N833UA
Service difficulty reports · 65
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N833UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N833UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2025073107130Ballast · failedELECTRICAL BURNING ODOR IN THE VICINITY OF EXIT ROW, CONFIRMED ELECT BURNING ODOR THROUGHOUT CABIN. ALSO FOUND G3 AIR CHILLER CIRCUIT BREAKER TRIPPED WITH MALFUNCTION LIGHT ON. & CABIN LIGHTS MALFUNCTIONING WITH SEVERAL OUT & SEVERAL FLICKERING. ALSO AFT GALSDR CALA2025061605563Switch · out of positionEMER EXIT LTS IN CABIN ON DURING FLT. ALL SWITCHES IN CORRECT PO S. UPDATED MAA CODE FIX USING VENDOR MAA SCREEN PLEASE CONTACT TOMC BEFORE COMMENCING ANY WORK. UPDATED MAA CODE FIX USING VENDOR MAA SCREEN PLEASE CONTACT TOMC BEFORE COMMENCING ANY WORK. MAC MESDR CALA2024110601030Battery · no testCABIN EMERGENCY LIGHTING BATTERY CAPACITY OPERATIONAL CHECK {A3NB-33-3-6013} - AFT CABIN EMERGENCY LIGHTING BATTERY FAIL TEST REPLACED AFT EMERGENCY LIGHTING BATTERY. REF AMM 33-51-38. OPS CHECK GOODPARTS USED: 18-3351-3-0001,QTY :1SDR CALA2023121403641Fuel Cap · missingPDA 2 FUEL CAP FOUND MISSING ON ARRIVAL CAP, COUPLING R OFF 31-2825-9-0001 1162 ON 31-2825-9-0001 3060 CAP, COUPLING R OFF 31-2825-9-0001 1162 ON 0000 REPLACED FUEL CAP WITH SERVICEABLE CAP REF AMM 28-25-41 LEAK CHECK GOOD. PARTS USED: 31-2825-9-0001,QTY :1 ROSDR CALA2023081802555Beam · unknownYO VERTICAL BEAM AT FR 1 BULKHEAD WAS REPAIRED AT BQN, REPAIR IS AN INTERM (TEMPORARY) SOLUTION. ACCOMPLISH A PERMANENT PER PART 3 OF THE LATEST REVISION OF EC/RA 5311-03051 ON OR BEFORE THE AIRCRAFT REACHES 34,167 TOTAL AIRCRAFT FLIGHT CYCLES(TOTAL AIRCRAFT FSDR CALA2023081602531Battery · no testEPSU BATTERY (12WL) FAILED ON EMERGENCY LIGHTNING CAPACITY TEST AND REQUIRES REPLACEMENT. RECORDED ON LTPR NR#5001249497-0010. BATTERY REPLACEMENT OF (12WL) PERFORMED IAW AMM:33-51-38-000-002 & 33-51-38-400-002 REV 120. TEST SATISFACTORY. REMOVED PART INFO P/NSDR CALA2023081602530Battery · no testEPSU BATTERY (13WL) FAILED ON EMERGENCY LIGHTNING CAPACITY TEST AND REQUIRES REPLACEMENT. RECORDED ON LTPR NR#5001249498-0010. BATTERY REPLACEMENT OF (13WL) PERFORMED IAW AMM:33-51-38-000-002 & 33-51-38-400-002 REV 120. TEST SATISFACTORY. REMOVED PART INFO P/NSDR CALA2023081602529Battery · no testEPSU BATTERY (10WL) FAILED ON EMERGENCY LIGHTNING CAPACITY TEST AND REQUIRES REPLACEMENT. RECORDED ON LTPR NR#5001249492-0010. BATTERY REPLACEMENT OF (10WL) PERFORMED IAW AMM:33-51-38-000-002 & 33-51-38-400-002 REV 120. TEST SATISFACTORY. REMOVED PART INFO P/NSDR CALA2023081602528Battery · no testEPSU BATTERY (11WL) FAILED ON EMERGENCY LIGHTNING CAPACITY TEST AND REQUIRES REPLACEMENT. RECORDED ON LTPR NR#5001249494-0010. BATTERY REPLACEMENT OF (11WL) PERFORMED IAW AMM:33-51-38-000-002 & 33-51-38-400-002 REV 120. TEST SATISFACTORY. REMOVED PART INFO P/NSDR CALA2023050501380Lever · inoperativeLNDG GEAR HANDLE DIFFICULT/REQRD HARD PULL TO MOVE/OUT OF LOCKED POSITTO RAISE/LOWER GEAR.. REMOVED AND REPLACED LANDING GEAR NORMAL CONTROL LEVER IAW AMM 32-31-11-400-001-A . OPS CHECK NORMAL NO FAULT. PARTS USED: 1958895,QTY :1 ADD EMP:U165757 ROTABLE PARTS SDR CALA2023032700900Switch · faultedSYS 1 FAULT DISPLAYED ON UPPER ECAM SCREEN. - BRAKES BRAKE SYS 1 FAULT 2 MINUTES AFTER T/O.BRAKE SYS 1 FAULT ON GND FIXED WITH RESET. CORRELATED FAULTS SHOWED "BRAKES A/SKID FAULT, BSCU DC SPLY 1PP, AFS BSCU AND BRK PEDAL XMTR (9GG)" TS BRAKE PEDAL XMTR REF TSSDR CALA2023032700889Proximity Sensor · unknownENG 2 REVERSER FAULT FAULT CAUSED BY SENSOR FAULT 23GA. REPLACED PROXIMITY SENSOR 23GA AND CONNECTOR, CONTACTS DUE TO CORROSION ON MLG LH EXT SENSOR. FAULT CLEARED. CSAS/IGGS TEST PERFORMEND, PASSED. LGCIU TESTS PASS, ECAM STATUS NORMAL.SDR CALA2023020600324Not Reported · not reportedBRAKES AUTO BRAKE FAULTAFTER GO AROUND CREW REPORTED TOUCHING DOWN BRIEFLY WITH #1 TIRE THEN HAVING TO SCAN NO FAILURES AND BSCU TEST AND RESETS WITH NO FAULTS AMM GO AROUND BECAUSE OF HEAVY WIND CONDITIONDS LANDED NORMAL WITH 32-46-00 SYS OPS CK. NORMAL NO ANSDR CALA2021121302356Epsu · inoperativeEMERGENCY EXIT LIGHTS OVER 2L AND 2R ARE ON. ALL OTHERS ARE OFF. BITE TEST FAULT AS FOLLOWS ATA 33-51-38 ,EPSU INT LOAD AFT L. REPLACED EPSU 13WL AND BATTERY PER AMM 33-51-38-000-001-A, AMM 33-51-38-000-002-A . OP CHECKS GOOD . ADD EMP:U102091 ROTABLE PARTS CHSDR CALA2019110301887Pressure Panel · crackedCRACKS FOUND AT FRAME 35 L/H OUTSIDE THE CUTOUT AREA AT HOLES 2, 3,4,17,20,21,25, AND 26. REPAIRED CRACKED HOLES 2,3,4,17,20,21,25, AND 26 AT L/H FRAME 35 IAW ECRA 5331-02468. ACCOMPLISH REPAIR AT FR35-36 L/H PRESSURE PANLES HOLES PER PART 3 OF ECRA ON OR BEFOSDR CALA2019102901848Wire · damagedAAR N/R S/N 9823782.(SUPPORT TASK) L-63, DOT 007, EEPL CABLE SEA T CONNECTOR AT SEAT ROW 7LH HAS DAMAGED WIRE. RE-PINNED CONNECTOR IAW A319 ESPM 20-48-25-0101-021 OPS CHECK TO BE PERFORMED ON ROUTINE CARD NO. 17-3351-1-7907.SDR CALA2019102501806Threshold · corroded(A3NB-53-3-6187) CABIN FLOOR; FR68 R2 DOOR THRESHOLD HAS CORROSI ON. REFER TO AAR N/R: 9823218. REPLACED R2 DOOR THRESHOLD AT FR66-68 IAW A319 SRM 51-42-11-801. THREATED, PRIMED AND PAINTED IAW A319 SRM 51-21-11-801.SDR CALA2017111304057Power Supply · faultedAFT CABIN EMERGENCY LIGHT POWER SUPPLY TEST FAULTED. REPLACED THE POWER SUPPLY IAW AMM 33-51-38-400-001-A, TESTED OK.SDR CALA2017100203417Power Supply · no testEMERGENCY LIGHTS FAILED TO TEST, FWD LEFT EPSU, REPLACED THE EPSU IAW MM 33-51-00. CHECKED GOODSDR CALA2017050801299Lens · missingEMERGENCY EXIT LIGHT COVER MISSING...OVERWING EXIT 21A FOUND AND INSTALLED LENS COVERSDR CALA2014042190871Oil System · lowAPU OIL QTY LESS THAN 3.9 QTS, PULSING GREEN, APU. APU OIL SERVICED IAW AMM49-90-00- 600-004-A.SDR CALA2014030790541Unknown · malfunctionedFUEL ON BOARD INDICATION INOPERATIVE ON FUEL SYS ECAM PAGE. FUEL CREW COMMENTS 1500 LBS FUEL UNACCOUNTED FOR OVER 20 MINUTES. CREW REPORTED RT FUEL QTY GAUGE WAS ERRATIC. FOLLOW TSM 28-11-00-810-806-A. ACCOMPLISHED MT 28-013, NO FAULTS FOUND. CHECKED SUMMSDR CALA2014012790232Support · wornAIR RETURN LAX DUE TO A NOSE GEAR INDICATION ISSUE. JACKED NOSE GEAR, FOUND PLAY IN TARGET SUPPORT PUTTING INDUCTANCE AT MINIMUM FOR SWITCH 25GA & 24GA, FOUND TARGET SUPPORT WORN WHERE PUSH ROD ATTACHES.SDR CALA2014012490226Sensor · failedAIR RETURN LAX DUE TO A NOSE GEAR INDICATION ISSUE. BOTH LANDING GEAR SENSORS FAILED.SDR CALA2013121993805Acoustic Liner · damagedNR 2 ENG 6 O`CLOCK POSITION 2 INCH BY 1 DAMAGE IS IN ACOUSTICAL MATERIAL APPROXIMATELY 4 INCHES FROM AFT FLANGE. IAW MT71-006G FOR ALLOWABLE LIMITS. IAW ECRA 7111-01489 FOR ALLOWABLE FLY ON CRITERIA. INSPECTED IAW ECRA 7111-0 1489 & FOUND TO BE OK FOR CONTISDR CALA2013110692697Receptacle · shortedLGCIU 1 FAULT DISPLAYED ON UPPER ECAM SCREEN L G, CAME ON DURING CLIMB. CFDS ATA 323171 LGCIU1 05GA1 ID LGCIU TSM32-31-00-810-802-A O5GA1 565-9032. LGCUI 1 FAULTED 20GA PROX SENSOR. IAW ASM 32-31-03, CHECKED WIRING FROM LGCIU 1 BENCH PLUG TO 20GA PROX SENSOSDR CALA2013100891826Windshield Wiper · out of adjustCOPILOTS WINDSHIELD DOES NOT CLEAR WINDSCREEN ADEQUATELY. UNSAFE TO SEE ON APPROACH TAXIING. ADJUSTED WINDSHIELD ARM & FOUND A WINDSHIELD WIPER TO WORK AS DESIGNED.SDR CALA2013092391380Computer · faultyFLT CTL AIL SERVO FAULTS. DUE TO REPEAT ECAM FLT CTL AIL SERVO FAULT WITH CFDS MSG "L G AIL MODE VLV 33CE1". REPLACED ELAC 2, ELAC 2 MR27935-328 ON -217 OFF.SDR CALA2013081290363Extinguisher · low pressureAFT LAVATORY WASTE BIN FIRE EXTINQUISHER NEEDLE IS IN IN RED. SMOKE DETECTOR SYS OP NORMAL LAV USABLE. R & R AFT LAV WASTE BIN FIRE EXTINGUISHER.SDR CALA2013080890259Extinguisher · reads lowAFT LAVATORY WASTE BIN FIRE EXTINQUISHER NEEDLE IS IN THE RED SMOKE DETECTOR SYS OPS NORMAL.SDR CALA2013073090068Oxygen Mask · leakingCAPTAIN'S OXYGEN HARNESS FAILS TO INFLATE (LEAKING). RT RELEASE LEVER ON CAPTS O2 MASK BROKE OFF. CONT O2 FLOW UNLESS LT DOOR CLOSED AND SYS IS RESET. REPLACED CAPTS O2 MASK.SDR UALA2013052003473Seat Back · looseF/O SEATBACK LT SIDE HAS LOOSE CONNECTION. REPLACED F/O SEAT.SDR UALA2013043003021Solenoid · faultyFLAP TIP BRAKE FAULT DISPLAYED ON UPPER ECAM SCREEN. FOUND SFCC-1 FAULTING LEFT WTB BLUE SOLENOID 33CV. REPLACED 33CV SOLENOID REF MM.SDR UALA2013041702627Battery Pack · faultyEMERGENCY LIGHT MESSAGE FOR EPSU BATTERY. REMOVED AND INSTALLED BATTERY PACK AND FAULT CLEARED.SDR UALA2013022601170Controller · malfunctionedANTI-ICE LT WINDSHIELD DISPLAYED ON ECAM. NO FAULTS RECORDED ON CFDS AT THIS TIME. REPLACED WINDSHIELD HEAT CONTROLLER NR 1 PER MM.SDR UALA2013012800516Panel · unsecureSCREW LOOSE IN FRONT OF CAPTAINS WINDSHIELD. PANEL STICKING UP. SECURED SCREW.SDR UALA2013010900155Sill · corrodedR2 DOOR SILL CORROSION AT FR 68. INSTALLED STRAP REPAIR PER SRM 53-41-14 FIG 201. MAJOR REPAIR.SDR UALA2012081404508Actuator · malfunctionedFCTL FLAPS SYS FAULT. FLIGHT DIVERTED. WHILE PERFORMING VISUAL INSPECTION, FOUND NR 1 LT FLAP ROTARY ACTUATOR WITH ACTIVATED TORQUE LIMITER. INSTALLED NR 1 LT ROTARY ACTUATOR PER AMM. REPLACED LT NR 1 FLAP TRACK ACTUATOR. COMPLETED INSTALLATION FROM ITEM SDR UALA2012061403258Protector · rupturedUNWANTED FUEL TRANSFER FROM LEFT TO CENTER TANK. SUSPECT CTR OVER PRESSURE VALVE 96QM. FOUND OVERPRESSURE PROTECTOR 96QM RUPTURED. REPLACED PROTECTOR. SEE AMIS ITEM 0302003 FOR FURTHER INFORMATION.SDR UALA2012011800376Controller · faultyUNABLE TO GET THE APU TO START. CREW TRIED TWO TIMES, NO JOY, CYCLED CB'S L-41 AND L42. THIRD ATTEMPT WAS NO GOOD. OK TO DEFER THE APU INOP PER MEL 4910B. OK TO DEFER APU INOP PER MEL 4910B. RPL- T-S PER TSM49-00-00-810- 899, RPLD ECB (59KD) PER MM49-61-3SDR UALA2011120506687Hose · leakingFIRST OFFICER'S OXYGEN HARNESS FAILED TO INFLATE (LEAKING). HOSE FITTING AT MASK LEAKING WHEN SLIGHT AMOUNT OF PRESSURE APPLIED. REPLACED F/O O2 MASK.SDR UALA2011120506663Retainer · damagedCART RESTRAINT QUARTER TURN MISSING AT 204 QUARTER TURN STILL THERE, BUT IS PULLING AWAY FROM UNIT. REPLACED RETAINER AND LOCK AT POSITION 204.SDR UALA2011110906106Window · delaminatedRIGHT AFT F/O WINDOW DELAMINATED. DELAM MEASURES 3 AND 5-8 DEFERED PER MT56-00. REPLACED WINDOW PER AMM.SDR UALA2011102505776Structure · damagedNR 2 ENGINE RT FAN COWL DAMAGED. DAMAGE OUT OF LIMITS PER AMM. FBO FOUND DAMAGE .125" D X 4" L X .375" W. NO CRACKS. GOUGE INTO CORE. OUT OF LIMITS PER AMM FOR ZONE 'C'. REPLACED FAN COWL.SDR UALA2011092605206Latch · brokenRIGHT OVERWING ESCAPE ROPE PANEL LATCH IS BROKEN. PANEL IS DAMAGED AND SECURED CLOSED. LINE IS CONSIDERED INOPERATIVE IAW MEL PLACARD 2560M.SDR UALA2011072503805Flt Controls · malfunctionedON 2 LEGS NOTED EXCESSIVE YAWING IN BACK OF A-C. PASSENGERS GETTING SICK FLYING IN SMOOTH AIR. PERFORMED AFS BITE=BOTH FAC COMPUTERS=NO FAULTS. PERFORMED OPERATIONAL TEST OF THE YAW DAMPER FUNCTION OF SYSTEM 1 AND SYSTEM 2=NO FAULTS.SDR UALA2011071303540Latch · out of adjustO2 MASKS DEPLOYED AT 29ABC. O2 DEPLOYMENT WAS AT 28ABC NOT 29ABC, SEATS 28ABC HAVE BEEN REMOVED FROM SERVICE. ADJUSTED CONTAINER DOOR LATCHING PIN PER MT. REPACKED MASKS PER AMM AND PERFORMED SATISFACTORY OPERATIONAL CHECK OF MANUAL MASK RELEASE PER MM. SEATSDR UALA2011061302919Oxygen Mask · leakingCAPTAIN'S OXYGEN HARNESS FAILS TO INFLATE (LEAKING). HARNESS ATTACH POINT PIN MISSING SWAPPED WITH SECOND OBSERVERS MASK. CAPT'S O2 MASK CHECKED NORMAL. INOPED SECOND OBSERVER SEAT. REPLACED SECOND OBSERVERS MASK PER AMM. OPS CHECKED NORMAL.SDR UALA2011022100855Harness · leakingCAPTAIN'S OXYGEN HARNESS FAILS TO INFLATE (LEAKING). REPLACED MASK, OPS CHECK GOOD.SDR UALA2010110104054Battery · inoperativeAFT FLASHLIGHT DOES NOT FLASH. REPLACED BATTERY, OPS CHECKED GOOD.
Back to N833UA