N827SY

Service difficulty reports · 39

Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE n_number = 'N827SY' AND registry_match = 'registration'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR SCNA20260921404Liner · out of adjustFLIGHT ATTENDANT'S REPORT LOUD AIR NOISES IN EMERGENCY EXIT AREA. UNSURE IT IS THE DOORS OR DUCTS. PERFORMED ADJUSTMENT TEST OF BOTH LEFTHAND EMERGENCY EXIT DOORS WITH NO DISCREPENCIES NOTED IAW AMM 52-22-00 FOUND THE DOOR LINER HINDERING DOOR OPERATION ADJUSTSep 18, 2026 · N827SY · Boeing 7378F2 · Emergency ExitsSDR SCNA20260902378Repair · corrodedREPLACE REPAIR IAW MESSAGE MM 4-SCA-26-0018 ON STRINGER U-9 BETWEEN BTW RIB 19 AND 20 WSTA 564.5 TO 591.5 RT WING, THE NEW REPAIR MUST BE PERFORMED IAW BOEING MSG MM4-SCA-26-0018 BTWN RIB 18 AND 19 WSTA WSTA 537.5 TO 564.5 STRINGER U-9 RH WING. - - SUMMARY: REJul 3, 2026 · N827SY · Boeing 7378F2 · Wing, Longeron/StringerSDR SCNA20260630272Pressure Deck · crackedTHREE CRACKS WERE FOUND ON THE RT WING CENTER SECTION REAR SPAR VERTICAL PRESSURE DECK WEB, BS 663.75, RBL 25 TO RBL45: BETWEEN RBL31.83 AND RBL 40.00 CRACK 1=1.1125IN LENGH, CRACK 2=1.060IN LENGTH, BETWEEN RBL 40.00 AND RBL 45.64 CRACK 3=3.0IN LENGTH, IN REFEMay 19, 2026 · N827SY · Boeing 7378F2 · Wing Main, Frame StructureSDR SCNA20260518204SGlowstrip · damagedPHOTOLUMINISCENTS STRIPS WERE FOUND DAMAGE (08 EAS). PHOTOLUMINISCENTS STRIPS 08 EAS. WERE REPLACED AND PN PL1100LH07 WAS VERIFIED PER B737-800 AIPC 33-51-05-88 ITEM 230.May 17, 2026 · N827SY · Boeing 7378F2 · Emergency EquipmentSDR SCNA20260518204Light · damagedPHOTOLUMINISCENTS STRIPS WERE FOUND DAMAGE (08 EAS) OPENMay 17, 2026 · N827SY · Boeing 7378F2 · Emergency LightingSDR SCNA20260616251Stringer Clip · crackedCRACK ON FRAME/STR CLIP ON STA 500H AND STGR 19RT AT FWD CARGO COMPARTMENT. CLIP FRAME/STGR ON STA 500H AND STR 19RT AT FWD CARGO COMPARTMENT WAS REPLACED IAW SRM 51-40-02-0G-0.May 6, 2026 · N827SY · Boeing 7378F2 · Fuselage Main, Attach FittingsSDR SCNA20260630271Pressure Deck · damagedREPAIR INSTALLED IN WING CENTER REAR SPAR VERTICAL PRESSURE DECK WEB BETWEEN LBL40 AND 45.64 REQUIRES REPLACEMENT. (LIFE LIMITED REPAIR PER AMM/ENG)May 4, 2026 · N827SY · Boeing 7378F2 · Fuselage Main, StructureSDR SCNA20260505185Light · inoperativeDURING OPERATIONAL CHECK OF THE EMERGENCY LIGHTS (AISLE 15 RH AND WING EMERG. LIGHT AFT RH), WERE FOUND INOPERATIVE. ROUBLESHOOTING WAS PERFORMED, BATTERY PACK (M1671) OF OVERWING EMERG LIGHT AFT RH AND EMERGENCY LIGHT LAMP (AISLE 15 RH) WERE REPLACED IAW FIMay 4, 2026 · N827SY · Boeing 7378F2 · Emergency LightingSDR SCNA20260616250Angle · wornWEAR ON ANGLE AT LOWER SURFACE OF INB MAIN FLAP APROX ITEF 75.97 AT LT & RT WINGS. ANGLES WERE REPLACED AT LOWER SURFACE OF INB MAIN FLAP APROX ITEF 75.97 AT LT & RT IAW SRM 51-40-02-0G-0.Apr 30, 2026 · N827SY · Boeing 7378F2 · Wing Miscellaneous StructureSDR SCNA20251226506Lens · deterioratedRIGHT FWD EMERGENCY EXIT DOOR ROW 15DEF LIGHT LENS DERIORATED.DECRATIVE PAINT CHIPPED. TOUCH UP PAINT LIGHT AT ROW 15 DEF IAW AMM 51-21-99.Dec 23, 2025 · N827SY · Boeing 7378F2 · Passenger Compartment LightingSDR SCNA20251226503Lens · deterioratedRIGHT FWD EMERG. EXIT DOOR LIGHT LENS DETERIATED IAW GMM/MTI MDDR #135854.Dec 22, 2025 · N827SY · Boeing 7378F2 · Emergency LightingSDR SCNA20251202457Trim Panel · damagedSHARP METAL TRIM NEAR 2L AFT LAV STICKING OUT. SECURED TRIM NEAR AFT LAV REF AMM 25-31-00. OK FOR SERVICE.Dec 1, 2025 · N827SY · Boeing 7378F2 · Passenger Compartment EquipmentSDR SCNA20251022400SCarpet · unsecureFORWARD ENTRY BASEBOARD CARPET IS PEELING OFF WALL, PLASTIC IS A TRIP HAZARD ( NON-ESSENTIAL EQUIPMENT AND FURNISHING (NEF) ) REMOVED AND REPLACED FORWARD ENTRY BASEBOARD CARPET AND KICKSTRIP PLASTIC REF CMM 25-26-18. THIS CLEARS MEL 25-10NOct 17, 2025 · N827SY · Boeing 7378F2 · Standard Practices/StructuresSDR SCNA20251022400Carpet · peelingFORWARD ENTRY BASEBOARD CARPET IS PEELING OFF WALL, PLASTIC IS A TRIP HAZARD. OPENOct 17, 2025 · N827SY · Boeing 7378F2 · Passenger Compartment EquipmentSDR SCNA2025091500375Seat Track · out of limitsCOPILOT AFT OUTBOARD SEAT TRACK OUT OF LIMITS. REMOVED AND REPLACED COPILOT AFT OUTBOARD SEAT TRACK IAW B737 AMM 25-11-11-400-801Sep 10, 2025 · N827SY · Boeing 7378F2 · Fuselage, Seat/Cargo Attach FittingsSDR SCNA20250915375Window Frame · crackedCRACK NOTED R1 WINDOW FRAME UPPER OUTBOARD CORNER. REPAIR OF R/H #1 WINDOW FRAME WAS ACCOMPLISHED ON EA TASK CARD 737-53-1336-01-G3CFG1&2-R. 89773U 09/11/2025Sep 7, 2025 · N827SY · Boeing 7378F2 · Fuselage Main, StructureSDR SCNA20250904358Slide · out of positionCREW REPORTS L1 DOOR SLIDE FLAP HANGING LOW. RE-POSITIONED L1 DOOR SLIDE FLAP AND INSPECTED SLIDE LATCH REF AMM 25-66-01Sep 4, 2025 · N827SY · Boeing 7378F2 · Escape SlideSDR SCNA20250731288Retainer · out of adjustL1 GIRT BAR VERY LOOSE. ADJUSTED GIRT BAR RETENTION CLIPS AT L-1 POS. PER AMM 25-66-00Jul 31, 2025 · N827SY · Boeing 7378F2 · Emergency EquipmentSDR SCNA20250616211Battery Pack · inoperativeFOUND EMERGENCY EXIT SIGNS AND LEFT ESCAPE SLIDE LIGHT IN FWD GALLEY INOP. - REMOVED AND REPLACED BATTERY PACK AT M1675 POWER SUPPLY. EMERGENCY LIGHS OPS CHECK GOOD.REF AMM 33-51-06.Jun 14, 2025 · N827SY · Boeing 7378F2 · Emergency LightingSDR SCNA20250505155Strap · corrodedFLOOR STRAP AT BS 1019 RBL 18 WL 208 HAS CORROSION - RESOLUTION: FOUND NO ALLOWABLE DAMAGE IN SRM, REPAIRABLE BY REPLACEMENT PER SRM 51-10-02-OG-0, STEP 9(C), REMOVED AND INSTALLED NEW FLOOR STRAP AT B.S. 1019, RBL18, WL208 PER SRM 51-40-02-OG-0, DWG 147A5700Apr 23, 2025 · N827SY · Boeing 7378F2 · Fuselage Main, StructureSDR SCNA20250505158Stringer · damagedWO 94518, TASK CARD ENG-53SCA-11445: N827SY - STRINGER 28R REPAIR BETWEEN BS 500B AND BS 500H - INSTALL - C/W FAS# 9230Apr 22, 2025 · N827SY · Boeing 7378F2 · Fuselage Main, StructureSDR SCNA20250505154Frame · crackedSTA 312 FRAME HAS A CRACK ON THE EDGE BETWEEN STR 5-6 LH - STA 312 FRAME REPAIRED IAW SRM 53-10-07-2R-1 BETWEEN STA 5-6 LHApr 17, 2025 · N827SY · Boeing 7378F2 · Fuselage Main, FrameSDR SCNA202505052153Frame · crackedSTA 312 FRAME HAS A CRACK ON THE EDGE BETWEEN STR 5-6 LH - STA 312 FRAME REPAIRED IAW SRM 53-10-07-2R-1 BETWEEN STA 5-6 LH.Apr 17, 2025 · N827SY · Boeing 7378F2 · Fuselage Main, StructureSDR SCNA20250312073Light · inoperativeWORK ORDER 93797 N/R-00002: WHEN CHECKING EMERG LIGHTS PER TASK CARD #330100000, EMERG LINGTS REMAINED ON FOR 10 MIN OR LESS AT FWD ENTRY DOOR, AFT LH ENTRY DOOR , AFT GALLEY OVERHEAD LIGHT . - - RESOLUTION: (IN PROGRESS)Mar 11, 2025 · N827SY · Boeing 7378F2 · Emergency LightingSDR SCNA20250312072Light · inoperativeWORK ORDER 93797 N/R-00001: PER TASK CARD #330100000, EMERG LIGHTS DID NOT COME ON AT ROW 11 ABC, 18 ABC, 24ABC, 26 ABC, AND DEF ROW 4. - - RESOLUTION: (IN PROGRESS)Mar 11, 2025 · N827SY · Boeing 7378F2 · Emergency LightingSDR SCNA20250505157Stringer · corrodedSECONDARY FINDING FOUND STRINGER 28R STR. CLIP AT BS 500D PN 143A1010-15 TO BE CORODED. - REMOVED AND REPLACED STRINGER CLIP DN# 143A1010-15 AT BS500D STR28R, LOCATED AND DRILLED NEW CLIP PER B-737 SRM 51-40-05-OG-0 AND DWG# 143A1225 REV B. STRINGER CLIP WILLMay 15, 2024 · N827SY · Boeing 7378F2 · Fuselage Main, Longeron/StringerSDR SCNA20250505156Strap · corrodedSECONDARY FINDING: WHILE REMOVING STRAP AT STA 800-847 WL 156 RH STR 25 FOUND CORROSIO N ON BOTTOM SIDE - REMOVED AND INSTALLED NEW STRAP AT STA 800-847 WL 156 RH PER SRM 51-40-02-OG-0 DWG 146A8180 ID: 0034 REV: -, DWG 146A8340, ID 0019, REV: -May 7, 2024 · N827SY · Boeing 7378F2 · Fuselage Main, StructureSDR SCNA20250425132Stringer · corrodedEMP# 55792 - FORWARD CARGO BAY STR-28R CORRODED BS 500E+7, RBL 7, WL 148 - RESOLUTION: REPAIRED STR.-28 R BS 500E IAW ER 24-01631 EMP# 56690 06/01/2024, INSP# 34 06/02/2024Apr 27, 2024 · N827SY · Boeing 7378 · Fuselage Main, Longeron/StringerSDR SCNA20240610252Frame · crackedSTA 312 FRAME HAS A CRACK ON THE EDGE BETWEEN STR 5-6LH. REPAIRED IAW 53-10-07-2R-1.Apr 15, 2024 · N827SY · Boeing 7378F2 · Fuselage Main, FrameSDR SCNA20240305057Window · crackedL1 WINDOW OUTER PANE CRACKED DURING CLIMB THROUGH FL280. REMOVED AND REPLACED L1 WINDOW IAW AMM 56-11-11. PERFORMED WINDOW HEAT SYSTEM OPERATIONAL TEST IAW AMM 30-41-00-710-801. OK FOR SERVICE.Feb 27, 2024 · N827SY · Boeing 7378F2 · Flight Compartment WindowsSDR SCNA20240116009Flashlight · unknownDEFECT W/O 84354 NRC00001: - - CREW REPORTS FORWRD FA FLASHLIGHT NOT FLASHING - - RESOLUTION: REMOVED AND REPLACED FWD INBOARD FA FLASH BATTERY IAW AMM 25-64-00-900-806. OPS CHECK GOOD. THIS CLEARS MEL 25-12-1 MDDR#122104Jan 10, 2024 · N827SY · Boeing 7378F2 · Emergency EquipmentSDR SCNA20231024234SUnknown · unknownSUPPLEMENTAL DEFECT 761420 - - - RESOLUTION - REMOVED & REPLACED CTR TANK FUELING VALVE IAW AMM 28-21-51 OPS CHECK GOOD NO LEAK AND NO FUEL MIGRATION NOTED A/C OK FOR SERVICEOct 14, 2023 · N827SY · Boeing 7378F2 · Aircraft Fuel Distribution SystemSDR SCNA20231017234Unknown · unknownDEFECT 761420: - - - SHORTLY AFTER LEVEL OFF AT 40K, RIGHT CENTER LOW PPRESSURE LIGHT ILLUMINATED WITH APPROX 4.5 IN CENTER TANK. LH TANK SHOWED FULL AT 8.66, RH TANK SHOWED 7.92. WHEN POWER DECREASED FOR DESCENT, CENTER QUANTITY INCREASED ANF RH QUANTITY CONTOct 14, 2023 · N827SY · Boeing 7378F2 · Aircraft Fuel Distribution SystemSDR SCNA20230828215Unknown · unknownDEFECT WO 81148: RH FWD EMERGENCY EXIT DOOR SIDEWALL LIGHT INOP. - - - RESOLUTION: RELAMPED RH FWD EMER EXIT SIDEWALL LIGHT. REF AMM 33-21-00. DID NOT FIX. LAMP STILL INOP.Aug 15, 2023 · N827SY · Boeing 7378F2 · Emergency LightingSDR SCNA20230828214Unknown · unknownDEFECT 81148: EMERGENCY LIGHT INOP ROW 4DEF - - - RESOLUTION: RELAMPED ROW 4D EMERGENCY EXIT AREA LIGHT IAW AMM 33-51-03. OPS CHECK GOOD.Aug 15, 2023 · N827SY · Boeing 7378F2 · Emergency LightingSDR SCNA20230828213Unknown · unknownDEFECT W/O 81148: EMERGENCY EXIT LIGHTS INOP AT R/H OVERWING EXITS. - - - RESOLUTION: REPLACED EMERGENCY LIGHT BATTERY PACK FWD OF RH EMER EXIT WITH A SERVICABLE UNIT. REF AMM 33-51-06. OPS CHECK GOOD.Aug 15, 2023 · N827SY · Boeing 7378F2 · Emergency LightingSDR SCNA20210505018Plate · crackedRIGHT HAND WING INBOARD WIGGLE PLATE UNDER WING PANEL 651GB CRACKED. REPAIRED RH WING IB WIGGLE PLATE UNDER WING PANEL 651GB PER EA 57-0063.May 1, 2021 · N827SY · Boeing 7378F2 · Wing Main, Frame StructureSDR SCNA20210505019Floor Panel · corrodedPASSENGER CABIN FLOOR FWD WET AREA 221BF IS DAMAGE. REPAIRED DAMAGE ON PASSENGER CABIN FLOOR FWD WET AREA 221BF IAW B737 SRM 53-00-50-2R-6.Apr 28, 2021 · N827SY · Boeing 7378F2 · Fuselage Floor PanelSDR SCNA201809143107Flap System · malfunctionedENCOUNTERED A FLAP DISAGREEMENT. FLAP HANDLE WAS IN THE 30 DEGREE DETENT AND FLAPS INDICATED 25 ON FLAP INDICATOR. ACCOMPLISHED NNC. LAX FIRE DEPARTMENT REPORTED SMOKE COMING FROM NR 1 BRAKE AREA. PERFORMED FSEU BITE. NO FAULTS FOUND. OPERATED FLAPS 0-40, OPS Sep 13, 2018 · N827SY · Boeing 737800* · Trailing Edge Flap Control System
Back to N827SY