What was found
DURING 2S CHECK, CORROSION FOUND ON FLOOR PANEL 222FF BETWEEN FRAMES 16 - 20 & -Y1732 & -Y1292. REPLACED FLOOR PANEL IAW SRM 51-72-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING 2S CHECK, CORROSION FOUND ON FLOOR PANEL 222FF BETWEEN FRAMES 16 - 20 & -Y1732 & -Y1292. REPLACED FLOOR PANEL IAW SRM 51-72-11.