N829UA
Service difficulty reports · 154
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N829UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N829UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2013051403332Rub Strip · unsecureRUBBER STRIP HANGING DOWN AT ROW 22. SECURED STRIP AT ROW 22, OK FOR SERVICE.SDR UALA2013043003039Line · leakingHYDRAULIC LEAK FROM LEFT AILERON. FOUND HYDRAULIC SUPPLY LINE FOR INBD SERVO CONTROL, PIN HOLE LEAK AT ELBOW BULKHEAD FITTING. REPAIRED LINE.SDR UALA2013041502591Mechanism · out of adjustONE PAX O2 MASK DEPLOYED. BACK ROW. ADJUSTED LATCH MECHANISM & RESTOWED MASKS. ACCMP'D DROP CHECK REF MT 35-003, OPS CHECK NORMAL.SDR UALA2012111406576Handset · intermittentINTERPHONE IS INTERMITTENT AT LOCATION NOT SPECIFIED. CREW COMMENTS: PURSER INTERPHONE INOPERATIVE. REPLACED FWD FLT ATTENDANT HANDSET, SYSTEM CHECKS NORMAL AT THE GATE.SDR UALA2012110806429Wire · brokenNUMEROUS BROKEN WIRES AT 7506VP CONNECTOR.SDR UALA2012110506348Rivet · shearedON ARRIVAL FOUND RIGHT ENGINE PYLON BLOW PANEL POPPED OPEN. INF PANEL WAS POPPED OPEN AND REMOVED TO FIND OUT WHY LEFT PYLON PANEL WAS LOOSE AND WOULD NOT SECURE CLOSED. REPLACED SHEARED RIVETS AS NEEDED IAW AMM, NO DEFECTS NOTED WITHIN AREA.SDR UALA2012102906226Oxygen Mask · deployedOXYGEN MASKS AT ROW 12DEF DEPLOYED. SAMC TEXT: REPACK AND CF FOR DROP TEST WITHIN 3D PER AMM 35-23- 00-710-001. REPACKED AND INSP PER MT 35-002 CF FOR DROP TEST PER AMM 35-23-00-710-001.SDR UALA2012102506100Bearing · frozenHORZ STAB TO THS ACTUATOR RIGHT FITTING BEARING IS LOOSE IN FITTING, APPEARS BEARING IS FROZEN. REF IPC 55-16-36- 01 ITEMS 60, 80, 50, 40, 10, 20. SECURE RIGHT BUSHING ASSY, BEARING OK. REPLACED LEFT BEARING DUE TO BEING LOOSE.SDR UALA2012092405429Control Unit · faultyLAV AND CRG DET FAULT DISPLAYED ON UPPER ECAM SCREEN - SMOKE. RESET ONCE PER FM, CAME BACK ON AFTER 5 MINUTES. REPLACED SDCU PER MM26-17 -34, GROUND CHECK NORMAL.SDR UALA2012081304483Fitting · corrodedCORROSION AT 1 RT BOX FITTING AT FRAME 16 AND ZONE 520.SDR UALA2012051602805Circuit Breaker · malfunctionedELAC 1 PITCH FAULT DISPLAYED ON UPPER ECAM SCREEN. RESET ELAC1 CIRCUIT BREAKER, OP CHECKED REF MM 27-93-00-401. ALSO, RAN BOTH ENGINES AND NO FAULTS FOUND OR PRESENT ON ENGINE RUNS OR GROUND CHECKS, NO PRIOR HISTORY.SDR UALA2012051602804Power Supply · inoperativeEMERGENCY LIGHTING TEST FAILED. RESET L1 DOOR OVERHEAD EPSU, OP CHECKED GOOD REF MM 33-51-00.SDR UALA2012051002682Power Supply · no testEMERGENCY EXIT LIGHT TEST PER 3 SVC WILL NOT PASS. REPLACED BATTERY PACK AND POWER SUPPLY.SDR UALA2011121406863Bottle · low pressureCREW REPORT: DOOR 1L PRESSURE ASSIST LOW (1100PSI). SERVICED PER AMM.SDR UALA2011110105927Outflow Valve · failedOUTFLOW VALVE FAULTED, RTFL. REPLACED OUTFLOW VALVE 22HQ, OPS CHECKED GOOD. NO FAULTS.SDR UALA2011092005077Light · missingDOOR 1R LIGHT IS MISSING. REPLACED LIGHT ASSY.SDR UALA2011081704360Bottle · low pressureLOW EVACUATION SLIDE BOTTLE PRESSURE DOOR 1L. SERVICED DOOR ASSIST BOTTLE TO PROPER PRESSURE.SDR UALA2011080804164Servo Control · malfunctionedABRUPT PITCH DOWN 80 FEET BELOW CRZ. AP 1+2 COMPENSATED WITH SEMI ABRUPT PITCH UP. WENT 60 FEET ABOVE CRZ THEN DAMPENED OUT. DID TRBS IN AP 1+2 AND WITHOUT AP. ACFT PORPOISED AFTER THE REPLACEMENT OF RT YELLOW SYS ELEV SERVO VALVE 34CE2 PCN 644-9014. RT YESDR UALA2011080804163Actuator · leakingWITH PACKS ON, BURNING OIL SMELL IN CABIN. PER TAXI CREW, SMELL IS PRESENT WITH APU SUPPLYING AIR. OPENED APU COMPT DOORS AND FOUND A LARGE VOLUME OF HYDRAULIC FLUID IN THE APU INTAKE DUCT. FOUND EVIDENCE OF HYD FLUID LEAK INTO LOWER RUDDER COMPT APPEARS TOSDR UALA2011080504084Computer · faultyELAC 2 NEEDS REPLACEMENT. DUE TO RESETS, REPLACED ELAC 2 482-9572 PER AMM. REPLACED ELAC 2 PER MM AND TESTED OKAY.SDR UALA2011072903908Duct · obstructedCOCKPIT TEMP EXTREMELY HOT, 90 DEGREES MOST OF FLIGHT. CABIN TEMPS TOO COLD AND LOW FLOW FROM NR 2 PACK. REMOVED LARGE AMOUNT OF DEBRIS FROM COCKPIT CONDITIONED AIR DUCT SCREEN. DUCT WAS COMPLETELY CLOGGED. CLEANED SCREEN AND COCKPIT FLOW RETURNED TO NORMASDR UALA2011072803899Door · brokenCAPTAIN`S FWD OXYGEN MASK DOOR IS BROKEN. REPLACED O2 BOX PER AMM.SDR UALA2011041501837Power Supply · failedEMERGENCY LIGHT SYSTEM TEST FAILED, FAULT MESSAGE DISPLAYED IS EXT LOAD EMER RT. REPLACED THE RT EPSU AND POWER SUPPLY UNIT. ALSO REPLACED THE RT OVERWING AFT LIGHT ASSY. OPS CHECKED OKAY.SDR UALA2010112304328B-Nut · looseG SYS HYD ISSUE, RTFL. THE RT MLG DOOR BYPASS VLV (2518 GM), PORT 'C', 'B' NUT LOOSE. TIGHTENED AND ACCOMPLISHED LEAK CK. NO LEAKS NOTED. ACCOMPLISHED A RESET OF HANDLE AFTER A FREE FALL EXTENSION IAW MM.SDR UALA2010062302235Socket · unsecureLT OVERWING SLIDE INDICATION INOP. RESEATED SOCKET AT 2WNVC1 SLIDE ARMED IND LITE AT EMER EXIT DOOR. LT OVERWING DOOR. PINNED BOTH RT AND LT OVERWING ESCAPE SLIDE BOTTLES AND INOPED BOTH OVERWING DOORS FOR T/S. SECURED BOTH OVERWING ESCAPE SLIDE BOTTLES AND DSDR UALA2010060101899Target · bentNO SLIDE ARMED INDICATION WHEN ACCESS PANEL IS REMOVED AT LT OVER WING EXIT. NO LT SLIDE WORD ON LOWER ECAM WHEN ACCESS PANEL IS INSTALLED OR REMOVED. FOUND COVER FLAP FOR THE HATCH PROX TARGET TO BE BENT OUT OF POSITION. REPOSITION TARGET. EMERGENCY EXIT ECAMSDR UALA2010042901439Power Supply · failedDURING CIDS TEST OF EMERGENCY LIGHT SYS, MESSAGE EXT LOADS EMERGENCY R 33-51-38 CAME UP. REPLACED RT EMERGENCY SUPPLY UNIT. CIDS TEST OK.SDR UALA2010011100118Coffeemaker · malfunctionedSTRONG PLASTIC BURNING ODOR COMING FROM AFT GALLEY VENT ABOVE COFFEEMAKER. SMELL IS NOT DEICE. FOUND MALFUNCTION COFFEEMAKER. REPLACED BOTH AFT COFFEEMAKERS M41 AND M42.SDR UALA2009060101582Light · failedEMERGENCY LIGHTS TEST FAILED. FAULTS EPSU EXT LOAD EMER R. FOUND LIGHT ASSEMBLY 62WL FAILED. REPLACED EMERGENCY LIGHTS TEST NORMAL.SDR UALA2009032500885Oxygen Mask · malfunctionedOXYGEN MASKS FAIL TO DROP AT SEAT ROW 11RT DURING DROP TEST. ACP ON WU J9972L.SDR 2008UALA05771Line · looseY RSVR LO LVL DISPLAYED ON UPPER ECAM SCREEN - HYD. FOUND LOOSE LINE AT KEEL BEAM. SECURED HYD LINE AT KEEL BEAM, PUMP REPLACED FOR CAVITATION AND FILTERS DOWNLINE. SERVICED SYSTEM AND ALL LEAK CHECKS WERE GOOD.
SDR 2008UALA03293Computer · failedDUAL FMGC FAILURE. RTFL. *S/D* FMGC 2 FAILED-ARRINC INTERLOOP TEST FAILS. FMGC2 INOP UPON ARRIVAL. REPLACED FMGC2. PERFORMED AFS AND LAND TEST PER MM 22-96-00 AND MM 22-97-00. CHECKS GOOD.SDR 2008UALA02004Skin · damagedFOUND RIGHT OTBD FLAP HAS A HOLE AND A DENT AT THE MIDDLE AFT SECTION. REPAIRED DAMAGED AREA OF FLAP. (POTTED COMPOSITE REPAIR)SDR 2008UALA01495Unknown · odorMOMENTARY ELECTRICAL SMELL IN AFT CABIN, SMELL DISSIPATED. COULD NOT DUPLICATE. CHECKED INDIVIDUAL SEATS AND WALL DISCONNECT BOX 50MK6A, CHECKED BEHIND FLOOR SIDEWALL PANELS, POWERED PES, RAN PACKS, CHECKED GALLEY UNITS, COULD NOT DUPLICATE SMELL.SDR 2008UALA01422Oxygen Mask · inoperativeF/O O2 MASK INOP. REPLACED F/O O2 MASK.SDR 2008UALA01185Light · faultyEPSU EXT LOAD EMER R. FOUND INTERNAL SHORT WITHIIN SLIDE PACK. REPLACE RT OVERWING SLIDE AND PSU 12WL.SDR 2008UALA00661Lens · brokenDOOR 2 LEFT EXIT LT BROKEN. REPLACED LENS COVER.SDR 2007UALA05173Light · inoperativeEPSU EXT LOAD EMER R - FAULT FOUND ON 3 SVC EMERGENCY LIGHT TEST. OVERWING EMERGENCY WING LIGHTS INOP. REPLACED OVERWING EMERGENCY FLOOD LIGHTS.
SDR 2007UALA03504Guard · missingEMERGENCY LIGHT SW GUARD ON THE AFT F/A PANEL IS MISSING. REPLACED EMERGENCY SWITCH LIGHT AT AFT GALLEY.SDR 2007UALA03441Lamp · burned outRIGHT FWD OVERWING LIGHT INOPERATIVE. FOUND LAMP BURNED OUT. REPLACED LIGHT ASSY.SDR 2007UALA02760Hydraulic System · inoperativeFLIGHT DIVERTED DUE TO LOSS OF BLUE HYDRAULIC SYSTEM. LOSS OF HYDRAULIC FLUID DUE TO LEAK AT MOUNTING POINT FLANGE OF THE ELECTRIC HYD PUMP. REPLACED BLUE ELECTRIC HYDRAULIC PUMP, SERVICED SYSTEM.SDR 2007UALA02614Panel · damagedNR 1 ENGINE FWD PYLON CANTILEVER PANEL IS DAMAGED. REPAIRED FAIRING.SDR 2006UALA00886Light · no testEMERGENCY LIGHT TEST FAILS. REPLACED RIGHT EMERGENCY POWER SUPPLY AND BATTERY.SDR 2006UALA00700Light · no testCABIN EMERGENCY LIGHT TEST FAILED. FAULTED -R EMERGENCY UNIT. RELAMPED AND OPS CHECKS OK.SDR 2006UALA00585Sill · corrodedFOUND DOOR 2 RT SILL BEAM HAS CORROSION BEYOND LIMITS. INSTALLED REPAIR ANGLES WHERE CORROSION OCCURRED PER SRM 53-41-14. REINFORCEMENT OF A PSE.SDR 2005UALA00626Slide · lowDOOR 1L SLIDE PRESS JUST OUTSIDE GREEN ARC. SLIDES BEING REMOVED DUE TO LOW BOTTLE PRESSURE IS NOT TOTALLY AN UNCOMMON EVENT. THE OPERATING ENVIRONMENT OF SLIDES (VIBRATION, DOOR OPENING/CLOSING, CARTS IMPACTING DOORS, TEMPERATURE & PRESSURE CHANGES) ARESDR 2004UALA00549Light · will not testEMERGENCY LIGHT TEST FAILED AFTER SLIDE REPLACEMENT AT DOOR 2L. THE SLIDE SHOP TESTED THE SLIDE ASSEMBLY UPON RECEIPT AND THE SHOP VERIFIED THE UNIT TO HAVE FAILED THE LIGHT TEST. THE COMPLETE LAMP HARNESS WAS REPLACED AND THE 22 BLOWN LIGHTS WERE REPLACEDSDR 2004UALA00470Sensor · inoperativeCABIN EMERGENCY LIGHTS FAILED TO TEST. RESET CIDS SYSTEM AND NO SMOKING LIGHTS. ACCOMPLISHED OPERATIONAL TEST OF EMERGENCY LIGHTS PER MM 33-51-00-710-001, SYSTEM GROUND TESTED OK, NO FAULTS NOTED ON PTP.SDR 2004UALA00244Generator · failedFLIGHT DIVERTED DUE TO A LOST GENERATOR. NR 2 GENERATOR BUSS LOSS. NUMBER 2 GENERATOR FAULT LIGHT ILLUMINATED SUPPLEMENTAL DATA UPDATE PIN AND SOCKET ON PYLON FIREWALL CONNECTOR 400VC CORRODED AND BURNED. REPLACED HARNESS ASSEMBLIES.SDR 2002UALA01279Slide · faultyDURING NR 3 SERVICE CHECK OF EMERGENCY LIGHTING SYSTEM FOUND EPSU EXT LOAD AFT L FAULT. POWER SUPPLY SHOWS EXT LOAD FAULT. SUSPECT SLIDE LIGHTS BAD. BOTH SLIDES REPLACED.
Back to N829UA