What was found
DURING 2S CHECK, FOUND DELAMINATION ON FLOOR PANEL 221EF BETWEEN FRAMES 16 TO 20, Z-500, -Y254. REPLACED FLOOR PANEL IAW IRM 9701, REVISION G.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING 2S CHECK, FOUND DELAMINATION ON FLOOR PANEL 221EF BETWEEN FRAMES 16 TO 20, Z-500, -Y254. REPLACED FLOOR PANEL IAW IRM 9701, REVISION G.