N835UA
Service difficulty reports · 94
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N835UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N835UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2013122693960Connector · faultyBCL 1 FAULT DISPLAYED UPPER ECAM. REPLACED BATTERY LINE CONNECTOR 6PB1, CHECKED GOOD, MESSAGE DID NOT RETURN.SDR CALA2013122393877Lens · missingEMERGENCY EXIT LIGHT ON CLOSET DOOR 1L MISSING COVER. BULB EXPOSED BUT IS INTACT.SDR CALA2013121393685Sensor · faultyLGCIU 1 FAULT DISPLAYED ON UPPER ECAM SCREEN LG. R & R 26GA FAULT REMOVER, OPERATIONS NORMAL.SDR CALA2013081290361Receptacle · leakingHIGH PITCH SQUEAL CONTINUES. APPEARS TO BE COMING FROM BELOW INSTRUMENT PANEL. SUSPECT E & E DOOR. PRESSURIZED ACFT, FOUND LEAK AT THE EXTERNAL GROUND POWER RECEPTACLE. TORQUED RECEPTACLE REF MM. PRESSURIZED AND OPS CK GOOD.SDR UALA2013050203059Oxygen Mask · out of positionSEAT 2EF O2 MASK NEEDS STORING. RE-SECURED O2 COMPARTMENT PER MM. MASKS NOT DISTURBED.SDR UALA2013041502587Blowout Panel · damagedAFT CARGO BLOW OUT PANEL LEFT SIDE AFT OF DOOR OPENING IS DAMAGED ON CORNER. REPLACED BLOWOUT PANEL.SDR UALA2013040802321Oven · faultyOVEN 407 HEAT IS ON WITH CIRCUIT BREAKER PULLED AND SWITCH OFF AFT GALLEY. REPLACED OVEN ASSY.SDR UALA2013032501825Seal · dirtyAFT RIGHT CABIN DOOR HAS A WHISTLING NOISE AT CRUISE. INSPECTED R2 DOOR SEAL, FOUND SMALL AMOUNTS OF DEBRIS ON LOWER PART OF DOOR SEAL, NO HISTORY, OK TO CONTINUE.SDR UALA2013032201811Oxygen Bottle · lowCREW OXYGEN SYSTEM-LOW. FOUND O2 BOTTLE WELL ABOVE LIMITS OF 8300 PSI, PER CAPTS REQUEST SERVICE O2 TO FULL. REMOVAL-INSTALLATION OF BOTTLE PER MM. LEAK CHECKED OKAY.SDR UALA2013032101775Warning Message · false activationDOOR L CABIN OPEN ECAM ON ROLLOUT. TROUBLESHOT PER TSM 52-11- 00-810-804-A. FOUND SLIDE ARMED INDICATOR LT ASSY AT FAULT (1WN1). PERFORMED OPS TEST EMERGENCY PAX DOORS IAW MM 52-73-00-710-001-A, TEST PASSED. COULD NOT DUPLICATE FAULT. OPS CHECKED L1 DOOR PSDR UALA2013030401266Fuel Tank · damagedDURING HMV2, MISDRILLED HOLE FOUND ON THE CENTER TANK UPPER SKIN AT Y153 STRINGER 2. REPAIRED PER ECRA 5710-02271 AND REO L01389.SDR UALA2013011600265Disc · missingON WALK AROUND FOUND CREW O2 GREEN DISCHARGE DISC MISSING. INSTALLED NEW DISC.SDR UALA2012122107365Windshield · crackedAPPEARS TO BE A CRACK AT BOTTOM OF F/O FWD WINDSHIELD. REPLACED F/O WINDSHIELD PER AMM.SDR UALA2012100305601Spherical Bearin · faultyLANDING FLAPS FULL HAD MOD VIBRATION. RETURNED TO FLAPS 3 VIB CEASED. RETURNED FLAP FULL VIB. LEFT FLAP SPHERICAL BEARING. LT WING NR 1 FLAP CARRIAGE CENTER GUIDE ROLLER RETAINING NUTS NEED TO BE INSTALLED PER MM TO COMPLETION. INSTALLED AND TORQUED RETAISDR UALA2012092905502Starter · faultyNO START ON L ENGINE. REPLACED NR 2 ENGINE STARTER.SDR UALA2012090504996Paint · peelingRIGHT SIDE RVSM AREA BY F/O HAS LARGE SECTION OF PAINT ABOUT SIZE OF SILVER DOLLAR MISSING. REMOVED PEELING PAINT AT FWD EDGE OF EXTRA CRITICAL AREA, APPROX 3" X 2.25" IN GOLD STRIPE. DEPTH OF MISSING PAINT IS .005", SKIN WAVINESS CHECK GOOD. REPRED PAINT RSDR UALA2012071903937Control Box · failedCIRCUIT BREAKER TRIPPED REAR PANELS. V SHOWING ON LOWER ECAM. AMBER XX'S SHOWN ON ZONE CONTROL. REMOVED, INSPECTED, AND INSTALLED ZONE TEMP CONTROL BOX. VERIFIED GOOD DUCT TEMP.SDR UALA2012011600344Warning System · false activationDURING INITIAL RETRACTION GEAR SHOWED IN TRANSIT, WOULD NOT LOCK UP. GEAR CYCLED, THEN RETRACTED NORMALLY. SEE PFR FOR NLG EXT PROX SENSOR 25GA TGT POS FAULT. FOUND NO CURRENT FAULT, FAULT "N L-G EXT PROX SNSR 25GA TGT POS" ON PFR. FOLLOWED TSM 32-3 1-00-81SDR UALA2011121906934Battery Pack · inoperativeEMERGENCY LIGHT TEST WILL NOT PASS ON FWD ATTENDANT CIDS PANEL. REPLACED FWD EMERGENCY LIGHT BATTERY PACK, EMERGENCY LIGHTS TESTED GOOD.SDR UALA2011102005677Skin · damagedFOUND BLENDED AREA AT BOTTOM OF EXTRA CRITICAL AREA OF RVSM, REMOVED BLENDED FASTENER MATERIAL LOSS WITHIN LIMITS REF SRM 53-11-11, WITHIN LIMITS IAW SRM 53-00-11, ACCOMPLISHED HFEC INSPECTION OF AREA, NO CRACKS FOUND IAW NDT51-10-08 PART 6.SDR UALA2011100505403Elevator · out of rigACFT IN CRUISE IS CONTINUOUSLY MAKING FORE AND AFT TRIM MOVEMENTS WITH MINOR ALTITUDE CLIMB AND DESCENTS. THE ALTITUDE GAIN OR LOSS IS ABOUT 20 FT EITHER WAY IN SMOOTH AIR. AS IF ACFT HAVING A DIFFICULT TIME HOLDING ALTITUDE WITH ASSOCIATED TRIM WHEEL MOVEMSDR UALA2011091604995Sliding Window · defectiveRIGHT AFTER LANDING CAPTS SLIDING WINDOW FOGGED OVER. DIFFICULT TO SEE DURING GROUND OPS. REMOVED CAPT'S SLIDING WINDOW. REMOVED GLASS PANE AND INSTALLED NEW UNIT ONTO FRAME WITH ONLY FOUR SCREW FINGER TIGHT. ALL NEW FASTENERS ATTACHED TO WINDOW AND ALL OLD SDR UALA2011091604994Sleeve · delaminatedAREA OF DELAM ON THE NR 2 ENG LT REVERSER SLEEVE AT THE BOTTOM SEAM LINE JUST FWD OF THE TWO AFT MOST LATCHES. ACP'D HFEC ON NR 2 ENG INBD UPR REV TRACK PER NTM 51-10-08 PART 6 AND UA-EVA81307. NO CRKS DETECTED. BLENDED GOUGES PER UA EVA 8137. ALODINED AND PRSDR UALA2011060202683Cover · missingCOVER OVER APU EXHAUST INCLUDING WHITE POSITION LIGHTS IS NOT ON AIRCRAFT. REMOVED APU EXHAUST SHROUD IAW MM. REMOVED & REPLACED DAMAGED LOWER FRAME 86 PER SRM. FABRICATED BONDING ANGLE IAW DRAWING D92485114 NR 19 SH 001. INSTALLED APU MUFFLER IAW MM. REPLASDR UALA2011021800832Control Unit · faultyLAVATORY-CARGO SMOKE DET FAULT ON ECAM. REPLACED SDCU, TESTS GOOD.SDR UALA2010071402525Smoke Detector · damagedRAMP REPORTS AFT CARGO COMP. SMOKE DETECTOR DAMAGED. REPLACED SMOKE DETECTOR.SDR UALA2010021500570Mount · faultyRT FWD PAX ENTRY DOOR - EVACUATION SLIDE LWR AFT - EVAC. SLIDE ATTACH - MOUNT IS CRACKED - APPROX. 1 IN. LONG. EVACUATION SLIDE REPLACED IAW OV WU J7571B BY AMT IAW JC 4R2592053 SEQ. 467.SDR UALA2010021500552Skin · puncturedFUSELAGE SKIN PUNCTURED AT 10' AFT OF FR 77, LBL 10' FROM UPPER CTR LINE. NDT WEB NO CRACK FOUND, HFEC INSPECTED NO CRACK FOUND ON INNER STRUCTURE. REPAIRED DAMAGED SKIN REF SRM. MARKED INTERNAL STRUCTURE WITH SRM & DATE REF.SDR UALA2010021200532Door · faultyCABIN - DR 2L O2 MASK DOOR FAILED TO OPEN. FROM BASE W-U S1627L. ADJUSTED & SECURED BOX REF DOCK WU S1627L.SDR UALA2010021200531Door · faultyCABIN - FWD GALLEY O2 MASK DOOR FAILED TO OPEN. FROM BASE W-U S1626L. CORRECTED WIRING REF WDM. REF DOCK WU S1626L. OPS CK OK.SDR UALA2010020500463Fire Bottle · leakingF/A REPORTS H2O FIRE EXT LEAKING. H2O BOTTLE.SDR UALA2009092102978Loop · inoperativeAIR BLEED MESSAGE. SENSING ELEMENT IN LT AC BAY PREVIOUSLY REPOSITIONED. IAW TSM FOUND HIGH RESISTANCE BETWEEN PIN A-4D AND PIN A-5D OF THE BMC 2. RESISTANCE CHECKS GOOD BETWEEN PIN A-4D OF BMC TO CABLE 77HF. CONTINUED INSTALLATION OF SENSING ELEMENT THRU ENDSDR UALA2009031000671Bearing · failedOIL ODOR IN CABIN. RTFL. REPLACED NR 1 ENG, HAD OIL CONTAMINATION AT THE ROOT OF ALL HPC STG 3 BLADES (MAIN BEARING FAILURE).SDR UALA2009030200671Engine · faultyOIL SMELL IN CABIN. RTFL. BOROSCOPED NR 1 ENG FOUND EVIDENCE OF OIL AT 3RD STAGE HPC. SPINNER REMOVED NO OIL FOUND REINSTALLED. REPLACED BOTH RECIRCULATION FILTERS. FOUND NR 1 ENG (V10095) HAS OIL CONTAMINATION AT THE ROOT OF ALL HPC STG 3 BLADES. PER EMSDR 2008UALA04263Engine · leakingAFTER ENGINE SHUTDOWN AN UNUSUALLY LARGE AMOUNT OF SMOKE CAME FROM TAILPIPE. FOUND OIL RUNNING DOWN LAST STAGE OF LPT DISK AND ONTO BLADES.SDR 2007UALA04716Unknown · unknownLEFT OUTER FUEL TRANSFER VALVE AMBER HALF CLOSED. NO STATUS MSG. VALVE WAS FOUND TO BE OPERATING NORMALLY.
SDR 2007UALA01321Bleed Valve · malfunctionedRTFL DUE TO A PRESSURIZATION PROBLEM. [06-22-07] REPLACED NR 2 BLEED AIR REGULATOR VALVE.SDR 2007UALA00242Window · overheatedCAPTS SLIDING WINDOW OVERHEATED TO POINT OF DISTORTING WINDOW AND BUBBLING WITHOUT ANY OVERHEAT MESSAGE OR INDICATION TO CREW, SUSPECT PROBLEM WITH WINDOW HEAT SYSTEM. REPLACED CAPTAINS SLIDING WINDOW. OPS CHECKED NORMAL.SDR 2006UALA02130Pump · leakingDIVERTED FLIGHT DUE TO GREEN HYDRAULIC SYSTEM PROBLEM. RAN ENGINE AND PERFORMED LEAK CHECK. NR 1 ENGINE HYDRAULIC PUMP FOUND LEAKING FLUID BETWEEN PUMP HALF'S. REPLACED NR 1 LEFT ENGINE HYDRAULIC EDP. OPS CHECKED GOOD.SDR 2006UALA00477Radar · failedWHILE EN ROUTE TO ORD WX RADAR FAILED. FLIGHT DIVERTED DUE TO THUNDERSTORMS/RAIN AT PLANNED DESTINATION. WEATHER RADAR TRANSCEIVER INOPERATIVE. REPLACED WEATHER RADAR TRANSCEIVER.SDR 2005UALA01503Engine · flamed outNR 2 ENG FLAMED OUT IN CRUISE. ENG FAIL EICAS MSG. OIL PRESS, QTY GOOD. ATTEMPTED TO RESTART TWICE, NO LIGHT OFF. FMU SHUT OFF TORQUE MOTOR FAILED INTERNALLY. THIS IS A KNOWN ISSUE AND IS BEING ADDRESS ON ATTRITION PER A CATEGORY 6 SERVICE BULLETIN. HOWEVESDR 2005UALA00980Oven · smokeF/A REPORTS SMOKE COMING OUT OF OVEN. SECURED IT AND DIVERTING FLIGHT. INITIAL INSPECTION REVEALED A DIRTY FILM ON INTERIOR OF OVEN WITH A DISTINCT ODOR THAT COULD HAVE CAUSED "SMOKING" CONDITION. THE OVEN WAS INSPECTED AND CHECKED/TESTED PER MANUFACTURER'SSDR 2005UALA00939Battery · failedCABIN EMERGENCY LIGHT TEST FAILED WITH MESSAGE: EPSU INT LOAD EMER L. REPLACED BATTERY 11WL.SDR 2004UALA00725O-Ring · leakingLOW BOTTLE PRESSURE. BOTTLE TO VALVE O-RING DETERIORATED. REPLACED CYLINDER ASSY.