-5.SDR AALA202112060382Transition Panel · corrodedAIRCRAFT IN BASE MAINTENANCE: FORWARD CARGO TRANSITION PANEL RIGHT HAS CORROSION SPOTS AT STATION 500 E TO 500 F. RIGHT TRANSITION PANEL REPLACED PER SRM 53-00-53-2R-5.SDR AALA202112038091Angle · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION OF Z ANGLE IN AFT WET AREA FLOOR STRUCTURE AT STA 990 AND LBL 32, MEASURING L=1.0 IN, W=1.0 IN, D=0.03 IN. REPLACED Z ANGLE WITH NEW IAW SRM 51-40-02.SDR AALA202112034946Transition Panel · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION OF TRANSITION PANEL IN FWD CARGO AT STA 508 AND STR 26L, MEASURING L=1.0 IN, W=0.75 IN, D=0.002 IN. REPLACED TRANSITION PANEL WITH NEW IAW SRM 53-00-53-2R-5.SDR AALA202112030899Transition Panel · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION OF TRANSITION PANEL IN FWD CARGO BETWEEN STA 500C AND STA 500D AT STR 25R, MEASURING L=1.0 IN, W=2.0 IN, D=0.012 IN. REPLACED TRANSITION PANEL WITH NEW IAW SRM 53-00-53-2R-5.SDR AALA202112033944Transition Panel · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION MEASURING L=1.00 IN, W=2.00 IN, D=0.022 IN, ON FORWARD CARGO LEFT HAND TRANSITION PANEL LOCATED BETWEEN STA 408 AND STA 500E AT S26L. REPLACED TRANSITION PANEL PER SRM 53-00-53-2R PROCEDURE 5 AND AARD 51-00-05-1A.SDR AALA202112037780Transition Panel · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION MEASURING L=0.5 IN, W=0.5 IN, D=0.038 IN, ON FORWARD CARGO LEFT TRANSITION PANEL LOCATED BETWEEN STA 408 AND STA 500E AT S26L. REPLACED TRANSITION PANEL PER SRM 53-00-53-2R PROCEDURE 5 AND AARD 51-00-05-1ASDR AALA202111092898Transition Panel · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION OF TRANSITION PANEL IN FWD CARGO AT STA 500B AND STR 26L, MEASURING L=1.0 IN, W=0.5 IN, D=0.007 IN. REPLACED TRANSITION PANEL WITH NEW IAW SRM 53-00-53-2R-5. PREVIOUSLY SUBMITTED ON AALA202111088247.SDR AALA202111092958Transition Panel · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION OF TRANSITION PANEL IN FWD CARGO BETWEEN STA 500B AND STA 500C AT STR 26L, MEASURING L=0.75 IN, W=0.75 IN, D=0.038. REPLACED TRANSITION PANEL WITH NEW IAW SRM 53-00-53-2R-5. PREVIOUSLY REPORTED ON AALA202111089304.SDR AALA202111098310Transition Panel · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION OF TRANSITION PANEL IN FWD CARGO BETWEEN STA 500D AND STA 500E AT STR 26L, MEASURING L=1.25 IN, W=0.625 IN, D=0.032 IN. REPLACED TRANSITION PANEL WITH NEW IAW SRM 53-00-53-2R. PREVIOUSLY REPORTED ON AALA202111080646.SDR AALA202111080646Transition Panel · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION OF TRANSITION PANEL IS FWD CARGO BETWEEN STA 500D AND STA 500E AT STR 26L, MEASURING L=1.25 IN, W=0.625 IN, D=0.032 IN. REPLACED TRANSITION PANEL WITH NEW IAW SRM 53-00-53-2R-5.SDR AALA202111089304Transition Panel · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION OF TRANSITION PANEL IN FWD CARGO BETWEEN STA 500B AND STA 500C AT STR 26L, MEASURING L=0.75 IN, W=0.75 IN, D=0.038 IN. REPLACED TRANSITION PANEL WITH NEW IAW SRM 53-00-53-2R-5.SDR AALA202111088247Transition Panel · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION OF TRANSITION PANEL IN FWD CARGO AT STA 500B AND STR 26L, MEASURING L=1.0 IN, W=0.5 IN, D=0.007 IN. REPLACED TRANSITION PANEL WITH NEW IAW SRM 53-00-53-2R.SDR AALA202111055229Transition Panel · corrodedAIRCRAFT IN BASE MAINTENANCE: FORWARD CARGO TRANSITION PANEL RIGHT HAS CORROSION SPOTS AT STA 500F TO 500G. REMOVED AND REPLACED RIGHT TRANSITION PANEL PER 53-00-53-2R-5.SDR AALA202111050011Transition Panel · corrodedAIRCRAFT IN BASE MAINTENANCE: FORWARD CARGO TRANSITION PANEL RIGHT HAS CORROSION SPOTS AT STA 500D TO 500F. REMOVED AND REPLACED RIGHT TRANSITION PANEL STA 500A TO 500I PER SRM 53-00-53-2R.SDR AALA202111058798Transition Panel · corrodedAIRCRAFT IN BASE MAINTENANCE: FORWARD CARGO TRANSITION PANEL RIGHT HAS CORROSION SPOTS AT STA 500A TO 500B. REMOVED AND REPLACED RIGHT TRANSITION PANEL STA 500A - 500I PER SRM 53-00-53-2R.SDR AALA202111044793Transition Panel · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION OF RH TRANSITION PANEL IN FWD CARGO BETWEEN STA 500H AND STA 500I AT STR 25R, MEASURING L=1.0 IN, W=2.0 IN, D=0.012 IN. REPLACED TRANSITION PANEL WITH NEW IAW SRM 53-00-53-2R.SDR AALA202110289234None · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION OF LH CREASE ANGLE IN AFT WET AREA FLOOR STRUCTURE BETWEEN STA 947 AND STA 986 AT LBL 45, MEASURING L=4.0 IN, W=2.0 IN, D=0.03 IN. REPLACED CREASE ANGLE WITH NEW IAW AARD 51-00-05-1.SDR AALA202110281829Floor Support · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION OF FLOOR SUPPORT IN AFT WET AREA BETWEEN STA 947 AND STA 967 AT LBL 51, MEASURING L=1.25 IN, W=1.25 IN, D=0.049 IN. REPLACED FLOOR SUPPORT WITH NEW IAW AARD 51-00-05-1.SDR AALA202110281995Transition Panel · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION OF LH TRANSITION PANEL BETWEEN STA 727G AND STA 780 AT STR 25L, MEASURING L=1.0 IN, W=1.0 IN, D=0.031 IN. REPLACED TRANSITION PANEL WITH NEW IAW SRM 53-140-00.SDR AALA202110190323Channel · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION OF Z-CHANNEL NEAR FASTENER HOLES AT STA 990 BETWEEN RBL 34 AND RBL 47, MEASURING L=1.0 IN, W=1.25 IN, D=0.02 IN. REPLACED Z-CHANNEL WITH NEW IAW AARD 51-00-05 AND SRM 51-40-02.SDR AALA202108169905Handle · faultyAIRCRAFT WAS NOT GROUNDED: AFT LAVATORY D, DOOR WILL NOT OPEN FULLY. **SUPPLEMENTAL REPORT FOR AALA202108129905: REPLACED DOOR HANDLE PER CMM 25-40-64.** (CLOSED)SDR AALA202108129905Door · bindingAIRCRAFT WAS NOT GROUNDED: AFT LAVATORY D, DOOR WILL NOT OPEN FULLY. (OPEN)SDR AALA202107224137Door · stickingAIRCRAFT WAS NOT GROUNDED: LAVATORY DOOR IN FORWARD CABIN IS DIFFICULT TO OPEN AND CLOSE. ADJUSTED DOOR PER AMM 52-05-03.SDR AALA202101199008Smoke Detector · false activationAIRCRAFT WAS NOT GROUNDED. MOMENTARY LAVATORY SMOKE INDICATION IN LAVATORY E. ALSO LAVATORY SMOKE LIGHT ON OVERHEAD PANEL ILLUMINATED. REPLACED LAVATORY SMOKE DETECTOR, IAW AMM 26-14-01. OPERATIONS CHECK GOOD.SDR AALA202010219018Floor Panel · damagedAIRCRAFT WAS GROUNDED. MAIN CABIN CENTER AISLE FLOOR PANEL SOFT AND POPPING BETWEEN SEAT ROW 15 AND ROW 18. REPAIRED FLOOR PANEL, PER AARD 53-00-00-6.SDR AALA202010029007Cover · unsecureAIRCRAFT WAS NOT GROUNDED: LIGHT LENS/COVER/BEZEL DAMAGED. EXIT LIGHT CAP FOR AFT SERVICE DOOR FELL OFF. REMOVE AND REPLACED LIGHT LENS COVER ASSEMBLY EXIT LIGHT PER AMM 33-51-01.SDR AALA202007289010Guide Arm · looseAIRCRAFT WAS GROUNDED: L1 DOOR DIFFICULT TO OPEN. INSTALLED NEW SCREW AND WASHER ON L1 DOOR GUIDE ARM PER AMM 52-11-21-400-802.SDR AALA2020072319015Starter Gen · burnedAIRCRAFT WAS GROUNDED: ON APU POWER- ALL AC BUSSES TRIPPED OFF AND STRONG ELEC SMOKE SMELL FOR APPROX 1 MINUTE. NO COCKPIT C/BS POPPED. APU OPERATION NORMAL. SMOKE/BURN SMELL THROUT ENTIRE CABIN. MEL 07-1260DC-C. UPON FURTHER INSPECTION FOUND APU STARTER GENESDR AALA2020021109054Trim Motor · failedAIRCRAFT WAS GROUNDED: DIVERTED JFK ACCOUNT FLAP OVERSPEED STABILIZER TRIM ISSUE. STABILIZER TRIM INOPERATIVE. ON GO AROUND STAB TRIM FAILED. COMPLIED WITH QRH PROCEDURE - STAB TRIM, CUT-OUT SWITCHES LEFT IN CUT-OUT. EMERGENCY DEALARED. REMOVED AND REPLACED STSDR AALA201904299002Heater · fodAIRCRAFT WAS GROUNDED: F/A'S REPORTED WHITE SMOKE AND STRONG ELECTRICAL BURNING SMELL FROM AFT GALLEY. RAN QRH SMOKE/FIRE/FUMES CHECKLIST SMOKE DISSIPATED. MAINTENANCE FOUND DEBRIS IN THE AFT DOOR AREA HEATER. REMOVED AND REPLACED THE HEATER. OPS TEST GOOD IAWSDR AALA20171002006Floor Support · crackedCRACKED FLOOR SUPPORT BETWEEN BS 312 AND 328 AT LBL 46. REMOVED AND REPLACED THE FLOOR SUPPORT IAW D 51-00-05-1 AND DRAWING 141A5400.SDR AALA201708029016Sign · unsecureTHE AIRCRAFT WAS NOT GROUNDED. FA ADVISED THE EMERGENCY EXIT SIGN FOR R-2 HAS FALLEN. REMOVED AND REPLACED R-2 EMERGENCY EXIT LIGHT ASSY. IAW AMM 33-51-01 OPS CHECKED OK.SDR AALA201705109028Fire Bottle · leakingWHILE AT CRUISE FL350, THE FLT DECK HALON FIRE EXTINGUISHER SPRUNG AN UNCONTROLLABLE LEAK. THE FLIGHT CREW DONNED THEIR O2 MASKS. A JUMPSEAT PILOT REMOVED THE EXTINGUISHER FROM THE COCKPIT AND MOVED IT INTO THE FORWARD LAVATORY. THE LAVATORY REMAINED CLOSED UNSDR AALA20170206015Lens · detachedEMERGENCY EXIT LIGHT NEAR THE FORWARD GALLEY HAS A DETACHED LENS. INSTALLED THE LENS IAW AMM 33-51-01. OPS CHECKED GOOD.SDR AALA20170131006Handle · looseAIRCRAFT WAS NOT GROUNDED. R1 DOOR ASSIST HANDLE IS LOOSE. RESECURED HUB BOLTS IAW AMM 52-11-11. OPERATIONAL CHECK GOOD.SDR AALA20161101015Power Supply · failedAIRCRAFT NOT GROUNDED. RIGHT AFT EMERGENCY LIGHTS FAILED 15 MINUTE TEST. REMOVED AND REPLACED EMERGENCY LIGHTS POWER SUPPLY. OPERATIONAL CHECK GOOD.SDR AALA20160429007Girt Bar · jammedAIRCRAFT WAS NOT GNDED. CABIN CREW WAS UNABLE TO REMOVE R1 DOOR GIRT BAR FROM STOWAGE HOOKS TO ARM DOOR. FOUND GIRT BAR IMPROPERLY STOWED. OFFSET TO ONE SIDE RESULTING IN BAR BEING JAMMED. UNJAMMED GIRT BAR.SDR AALA20151029004Floorbeam · corrodedCORROSION ON FLOORBEAM AT STATION 947, RBL 50. REPAIRED IAW SRM 53-00-51-2R PROCEDURE 1, SRM 53-70-51-2R-5, SRM 51-20-01-0G, SRM 51-40-02 & DWG 147A0000.SDR AALA20151029002Floorbeam · crackedDURING ACCOMPLISHMENT OF ECO J1698, HFEC ON HOLES AT 727B, LBL 24 - 45, & 727B, RBL 24 - 45 FOUND CRACKS. REPAIRED STATION 727B FLOORBEAMS IAW ECO J1698 & EA 255481.SDR AALA20151028002Web · corrodedFLOOR WEB CORRODED AT STATION 988, RBL 33 - 38. INSTALLED DOUBLER REPAIR IAW SRM 51-70-13.
Back to N815NN