N819AW
Service difficulty reports · 238
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N819AW' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N819AW' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR USAA2010070691339Actuator · defectiveFLT 622 OAK - PHX - REJECTED TAKEOFF - CREW RECEIVED NR 1 ENGINE COMPRESSOR VANE FAULT ON TAKEOFF ROLL, REJECTED TAKEOFF AT 90-100 KNOTS. SAME EVENT OCCURRED ON THE FOLLOWING DAY AND CREW REJECTED TAKEOFF AT 80 KNOTS. MAINTENANCE REMOVED AND REPLACED THE NR SDR USAA2010011590115Lens · missingFLT NR 468 - EMERGENCY EQUIPMENT, EMERGENCY EXIT LENS MISSING AT LEFT SIDE OVERWING DOOR. INSTALLED NEW EMERGENCY LIGHT LENS AT LEFT SIDE OVERWING DOOR.SDR USAA2009022090394Cylinder · low pressurePIT - A13 - EES - FOUND L2 DOOR EMERGENCY CYLINDER/ACCUMULATOR PRESSURE LOW. SERVICED TO OPERATING PRESSURE IAW TASK CARD 52-10-00-790-001.SDR USA09021690344Thermostat · faultyDIVERSION - 0327ZF152 LOST BOTH ENGINE BLEEDS, DIVERTED. AIR ENG BLEED NR 2 FAULT. REMOVED AND REPLACED NR 2 ENG TEMP CONTROL THERMOSTAT. OPS CHECK WAS GOOD. (K)SDR USA09021690343Thermostat · faultyDIVERSION - 03272F152 LOST BOTH ENGINE BLEEDS, DIVERTED. AIR ENGINE BLEED 1 FAULT. REMOVED AND REPLACED NR 1 ENGINE TEMP CONTROL THERMOSTAT. OPS CHECK WAS GOOD. (K)SDR USAA2008123192365Battery · dischargedLOGPAGE: 8367520 - FLT 178 - SFO-LAS- EEL - FLASHLIGHT UNDER FORWARD INBOARD FLIGHT ATTENDANT JUMPSEAT INOPERATIVE. REMOVED AND REPLACED FLASHLIGHT BATTERY. OPERATIONAL CHECK WAS GOOD.SDR USAA920081597Battery · dischargedLOGPAGE 8047440 FLT NR 4 ORD PHX EEL OUTBOARD FORWARD FLIGHT ATTENDANT FLASHLIGHT NOT BLINKING. R&R BATTERY. OPS CHECK WAS GOOD.SDR USAA920081391Power Supply · dischargedFLT 580 LAS-JFK - EEL - EMERGENCY EXIT LIGHTS INOP. BATTERY DISCHARGED. MAINTENANCE REMOVED AND REPLACED THE RT AND LT BATTERY CHARGERS AND BATTERIES. OPERATIONAL CHECK WAS NORMAL. POWER SUPPLE/MFGR DIEHL / P/N 3214-54 / S/N 6067 / DISCHARGED / ZONE 200 FUSDR AWXA200700859Battery · failedPHX - EEL - LOG NR 3927277 - PASSENGER EMERGENCY LIGHTS BATTERY FAILED TEST, CENTER LT SIDE. MX REPLACED EMERGENCY LIGHTS BATTERY. OPERATIONAL CHECK WAS GOOD.SDR AWXA200601716Connector · looseLAS - EEL - DURING ROUTINE MAINTENANCE IT WAS DISCOVERED THAT THE EMERGENCY LIGHT TEST, LEFT EXTERIOR LIGHT FAILED. MX DISCOVERED THE CONNECTOR ON THE LT SIDE NOT FULLY CONNECTED. MX RESECURED THE CONNECTOR. OPS CHECK WAS GOOD.SDR AWXA200601634Battery Pack · inoperativeLAS - EEL - DURING OVERNIGHT IT WAS DISCOVERED THAT SEVERAL SEAT EMERGENCY LIGHTS WERE INOP WITH C/BS H05 AND H06 PULLED. MAINTENANCE REPLACED THE BATTERY PACK AT THE LEFT MID CABIN EPSU PER A1C33302. OPS CHECK GOOD.SDR AWXA200601023Floor Support · corrodedSAL - DURING BC4 CHECK DISCOVERED CORROSION ON FLOORBEAM AT FLOOR STRUCTURE IN PAX CABIN AT Y-1292 AT FS 66. BEAM WAS REMOVED AND REPLACED FROM FS 64 TO FS 66+5" AT Y-1292 IAW AIRBUS 329 SRM 51-72-11.SDR AWXA200601021Floor Panel · corrodedSAL - DURING BC4 CHECK DISCOVERED CORROSION IN FLOOR PANEL 222FF OF CABIN ENTRANCE R1 DOOR LOWER SURFACE. MAINTENANCE REMOVED AND REPLACED FLOOR PANEL 222FF IAW AMERICA WEST AIRLINES TASKCARD C1D25306.SDR AWXA200601029Floor Panel · corrodedSAL - DURING BC4 CHECK DISCOVERED CORROSION ON FLOOR PANEL, 261FF, IN THE AFT GALLEY AREA FROM FS 66 TO FS 68 BETWEEN STRINGER 19L AND STR 20L. MAINTENANCE REMOVED AND REPLACED FLOOR PANEL 261FF IN AFT GALLEY AREA AT FR66 TO FR 68 BETWEEN STR 19L AND STR 20L SDR AWXA200601020Floorbeam · crackedSAL - DURING BC4 CHECK DISCOVERED CRACK IN HOLE OF CABIN FLOOR SUPPORT AT FR 18+4" AND Y1292. MAINTENANCE REPAIRED CABIN FLOOR SUPPORT BEAM AT FR 18+4" AND Y1292 IAW AIRBUS 319 SRM 53-11-14 FIG 201.SDR AWXA200601019Floor Support · corrodedSAL - DURING BC4 CHECK DISCOVERED CORROSION ON FLOOR SUPPORT AT FLOOR STRUCTURE IN PAX CABIN AT Y1292 AND FS 68. FLOORBEAM AT FLOOR STRUCTURE IN PAX CABIN AT Y1292 BETWEEN FS 68 AND FS 69 REPLACED IAW AIRBUS 319 SRM 51-72-11.SDR AWXA200601018Floor Support · corrodedSAL - DURING BC4 CHECK DISCOVERED CORROSION ON FLOOR SUPPORT AT FLOOR STRUCTURE IN PAX CABIN AT FS 67-1", +2", +6", +10" AND +13" AT Y1292. MAINTENANCE REMOVED AND REPLACED FLOORBEAM IN PAX CABIN BETWEEN FS 66 TO FS 68 AT Y1292 IAW AIRBUS 319 SRM 51-72-11 PAGSDR AWXA200601028Floor Panel · delaminatedSAL - DURING BC4 CHECK DISCOVERED CORROSION ON UPPER SURFACE OF FORWARD CARGO FLOOR PANEL, 131CG, AND DELAMINATED OUT OF LIMITS. MAINTENANCE REMOVED AND INSTALLED FABRICATED FLOOR PANEL, 131CG, IAW IRM 9704 REV F.SDR AWXA200601017Plate · corrodedSAL - DURING BC4 CHECK DISCOVERED CORROSION IN PLATE ASSY NUT OF GIRT BAR FITTING AT FS 16 LOWER SILL OF THE L1 DOOR. MAINTENANCE REMOVED AND REPLACED THE PLATE ASSY NUT OF GIRT BAR FITTING AT FS 16, LOWER SILL OF L1 DOOR IAW AIRBUS 319 SRM 51-72-11.SDR AWXA200601027Sill · corrodedSAL - DURING BC4 CHECK DISCOVERED LEVEL 2 GALVANIC CORROSION ON LOWER SILL BEAM AT FLOOR STRUCTURE IN PAX CABIN AT FR 66 AND Y-1732. CORROSION WAS FOUND TO BE OUT OF LIMITS IAW AIRBUS 319 SRM 53-41-14 FIG 101. MAINTENANCE CUT OUT AND REMOVED DAMAGED AREA IAWSDR AWXA200601026Sill · corrodedSAL - DURING BC4 CHECK DISCOVERED LEVEL 2 GALVANIC CORROSION ON LOWER SILL BEAM AT FLOOR STRUCTURE IN PAX CABIN AT FS 66 AND Y1732. CORROSION WAS FOUND TO BE OUT OF LIMITS IAW AIRBUS 319 SRM 53-41-14 FIG 101. MAINTENANCE CUT OUT AND REMOVED DAMAGED AREA IAW SDR AWXA200601016Web · corrodedDURING BC4 CHECK DISCOVERED CORROSION ON WEB AT FLOOR STRUCTURE IN PAX CABIN BETWEEN FR 69 AND FR70 AT Y1292. MAINTENANCE REMOVED AND REPLACED WEB AT Y1292 FROM FR69 TO FR70 IAW A319 SRM 51-72-11.SDR AWXA200601015Seat Track · corrodedSAL - DURING BC4 CHECK DISCOVERED CORROSION ON DUMMY RAIL IN THE CABIN AT FR 14+6" AND AT Y503.2. CORROSION WAS FOUND TO BE OUT OF LIMITS IAW A319 SRM 53-11-14. MAINTENANCE REMOVED AND INSTALLED FORMED DUMMY RAIL FROM FR12 TO FR16 AT Y503.2 IAW A319 SRM DRAWSDR AWXA200600985Floorbeam · corrodedDURING BC4 CHECK DISCOVERED CORROSION ON FLOORBEAM AT FLOOR STRUCTURE IN PAX CABIN AT Y-1292, FR68 AND FR68-4. CORROSION WAS FOUND TO BE OUT OF SRM LIMITS. MAINTENANCE REMOVED AND REPLACED FLOOR BEAM IN PASSENGER CABIN AT Y-1292 AND FROM FR 68 TO FR 69 IAW ASDR AWXA200601014Seat Track · corrodedSAL - DURING BC4 CHECK DISCOVERED CORROSION ON SEAT TRACK ON FLOOR STRUCTURE IN PAX CABIN AT Y-1292 FR36+3", FR 38+7. MAINTENANCE REMOVED AND REPLACED THE SEAT TRACK IN THE PAX CABIN AT Y-1292 FROM FR 36 TO FR 41 IAW AIRBUS 319 SRM 51-72-11 PAGES 1-2.SDR AWXA200601013Seat Track · corrodedSAL - DURING BC4 CHECK DISCOVERED CORROSION ON SEAT TRACK ON FLOOR STRUCTURE IN PAX CABIN AT Y765 FR36, 38+6" AND FR40. MX REMOVED AND REPLACED THE SEAT TRACK IN THE PAX CABIN AT Y 765 FROM FR36 TO FR41 IAW AIRBUS 319 SRM 51-72-11 PAGES 1-2.SDR AWXA200601012Seat Track · corrodedSAL - DURING BC4 CHECK DISCOVERED CORROSION ON SEAT TRACK ON FLOOR STRUCTURE IN PAX CABIN AT Y765 FR43+4", FR44 AND FR46+8". MAINTENANCE REMOVED AND REPLACED THE SEAT TRACK IN THE PAX CABIN AT Y 765 FROM FR 41 TO FR 47 IAW AIRBUS 319 SRM 51-72-11 PAGES 1-2.SDR AWXA200600610Battery · inoperativePHX - EEL - DURING OVERNIGHT MAINTENANCE THE EMERGENCY LIGHT SYSTEM WAS FAULTING. MAINTENANCE REMOVED AND REPLACED THE AFT LEFT EMERGENCY BATTERY. OPERATIONAL TESTS WERE GOOD.SDR AWXA200600204Extinguisher · emptyPHX - EMERGENCY EQUIPMENT, CREW REPORTED THAT THE LAV D FIRE EXTINGUISHER WAS FOUND EMPTY; THE INDICATOR WAS IN THE RED BAND. MAINTENANCE INSPECTED AND FOUND NO SIGN OF DISCHARGE. REMOVED AND REPLACED THE LAV D FIRE EXTINGUISHER.SDR AWXA200501328Coffeemaker · smokeSJC - SMOKE - FLIGHT ATTENDANT REPORTED A BURNING SMELL IN AFT GALLEY, FOLLOWED BY SMOKE. GALLEY C/B'S WERE PULLED AND WHEN THE 3RD COFFEEMAKER C/B WAS PULLED, SMOKE CEASED. 3RD COFFEE MAKER IS CURRENTLY ON MEL. MAINTENANCE REPLACED THE AFT NR 3 COFEEMAKER.SDR AWXA200501092Fmu · malfunctionedCREW REPORTED THAT DURING TAKE OFF, NR 2 ENGINE SPOOLED MUCH SLOWER THAN NR 1. ABORTED TAKEOFF AT 30 KNOTS & RETURNED TO GATE WITHOUT FURTHER INCIDENT. MX R & R LP/HP FUEL PUMP IAW AMWEST TASK CARD R5M73304. ALSO R & R FUEL FLOW METERING UNIT IAW AWA TASKSDR AWXA200500804Battery · dischargedPHX - EEL - SEVERAL EMERGENCY EXIT LIGHTS IN AFT CABIN FAILED DURING EMERGENCY LIGHTS TEST DURING 4 DAY CHECK. MAINTENANCE REMOVED AND REPLACED THE BATTERY IN THE EPSU 13WL IAW AMERICA WEST AIRLINES TASKCARD A1C33302.SDR AWXA200401411Battery · dischargedDURING 4-DAY CHECK THE AFT GALLEY EMERGENCY FLASHLIGHT WAS FOUND INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE AFT GALLEY EMERGENCY FLASHLIGHT BATTERY, OPERATIONAL CHECK WAS GOOD.SDR AWXA200400764Adiru · failedAIR TURN BACK, ON CLIMB OUT, EN ROUTE, RECEIVED ADR NR 1 FAULT MESSAGE, SWITCHED TO ADR NR 3 AND LOST NAV DISPLAY AND PRIMARY FLIGHT DISPLAY INTERNAL REF INFO, TURNED BACK FOR REPAIR. MAINTENANCE REMOVED AND REPLACED NR 1 AIR DATA INERTIAL REFERENCE UNIT (ADIRSDR AWXA200300973Proximity Sensor · defectiveFLIGHT CREW REPORTED THE L-2 DOOR SLIDE WOULD NOT ARM FOR DEPARTURE. MAINTENANCE REMOVED AND REPLACED THE L-2 DOOR SLIDE ARM PROXIMITY SENSOR (7WN1) IAW AMM 52-73-11-401, OPERATIONAL TEST WAS GOOD.SDR AWXA200300814Wire Harness · arcedFLT 0002 -AT CRUISE RECEIVED MASTER CAUTION AND ECAM MSG FOR BLUE HYD SYS LOW PRESS, NOSE WHEEL STEERING (NWS), AVIONICS VENT FAULT, PRIMARY FLT DISPLAY (PFD), NAV DISPLAY (ND), FREQ CNTRL UNIT (FCU), GEN NR 1, BTRY NR 2, CABIN LIGHTS. DECLARED EMER AND DIVERTSDR AWXA200201239Power Supply · dischargedLAS - EEL - RECEIVED "NO COMMUNICATION" MESSAGE WHILE PERFORMING BITE TEST OF EMERGENCY LIGHTS. MAINTENANCE REMOVED AND REPLACED EMERGENCY POWER SUPPLY UNITS 10WL, 11WL, 12WL, AND 13WL IAW AMM 33-51-38, OPERATIONAL CHECK WAS GOOD.SDR AWXA200200250Reservoir · brokenPHX - ESCAPE SLIDE - "C" - DURING P-09 INSPECTION THE R/H OVERWING ESCAPE SLIDE BOTTLE CABLE WAS FOUND BROKEN AT THE HOOK UP POINT. MAINTENANCE REMOVED AND REPLACED THE R/H OVERWING SLIDE BOTTLE ASSEMBLY AND RESERVOIR IAW AMM 25-62-46-800-001.