N830AW
Service difficulty reports · 225
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N830AW' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N830AW' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA201609069006Battery · faultyAIRCRAFT WAS NOT GROUNDED: DURING OPS TEST OF EMERGENCY LIGHTS RECEIVED FAULT EPSU BATTERY FWD LT. REPLACED BATTERY FOR EMERGENCY POWER SUPPLY UNIT 10WL AND ACCOMPLISHED A SATISFACTORY OPS CHECK IAW AMM 33-51-38-0000/400-002.SDR AALA201605039007Box Beam · crackedAIRCRAFT IN BASE MX. RT SIDE BOX BEAM UPPER FLANGE HAS 2 HOLES WITH CRACK INDICATIONS AT FRAME 43 & -Y1622. REPAIRED BOX BEAM IAW EO 5315Y066.SDR AALA201605039006Box Beam · crackedAIRCRAFT IN BASE MX. LT SIDE BOX BEAM UPPER FLANGE HAS 2 HOLES WITH CRACK INDICATIONS AT FRAME 43 & +Y1622. REPAIRED BOX BEAM IAW EO 5315Y066.SDR AALA201604039005Connector · disconnectedAIRCRAFT WAS NOT GNDED. EMER PATH LIGHTS ON SEAT 23C INOPERATIVE. FOUND CONNECTOR UNDER SEAT ROW 23ABC DISCONNECTED, RE-CONNECTED & ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK IAW AMM 33-51-00-710-001-A.SDR AALA201603259002Battery · dischargedAIRCRAFT WAS NOT GNDED. AFT LT FLIGHT ATTENDANT JUMP SEAT FLASHLIGHT NOT FLASHING. REPLACED FLASHLIGHT BATTERY & ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK.SDR USAA2014080500007Power Supply · defectiveTHE OPERATIONS TEST OF EMER LIGHTS INOPERATIVE IAW WEEKLY CHECK. ACCOMPLISHED RESET OF EPSU 10WL IAW AMM 33-51-38. OPERATIONS CHECKED GOOD.SDR USAA2014062400001Lens · missingTHE FWD EMER LIGHT RED HOUSING LENS MISSING. INSTALLED FWD EMER LIGHT RED HOUSING LENS.SDR USAA2013102500010Skin · delaminated2S CHECK -DELAMINATION ON RT SIDE OF RUDDER APPROX 46" FROM TOP & 12.5" FROM THE T/E. REPAIRED RT SIDE OF RUDDER IAW EA 205805.SDR USAA2013110100004Floor Panel · delaminatedDURING 2S CHECK, FOUND DELAMINATION ON FLOOR PANEL 232FF BETWEEN FRAMES 20 TO 24, Z-500 & -Y1292 TO -Y1610. REPLACED FLOOR PANEL IAW IRM 9701, REV G.SDR USAA2013101500018Floor Panel · delaminated2S CHECK, DELAMINATION ON FLOOR PANEL 232DF BETWEEN FRAMES 54 TO 58 & Y254 TO Y765. REPLACED FLOOR PANEL 232DF IAW IRM 9701, REV G.SDR USAA2013101500017Floor Panel · delaminated2S CHECK, DELAMINATION ON FLOOR PANEL 232DF BETWEEN FRAMES 24 TO 28 & Y254 TO Y765. REPLACED FLOOR PANEL.SDR USAA2013101500016Floor Panel · delaminated2S CHECK, DELAMINATION ON FLOOR PANEL 232DF BETWEEN FRAMES 20 TO 24 & -Y254 TO -Y765. REPLACED FLOOR PANEL.SDR USAA2013101500015Floor Panel · delaminated2S CHECK, DELAMINATION ON FLOOR PANEL 232LF BETWEEN FRAMES 24 TO 28 & -Y254 TO -Y765. REPLACED FLOOR PANEL.SDR USAA2013101500014Floor Panel · delaminated2S CHECK, DELAMINATION ON FLOOR PANEL 232XG BETWEEN FRAMES 28 TO 35 & Y254 TO -Y254. REPLACED FLOOR PANEL.SDR USAA2013101500013Floor Panel · delaminated2S CHECK, DELAMINATION ON FLOOR PANEL 231MF BETWEEN FRAMES 24 TO 28 & Y765 TO Y1292. REPLACED FLOOR PANEL.SDR USAA2013110100003Floor Panel · delaminatedDURING 2S CHECK, FOUND DELAMINATION ON FLOOR PANEL 221DF BETWEEN FRAMES 16 TO 21, Z-500, Y765. REPLACED FLOOR PANEL IAW IRM 9701 REV G.SDR USAA2013110100002Floor Panel · delaminatedDURING 2S CHECK, FOUND DELAMINATION ON FLOOR PANEL 221EF BETWEEN FRAMES 16 TO 20, Z-500, -Y254. REPLACED FLOOR PANEL IAW IRM 9701, REVISION G.SDR USAA2013100700010Profile · cracked2S CHECK. LEFT OVERWING EXIT DOOR LOAD TRANSMITTING PROFILE CRACKED. R & R PROFILE IAW EO 5210Y228.SDR USAA2013100700009Profile · cracked2S CHECK, RIGHT OVERWING EXIT DOOR LOAD TRANSMITTING PROFILE CRACKED. R & R PROFILE IAW EO 5210Y228.SDR USAA2013101100002Sill · corroded2S CHECK, CORROSION ON SILL PLATE AT FRAME 66+6", Z-500, -Y1292. REPAIRED SILL PLATE IAW EA 205796.SDR USAA2013093000021Floorbeam · corroded2S CHECK, CORROSION ON FLOORBEAM AT FRAME 66+6", Z-500, Y765. REPLACED FLOORBEAM IAW SRM 51-72-11 & DWG D53472780.SDR USAA2013072600022Lens · unsecureCREW REPORTED THE PATH LIGHT ASSY AT 1C IS BROKEN. MX RESECURED LENS COVER AS REQUIRED.SDR USAA2013071700005Cover · missingSEAT 1C EMERGENCY FLOOR LIGHTING COVER MISSING. MX REPLACED MISSING EMERGENCY LIGHT LENS AT SEAT 1C.SDR USAA2013070100014Apu · faultyF/A REPORTED A CABIN ODOR/SMELL COMPLAINT. MX DETERMINED APU IS SOURCE. COMPLIED WITH ENVIRONMENTAL CONTROL SYS DECONTAMINATION JOB CARD 26L00021004.SDR USAA2013051300005Unknown · odorJUST BEFORE TOP OF DESCENT, FLIGHT ATTENDANT CALLED TO REPORT A BURNING ELECTRICAL SCENT IN AFT GALLEY. MAINTENANCE COMPLETED J/C 26L00021001. NO SOURCE OF ODOR FOUND. AS PRECAUTIONARY, REPLACED ALL THREE AFT GALLEY COFFEEMAKERS PER AMM 25-35-15. ALSO, CLESDR USAA2013040900009Lens · missingCREW REPORTS DOOR 2R EMERGENCY LIGHT COVER MISSING. MAINTENANCE INSTALLED MISSING LENS ON DOOR 2R EMERGENCY LIGHT. REFERENCE AMM 33-51-19.SDR USAA2013040300001Light · inoperativeCREW REPORTED THE EXIT LIGHT LOCATION SIGN AT MAIN AISLE AFT CABIN HAS NO LIGHTS ILLUMINATED - 14 OF 14 BULBS OUT. MAINTENANCE REPLACED EXIT LOCATOR LIGHT ASSEMBLY AT AFT CABIN AISLE LIGHT. OPS CHECK GOOD.SDR USAA2013022200003Battery · dischargedMAINTENANCE REPORTED THE AFT LEFT GALLEY EMERGENCY FLASHLIGHT INOP. MAINTENANCE REMOVED AND REPLACED BATTERY IN AFT LEFT GALLEY FLASHLIGHT. OPS NORMAL AT THIS TIME.SDR USAA2013022100008Skin · saturatedC11 CHECK - SEVERAL AREAS OF WATER INGRESS INDICATIONS ON UPPER & LOWER SURFACES OF LEFT ELEVATOR SKIN BETWEEN 4 INCHES TO 14.5 INCHES FROM TRAILING EDGE, BETWEEN 9 INCHES TO 51 INCHES FROM OUTBOARD END & BETWEEN 12 INCHES TO 95 INCHES FROM INBOARD END. REPAISDR USAA2013022100007Skin · saturatedC11 CHECK - SEVERAL AREAS OF WATER INGRESS INDICATIONS ON UPPER & LOWER SURFACES OF RIGHT ELEVATOR SKIN BETWEEN 3.5 INCHES TO 7 INCHES FROM TRAILING EDGE, BETWEEN 14 INCHES TO 109 INCHES FROM OUTBOARD END & BETWEEN 17 INCHES TO 66 INCHES FROM INBOARD END. REPSDR USAA2013022000020Floorbeam · corrodedC2 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM AT FR67+18 INCHES, Y1292. REPLACED FLOORBEAM AT FR67+18 INCHES, Y1292 IAW A319 SRM 51-42-11.SDR USAA2013022000018Shear Plate · corrodedC2 CHECK - LEVEL 2 EXFOLIATION CORROSION ON SHEAR PLATE BETWEEN FR69 TO FR70, Y1162. REPLACED SHEAR PLATE BETWEEN FR69 TO FR70, Y1162 IAW A319 SRM 51-42-11.SDR USAA2013022000019Floorbeam · corrodedC2 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM AT FR66+3 INCHES, Y1292. REPLACED FLOORBEAM AT FR66+3 INCHES, Y1292 IAW A319 SRM 51-42-11.SDR USAA2013022000016Floor Support · corrodedC2 CHECK - CORROSION ON FLOOR SUPPORT BEAM AT FR16, Y503.2. REPLACED FLOOR SUPPORT BEAM AT FR16, Y503.2 IAW A319 SRM 51-42-11.SDR USAA2013022000008Shear Plate · corrodedC11 CHECK - LEVEL 2 EXFOLIATION CORROSION ON SHEAR PLATE BETWEEN FR69 TO FR70, -Y1292. REPLACED SHEAR PLATE BETWEEN FR69 TO FR70, -Y1292 IAW A321 SRM 51-42-11.SDR USAA2013021900002Lens · crackedC11 CHECK - EXIT MARKERS EMERGENCY LIGHT COVERS AT LEFT & RIGHT OVERWING EXITS & R1 DOOR ARE CRACKED. REPLACED EXIT MARKERS EMERGENCY LIGHT COVERS AT LEFT & RIGHT OVERWING EXITS & R1 DOOR IAW A319 AMM 33-51-13-000-001-A & 33-51-13-400-001-A.SDR USAA2013021500015Floor Support · corrodedC11 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOOR SUPPORT FR67+18 INCHES, -Y1292. REPLACED FLOOR SUPPORT FR67+18 INCHES, -Y1292 IAW A319 SRM 51-42-11.SDR USAA2013021500014Floor Support · corrodedC11 CHECK - LEVEL 2 INTERGRANULAR CORROSION ON FLOOR SUPPORT BETWEEN FR66 TO FR70, -Y765. REPLACED FLOOR SUPPORT BETWEEN FR66 TO FR70, -Y765 IAW A319 SRM 51-42-11.SDR USAA2013022000017Web · corrodedC2 CHECK - LEVEL 2 EXFOLIATION CORROSION ON AFT RIGHT ENTRY DOOR WEB AT FR68, -Y1292. REPAIRED AFT RIGHT ENTRY DOOR WEB AT FR68, -Y1292 IAW A319 SRM 53-41-14 REPAIR PRINCIPAL 5.SDR USAA2013021800021Floor Panel · delaminatedC11 CHECK - DELAMINATION ON FLOOR PANEL 232FF AT FR18, -Y1292. REPAIRED FLOOR PANEL 232FF IAW A319 SRM 53-12-00.SDR USAA2013021500017Floor Support · corrodedC11 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOOR SUPPORT FR68, Y1292. REPLACED FLOOR SUPPORT FR68, Y1292 IAW A319 SRM 51-42-11.SDR USAA2013021500016Floor Panel · delaminatedC11 CHECK - DELAMINATION ON FLOOR PANEL 231CF BETWEEN FR18 TO FR24. REPAIRED FLOOR PANEL 231CF IAW A319 SRM 53-12-00.SDR USAA2012033000008Light · inoperativeL2 DOOR EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED EMERGENCY LIGHT AT L2 DOOR. OPS CHECKED GOOD.SDR USAA2011120200007Light · disconnectedEMERGENCY EXIT LIGHT ON LAST ROW INOPERATIVE. CONNECTED EXIT LIGHT ASSEMBLY. OPS CHECKED GOOD IAW AMM 33-51-00.SDR USAA2011092000016Unknown · odorFLIGHT ATTENDANT SMELLED SMOKE IN FORWARD GALLEY. CAPTAIN AND FIRST OFFICER TRIED TO IDENTIFY ODOR BUT COULD NOT IDENTIFY SOURCE OR TYPE OF SMOKE ODOR. NO SMOKE WAS OBSERVED. COFFEE MAKER IN FORWARD GALLEY AND BOTH OVENS APPEAR TO HAVE BEEN USED IN FLIGHT. SDR USAA2011021190699Megaphone · inoperativeFLT 209 - PHX - EMERGENCY EQUIPMENT - FORWARD MEGAPHONE WILL NOT TEST. MAINTENANCE REPLACED THE FORWARD MEGAPHONE ASSEMBLY.SDR USAA2010110892532Battery · dischargedFLT 622 - LAS - EE - FORWARD MEGAPHONE REQUIRES BATTERY REPLACEMENT. MAINTENANCE REPLACED FORWARD MEGAPHONE BATTERIES.SDR USAA2010092292058Battery · dischargedFLT 641 - MCI-PHX - EMERGENCY LIGHTS - FLASHLIGHT BY DOOR L2 DOES NOT HAVE RED FLASHING LIGHT. REMOVED AND REPLACED AFT EMERGENCY FLASHLIGHT BATTERY. OPERATIONAL CHECK WAS GOOD.SDR USAA2010012290162Apu · leakingFLT 363 - PHX - CABIN ODOR - OILY, DIRTY SOCK SMELL NOTICED FROM PACKS WITH APU ON, MOSTLY DURING CRUISE AND DESCENT. MAINTENANCE REMOVED AND REPLACED THE APU.SDR USAA2010011490102Power Supply · inoperativeFLT 152 - PDX - PHC - EMERGENCY LIGHTS, FORWARD EMERGENCY POWER SUPPLY UNIT (EPSU) FAILED TEST. REMOVED AND REPLACED EMERGENCY POWER SUPPLY UNIT (EPSU). OPERATIONAL CHECK WAS GOOD.