N827UA
Service difficulty reports · 104
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N827UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N827UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2017021300355Filter · dirtyACRID SMELL IN COCKPIT THAT EVENTUALLY WENT THROUGHOUT CABIN. REMOVED AND REPLACED RECIRCULATION FILTERS REF AMM 21-21-41 AS REQUESTED BY TOMC. OPERATED APU AND APU BLEED SYS. ALSO OPERATED BOTH ENGINES AND ENG BLEED SYS. NO ODORS NOTED IN FLIGHT DECK, CABIN OSDR CALA2016021695109Door Sill · corrodedMAJOR REPAIR & SDR. R2 DOOR CORROSION 21" & 61" FWD OF FRAME 68. R & R R2 DOOR SILL DUE TO NO REWORK ALLOWED IN THE AREA IAW NOTE 6. IAW SRM 53-41-14 INSTALLED SPLICE ANGLES AT UPPER INBD & OTBD SIDES OF FRAME 66.SDR CALA2015102894728Acoustic Liner · damagedBIRD STRIKE ON TAKEOFF ROLL IN NR 2 ENG, STALL ECAM ALONG WITH AUDIBLE STALL. ABORTED TAKEOFF AT 90 KNOTS. ENG 2 REPLACED FOR ACOUSTIC LINER DAMAGE, CF247. ESN V10017 INSTALLED & NR 4 BEARING SCAVENGE LINE REPLACED.SDR CALA2015083194256Unknown · vibrationAIRFRAME VIBRATION FELT ON CLIMB OUT FL 240 - 290, AIRSPEED 300 - 320. VIBRATION REPORTING CHECKLIST COMPLETED BY PILOT & ENTERED INTO AMIS DISPLAY 49859. COMPLETED SERVICE TIP MT 53-005 & TSM 05-50-00-810-801.SDR CALA2013121693717Tape · peelingIAW CF949 TAPE IS PEELING BADLY FROM REPAIR IN NR 2 ENG BYPASS SECTION. RESTORED TEMPORARY REPAIR, OK TO CONTINUE. TAPE PEELING FROM NR 2 ENG C DUCT PREVIOUS DEFERRED.SDR CALA2013120993553Exhaust Duct · damagedAFT BURNER SECTION OF THE 2 ENG SEPARATING. IAW MT 78-005 DAMAGE IS IN C DUCT NOT HOT SECTION AT 3 O'CLOCK AS VIEWED FROM REAR IAW TEP 2 C 2. REMOVED DAMAGE 15 X 1 & TAPED, OK TO CONTINUE.SDR CALA2013120393399Ignition Lead · faultyAPU AUTO SHUT DOWN WITH FAULT LIGHT. R & R IGNITION UNIT & LEADS IAW AMM 49-41-38 & 49-41-31, OPERATIONS CHECKED GOOD.SDR CALA2013112593226Screw · looseCAPTAIN`S TRIGGER SWITCH ON CONTROL STICK IS LOOSE. TIGHTENED CAPTAIN`S TRIGGER SWITCH MOUNT SCREW.SDR CALA2013111292850Antenna · defectiveVHF 1 RADIO INOPERATIVE. REPLACED VHF 1 ANTENNAE IAW MM. PERFORMED OPERATIONAL CHECK.SDR CALA2013102992468Transceiver · faultyVHF 1 RECEIVE BUT NO TRANSMIT. R & R NR 1 VHF TRANSCEIVER IAW AMM 23-12-33. OPERATIONS CHECKED NORMAL. OK TO CONTINUESDR CALA2013100391711Battery Pack · failedRT OVERWING EMERGENCY BATTERY PACK FAILED "BAT FAULT" BY-07121. REPLACED BATTERY & PERFORMED NR 2 SERVICE EMERGENCY LIGHT CHECKED NO FAULTS.SDR CALA2013092391321Arm · brokenAUDIO VISUAL DOOR ABOVE 1B HAS THE SHOCK ABSORBER DOOR ARM BROKEN OUT OF THE CABINET WALL. RESECURED AUDIO VISUAL DOOR ABOVE 1B SHOCK ABSORBER IN CABINET.SDR CALA2013090490966Battery Pack · faultyRIGHT OVERWING EMERGENCY BATTERY PACK FAILED "BAT FAULT". REPLACED BATTERY & PERFORM NR 2 SERVICE EMERGENCY LIGHT CHECK=NO FAULTS.SDR CALA2013091191209Fence · damagedFOUND WING TIP FENCE DAMAGED BEYOND SRM ALLOWABLE DAMAGE LIMITS. REPLACED LT WING TIP FENCE IAW TASK 57-31-22-400-001-A.SDR UALA2013062604473Bearing · out of toleranceLEFT MLG FIXED FAIRING LOWER FWD AND AFT ROD END ATTACH POINTS TO GEAR LEG HAS EXCESSIVE PLAY. FOUND WEAR AT LANDING GEAR SPHERICAL BEARING. RESTAKED BEARING. AFT SIDE OF GEAR. STILL SOME SMALL AMOUNT OF MOVEMENT IN FIXED FAIRING. REPLACED UPPER AND LOWER LSDR UALA2013022101050Bottle · low pressureDOOR 2R SLIDE PRESSURE APPEARS LOW. SERVICED R2 DOOR BOTTLE EMERGENCY ASSIST IAW MM.SDR UALA2013022001019Adc · malfunctionedAFTER T/O CAPTAIN EXPERIENCED LOSS OF AIRSPEED, ALT AND OTHER AIR DATA INDICATIONS. INDICATIONS RETURNED TO NORMAL SEVERAL MINUTES AFTER TAKEOFF. ALL INDICATIONS NORMAL AT THIS TIME. SAMC TEXT: FAULTY AIR DATA INDICATIONS RETURNED. CAPT SELECTED ALT ADC ANSDR UALA2013022001041Unknown · inoperativeLAV SYSTEM INOP, FLIGHT DIVERTED.SDR UALA2013021200847Lens · damagedL2 DOOR EXIT LIGHT LENS DAMAGED. REPLACED LIGHT LENS.SDR UALA2013010700106Oxygen Bottle · low pressureO2 BOTTLE HAS LOW PRESSURE. REPLACED O2 BOTTLE.SDR UALA2013010300040Fastener · missingNR 2 ENGINE PLYON, PANEL 482AR, MISSING ONE EACH FASTENER. REPLACED MISSING FASTENER IN PANEL 482AR.SDR UALA2012060803123Liner · crackedATTRITION LINER CRACKED 3 INCHES AND DELAMINATED AT 6:00 POSITION. NR 2 ENGINE ATTRITION LINER DAMAGE MEASURED FROM 5:30 TO 6:00 ABOUT 7.5 INCH BY 6 INCHES= 45 SQ INCHES FOR ABOUT 22 PERCENT DAMAGE. MORE DAMAGE FROM 6:00 TO 7:00 ABOUT 5.5 INCH BY 13 INCH, 5 SDR UALA2011031001161Door Frame · damagedRIGHT OVERWING EMERGENCY SLIDE BLOW OUT DOOR FRAME SPLIT AND BENT. DAMAGE APPROX 9 INCHES LONG LOWER AFT SECTION OF DOOR FRAME. REPLACED RIGHT OVERWING SLIDE PER AMM. ACCOMPLISHED FINAL INSTALLATION PER MM AND METHOD 4 OF THE RII LIST.SDR UALA2011030201024Idg · leakingNR 1 ENG OIL LEAKING OUT BOTTOM OF ENGINE. ENG OIL LEAK DUE TO NR 1 ENG IDG FAILURE. IDG HAS BEEN REPLACED. OPS NORMAL.SDR UALA2010082703182Light · missingDURING INSTALLATION OF DOOR 2L ESCAPE SLIDE, IAW JIC 4R2592039, SEQ. 468, THE SLIDE ARMED LIGHT FAILED TO WORK. FOUND LIGHTS IN CAVITY NOT INSTALLED: INSTALLED IN RECEPTACLES AND OP. CKD. OK.SDR UALA2010082703181Bolt · shearedAFT PIT FRAME 46, LT CABIN FOR EXPANSION JOINT BOLT SHEARED. BOLT REPLACED AND AREA INSPECTED IAW NTM.SDR UALA2009122103953Panel · out of adjustLT OVERWING DOOR ILLUM, RTFL. ADJUSTED LT WING EXIT DOOR PANEL. VERIFIED WITH PANEL OFF SLIDE ARMED LIGHT WORKED OK. REINSTALLED PANEL ALL INDICATIONS NORMAL AT DOOR AND IN COCKPIT.SDR UALA2009113003687Actuator · faultySEATS 10DEF FAIL OXYGEN MASK DROP TEST. PANEL DOES NOT OPEN. SEATS 10DEF ARE CONSIDERED INOP. REPLACED ACTUATOR ASSY PCN 649-2759, OPS CHECK PER AMM35-23-00-501, OPS GOOD.SDR UALA2009112003625Line · leakingYELLOW HYD LOW PRESS, FLIGHT DIVERTED. ON WALK AROUND FOUND HYD FLUID LEAKING FROM NR 2 ENG UPPER PYLON. FOUND 2 EA HYD LINES LEAKING INSIDE ACCESS PANEL 425BR. WRAPPED SAFETY WIRE TO SHOW LINES. REMOVED ENG PRECOOLER AND 2EA FIRE X BOTTLES AND CONTINUED RESDR UALA2009062201748Bottle · low pressureCREW REPORTED PORTABLE O2 BOTTLE FWD CABIN FWD BOTTLE PRESSURE GAUGE INDICATING INTO THE RED BAND. SERVICED O2 BOTTLE. PRESSURE GAUGE IS READING INTO THE FULL BAND.SDR 2008UALA05530Hydraulic System · lowLANDED UNDER AMBER ALERT DUE TO LOSS OF GREEN HYDRAULIC SYSTEM. AIRCRAFT TOWED TO GATE.SDR 2008UALA05501Hydraulic System · overheatedGREEN HYD SYSTEM OVERHEAT AFTER TAKEOFF. FLIGHT DIVERTED.SDR UALA2008111304043Valve · failedVENT SKIN VALVE FAULT. RTFL. ALTHOUGH NO LONGER CHRONIC, THIS APPEARS TO BE AN ISOLATED EVENT RELATED TO THE VALVE FAILURE.SDR 2008UALA04043Outflow Valve · faultedVENT SKIN VALVE FAULT. RTFL.SDR 2008UALA03633Battery Pack · faultyWHILE ACCOMPLISHING EMERGENCY LIGHT TEST "BATTERY EPSU RIGHT" DISPLAYED. *S/D* EPSU FAILURE. REPLACED EPSU.SDR 2008UALA02771Oxygen System · low pressureO2 LOW READS 1370.SDR 2008UALA01622Proximity Switch · out of adjustAFTER TAKEOFF HAD L OVERWING DOOR ECAM FOR 20 SEC WENT AWAY. PRESSURE FINE BUT FLIGHT ATTENDANT SAYS IT HAS A WIND. CAUSE, PROX SWITCH OUT OF ADJUSTMENT AND LANYARD STUCK IN DOOR MECHANISM. ADJUSTED PROX SENSOR AND REPLACED PINCHED LANYARD.SDR 2007UALA05344Epsu · failedEMERGENCY LIGHTS ON WITH SWITCH ARMED. EPSU FAILURE. REPLACED EPSU 13WL. ALL LIGHTS NORMAL.SDR 2007UALA05207Wire · chafedAFT PAX CABIN EMERGENCY LIGHTS ILLUMINATE AFTER ENGINE START. NUMEROUS WIRES FOR EPSU SYSTEM FOUND CHAFED AND OPEN. NO STRANDS BROKEN - INSULATION WORN TO BARE WIRE. UNKNOWN ROOT CAUSE. REPAIRED ALL WIRES FOUND DAMAGED, SYSTEM FUNCTIONS NORMALLY DURING TESSDR 2007UALA04610Oxygen Mask · misinstalledFIRST OFFICER'S O2 MASK LEAKING. FOUND CREW O2 MASK (FO) WAS NOT PROPERLY STOWED. RESTOWED FO MASK- NO LEAKING- SERVICED CREW O2 SYSTEM.SDR 2007UALA04356Warning Message · illuminatedELAC 1 PITCH FAULT DISPLAYED ON UPPER ECAM SCREEN. FOUND ELAC1 COMPUTER FAULT. REPLACED ELAC1 COMPUTER- OPS CHECK OK-NO PEPEATS.SDR 2007UALA04156Power Supply · failedEMERGENCY LIGHT SYSTEM TEST FAILED ON PTP PANEL, DISPLAYS EPSU FWD L. FOUND EPSU (FWD) IS FAULTY. REPLACED EPSU. NO REPEATS SINCE ORIGINAL.SDR 2007UALA01877Unknown · warning lightRTFL DUE TO FWD CARGO DOOR ECAM MESSAGE.SDR 2007UALA01115Hydraulic System · dischargedFLIGHT DIVERTED DUE TO A TOTAL LOSS OF THE GREEN SYSTEM HYDRAULICS. [SUP 06-06-07] FOUND A SPLIT HYDRAULIC LINE IN THE NR 1 ENGINE PYLON. DAMAGE WAS DUE TO EXCESS WEAR IN THE CLAMP AREA. REPLACED DAMAGED HYDRAULIC LINE. REPLACED NR 1 ENGINE DRIVEN PUMP AND CSDR 2007UALA00850Warning Message · false activationRTFL DUE TO FWD CARGO DOOR ECAM MESSAGE. *S/D* PERFORMED VISUAL CHECK OF FWD CARGO DOOR AND PROXIMITY SENSOR AND DID NOT FIND ANY DEFECTS. CAUSE UNKNOWN AT THIS TIME.SDR 2006UALA01887Battery · failedTHE EPSU BATTERY AFT L- MESSAGE SHOWED AFTER THE EMERGENCY LIGHT TEST. REPLACED BATTERY AND TESTED OK.SDR 2005UALA00929Lever · failedUNABLE TO RETRACT LANDING GEAR. ON TAKE OFF LANDING GEAR HANDLE WOULDN`T MOVE, GEAR STAYED DOWN. LANDING WT-140.8+SINK RATE-100FPM. REPLACED LANDING GEAR LEVER PER MM- 32-31-11, TESTS GOOD.SDR 2004UALA00557Oxygen System · dischargedFLIGHT CREW OXYGEN SYSTEM REPORTED AT 50 PSI. FLIGHT DIVERTED. CREW O2 MASK SET TO 100% AND IMPROPERLY STOWED. SERVICED TO FULL. OPERATIONS CHECK NORMAL.SDR 2004UALA00086Warning Light · illuminatedRETURN TO FIELD DUE TO ECAM NR 2 FUEL CONTROL FAULT. DEBRIS FLOWING THROUGH FMU CAUSED TORQUEMOTOR FAULT. THE DEBRIS WAS SUBSEQUENTLY FLUSHED OUT. THIS IS AN ISOLATED INCIDENT AND ENGINEEING WILL CONTINUE TO MONITOR THE FMU.SDR 2003UALA00903Warning Light · illuminatedEMERGENCY LIGHTS SYSTEM TEST FAILS WITH MESSAGE EPSU INT LOAD EMERGENCY L DISPLAYED. RESET SYSTEM C-B'S AND EMERGENCY LIGHTS PER MM 33-51-00. TESTS NORMAL.