N828AW
Service difficulty reports · 294
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N828AW' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N828AW' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR USAA2013101400014Seat Track · corroded2S CHECK, CORROSION FOUND ON SEAT TRACK BETWEEN FRAMES 36 TO41, S23R, -Y1292. REPLACED SEAT TRACK IAW SRM 51-72-11 & DWG D53370500.SDR USAA2013101400013Seat Track · corroded2S CHECK, CORROSION FOUND ON SEAT TRACK AT FRAME 16, Y765. REPLACED SEAT TRACK IAW SRM 51-72-11 & DWG D53112812.SDR USAA2013100800013Seat Track · corroded2S CHECK, CORROSION ON SEAT TRACK BETWEEN FR64 TO FR66, -Y765. REPLACED SEAT TRACK IAW SRM 51-72-11 & DWG D53472816.SDR USAA2013101600006Floor Panel · delaminatedDURING 2S CHECK, DELAMINATION FOUND ON FLOOR PANEL 222CF BETWEEN FRAMES 12 - 16, -Y1640 &-Y254. REPLACED FLOOR PANEL IAW SRM 53-02-00.SDR USAA2013101600005Floor Panel · corrodedDURING 2S CHECK, CORROSION FOUND ON FLOOR PANEL 222FF BETWEEN FRAMES 16 - 20 & -Y1732 & -Y1292. REPLACED FLOOR PANEL IAW SRM 51-72-11.SDR USAA2013101400025Floor Panel · delaminated2S CHECK, DELAMINATION FOUND ON FLOOR PANEL 221LF BETWEEN FRAMES 12 TO 16 & -Y254 TO Y765. REPLACED FLOOR PANEL IAW SRM 53-12-00.SDR USAA2013101100006Floor Panel · delaminated2S CHECK, DELAMINATION ON FLOOR PANEL 221PF BETWEEN FRAMES 12 TO 16 & Y254 TO Y1292. REPLACED FLOOR PANEL IAW SRM 53-12-00 & IRM 9701, REV G.SDR USAA2013101800003Floor Panel · debondedDURING 2S CHECK - DEBONDING ON FLOOR PANEL 161BF BETWEEN FRAMES 29 TO 63 & BETWEEN Y765 & Y1042.1. REPLACED FLOOR PANEL IAW SRM 53-02-00, FIG 209 & IRM 9701, REV G.SDR USAA2013101600009Floor Panel · delaminatedDURING 2S CHECK, DELAMINATION ON FLOOR PANEL 261AG FRAMES 64 - 66 & -Y765 & Y765. REPLACED FLOOR PANEL IAW SRM 53-02-00, FIG 209 & IRM 9701, REV G.SDR USAA2013101600008Floor Panel · delaminatedDURING 2S CHECK, FOUND DELAMINATION ON FLOOR PANEL 261BG FRAME 64 - 66 & Y765 - Y1732. REPLACED FLOOR PANEL IAW SRM 53-02-00, TABLE 103 & IRM 9701, REV G.SDR USAA2013101600007Floor Panel · delaminatedDURING 2S CHECK, DELAMINATION ON FLOOR PANEL 261DF FRAMES 66 - 68 & BETWEEN Y1292 & -Y1292. REPLACED FLOOR PANEL IAW SRM 53-02-00.SDR USAA2013101100008Floor Panel · delaminated2S CHECK, DELAMINATION ON FLOOR PANEL 261DF BETWEEN FRAMES 68 TO 70 & -Y1732 TO Y1792. REPLACED FLOOR PANEL IAW SRM 53-02-00, PAR 8H, FIG 209 & IRM 9701, REV G.SDR USAA2013101100007Floor Panel · delaminated2S CHECK, DELAMINATION ON FLOOR PANEL 262BG BETWEEN FRAMES 64 TO 66 & -Y1732 TO Y765. REPLACED FLOOR PANEL IAW SRM 53-02-00 & IRM 9701, REV G.SDR USAA2013100800024Floor Panel · delaminated2S CHECK, DELAMINATION ON FLOOR PANEL 251LF. REPLACED FLOOR PANEL IAW SRM 53-02-00, PAR 8.H., FIG 209.SDR USAA2013100800023Floor Panel · delaminated2S CHECK, DELAMINATION ON FLOOR PANEL 251GF. REPLACED FLOOR PANEL IAW SRM 53-02-00, PAR 8 H, FIG 209.SDR USAA2013100800022Floor Panel · delaminated2S CHECK, DELAMINATION ON FLOOR PANEL 252GF. REPLACED FLOOR PANEL IAW SRM 53-02-00, PAR 8 H, FIG. 209.SDR USAA2013100800021Floor Panel · delaminated2S CHECK, DELAMINATION ON FLOOR PANEL 152TG. REPLACED FLOOR PANEL IAW SRM 53-02-00, PAR 8 H, FIG 209.SDR USAA2013100800020Floor Panel · delaminated2S CHECK, DELAMINATION ON FLOOR PANEL 251UF. REPLACED FLOOR PANEL IAW SRM 53-02-00, PAR 8 H, FIG 209 & IRM 9701, REV G.SDR USAA2013100800019Floor Panel · delaminated2S CHECK, DELAMINATION ON FLOOR PANEL 151VG. REPLACED FLOOR PANEL IAW SRM 53-02-00, FIG 209 & IRM 9701, REV G.SDR USAA2013100800018Floor Panel · delaminated2S CHECK, DELAMINATION ON FLOOR PANEL 242FF. REPLACED FLOOR PANEL IAW SRM 53-02-00, PAR 8 H, FIG 209 & IRM 9701, REV G.SDR USAA2013100800017Floor Panel · delaminated2S CHECK, DELAMINATION ON FLOOR PANEL 231WG. REPLACED FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR USAA2013100800016Floor Panel · delaminated2S CHECK, DELAMINATION ON FLOOR PANEL 132EG. REPLACED FLOOR PANEL IAW SRM 53-02-00, FIG 209 & IRM 9701, REV G.SDR USAA2013100800015Floor Panel · delaminated2S CHECK, DELAMINATION ON FLOOR PANEL 231LF BETWEEN FRAMES 24 TO 28 & Y765 TO Y254. REPLACED FLOOR PANEL IAW SRM 53-02-00, PAR 8 H, FIG. 209 & IRM 9701, REV G.SDR USAA2013100800014Floor Panel · delaminated2S CHECK, DELAMINATION ON FLOOR PANEL 221DF BETWEEN FRAMES 16 TO 24 & Y254 TO -Y254. REPLACED FLOOR PANEL IAW SRM 53-12-00, PAR 5.F, FIG 206 & IRM 9701, REV G.SDR USAA2013090500004Wire Harness · brokenEMERGENCY LIGHT AT SEAT 4L INOPERATIVE, BROKEN WIRES. RETERMINATED WIRES IAW STANDARD MX PRACTICES REF ELECTRICAL SRM.SDR USAA2013070800022Strut · excess playLT FLAP INTERCONNECT STRUT HAS .018" RADILAL PLAY AT ACTUATING ROD BETWEEN INBD & OTBD FLAPS. REPLACED LT FLAP INTERCONNECT STRUT IAW AMM 27-51-44.SDR USAA2013070800021Strut · excess playRT FLAP INTERCONNECT STRUT HAS .018" RADIAL PLAY AT ACTUATING ROD BETWEEN INBD & OUTD FLAPS. REPLACED RT FLAP INTERCONNECT STRUT IAW AMM 27-51-44.SDR USAA2013060300018Door · excess playPILOT REPORT -AIRFRAME VIBRATION AT 300KTS- 310KTS AT 28,000 FT, DID NOT TRY FASTER SPEED BELOW 300 KTS NO VIB. NO VIB INDICATION FOR ENGINE & NO ECAM INDICATION OF FLIGHT CONTROL ANOMOLIES. FOUND LT NLG AFT DOOR WITH EXCESSIVE PLAY. REPLACED LT AFT DOOR IASDR USAA2013051700018Tank · fullCREW REPORTED A STRONG SMELL OF FUEL STARTING IN REAR OF CABIN THEN MOVING FORWARD AFTER LANDING. POSSIBLY DURING APU START. MAINTENANCE PERFORMED J/C 26L00021001 AND FOUND APU DRAIN TANK FULL. DRAINED TANK PER AMM 49-17-41-000-001-A. RAN BOTH PACKS FOR 30SDR USAA2013050700001Floor Panel · delaminatedFLOOR PANEL DELAMINATED AT AFT CARGO DOOR. REPLACED FLOOR PANEL IAW AMM 53-42-14-400-001-A.SDR USAA2013021500013Limiter · failedDURING CLIMB, CREW REPORTED AN ECAM CLASS 1 FAULT, AUTO FLT RUD TRV LIM SYS. CREW COMPLIED WITH ECAM INSTRUCTIONS. FAULT REMAINED. FLIGHT RETURNED TO FIELD AT PHX AND LANDED WITHOUT INCIDENT. NO EMERGENCY WAS DECLARED. MAINTENANCE REPLACED RTLU 4CC - REFESDR USAA2013010700020Power Supply · failedSY6 CHECK - EMERGENCY CEILING LIGHT ABOVE SEAT NR 1 & SEAT NR 7 INOP. REPLACED ESPU 10WL IAW A319 AMM 33-51-38. OPERATIONAL TEST OF EMERGENCY LIGHTS IAW A319 AMM 33-51-0-710-001, TEST OK.SDR USAA2013010800003Lens · missingSY6 CHECK - EMERGENCY EXIT LIGHT LENS MISSING AT LEFT & RIGHT EMERGENCY EXIT DOORS & FROM SEATS 1AC & 3AC. INSTALLED EMERGENCY EXIT LIGHT LENSES AT LEFT & RIGHT EMERGENCY EXIT DOORS IAW A319 AMM 33-51-13 INSTALLED EMERGENCY EXIT LIGHT LENSES ON SEATS 1AC + 3ASDR USAA2013010700023Power Supply · failedSY6 CHECK - FORWARD EMERGENCY POWER SUPPLY 10WL-FAULTY. REPLACED EMERGENCY POWER SUPPLY UNIT 10WL-FAULTY IAW A319 AMM 33-51-00-710-001.SDR USAA2013010700022Lens · missingSY6 CHECK - EMERGENCY EXIT LIGHT LENS MISSING AT LEFT & RIGHT EMERGENCY EXIT DOORS & FROM SEATS 1AC & 3AC. INSTALLED EMERGENCY EXIT LIGHT LENSES AT LEFT & RIGHT EMERGENCY EXIT DOORS IAW A319 AMM 33-51-13 INSTALLED EMERGENCY EXIT LIGHT LENSES ON SEATS 1AC + 3ASDR USAA2013010700021Power Supply · failedSY6 CHECK - EMERGENCY LIGHT AT SEATS 1CD AND 8CD INOP. REPLACED ESPU 10WL IAW A319 AMM 33-51-38. OPERATIONAL TEST OF EMERGENCY LIGHTS IAW A319 AMM 33-51-00-710-001 TEST OK.SDR USAA2013010700004Shear Plate · corrodedSY6 CHECK - LEVEL 2 GALVANIC CORROSION ON SHEAR PLATE BETWEEN FR69 TO FR70, S23R. REPLACED SHEAR PLATE BETWEEN FR69 TO FR70, S23R IAW A319 SRM 51-42-11.SDR USAA2013010200032Floorbeam · corrodedSY6 CHECK - LEVEL 2 GALVANIC CORROSION ON FLOORBEAM AT FR68, Y765. REPLACED FLOORBEAM AT FR68, Y765 IAW A319 SRM 51-74-00, 53-00-14 & 51-42-11.SDR USAA2013010200017Floorbeam · corrodedSY6 CHECK - LEVEL 2 GALVANIC CORROSION ON FLOORBEAM AT FR20, -Y1292. REPLACED FLOORBEAM AT FR20, -Y1292 IAW A319 SRM 51-74-00, 51-42-11 & 53-11-15.SDR USAA2013010200035Floorbeam · corrodedSY6 CHECK - LEVEL 2 GALVANIC CORROSION ON LONGITUDINAL BEAM AT FR68, -Y765. REPLACED LONGITUDINAL BEAM AT FR68, -Y765 IAW A319 SRM 53-00-14 FIG 102 & 51-42-11.SDR USAA2013010200034Floorbeam · corrodedSY6 CHECK - LEVEL 2 GALVANIC CORROSION ON LONGITUDINAL BEAM AT FR68, -Y1292. REPLACED LONGITUDINAL BEAM AT FR68, -Y1292 IAW A319 SRM 53-00-14 FIG 102 & 51-42-11.SDR USAA2013010200033Floorbeam · corrodedSY6 CHECK - LEVEL 2 GALVANIC CORROSION ON LONGITUDINAL BEAM BETWEEN FR67 TO FR68, -Y1292. REPLACED LONGITUDINAL BEAM BETWEEN FR67 TO FR68, -Y1292 IAW A319 SRM 53-00-14 FIG 102 & 51-42-11.SDR USAA2013010200030Shear Plate · corrodedSY6 CHECK - LEVEL 2 GALVANIC CORROSION ON SHEAR PLATE BETWEEN FR69 TO FR70, S23R. REPLACED SHEAR PLATE BETWEEN FR69 TO FR70, S23R IAW A319 SRM 53-00-14 FIG 102 & 51-42-11.SDR USAA2013010200031Dummy Rail · corrodedSY6 CHECK - LEVEL 2 GALVANIC CORROSION ON DUMMY RAIL AT FR16, Y503. REPLACED DUMMY RAIL AT FR16, Y503 IAW A319 SRM 51-42-11, 51-74-00 & 53-11-14.SDR USAA2012081000007Battery · dischargedEMERGENCY LIGHTS TEST FAILED. REMOVED AND REPLACED BATTERIES FOR 11WL & 12WL PER AMM 33-51-38. OPS CHECKED GOOD.SDR USAA2012051400013Light · brokenFORWARD BULKHEAD (BY 1L DOOR) EMERGENCY EXIT RED LENS IS MISSING. LIGHT BULB ALSO JAMMED DOWN INSIDE BULKHEAD WALL TOWARD THE FLOOR. REMOVED AND REPLACED EMERGENCY LIGHT ASSEMBLY AS REQUIRED. OPS CHECKED GOOD.SDR USAA2012030100004Floorbeam · corroded36 HOUR HOLD - CORROSION ON FLOORBEAM AT FR66, Y1292. REPLACED FLOORBEAM AT FR66, Y1292 IAW A319 SRM 51-42-11.SDR USAA2012022900018Floorbeam · corroded36 HOUR HOLD - CORROSION ON FLOORBEAM AT FR66, Y765. REPLACED FLOORBEAM AT FR66, Y765 IAW A319 SRM 51-42-11.SDR USAA2011120500019Battery · dischargedAFT FLASHLIGHT INOPERATIVE. REMOVED AND REPLACED FLASHLIGHT BATTERY.SDR USAA2011111400009Cylinder · low pressureDOOR EMERGENCY CYLINDER / ACCUMULATOR PRESSURE LOW R2 DOOR, APPROXIMATELY 1650 PSI. CHARGED TO PROPER LEVEL IAW AMM 52-10-00.
Back to N828AW